Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Magnetic configuration scans during divertor operation of Wendelstein 7-X

Wendelstein 7-X (W7-X) (Greifswald, Germany) is an advanced stellarator, which uses the modular coil concept to realize a magnetic configuration optimized for fusion-relevant plasma properties. The magnet system of the machine allows a variation of the rotational transform (iota) at the boundary. In the latest W7-X operational phase a dedicated configuration scan has been performed varying the rotational transform between magnetic configurations with iota = 5/4 and iota = 5/5 at the boundary. This paper presents an overview of the experiments and of the main results with respect to confinement and stability. The main observation is an increase of the plasma energy in several intermediate configurations of the scan when the 5/5-islands are close to the plasma boundary but still inside the last-closed-flux-surface. In addition, these configurations showed marked MHD-activity with a crashing behavior related to the 5/5-islands. The corresponding mode amplitude was correlated with the size of the internal 5/5 islands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning probe spectroscopy of sulfur vacancies and MoS 2 monolayers in side-contacted van der Waals heterostructures

We investigate the interplay between vertical tunneling and lateral transport phenomena in electrically contacted van der Waals heterostructures made from monolayer MoS 2 , hBN, and graphene. We compare data taken by low-temperature scanning tunneling spectroscopy to results from room-temperature conductive atomic force spectroscopy on monolayer MoS 2 with sulfur vacancies and with varying hBN layers. We show that for thick hBN barrier layers, where tunneling currents into the conductive substrate are suppressed, a side-contact still enables addressing the defect states in the scanning tunneling microscopy via the lateral current flow. Few-layer hBN realizes an intermediate regime in which the competition between vertical tunneling and lateral transport needs to be considered. The latter is relevant for device structures with both a thin tunneling barrier and a side-contact to the semiconducting layers.

36 MATERIALS SCIENCE↗

A Purely Poisson-based Approach to Estimating Audible Scan Survey Sensitivities

Several endeavors have been made over the years to estimate the sensitivity of audible scan surveys. Some estimates involved certain factors of the background count rate, while others involved calculations utilizing parameters pulled from the normal (Gaussian) distribution, regardless of background count rate. This paper discusses the results of a purely Poisson-based calculational method for the determination of appropriate decision levels and affiliated detection limits associated with health physics audible scan surveys. Comparisons are made to the other approaches and to empirical tests, where available. Although agreement with previous estimates can be had over limited ranges of background count rate, order-of-magnitude differences are possible outside of those ranges. The previous estimates are generally conservative at the higher count rates yet quite nonconservative at the lowest count rates. Several real-life operational examples are provided that illustrate the approach.

47 OTHER INSTRUMENTATION↗

Scanning tunneling shot-noise spectroscopy in Kondo systems

Using a large- N theory in combination with the Keldysh nonequilibrium Green's function formalism, we investigate the current, differential conductance, zero-frequency shot noise, and Fano factor as measured by scanning tunneling shot-noise spectroscopy (STSNS) using a scanning tunneling microscope (STM) near single Kondo impurities and in Kondo lattices. We show that the Fano factor F exhibits a characteristic bias dependence arising from Kondo screening that is similar to the Kondo resonance observed in the differential conductance. Moreover, the line shape of F is strongly dependent on the ratio of the tunneling amplitudes for electron tunneling from the STM tip into the conduction band and electronic levels of the magnetic adatoms. We demonstrate that the Fano factor can be enhanced or suppressed due to interference effects and as such, is not only a sensitive probe for the correlation effects arising from Kondo screening, but also for quantum interference between tunneling electrons. We identify a correlation between the form of the differential conductance and the Fano factor that could be tested in future STSNS experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of rutile transition metal oxide (110) surface terminations by scanning tunneling microscopy contrast reversal

The surfaces of rutile transition-metal oxides (TMO 2 ) are widely investigated for catalysis, photoelectrochemical solar cells, memristors, and supercapacitors, but their structures have remained controversial. Here we employ density functional theory to predict that a universal behavior of metallic TMO 2 surfaces, i.e., the stoichiometric TMO 2 surfaces, exhibit a contrast reversal in simulated scanning tunneling microscopy (STM) images at different scanning biases. The predictions are verified by experimental STM imaging of RuO 2 (110) surfaces and this feature is shown to enable accurate determinations of the TMO 2 (110) surface structures under various conditions. This research provides different insights into the electronic properties of TMO 2 (110) surfaces and offers an effective method to directly map the surface structure and point defects using bias-dependent STM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scanning Josephson spectroscopy on the atomic scale

The Josephson effect provides a direct method to probe the strength of the pairing interaction in superconductors. By measuring the phase fluctuating Josephson current between a superconducting tip of a scanning tunneling microscope and a BCS superconductor with isolated magnetic adatoms on its surface, we demonstrate that the spatial variation of the pairing order parameter can be characterized on the atomic scale. This system provides an example where the local pairing potential suppression is not directly reflected in the spectra measured via quasiparticle tunneling. Spectroscopy with such superconducting tips also shows signatures of previously unexplored Andreev processes through individual impurity-bound Shiba states. Furthermore, the atomic resolution achieved here establishes scanning Josephson spectroscopy as a promising technique for the study of novel superconducting phases.

Andreev reflection↗

Simultaneous X-ray fluorescence and scanning X-ray diffraction microscopy at the Australian Synchrotron XFM beamline

Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed raster-scanning synchrotron serial microcrystallography with a high-precision piezo-scanner

The Frontier Microfocus Macromolecular Crystallography (FMX) beamline at the National Synchrotron Light Source II with its 1 µm beam size and photon flux of 3 × 10 12 photons s −1 at a photon energy of 12.66 keV has reached unprecedented dose rates for a structural biology beamline. The high dose rate presents a great advantage for serial microcrystallography in cutting measurement time from hours to minutes. To provide the instrumentation basis for such measurements at the full flux of the FMX beamline, a high-speed, high-precision goniometer based on a unique XYZ piezo positioner has been designed and constructed. The piezo-based goniometer is able to achieve sub-100 nm raster-scanning precision at over 10 grid-linepairs s −1 frequency for fly scans of a 200 µm-wide raster. The performance of the scanner in both laboratory and serial crystallography measurements up to the maximum frame rate of 750 Hz of the Eiger 16M's 4M region-of-interest mode has been verified in this work. This unprecedented experimental speed significantly reduces serial-crystallography data collection time at synchrotrons, allowing utilization of the full brightness of the emerging synchrotron radiation facilities.

43 PARTICLE ACCELERATORS↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular beam epitaxial growth and scanning tunneling microscopy studies of the gallium rich trench line structure on N-polar w-GaN( 000 1 ¯ )

In addition to the usual set of the well-known reconstructions that have been observed on the N-polar GaN surface, namely 1×1, 3×3, 6×6, and c(6×12), an additional structure is occasionally seen at high Ga coverage, which can extend over a large area of the surface. This structure, which is referred to as trench line structure, is partially ordered and consists of parallel-running dark (trench) lines separating wide and narrow strips of atomically ordered regions. There are also randomly placed defects interrupting the ideal ordering. Reflection high energy electron diffraction and scanning tunneling microscopy in ultrahigh vacuum are applied to investigate this trench line structure on samples prepared using molecular beam epitaxy. It is found that the trench line structure results from annealing the Ga-rich c(6×12) at high temperature followed by quenching to room temperature. By careful comparison of the scanning tunneling microscopy images with those from neighboring c(6×12) regions, it is found that the trench line structure can be decomposed into subunits of the c(6×12). Using these subunits, some simple models for the trench line structure are created. It is proposed that the trench line structure is composed of two primary c(6×12) subunits consisting of first and second layer Ga adatoms and that the trench lines are regions devoid of Ga adatoms, going down to the Ga adlayer.

36 MATERIALS SCIENCE↗

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials↗

SU-E-T-267: Proton Pencil Beam Scanning for Mediastinal Lymphoma: 4-Dimensional Feasibility Study

Purpose: To assess the feasibility of proton pencil beam scanning (PBS) for the treatment of mediastinal lymphoma. Methods: A group of 6 patients were planned using an anterior field with PBS. Spots with ∼5 mm σ were used for all patients, while large spots (∼10 mm σ) were employed for patients with motion perpendicular to the beam (≥5 mm). We considered volumetric repainting such that, in each fraction, the same field would be delivered twice. Four-dimensional dose was calculated on initial and verification 4-dimensional computed tomography (4D-CT) scans (2—3) based on respiratory trace and beam delivery sequence. This was implemented by binning the spots into separate plans on each 4D-CT phase respectively. Four starting phases were sampled for each painting and 4 energy switching times (0.5 s, 1 s, 3 s, and 5 s) were tested, resulting in 2560 dose distributions for the cohort. Plan robustness was measured for target and critical structures in terms of the percentage difference between delivered dose and planned dose. Results: For 5 of the 6 patients, the ITV (internal target volume) D 98% was degraded by <3% (standard deviations ∼ 0.1%) when averaged over the whole course (up to 5% per fraction). Deviations of mean lung dose, heart maximum dose, and cord maximum dose were within 5% of prescribed dose. For one patient with motion perpendicular to the beam (up to 5 mm), the degradation of ITV D 98% was 9% over the whole course (12% per fraction), which was mitigated to 1% (3% per fraction) by employing large spots and repainting. No significant difference in coverage was observed for different energy switching times. Conclusion: This feasibility study demonstrates that, for mediastinal lymphoma, the PBS plan robustness can be maintained during delivery when target motion is measured and volumetric repainting and/or large spots are employed. This work was supported by Ion Beam Application.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-J-06: The Impact of CT-Scan Energy On Range Uncertainty in Proton Therapy Planning

Purpose: To investigate the impact of tube potential (kVp) on the CTnumber (HU) to proton stopping power ratio (PSPR) conversion table; the range uncertainty and the dosimetric change introduced by a mismatch in kVp between the CT and the HU to PSPR table used to calculate dose are analyzed. Methods: A CIRS CT-ED phantom was scanned with a Philips Brilliance 64-slice scanner under 90kVp and 120kVp tube potentials. Two HU to PSPR curves were then created. Using Eclipse (Varian) a treatment plan was created for a single beam in a water phantom (HU=0) passing through a wedge-shaped heterogeneity (HU=1488). The dose was recalculated by changing only the HU to PSPR table used in the dose calculation. The change in range (the distal 90% isodose line) relative to a distal structure was recorded as a function of heterogeneity thickness in the beam. To show the dosimetric impact of a mismatch in kVp between the CT and the HU to PSPR table, we repeated this procedure using a clinical plan comparing DVH data. Results: The HU to PSPR tables diverge for low-density bone and higher density structures. In the phantom plan, the divergence of the tables results in a change in range of ~1mm per cm of bone in the beam path for the HU used. For the clinical plan, a mismatch in kVp showed a 28% increase in mean dose to the brainstem along with a 10% increase in maximum dose to the brainstem center. Conclusion: A mismatch in kVp between the CT and the HU to PSPR table can introduce significant uncertainty in the proton beam range. For dense bone, the measured range uncertainty is about 1mm per cm of bone in the beam. CT-scan energy verification should be employed, particularly when high-density media is in the proton beam path.

60 APPLIED LIFE SCIENCES↗

MO-C-18C-01: Radiation Risks at Level of Few CT Scans: How Real?- Science to Practice

There are controversies surrounding radiation effects in human population in the range of radiation doses encountered by patients resulting from one to several CT scans. While it is understandable why the effects from low levels of diagnostic radiation are controversial, the situation is complicated by the media which may distort the known facts. There is need to understand the state of science regarding low-level radiation effects and also to understand how to communicate the potential risk with patients, the public and media. This session will seek to come to a consensus in order to speak with one voice to the media and the public. This session will review radiation effects known so far from a variety of exposed groups since the nuclear holocaust, provide clarification where effects are certain and where they are not, at what level extrapolation is the only way and at what level there is weak but agreeable acceptance. We will depict where and why there is agreement among organizations responsible for studying radiation effects, and how to deal with situations where effects are uncertain. Specific focus on radiation effects in children will be provided.Finally, the session will attempt to bridge the communication gap from the science to how to be an effective communicator with patients, parents, and media about ionizing radiation. Learning Objectives: To have a clear understanding about certainties and uncertainties of radiation effects at the level of a few CT scans To understand the results and limitations from 3 major pediatric CT scientific studies on childhood exposures published recently. To understand successful strategies used in risk communication.

60 APPLIED LIFE SCIENCES↗

TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

TH-C-BRD-09: Successes and Limitations of Online Range Adaptive Spot Scanning Proton Therapy for NSCLC

Purpose: To determine the ability to adapt discrete spot-scanning proton therapy (SSPT) plans based on geometric changes of anatomy to minimize normal tissue dose and maintain target coverage. Methods: We developed and tested a range-correction algorithm to compensate for anatomy changes in SSPT with correction factors for target lateral size changes and energy scaling. This algorithm adjusts the energy of each spot from the original optimized treatment plan to match the new daily anatomy based on water equivalent path-length. To correct for the lateral target size changes, the peripheral spots were scaled based on phantom studies with variable target size. For energy change corrections, alternative cumulative scaling factor lookup tables were generated based on calculated central-axis and integral depth dose calculations for different energies. These various adaptive algorithms were performed on 7 lung cancer patients that were previously treated with proton therapy and who required at least one adaptive intervention. Single-field optimized SSPT plans were generated for these patients with clinical beam angles. Dose-volume histogram metrics were obtained for these patients for both the non-adaptive and the different adaptive plans applied to the last available weekly CT scan. Results: The doses to normal tissue were largely reduced for the spinal cord (Dmax), total lung (V20Gy), and contralateral lung (V20Gy) for all different methods of adaptive planning. With both corrections applied, the average changes for these metrics were −6.2Gy, −2.7%, and −4.9%, respectively. The same method generated unacceptably high target hot spots with average target V110% increase of 12.3%. Conclusion: Adaptive methods based on direct adjustments to proton range can reduce normal tissue doses under large anatomical changes but are insufficient in achieving clinically acceptable target doses and generate unacceptably sizeable hot spots. Adaptive planning methods for proton therapy will likely necessitate some aspect of reoptimization for acceptable clinical utility.

60 APPLIED LIFE SCIENCES↗

Comparison between target margins derived from 4DCT scans and real-time tumor motion tracking: Insights from lung tumor patients treated with robotic radiosurgery

Purpose: A unique capability of the CyberKnife system is dynamic target tracking. However, not all patients are eligible for this approach. Rather, their tumors are tracked statically using the vertebral column for alignment. When using static tracking, the internal target volume (ITV) is delineated on the four-dimensional (4D) CT scan and an additional margin is added to account for setup uncertainty [planning target volume (PTV)]. Treatment margins are difficult to estimate due to unpredictable variations in tumor motion and respiratory pattern during the course of treatment. The inability to track the target and detect changes in respiratory characteristics might result in geographic misses and local tumor recurrences. The purpose of this study is to develop a method to evaluate the adequacy of ITV-to-PTV margins for patients treated in this manner. Methods: Data from 24 patients with lesions in the upper lobe (n = 12), middle lobe (n = 3), and lower lobe (n = 9) were included in this study. Each patient was treated with dynamic tracking and underwent 4DCT scanning at the time of simulation. Data including the 3D coordinates of the target over the course of treatment were extracted from the treatment log files and used to determine actual target motion in the superior–inferior (S–I), anterior–posterior (A–P), and left–right (L–R) directions. Different approaches were used to calculate anisotropic and isotropic margins, assuming that the tumor moves as a rigid body. Anisotropic margins were calculated by separating target motion in the three anatomical directions, and a uniform margin was calculated by shifting the gross tumor volume contours in the 3D space and by computing the percentage of overlap with the PTV. The analysis was validated by means of a theoretical formulation. Results: The three methods provided consistent results. A uniform margin of 4.5 mm around the ITV was necessary to assure 95% target coverage for 95% of the fractions included in the analysis. In the case of anisotropic margins, the expansion required in the S–I direction was larger (8.1 mm) than those in the L–R (4.9 mm) and A–P (4.5 mm) directions. This margin accounts for variations of target position within the same treatment fraction. Conclusions: The use of bony alignment for CyberKnife lung stereotactic body radiation therapy requires careful considerations, in terms of the potential for increased toxicity or local miss. Our method could be used by other centers to determine the adequacy of ITV-to-PTV margins for their patients.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP1-05: A Framework for the Analytic Calculation of Patient-Specific Dose Distribution Due to CBCT Scan for IGRT

Purpose: To investigate the feasibility of an analytic framework to estimate patients’ absorbed dose distribution owing to daily cone-beam CT scan for image-guided radiation treatment. Methods: To compute total absorbed dose distribution, we separated the framework into primary and scattered dose calculations. Using the source parameters such as voltage, current, and bowtie filtration, for the primary dose calculation, we simulated the forward projection from the source to each voxel of an imaging object including some inhomogeneous inserts. Then we calculated the primary absorbed dose at each voxel based on the absorption probability deduced from the HU values and Beer’s law. In sequence, all voxels constructing the phantom were regarded as secondary sources to radiate scattered photons for scattered dose calculation. Details of forward projection were identical to that of the previous step. The secondary source intensities were given by using scatter-to- primary ratios provided by NIST. In addition, we compared the analytically calculated dose distribution with their Monte Carlo simulation results. Results: The suggested framework for absorbed dose estimation successfully provided the primary and secondary dose distributions of the phantom. Moreover, our analytic dose calculations and Monte Carlo calculations were well agreed each other even near the inhomogeneous inserts. Conclusion: This work indicated that our framework can be an effective monitor to estimate a patient’s exposure owing to cone-beam CT scan for image-guided radiation treatment. Therefore, we expected that the patient’s over-exposure during IGRT might be prevented by our framework.

60 APPLIED LIFE SCIENCES↗