At least 937 records · Page 52

Knowledge Management in Nuclear Liabilities Regulation in the UK - 18155

Within the UK's nuclear safety regulator (Office for Nuclear Regulation; ONR) nuclear liabilities regulation addresses the safe management of radioactive waste, decommissioning and land quality through a facility's lifetime. Higher activity radioactive waste (HAW) could be stored on site for up to 150 years prior to disposal, Magnox decommissioning sites are planned to be in Care and Maintenance for up to 70 years and Sellafield decommissioning is not planned to be complete until after 2100. The long timescales over which decommissioning occurs and radioactive waste is managed is a challenge to maintaining a suitable level of knowledge to effectively and efficiently regulate nuclear liabilities activities. There is a danger that implicit knowledge accumulated over decades could be lost as people retire. Effective knowledge capture and transfer are key elements in maintaining a workforce with the capacity and capability to deliver high levels of nuclear safety, given the demographics of the UK nuclear industry. Maintenance of recorded information over long timescales with changing technologies is necessary to allow safe storage and disposal of waste and intelligent response to incidents. As the safety regulator, ONR's ability to influence improvement in nuclear safety relies on our inspectors having access to high quality knowledge. The ONR Strategy 2016-2020 [1,2] commits to continue to recruit, retain and develop staff so that we have a core workforce with the capacity and capability to deliver high quality, enabling nuclear regulation. Over the next 30 years, the UK plans to develop a geological disposal facility and UK EDF power stations will transition into decommissioning. The ONR Knowledge Management Strategy sets out the activities planned to maintain specialist knowledge to support staff development and build organisational resilience. Guidance on waste management is given in 'The management of higher activity radioactive waste on nuclear licensed sites' (referred to as the Joint Guidance [3]) published by ONR and the UK environmental regulators. It includes our expectations for managing information and records relating to radioactive waste, and introduces the concept of Radioactive Waste Management Cases (RWMCs). Our expectation is that knowledge and records must both be managed and transferred in such a way that future licensees are properly equipped to ensure that waste continues to be managed in a manner that prevents or minimises hazards to human health and the environment. RWMCs are an effective vehicle for demonstrating how the key elements of long-term safety and environmental performance will be delivered over the life cycle of the waste. They give a history of how the waste has been managed, capturing information and change over time. This paper will look at the challenges to managing knowledge in the UK nuclear industry, focusing on the safe management of radioactive waste, decommissioning and land quality. It will look at the problems faced by both licensees and ONR, drawing out common challenges. The paper will outline the approach taken within ONR to capture and communicate waste management and decommissioning knowledge and experience. Finally, it will look at how ONR regulates and influences how knowledge and records are dealt with in the industry to ensure safe nuclear liabilities management in the long term. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of Lead-210 Data Documents Benefits in Proactively Understanding TENORM Deposition - 18515

Radioactive decay of naturally occurring Radon-222 present in just-produced natural gas can lead to deposition of its radiogenic daughter, Lead-210, and subsequent radiogenic progeny within natural gas handling, treatment, and distribution facilities. Worker safety issues and disposal challenges arise when these accumulate to radiologically problematic activity levels. This is due to the 22.3-year half-life of Lead-210, allowing for multi-decade period of accumulation to occur and to persist, even after facility operations have ceased. Due to the far shorter half-lives of Lead-210 radiogenic progeny, especially that of Polonium-210, secular equilibrium within the Lead-210-Bismuth-210-Polonium-210 decay chain is quickly approached during facility operations and achieved after facility operations end. Lead-210 that accumulates in pipe scale can complicate any subsequent intrusive facility modifications, such as disassembly and dismantlement, potentially exposing workers to adverse radioactivity and impeding recycling and/or disposal of radiologically impacted equipment or other material. Experience has shown it is not strictly the presence of Lead-210 that is problematic but rather its 'unexpected' presence when this Technologically Enhanced Naturally Occurring Radioactive Material (TENORM) is discovered during intrusive work not incorporating radiological health and safety and material handling plans. Conversely, when implementing a program that proactively considers the potential for Lead-210, this form of TENORM simply becomes another 'special waste' that can be safely, efficiently, and effectively addressed during a decommissioning effort, without associated adverse worker exposures, project cost over-runs, and schedule delays. This paper will discuss how proactive radioactive scanning quickly and safely identified Lead-210 and its radiogenic progeny within a natural gas sweetening and compressor station located in northern Montana, a portion of which was undergoing decommissioning, aiding in safe and compliant material handling and recycling. The location of this operation necessitated that the decommissioning program be completed on schedule to prevent weather-related impacts due to the onset of adverse winter conditions. Further, the radioactive data acquired during this project will be shown to provide important insight into historic behavior of Lead-210 in terms of its disposition and its more recent decay. From these data, it became possible to back-model the average activity of Radon-222 within the natural gas being processed during the life of the operation, how the estimated Radon-222 activity within the processed natural gas conformed to measured Radon-222 at various other natural gas fields, and how this information can be leveraged in developing safe and successful plans for future intrusive work at this and companion site operations. This presentation will also note the apparent preferential accumulation of Lead-210 within both rubber-based materials, such as gaskets and seals, and grease-based products found within natural gas flow lines. Thoughts regarding processes that may lead to this finding will be explored. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A quantitative method to determine the region not influenced by injected interstitial and surface effects during void swelling in ion-irradiated metals

We propose and demonstrate a microstructurally-based experimental method to quantitively determine the depth regions in self-ion-irradiated metals that are affected by the injected interstitial effect and various surface effects, focusing on the choice of safe analysis zones to minimize the impact of these phenomena. The goal is to define the depth ranges where extracted data can be confidently applied to ion-neutron correlations for reactor application. Since ion energies in the range of 1–5 MeV are most frequently employed by the radiation effects community, irradiations were conducted at four energies in this range, all proceeding at 475 °C. The experiment was conducted on relatively pure single crystal iron to focus only on physical phenomena, avoiding the influence of possibly confounding chemical or segregation processes. Care was also taken to minimize the influence of other physical factors such as crystalline orientation. It was shown that, at 475 °C, ion energies of ≤1 MeV were too shallow in penetration and did not yield a safe depth range, but irradiations at 2.5 MeV and above yielded useful safe zones with predicted swelling behavior becoming independent of ion energy. The surface-affected zone width was found to be roughly twice that of the void-denuded zone width and to be independent of accumulated displacement dose. The largest injected-interstitial effect arises from the injected interstitial depression of void nucleation and growth. The interstitial-affected region starts at about one half of the projected range and does not show any “spreading” of its influence in depth as the peak damage level increases from 50 to 100 dpa. This study provides some confidence that enhances the credibility of ion simulation when applied to prediction of void swelling in neutron environments.

36 MATERIALS SCIENCE↗

Predicting Cement-Sheath Integrity with Consideration of Initial State of Stress and Thermoporoelastic Effects

In conventional wellbore-integrity analysis, the cement sheath’s initial state of stress and transient thermoporoelastic effects are often neglected. However, the initial state of stress is prerequisite information for accurately predicting the safe operating conditions that prevent a cemented well from being damaged. In addition, transient thermoporoelastic effects can have a profound effect on when damage will occur. Here in this paper, we propose a model that includes these effects to predict the safe operating pressures and temperatures that will prevent cement-sheath failure. For the initial state of stress, we proposed an empirical model using measurements. Subsequent stress changes are evaluated by a fully coupled transient thermoporoelastic model to analyze the mechanical behavior of the cement sheath. We predict the safe operating envelope (SOE) for shear, tensile, and debonding cement-sheath failures caused by pressure and temperature perturbations after the cement sets. Our model predicts that pore pressure is a key factor for cement failure, especially for rapid temperature changes. If the formation is low permeability, the transient pore pressures are amplified, causing the risk of damage to increase. Compared with conventional thermoelastic models, the thermoporoelastic model predicts a smaller SOE when heating the internal casing fluid and a larger envelope when cooling the internal casing fluid. Finally, the heating rate was considered with respect to field applications. The heating rate was also considered, and slower heating/cooling rates can prevent damage to the cement sheath. Finally, the thermoporoelastic model was applied to explain several laboratory and field experiments and achieved good matches.

02 PETROLEUM↗

NASA's Secured Advanced Federated Environment

In 1999, a NASA-wide team initially set out to create a collaborative environment to enable NASA's scientists and engineers to share information and tools across NASA locations and with world-wide partners. This paper describes the team's development process and solutions in resolving conflicting security issues of building a complex intra/inter-enterprise collaborative system. Based on the federated, hierarchical, compartmentalized principles, the Secured Advanced Federated Environment (SAFE) developed by the team is becoming a foundational element for building a collaborative infrastructure for NASA. This paper also introduces the concept of a Micro Security Domain which can achieve the balance between the need to collaborate and the need to enforce enterprise and local security rules. SAFE'S federated security concepts enables networks to be formed around the functional/security requirements. With the SAFE technologies and approaches, security will not be an afterthought of the enterprise network design.

network designs↗

Design Concepts to Meet EASA SC-VTOL-01 Single Failure Criteria

The objective of the current work is to discuss European Union Aviation Safety Agency (EASA) SC-VTOL-01 single failure criteria, VTOL.2250(c). Prior studies have developed concept distributed propulsion and flight control (DPFC) system architectures and found they comply with EASA SC-VTOL-01 probabilistic failure criteria, VTOL.2510(a). Prior work developed two all-electric DPFC systems utilized in a quadrotor concept aircraft developed by the National Aeronautics and Space Administration (NASA); one uses interconnecting shafts and gearboxes to interconnect redundant motors with each rotor system and the other uses gearboxes to connect redundant motors locally, near each rotor. Common between the two electric DPFC systems were rotor shafts, epicyclic systems, and motors. The current work explores Category I failures in drive systems, relevant research to support fail-safe design practices for gear systems, research and adjacent industry trends in motor fail-safety and reliability, and proposed design concepts to comply with VTOL.2250(c). Continued research in fail-safe design concepts and design guidance will benefit eVTOL and conventional rotorcraft, alike. Continued research in these areas will benefit eVTOL certification against SC-VTOL-01, and could optimistically translate to more widespread adoption of similar fail-safe design concepts into new rotorcraft designs certified against CS-29.

Rotorcraft↗

An overview of the Department of Energy's CarbonSAFE Initiative: Moving CCUS toward commercialization

The U.S. Department of Energy (DOE) Office of Fossil Energy (FE) National Energy Technology Laboratory (NETL) Carbon Storage Program helps develop technologies that safely and permanently store carbon dioxide (CO 2 ) without adversely impacting natural resources or hindering economic growth. Since 1997, the program has significantly advanced carbon capture, utilization, and storage (CCUS) science and technology, with more than 10.5 million metric tons (MMT) of CO 2 safely stored. However, key gaps in experience and knowledge remain (e.g., the technology, expertise, and processes needed to safely characterize and monitor 50+ MMT-scale geologic CO 2 storage sites). DOE's Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative (launched in FY16) is beginning to address this gap. The CarbonSAFE Initiative currently consists of 13 projects in Phase I: Integrated Carbon Capture and Storage (CCS) Pre-Feasibility and six projects in Phase II: Storage Complex Feasibility. Here this article includes the latest updates from the CarbonSAFE Initiative.

01 COAL, LIGNITE, AND PEAT↗

The presence of fecal test soil protects bacteria during cleaning/disinfection

Abstract Reusable medical devices (RMDs) must be reprocessed between uses to render them safe for each use and each patient. Cleaning used devices removes organic and inorganic soil making them either safe for reuse or ready for disinfection/sterilization depending on the device. Although cleaning is an important step in a RMD's life cycle, it is not always a priority during device design. In addition, when performing cleaning validation, it is recommended that the manufacturer takes into consideration, what the most appropriate or worst case conditions are in terms of type of soil or the presence of bacteria. This study compared the ability of three different cleaning/disinfecting agents (water, alcohol, and bleach) to remove bacteria and fecal test soil from two different polymers: polypropylene and ultrahigh molecular weight polyethylene (UHMWPE) with two different roughness. There were some differences in the effects of the cleaning/disinfecting agents, the materials, and the roughness depending on the particular circumstances. However, the most consistent effect on the removal of bacteria was the presence of soil, which protected the bacteria from being removed. Conversely, the presence of bacteria played little role in the removal of soil. Although the interactions between material type and roughness, soil type, and bacteria are complicated, they should be taken into account during device design and reprocessing validation to create a device that is easy and safe to use. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1706–1710, 2019.

Nandy, Poulomi↗

Subacute safety assessment of recombinant Lactococcus lactis on the gut microbiota of male Sprague–Dawley rats

Abstract BACKGROUND Lactococcus lactis strain pGSMT/MG1363 is a genetically modified microorganism (GMM) that constitutively expresses human metallothionein‐I fusion protein to combine with intracellular lead. Unlike traditional probiotics, pGSMT/MG1363 lacks a history of safe use in food. Administration of microorganism could influence the gut microbial community and consequently confer health benefits or cause disadvantages to the host. To date, little has been done to assess the influence of recombinant strain pGSMT/MG1363 on the stability of gut microbiota. RESULTS Liver, testis and kidney sections of male Sprague–Dawley rats orally administered pGSMT/MG1363 for 6 weeks showed normal structure and no pathological damage. There were no adverse effects on the analyzed serum biochemical parameters between the pGSMT/MG1363 group and the MG1363 group. Principal coordinate analysis showed that, compared with the MG1363 group, the 6‐week‐old fecal gut microbiota of rats fed with pGSMT/MG1363 was not significantly different (Adonis, P = 0.802). pGSMT/MG1363 treatment for 6 weeks did not significantly change the relative abundance of gut microbiota at the phylum and genus levels in comparison with MG1363 treatment. CONCLUSION Compared to the non‐GM strain MG1363 group, administration of the recombinant strain pGSMT/MG1363 for 6 weeks showed no adverse effects on the analyzed physiological parameters and gut microbial compositions of male Sprague–Dawley rats. The results suggested that, in terms of gut microbiota stability, pGSMT/MG1363 could be considered as safe as MG1363, at least for short‐term intake. Further toxicological evaluations still need to be considered before drawing a definite conclusion concerning the safe use of pGSMT/MG1363. © 2021 Society of Chemical Industry.

Chen, Guowei↗

A fragmentation approach to jet flavor

An intuitive definition of the partonic flavor of a jet in quantum chromodynamics is often only well-defined in the deep ultraviolet, where the strong force becomes a free theory and a jet consists of a single parton. However, measurements are performed in the infrared, where a jet consists of numerous particles and requires an algorithmic procedure to define their phase space boundaries. To connect these two regimes, we introduce a novel and simple partonic jet flavor definition in the infrared. We define the jet flavor to be the net flavor of the partons that lie exactly along the direction of the Winner-Take-All recombination scheme axis of the jet, which is safe to all orders under emissions of soft particles, but is not collinear safe. Collinear divergences can be absorbed into a perturbative fragmentation function that describes the evolution of the jet flavor from the ultraviolet to the infrared. The evolution equations are linear and a small modification to traditional DGLAP and we solve them to leading-logarithmic accuracy. The evolution equations exhibit fixed points in the deep infrared, we demonstrate quantitative agreement with parton shower simulations, and we present various infrared and collinear safe observables that are sensitive to this flavor definition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Endovascular Treatment of Active Splenic Bleeding After Colonoscopy: A Systematic Review of the Literature

Purpose: Colonoscopy is reported to be a safe procedure that is routinely performed for the diagnosis and treatment of colorectal diseases. Splenic rupture is considered to be a rare complication with high mortality and morbidity that requires immediate diagnosis and management. Nonoperative management (NOM), surgical treatment (ST), and, more recently, proximal splenic artery embolization (PSAE) have been proposed as treatment options. The goal of this study was to assess whether PSAE is safe even in high-grade ruptures. Methods: We report two rare cases of post colonoscopy splenic rupture. A systematic review of the literature from 2002 to 2010 (first reported case of PSAE) was performed and the three types of treatment compared. Results: All patients reviewed (77 of 77) presented with intraperitoneal hemorrhage due to isolated splenic trauma. Splenic rupture was high-grade in most patients when grading was possible. Six of 77 patients (7.8 %) were treated with PSAE, including the 2 cases reported herein. Fifty-seven patients (74 %) underwent ST. NOM was attempted first in 25 patients with a high failure rate (11 of 25 [44 %]) and requiring a salvage procedure, such as PSAE or ST. Previous surgery (31 of 59 patients), adhesions (10 of 13), diagnostic colonoscopies (49 of 71), previous biopsies or polypectomies (31 of 57) and female sex (56 of 77) were identified as risk factors. In contrast, splenomegaly (0 of 77 patients), medications that increase the risk of bleeding (13 of 30) and difficult colonoscopies (16 of 51) were not identified as risk factors. PSAE was safe and effective even in elderly patients with comorbidities and those taking medications that increase the risk of bleeding, and the length of the hospital stay was similar to that after ST. Conclusion: We propose a treatment algorithm based on clinical and radiological criteria. Because of the high failure rate after NOM, PSAE should be the treatment of choice to manage grade I through IV splenic ruptures after colonoscopy in hemodynamically stabilized patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solid oxide electrolysis cell and stack testing best practices

Solid oxide electrolyzer (SOE) technology is an emerging method for hydrogen production, noted for its superior electrical efficiency. Despite the significant progress made in recent years, the broad development of SOE technology is often constrained by the necessary and extensive "skill of the craft" required to successfully test simple single cell test articles. This may be linked to the dearth of practical and pragmatic guidance within the literature for safe, reliable, and performant test equipment and test procedures. Researchers at the Idaho National Laboratory (INL) have been actively testing SOEs ranging from button cells to stacks up to 500 kW, in collaboration with industry and other national laboratories. Based on operational experience, INL has developed system design procedures that ensure safe and reliable operation of SOE systems with the level of support required for each test. This paper presents key aspects of SOE stack and system testing, including safe design procedures, balance of plant components design, and specific implementations at INL. Practical design details of reactants, heat, and power management are presented along with lessons learned from the SOE test facility operations at INL.

08 HYDROGEN↗

Hot deformation characterization of duplex low-density steel through 3D processing map development

The high temperature deformation behavior of duplex low-density Fe–18Mn–8Al–0.8C steel was investigated at temperatures in the range of 600–1000 °C. The primary constitutive analysis indicated that the Zener–Hollomon parameter, which represents the coupled effects of temperature and strain rate, significantly varies with the amount of deformation. Accordingly, the 3D processing maps were developed considering the effect of strain and were used to determine the safe and unsafe deformation conditions in association with the microstructural evolution. The deformation at efficiency domain I (900–1100 °C\10{sup −} {sup 2}–10{sup −} {sup 3} s{sup −} {sup 1}) was found to be safe at different strains due to the occurrence of dynamic recrystallization in austenite. The safe efficiency domain II (700–900 °C\1–10{sup −} {sup 1} s{sup −} {sup 1}), which appeared at logarithmic strain of 0.4, was characterized by deformation induced ferrite formation. Scanning electron microscopy revealed that the microband formation and crack initiation at ferrite\austenite interphases were the main causes of deformation instability at 600–800 °C\10{sup −} {sup 2}–10{sup −} {sup 3} s{sup −} {sup 1}. The degree of instability was found to decrease by increasing the strain due to the uniformity of microbanded structure obtained at higher strains. The shear band formation at 900–1100 °C\1–10{sup −} {sup 1} s{sup −} {sup 1} was verified by electron backscattered diffraction. The local dynamic recrystallization of austenite and the deformation induced ferrite formation were observed within shear-banded regions as the results of flow localization. - Graphical abstract: Display Omitted - Highlights: • The 3D processing map is developed for duplex low-density Fe–Mn–Al–C steel. • The efficiency domains shrink, expand or appear with increasing strain. • The occurrence of DRX and DIFF increases the power efficiency. • Crack initiation at α/γ interphase and shear banding lead to failure.

36 MATERIALS SCIENCE↗

Study on hot deformation behavior and workability of squeeze-cast 20 vol%SiCw/6061Al composites using processing map

Highlights: • Prasad’s and Murty’s criteria were better than Gegel’s criterion in predicting the flow instability for the composites. • Partial melting and DRX at high temperature and high strain rate improved the workability of the composites. • The softening mechanism changed from DRV to DRX with the increase of deformation temperature and strain rate. • The safe deformation region of the composites was at higher temperature of 450-500°C and higher strain rate of 0.1-1s{sup -1}. • The safe deformation region predicted by processing maps was validated by uniaxial upsetting and two-directional forging. - Abstract: The hot deformation behavior and workability of squeeze-cast 20 vol%SiCw/6061Al composites were investigated by isothermal compression test and development of processing map, which was verified by uniaxial upsetting and two-directional forging of big cylindrical billets. Due to dispersed strengthening caused by SiC whiskers, the activation energy of 20 vol%SiCw/6061Al composites was much higher than the self-diffusion activation energy of pure Al. Both the DMM and MDMM were reliable in predicting the safe deformation regions. The instability regions predicted by the Prasad's and Murty's instability criterion were smaller than the actual ones, while the Gegel's instability criterion was not appropriate in predicting the instability regions of 20 vol%SiCw/6061Al composites. The optimum deformation region was at higher temperature of 450–500 °C and higher strain rate of 0.1–1 s{sup − 1}, in which the compressed samples exhibited perfect surface without cracks and microstructure with few of cavities due to the occurrence of partial melting and dynamic recrystallization. With the increase of deformation temperature and strain rate, the deformation mechanism changed from dynamic recovery to dynamic recrystallization. Squeezing casting technique with high filtration pressure may also contribute to the increase of strain rate of DRX, which was helpful for hot forging of Al matrix composites with high productivity.

36 MATERIALS SCIENCE↗

Preclinical pharmacology and toxicology study of Ad-hTERT-E1a-Apoptin, a novel dual cancer-specific oncolytic adenovirus

Clinical studies have demonstrated that conditionally replicating adenovirus is safe. We constructed an oncolytic adenovirus, Ad-hTERT-E1a-Apoptin, using a cancer-specific promoter (human telomerase reverse transcriptase promoter, hTERTp) and a cancer cell-selective apoptosis-inducing gene (Apoptin). Ad-hTERT-E1a-Apoptin was proven effective both in vitro and in vivo in our previous study. In this study, the preclinical safety profiles of Ad-hTERT-E1a-Apoptin in animal models were investigated. At doses of 5.0 × 10{sup 8}, 2.5 × 10{sup 9}, and 1.25 × 10{sup 10} viral particles (VP)/kg, Ad-hTERT-E1a-Apoptin had no adverse effects on mouse behavior, muscle cooperation, sedative effect, digestive system, and nervous systems, or on beagle cardiovascular and respiratory systems at 5.0 × 10{sup 8}, 2.5 × 10{sup 9}, and 1.25 × 10{sup 10} VP/kg doses. In acute toxicity tests in mice, the maximum tolerated dose > 5 × 10{sup 10} VP/kg. There was no inflammation or ulceration at the injection sites within two weeks. In repeat-dose toxicological studies, the no observable adverse effect levels of Ad-hTERT-E1a-Apoptin in rats (1.25 × 10{sup 10} VP/kg) and beagles (2.5 × 10{sup 9} VP/kg) were 62.5- and 12.5-fold of the proposed clinical dose, respectively. The anti-virus antibody was produced in animal sera. Bone marrow examination revealed no histopathological changes. Guinea pigs sensitized by three repeated intraperitoneal injections of 1.35 × 10{sup 10} VP/mL Ad-hTERT-E1a-Apoptin each and challenged by one intravenous injection of 1.67 × 10{sup 8} VP/kg Ad-hTERT-E1a-Apoptin did not exhibit any sign of systemic anaphylaxis. Our data from different animal models suggest that Ad-hTERT-E1a-Apoptin is a safe anti-tumor therapeutic agent. - Highlights: • We use the rodents and non-rodents animal models to evaluation Ad-hTERT-E1a-Apoptin. • Ad-hTERT-E1a-Apoptin is a safe anti-tumor therapeutic agent. • Demonstrate the safety and feasibility dose of injected Ad-hTERT-E1a-Apoptin.

60 APPLIED LIFE SCIENCES↗

Mobilization and removing of cadmium from kidney by GMDTC utilizing renal glucose reabsorption pathway

Chronic exposure to cadmium compounds (Cd{sup 2+}) is one of the major public health problems facing humans in the 21st century. Cd{sup 2+} in the human body accumulates primarily in the kidneys which leads to renal dysfunction and other adverse health effects. Efforts to find a safe and effective drug for removing Cd{sup 2+} from the kidneys have largely failed. We developed and synthesized a new chemical, sodium (S)-2-(dithiocarboxylato((2S,3R,4R,5R)-2,3,4,5,6 pentahydroxyhexyl)amino)-4-(methylthio) butanoate (GMDTC). Here we report that GMDTC has a very low toxicity with an acute lethal dose (LD50) of more than 10,000 mg/kg or 5000 mg/kg body weight, respectively, via oral or intraperitoneal injection in mice and rats. In in vivo settings, up to 94% of Cd{sup 2+} deposited in the kidneys of Cd{sup 2+}-laden rabbits was removed and excreted via urine following a safe dose of GMDTC treatment for four weeks, and renal Cd{sup 2+} level was reduced from 12.9 μg/g to 1.3 μg/g kidney weight. We observed similar results in the mouse and rat studies. Further, we demonstrated both in in vitro and in animal studies that the mechanism of transporting GMDTC and GMDTC-Cd complex into and out of renal tubular cells is likely assisted by two glucose transporters, sodium glucose cotransporter 2 (SGLT2) and glucose transporter 2 (GLUT2). Collectively, our study reports that GMDTC is safe and highly efficient in removing deposited Cd{sup 2+} from kidneys assisted by renal glucose reabsorption system, suggesting that GMDTC may be the long-pursued agent used for preventive and therapeutic purposes for both acute and chronic Cd{sup 2+} exposure.

60 APPLIED LIFE SCIENCES↗

Optimal management program for asbestos containing building materials to be available in the event of a disaster

Highlights: • The safe management of asbestos is a matter of considerable importance. • There is a lack of literature concerning the development of a program for ACBMs. •A management program for the optimal disposal of ACBMs has been developed. • This program is also available in the event of a post-disaster. - Abstract: The safe management and disposal of asbestos is a matter of considerable importance. A large number of studies have been undertaken to quantify the issue of waste management following a disaster. Nevertheless, there have been few (if any) studies concerning asbestos waste, covering the amount generated, the cost of disposal, and the degree of hazard incurred. Thus, the current study focuses on developing a program for the management of Asbestos Containing Building Materials (ACBMs), which form the source of asbestos waste in the event of a disaster. The study will also discuss a case study undertaken in a specific region in Korea in terms of: (1) the location of ACBM-containing buildings; (2) types and quantities of ACBMs; (3) the cost of ACBM disposal; (4) the amount of asbestos fiber present during normal times and during post-disaster periods; (5) the required order in which ACBM-containing buildings should be dismantled; and (6) additional greenhouse gases generated during ACBM removal. The case study will focus on a specific building, with an area of 35.34 m{sup 2}, and will analyze information concerning the abovementioned points. In addition, the case study will focus on a selected area (108 buildings) and the administrative district (21,063 buildings). The significance of the program can be established by the fact that it visibly transmits information concerning ACBM management. It is a highly promising program, with a widespread application for the safe management and optimal disposal of asbestos in terms of technology, policy, and methodology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗