At least 937 records · Page 52

Socioeconomic indicators for sustainable design and commercial development of algal biofuel systems

Abstract Social and economic indicators can be used to support design of sustainable energy systems. Indicators representing categories of social well‐being, energy security, external trade, profitability, resource conservation, and social acceptability have not yet been measured in published sustainability assessments for commercial algal biofuel facilities. We review socioeconomic indicators that have been modeled at the commercial scale or measured at the pilot or laboratory scale, as well as factors that affect them, and discuss additional indicators that should be measured during commercialization to form a more complete picture of socioeconomic sustainability of algal biofuels. Indicators estimated in the scientific literature include the profitability indicators, return on investment (ROI) and net present value (NPV), and the resource conservation indicator, fossil energy return on investment (EROI). These modeled indicators have clear sustainability targets and have been used to design sustainable algal biofuel systems. Factors affecting ROI, NPV, and EROI include infrastructure, process choices, and financial assumptions. The food security indicator, percent change in food price volatility , is probably zero where agricultural lands are not used for production of algae‐based biofuels; however, food‐related coproducts from algae could enhance food security. The energy security indicators energy security premium and fuel price volatility and external trade indicators terms of trade and trade volume cannot be projected into the future with accuracy prior to commercialization. Together with environmental sustainability indicators, the use of a suite of socioeconomic sustainability indicators should contribute to progress toward sustainability of algal biofuels.

09 BIOMASS FUELS↗

Special Analysis of the Area 3 Radioactive Waste Management Site at the Nevada National Security Site, Nye County, Nevada

This report describes the methods and results of a special analysis (SA) of the Area 3 Radioactive Waste Management Site (RWMS) on the Nevada National Security Site (NNSS). The purpose of the SA is to determine if the approved performance assessment (PA) and composite analysis (CA) (Shott et al., 2001) remain valid. The Area 3 RWMS PA and CA were prepared as a single document and received conditional approval on October 6, 1999. A conditional Disposal Authorization Statement (DAS) for the Area 3 RWMS was issued on October 20, 1999. Since preparation of the approved PA and CA, new information and additional environmental monitoring data have been used to update the PA and CA. At the same time, continual advancements in computer processors and software have allowed improvement to the PA and CA models. Annual reviews of the PA and CA required by U.S. Department of Energy (DOE) Order DOE O 435.1 have documented multiple changes occurring since preparation of the PA and CA. Potentially important changes include: Development of a new and improved baseline PA and CA model implemented in the probabilistic GoldSim simulation platform. A significant increase in the waste inventory disposed at the site. Revision and updating of model parameters based on additional years of site monitoring data and new research and development results. Although changes have occurred, many important PA/CA issues remain unchanged, including the site conceptual model, important features, events, and processes, and the points of compliance. The SA is performed to document the current status of the PA/CA model and to quantitatively assess the impact of cumulative changes on the PA and CA results. The results of the SA are used to assess the validity of the approved PA/CA and make a determination if revision of the PA or CA is necessary. The SA was performed using the Area 3 RWMS, version 2.102, GoldSim model, the current baseline PA/CA model. Comparison of the maximum SA results with the PA performance objectives indicates that there continues to be a reasonable expectation of compliance. The resident exposure scenario was evaluated for compliance with the air pathway and all-pathways annual total effective dose (TED) performance objectives. The maximum mean air pathway TED, 7E-6 millisievert (mSv) at 1,000 years (y) has decreased relative to the approved PA and is significantly less than the 0.1 mSv limit. The maximum mean all-pathways annual TED, 7E-5 mSv at 1,000 y has increased but remains a small fraction of the 0.25 mSv limit. The SA maximum mean radon-222 (222Rn) flux density, 0.03 becquerel per square meter per second (Bq m-2 s-1), has increased relative to the PA results but is significantly less than the 0.74 Bq m-2 s-1 limit. The SA results continue to support a conclusion that the disposed waste inventory is protective of intruders and groundwater resources. The maximum mean intruder TED, 0.01 mSv for an acute construction scenario at the U-3ah/at disposal unit, was less than the 5 mSv performance measure. Site monitoring data and research results continue to support a conclusion that a groundwater pathway will not exist within the 1,000 y compliance period. Projected releases to the environment are a small fraction of the performance objectives. Cost-effective options for reducing releases further are unlikely to exist. Therefore, releases from the Area 3 RWMS are judged to be as low as reasonably achievable. Comparison of the maximum CA result with the 0.3 mSv CA dose constraint indicates that no action is required to reduce the dose from the Area 3 RWMS and all interacting sources of residual radioactive contamination. The SA maximum mean CA annual TED, 0.02 mSv at 1,000 y, has increased from the approved CA result but remains less than 10% of the dose constraint. The CA TED continues to be due predominantly to inhalation of plutonium-239 resuspended from soils contaminated by nuclear weapons tests conducted near the Area 3 RWMS. The SA results estimated with the Area 3 RWMS version 2.102 model indicate that changes to the PA and CA do not significantly alter the PA/CA results or conclusions. Although increases occur for the all-pathways annual TED, the 222Rn flux density, and the CA annual TED, all PA and CA results are a small fraction of the performance objectives or dose constraints. The same conclusion was reached for the approved PA and CA. The SA results continue to support a conclusion that there is a reasonable expectation of meeting all performance objectives and the CA dose constraint. There is no need to revise the DAS at this time. The SA results support a conclusion that the Area 3 RWMS PA and CA remain valid, and revision is not necessary at this time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TA-V Sub-Area Plan: Overview & Summary

The TA-V Sub-Area Plan is currently under development. A major input into the plan will be the results of a strategic planning study to be conducted in FY 2016 that will investigate the long-term programmatic future for TA-V. Anticipated planning issues to be explored include: (1) Nature of future programs and facility needs; (2) Recapitalization needed to sustain key facilities and resources; (3) Validation of existing land use as a remote nuclear research and radiation testing site; (4) Physical security requirements including the need to sustain or reconfigure the existing Perimeter Intrusion Detection and Assessment System (PIDAS); (5) Environmental remediation and restoration strategy; and (6) Site design improvements needed to enhance the quality of the working environment.

99 GENERAL AND MISCELLANEOUS↗

Behavioral Health/Employee Assistance Program (EAP) Report FY 15

The Sandia National Laboratories’ (SNL) Corporate Behavioral Health Program is a workplace based program that 1) assists in the early identification and resolution of personal concerns which may impact job performance, 2) assists managers and the organization in addressing productivity issues, and 3) supports the SNL commitment to provide a safe and healthful work environment. The program is offered to approximately 10,711 employees in New Mexico. The Behavioral Health Program is a corporate program combining services in NM and CA. It is integrated with other occupational health and clinical services including disability, disease management and preventive health programs. In addition, Sandia’s Behavioral Health Program interfaces with external organizations in Human Resources, the Department of Energy and Security through the Clinical Evaluation (CE) Human Reliability Program (HRP) and Workplace Violence programs. The program supports Sandia National Laboratories’ mission to safeguard national security, the environment, the public and is a proactive approach to early identification, intervention and assessment. Last, it reduces barriers to accessing mental health services and assists with reducing health care costs attributed to illness or injuries related to unhealthy lifestyles and behaviors. The EAP team is comprised of a professional staff including a licensed Clinical Psychologist who has a NM state license for psychotropic medication prescriptive authority, is board certified in Clinical Neuropsychology, and a Certified Employee Assistance Professional (CEAP), a licensed professional clinical counselor NM State Licensed (LPCC) and a licensed Marriage and Family counselor (MFT) who is also a Certified Employee Assistance Professional and who holds a doctorate in counseling psychology.

99 GENERAL AND MISCELLANEOUS↗

Space Strategy at a Crossroads: Opportunities and Challenges for 21st Century Competition

In its November 2018 report to Congress, the bipartisan National Defense Strategy Commission applauded the main themes of the Trump administration’s 2017 National Defense Strategy. But it was also deeply critical of the strategic thought so far done by the U.S. defense community about the requirements, operational and otherwise, of securing U.S. and allied interests in the types of conflicts we now face. Indeed, it assessed these shortfalls as crippling to the exercise of American power and as dangerous in crisis and war. Is the U.S. military space community exempt from such criticism? Should it be?

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cybersecurity at the Grid Edge: Protecting LA's Energy Systems in a Connected World

Join SoCalGas and the National Laboratory of the Rockies (NLR) for an insightful webinar on securing operational technology and energy systems. Los Angeles has the second-largest metro by population in the nation, making it vital to protect the energy infrastructure that powers day-to-day life. However, cybersecurity for energy systems is an immense challenge due to an increasing number of interconnected devices and stakeholders. While there was traditionally a limited need to secure energy infrastructure, the grid is only becoming smarter and more software-defined. Amid aging infrastructure and evolving cyber threats, the need to ensure the security of energy is at an all-time high. Together, SoCalGas and NLR are assessing the current state-of-the-art of the energy ecosystem to understand gaps in current best practices and technologies relevant to powering the city of Los Angeles.

97 MATHEMATICS AND COMPUTING↗

Reliability modeling of fault-tolerant computer based systems

Digital fault-tolerant computer-based systems have become commonplace in military and commercial avionics. These systems hold the promise of increased availability, reliability, and maintainability over conventional analog-based systems through the application of replicated digital computers arranged in fault-tolerant configurations. Three tightly coupled factors of paramount importance, ultimately determining the viability of these systems, are reliability, safety, and profitability. Reliability, the major driver affects virtually every aspect of design, packaging, and field operations, and eventually produces profit for commercial applications or increased national security. However, the utilization of digital computer systems makes the task of producing credible reliability assessment a formidable one for the reliability engineer. The root of the problem lies in the digital computer's unique adaptability to changing requirements, computational power, and ability to test itself efficiently. Addressed here are the nuances of modeling the reliability of systems with large state sizes, in the Markov sense, which result from systems based on replicated redundant hardware and to discuss the modeling of factors which can reduce reliability without concomitant depletion of hardware. Advanced fault-handling models are described and methods of acquiring and measuring parameters for these models are delineated.

Bavuso, Salvatore J.↗

National Aeronautics and Space Administration's (NASA) Automated Information Security Handbook

The NASA Automated Information Security Handbook provides NASA's overall approach to automated information systems security including discussions of such aspects as: program goals and objectives, assignment of responsibilities, risk assessment, foreign national access, contingency planning and disaster recovery, awareness training, procurement, certification, planning, and special considerations for microcomputers.

Roback, E.↗

Personal Resiliency Index

A plethora of information exists in literature focusing on different aspects of personal resilience. There are a number of questionnaires available to measure resilience in different aspects of an individual’s life, such as mental health. However, there is a lack of comprehensive information on the subject of personal resilience to natural and man-made disasters. A Personal Resiliency Index identifying four key areas of resilience related to natural and man-made disasters will help fill this gap by providing individuals an idea of where the stand comparatively to their peers on this topics. As an increasing amount of man-made disasters, natural disasters and pandemics occur, we realize that preparation is key.?“Crisis can be experienced at individual, group and mass levels and at local, regional, national or supra-national levels.” 1? Dr. Ron Fisher, the principal investigator has over 20 years’ critical infrastructure protection including developing vulnerability assessment methodology, risk and resiliency analyses and infrastructure interdependencies. Dr. Fisher and his team will research and develop a voluntary survey which evaluates the user’s personal resilience level to natural and man-made disasters. The research team is focusing on 4 main categories:? financial resilience, cyber security, physical and mental health, and emergency preparedness.?The web based application will?provide a resilience score for each of the categories and also a comprehensive personal resiliency score based on the voluntary survey. The application will also provide feedback to the user on actions to take to become more resilient to natural and man-made disasters. Through this effort, we will also be able to identify the areas where participants are excelling as well as opportunities for improvement in terms of resilience. This information will provide insight into areas of further investigation and identify potential areas of support needed for the general public to adopt strategies to become more resilient. 1 Lynott, William. “Surviving a Natural (or Man-Made) Disaster: How to Prepare for and Bounce Back? from a Crisis in Your Business | 2018-02-01 | NOLN.” Home Page, NOLN, 1 Feb. 2018, https://www.noln.net/articles/2683-surviving-a-natural-or-man-made-disaster-how-to-prepare-for-and-bounce-back-from-a-crisis-in-your-business.

99 GENERAL AND MISCELLANEOUS↗

Assessment of Vehicle Sizing, Energy Consumption and Cost Through Large Scale Simulation of Advanced Vehicle Technologies

The U.S. Department of Energy (DOE) Vehicle Technologies Office (VTO) has been developing more energy-efficient and environmentally friendly highway transportation technologies that will enable America to use less petroleum. The long-term aim is to develop "leapfrog" technologies that will provide Americans with greater freedom of mobility and energy security, while lowering costs and reducing impacts on the environment. This report reviews the results of the DOE VTO. It gives an assessment of the fuel and light-duty vehicle technologies that are most likely to be established, developed, and eventually commercialized during the next 30 years (up to 2045). Because of the rapid evolution of component technologies, this study is performed every two years to continuously update the results based on the latest state-of-the-art technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

Assessment of Data-Management Infrastructure Needs for Production Use of Advanced Machine Learning and Artificial Intelligence: Tri-Lab Level II Milestone (8554)

A robust data-management infrastructure is a key enabler for National Security Enterprise (NSE) capabilities in artificial intelligence and machine learning. This document describes efforts from a team of researchers at Sandia National Laboratories, Los Alamos National Laboratory, and Livermore National Laboratory to complete ASC Level II milestone #8854 “Assessment of Data-Management Infrastructure Needs for Production use of Advanced Machine learning and Artificial Intelligence.”

97 MATHEMATICS AND COMPUTING↗

Implementation of a Bayesian Engine for Uncertainty Analysis

In probabilistic risk assessment, it is important to have an environment where analysts have access to a shared and secured high performance computing and a statistical analysis tool package. As part of the advanced small modular reactor probabilistic risk analysis framework implementation, we have identified the need for advanced Bayesian computations. However, in order to make this technology available to non-specialists, there is also a need of a simplified tool that allows users to author models and evaluate them within this framework. As a proof-of-concept, we have implemented an advanced open source Bayesian inference tool, OpenBUGS, within the browser-based cloud risk analysis framework that is under development at the Idaho National Laboratory. This development, the “OpenBUGS Scripter” has been implemented as a client side, visual web-based and integrated development environment for creating OpenBUGS language scripts. It depends on the shared server environment to execute the generated scripts and to transmit results back to the user. The visual models are in the form of linked diagrams, from which we automatically create the applicable OpenBUGS script that matches the diagram. These diagrams can be saved locally or stored on the server environment to be shared with other users.

99 GENERAL AND MISCELLANEOUS↗

RESCue Model (RESCue Experiment and Model) [SWR-24-84]

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of transmission-connected hybrid renewable energy systems, consisting of a combination of wind, solar, and/or energy storage equipment, against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. The development of hybrid reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. The research thrusts for the project included (i) development of hybrid reference architectures and (ii) a cyber-resilient design framework for hybrid energy systems. The reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. A demonstration experiment was developed for one of the architectures using NREL's Cyber Range resources. This experiment configuration, deployable using open-source tools, is provided here in this repository. Additional models were developed for the wind and solar architectures as well, however the configurations for only the Energy Storage scenario are provided here: https://www.nrel.gov/docs/fy24osti/89921.pdf

Hasandka, Adarsh↗

Recommendations for Radiological Data Assessment Implementation

Since thorough verification, validation, and data quality assessment (DQA) processes may delay incident commanders and elected and appointed officials from making key decisions, the U.S. Department of Homeland Security (DHS) National Urban Security Technology Laboratory (NUSTL) tasked Pacific Northwest National Laboratory (PNNL) to develop tools and guidance for the federal, state, local, tribal, and territorial (FSLTT) responders using research, discussions with select FSLTT responders, and the experiences of subject matter experts in incident response. This report provides NUSTL with recommendations on best practices for verification, validation, and data quality assessment for the data collected by responders during a radiological or nuclear event. The purpose of this report is to inform the development of a DQA toolkit aimed at the needs of data assessors during the response to a radiological incident.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

U.S. and Allied Cyber Security Cooperation in the Indo-Pacific (Workshop Summary)

On March 30, 31, and April 1, 2021, the Center for Global Security Research (CGSR) at Lawrence Livermore National Laboratory (LLNL) hosted a workshop titled "U.S. and allied Cyber Security Cooperation in the Indo-Pacific". This session brought together participants drawn across the policy, military, and private sector in the United States and among allied countries in Europe and the Indo-Pacific. The workshop evaluated threat perceptions, assessed cyber power in a regional context, and explored opportunities for building capacity and trust with allies, partners, and the private sector. The region's cyber threat landscape is marked by increasing malicious activity, with threats persistent and ever-growing. Grounded by this strategic reality, the workshop advocated for 1) a concerted push into the arena of norm setting from the bottom up, 2) an agreed metric by which to assess progress, and 3) the creation of future lines of collaborative effort for the United States and its allies to ensure an open, interoperable, and secure internet.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Eligibility Assessment of Items in the TA-60 Rack Assembly and Alignment Complex Legacy Storage Yard

The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (NA-LA), documented and evaluated seven structures in the Technical Area 60 (TA-60) Rack Assembly and Alignment Complex (RAAC) legacy storage yard at Los Alamos National Laboratory (LANL or Laboratory) for listing in the National Register of Historic Places (National Register). This documentation and evaluation was conducted in compliance with Section 106 of the National Historic Preservation Act of 1966, as amended; the Code of Federal Regulations (36 CFR 800); the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos New Mexico (PA)1; and A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (LANL’s Cultural Resources Management Plan (2017). NA-LA makes the following National Register eligibility determinations: la cuna; the rack transporter (jeep, rack trailer, and steering dolly); the Mexia diagnostic rack; the Mexia device canister; the Mexia device mounting stand; and the Mexia target stand are eligible for listing in the National Register, and the second steering dolly is not eligible for listing in the National Register. This National Register evaluation was completed because LANL proposes to develop a consolidated waste facility in TA-60 next to the former RAAC. Across 3.56 acres, LANL proposes to construct an 8,000-square-foot, pre-engineered waste storage building; a 1,500-square-foot office/warehouse building; and 28,500 square feet of covered storage. The development will also include access control features and fencing, parking spaces, and utilities. Additionally, the Laboratory will continue to use the southern part of TA-60-0017 and reuse TA-60-0086 and TA-60-0324 in the development. The consolidated waste facility will operate as a central accumulation area—storing universal waste, mixed low-level (radioactive) waste, hazardous chemicals, and New Mexico special waste—until the waste can be shipped off site.

99 GENERAL AND MISCELLANEOUS↗

Thermal Assessment of OSIRIS-REx OVIRS Cryogenic Instrument During Flight System TVAC Test and in Flight

The Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) Visible and Infrared Spectrometer (OVIRS) is a cryogenic instrument. At the Outbound Cruise nominal spacecraft attitude, sunlight impinges on several multilayer insulation blankets on the forward deck. It is reflected or scattered to other components on the deck. This solar illumination adds heat load to the OVIRS, and causes its detector temperature to exceed the 105K maximum operating allowable flight temperature limit by 0.8K. During the flight system thermal vacuum test, the solar simulator beam reflected or scattered from the test fixtures to the OVIRS added non-flight heat load. The detector temperature was 9K warmer than that in flight. At those temperatures, the science data was acceptable, despite its quality was not as high as that of 105K or colder.

"OSIRIS-REx; OVIRS; cryogenic instrument; parasiti↗