Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Risk analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

An Assessment of the Efficacy of Launch Collision Avoidance Analysis in Providing Risk Reduction for NASA

The objective of this document is to assess the value of collision on launch assessment (COLA, often referred to as “launch COLA”) practices and provide recommendations regarding its implementation for NASA robotic missions. The scope of this effort is limited to launch COLA screens against catalog objects that are either spacecraft or debris. No modifications to manned safety launch COLA practices are considered in this effort. An assessment of the value of launch COLA can be broken down into two fundamental questions: 1) Does collision during launch represent a significant risk to either the payload being launched or the space environment? 2) Can launch collision mitigation be performed in a manner that provides meaningful risk reduction at an acceptable level of operational impact? While it has been possible to piece together partial answers to these questions for some time, the first attempt to comprehensively address them is documented in reference (a), Launch COLA Operations: an Examination of Data Products, Procedures, and Thresholds, Revision A. This report is the product of an extensive study that addressed fundamental technical questions surrounding launch collision avoidance analysis and practice. The results provided in reference (a) will be cited throughout this document as these two questions are addressed. The premise of this assessment is that in order to conclude that launch COLA is a value-added activity, the answer to both of these questions must be affirmative. A “no” answer to either of these questions points toward the conclusion that launch COLA provides little or no risk mitigation benefit. The remainder of this assessment will focus on addressing these two questions.

launch COLA↗

Innovative Use of Cr(VI) Plume Depictions and Pump-and-Treat Capture Analysis to Estimate Risks of Contaminant Discharge to Surface Water at Hanford Reactor Areas

The Hanford Site nuclear reactor operations required large quantities of high-quality cooling water, which was treated with chemicals including sodium dichromate dihydrate for corrosion control. Cooling water leakage, as well as intentional discharge of cooling water to ground during upset conditions, produced extensive groundwater recharge mounds consisting largely of contaminated cooling water and resulted in wide distribution of hexavalent chromium (Cr[VI]) contamination in the unconfined aquifer. The 2013 Cr(VI) groundwater plumes in the 100 Areas cover approximately 6 km2 (1500 acres), primarily in the 100-HR-3 and 100-KR-4 groundwater operable units (OUs). The Columbia River is a groundwater discharge boundary; where the plumes are adjacent to the Columbia River there remains a potential to discharge Cr(VI) to the river at concentrations above water quality criteria. The pump-and-treat systems along the River Corridor are operating with two main goals: 1) protection of the Columbia River, and 2) recovery of contaminant mass. An evaluation of the effectiveness of the pump-and-treat systems was needed to determine if the Columbia River was protected from contamination, and also to determine where additional system modifications may be needed. In response to this need, a technique for assessing the river protection was developed which takes into consideration seasonal migration of the plume and hydraulic performance of the operating well fields. Groundwater contaminant plume maps are generated across the Hanford Site on an annual basis. The assessment technique overlays the annual plume and the capture efficiency maps for the various pump and treat systems. The river protection analysis technique was prepared for use at the Hanford site and is described in detail in M.J. Tonkin, 2013. Interpolated capture frequency maps, based on mapping dynamic water level observed in observation wells and derived water levels in the vicinity of extraction and injection wells, are developed initially. Second, simulated capture frequency maps are developed, based on transport modelling results. Both interpolated and simulated capture frequency maps are based on operation of the systems over a full year. These two capture maps are then overlaid on the plume distribution maps for inspection of the relative orientation of the contaminant plumes with the capture frequency. To quantify the relative degree of protection of the river from discharges of Cr(VI) (and conversely, the degree of threat) at any particular location, a systematic method of evaluating and mapping the plume/capture relationship was developed. By comparing the spatial relationship between contaminant plumes and hydraulic capture frequency, an index of relative protectiveness is developed and the results posted on the combined plume/capture plan view map. Areas exhibiting lesser degrees of river protection are identified for remedial process optimization actions to control plumes and prevent continuing discharge of Cr(VI) to the river.

Miller, Chuck W.↗

Innovative use of Cr(VI) plume depictions and pump-and-treat capture analysis to estimate risks of contaminant discharge to surface water at Hanford reactor areas - 15315

The Hanford Site nuclear reactor operations required large quantities of high-quality cooling water, which was treated with chemicals including sodium dichromate dihydrate for corrosion control. Cooling water leakage, as well as intentional discharge of cooling water to ground during upset conditions, produced extensive groundwater recharge mounds consisting largely of contaminated cooling water and resulted in wide distribution of hexavalent chromium (Cr[VI]) contamination in the unconfined aquifer. The 2013 Cr(VI) groundwater plumes in the 100 Areas cover approximately 6 km{sup 2} (1500 acres), primarily in the 100-HR-3 and 100-KR-4 groundwater operable units (OUs). The Columbia River is a groundwater discharge boundary; where the plumes are adjacent to the Columbia River there remains a potential to discharge Cr(VI) to the river at concentrations above water quality criteria. The pump-and-treat systems along the River Corridor are operating with two main goals: 1) protection of the Columbia River, and 2) recovery of contaminant mass. An evaluation of the effectiveness of the pump-and-treat systems was needed to determine if the Columbia River was protected from contamination, and also to determine where additional system modifications may be needed. In response to this need, a technique for assessing the river protection was developed which takes into consideration seasonal migration of the plume and hydraulic performance of the operating well fields. Groundwater contaminant plume maps are generated across the Hanford Site on an annual basis. The assessment technique overlays the annual plume and the capture efficiency maps for the various pump and treat systems. The river protection analysis technique was prepared for use at the Hanford site and is described in detail in M.J. Tonkin, 2013. Interpolated capture frequency maps, based on mapping dynamic water level observed in observation wells and derived water levels in the vicinity of extraction and injection wells, are developed initially. Second, simulated capture frequency maps are developed, based on transport modelling results. Both interpolated and simulated capture frequency maps are based on operation of the systems over a full year. These two capture maps are then overlaid on the plume distribution maps for inspection of the relative orientation of the contaminant plumes with the capture frequency. To quantify the relative degree of protection of the river from discharges of Cr(VI) (and conversely, the degree of threat) at any particular location, a systematic method of evaluating and mapping the plume/capture relationship was developed. By comparing the spatial relationship between contaminant plumes and hydraulic capture frequency, an index of relative protectiveness is developed and the results posted on the combined plume/capture plan view map. Areas exhibiting lesser degrees of river protection are identified for remedial process optimization actions to control plumes and prevent continuing discharge of Cr(VI) to the river. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-Unit Considerations for Human Reliability Analysis

This paper uses the insights from the Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) methodology to help identify human actions currently modeled in the single unit PSA that may need to be modified to account for additional challenges imposed by a multi-unit accident as well as identify possible new human actions that might be modeled to more accurately characterize multi-unit risk. In identifying these potential human action impacts, the use of the SPAR-H strategy to include both errors in diagnosis and errors in action is considered as well as identifying characteristics of a multi-unit accident scenario that may impact the selection of the performance shaping factors (PSFs) used in SPAR-H. The lessons learned from the Fukushima Daiichi reactor accident will be addressed to further help identify areas where improved modeling may be required. While these multi-unit impacts may require modifications to a Level 1 PSA model, it is expected to have much more importance for Level 2 modeling. There is little currently written specifically about multi-unit HRA issues. A review of related published research will be presented. While this paper cannot answer all issues related to multi-unit HRA, it will hopefully serve as a starting point to generate discussion and spark additional ideas towards the proper treatment of HRA in a multi-unit PSA.

99 GENERAL AND MISCELLANEOUS↗

CO 2 Sequestration and Enhanced Oil Recovery at Depleted Oil/Gas Reservoirs

This study presents a quantitative evaluation of the operational and technical risks of an active CO 2 -EOR project. A set of risk factor metrics is defined to post-process the Monte Carlo (MC) simulations for statistical analysis. The risk factors are expressed as measurable quantities that can be used to gain insight into project risk (e.g. environmental and economic risks) without the need to generate a rigorous consequence structure, which include (a) CO 2 injection rate, (b) net CO 2 injection rate, (c) cumulative CO 2 storage, (d) cumulative water injection, (e) oil production rate, (f) cumulative oil production, (g) cumulative CH 4 production, and (h) CO 2 breakthrough time. The Morrow reservoir at the Farnsworth Unit (FWU) site, Texas, is used as an example for studying the multi-scale statistical approach for CO 2 accounting and risk analysis. A set of geostatistical-based MC simulations of CO 2 -oil/gas-water flow and transport in the Morrow formation are conducted for evaluating the risk metrics. A response-surface-based economic model has been derived to calculate the CO 2 -EOR profitability for the FWU site with a current oil price, which suggests that approximately 31% of the 1000 realizations can be profitable. If government carbon-tax credits are available, or the oil price goes up or CO 2 capture and operating expenses reduce, more realizations would be profitable.

02 PETROLEUM↗

Tactical Analysis for Calculating Contextual Risk at Boundaries: Summary of Laboratory Directed Research & Development Effort

The Tactical Analysis for Calculating Contextual Risk at Boundaries (TACCRAB) tool is an innovative digital twin (DT) platform and automated risk algorithm designed to transform operational decision-making in structured screening environments, with an initial focus on Southern Border Land Ports of Entry (POEs). The invention provides integration points for advanced artificial intelligence, predictive modeling, and real-time data analysis to produce a comprehensive risk management tool that enables proactive, data-informed security strategies. The core inventive features of TACCRAB center on its unique risk algorithm, which dynamically calculates contextual risk by synthesizing historical data, near real-time streaming data from the checkpoints themselves, and AI-generated predictions. Unlike traditional risk assessment methods, TACCRAB utilizes a DT to provide comprehensive operational insights, allowing stakeholders to visualize, simulate, and optimize checkpoint configurations with unprecedented speed and contextual awareness. TACCRAB's key innovation lies in its ability to combine multiple complex inputs - including technology detection probabilities, resource availability, screening pathway characteristics, and threat actor behavioral patterns - into a unified risk calculation and update these inputs based on changing operational and environmental conditions. By leveraging a DT that continuously updates and learns from linked data, TACCRAB can suggest adaptive mitigation strategies that minimize risk while maintaining operational efficiency. Particularly novel is the platform's approach to decision support, which goes beyond static risk assessment. The DT provides dynamic metrics such as wait times, resource allocation effectiveness, and potential emerging threat scenarios, enabling users to view sophisticated, relevant what-if simulations and optimize checkpoint operations in near real-time. The system's architecture allows for generalized application across different screening environments, such as secure facilities, ports of entry, and soft targets, making it a versatile tool for security and operational management. The invention distinguishes itself through its comprehensive integration of predictive modeling, AI-driven pattern discovery, and user-friendly interface design. By combining these elements, TACCRAB transforms complex risk data into actionable insights, supporting decision-makers at various organizational levels - from booth agents making split-second screening decisions to checkpoint managers optimizing the day's resource allocation to strategic planners managing long-term investments.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Assessment and uncertainty analysis of groundwater risk

Highlights: • Two different sets of index evaluation systems for shallow and deep groundwater were built respectively. • Ordinary kriging was adopted to execute the interpolation estimation. • The synthetic weights were adopted merging the AHP method and PCA method. • The uncertainty of groundwater risk was analyzed by indicator kriging. Groundwater with relatively stable quantity and quality is commonly used by human being. However, as the over-mining of groundwater, problems such as groundwater funnel, land subsidence and salt water intrusion have emerged. In order to avoid further deterioration of hydrogeological problems in over-mining regions, it is necessary to conduct the assessment of groundwater risk. In this paper, risks of shallow and deep groundwater in the water intake area of the South-to-North Water Transfer Project in Tianjin, China, were evaluated. Firstly, two sets of four-level evaluation index system were constructed based on the different characteristics of shallow and deep groundwater. Secondly, based on the normalized factor values and the synthetic weights, the risk values of shallow and deep groundwater were calculated. Lastly, the uncertainty of groundwater risk assessment was analyzed by indicator kriging method. The results meet the decision maker's demand for risk information, and overcome previous risk assessment results expressed in the form of deterministic point estimations, which ignore the uncertainty of risk assessment.

54 ENVIRONMENTAL SCIENCES↗

Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Men With Intermediate-Risk Prostate Cancer: Analysis of Short- and Medium-Term Toxicity and Quality of Life

Purpose: To determine the short- and medium-term effects of a single high-dose-rate brachytherapy fraction of 15Gy and hypofractionated external beam radiation therapy for prostate cancer. Methods and Materials: Eligible patients had localized prostate cancer with a Gleason score of 7 and a prostate-specific antigen (PSA) concentration of <20 ng/ml or a Gleason score of 6 with a PSA concentration of 10 to 20 ng/ml. Patients received high-dose-rate brachytherapy as a single 15-Gy dose, followed by external beam radiation therapy at 37.5Gy in 15 fractions, and were followed prospectively for toxicity (using Common Terminology Criteria for Adverse Events version 3.0), urinary symptoms (using the International Prostate Symptom Score [IPSS]), erectile function (with the International Index of Erectile Function [IIEF]), and health-related quality of life (with the Expanded Prostate Cancer Index Composite [EPIC]). Clinical examinations and PSA measurements were performed at every visit, and prostate biopsies were repeated at 2 years. The trial accrued 125 patients, with a median follow-up of 1.14 years. Results: Acute grade 2 and 3 genitourinary toxicity occurred in 62% and 1.6% of patients, respectively, and acute grade 2 gastrointestinal toxicity occurred in 6.5% of patients. No grade 3 late toxicity has occurred: 47% of patients had grade 2 genitourinary and 10% of patients had grade 2 gastrointestinal toxicity. Median IPSSs rose from 5 at baseline to 12 at 1 month and returned to 7 at 3 months. Of the total number of patients who were initially potent (IIEF, >21), 8% of patients developed mild to moderate dysfunction, and 27% of patients developed severe erectile dysfunction. Baseline EPIC bowel, urinary, and sexual bother scores decreased by 9, 7, and 19 points, respectively, at 1 year. No patient has experienced biochemical failure, and 16 of the first 17 biopsy results showed no malignancy. Conclusions: Treatment is well tolerated in the short and medium term, with low toxicity and encouraging early indicators of disease control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparative analysis of accident risks in fossil, hydro, and nuclear energy chains

This study presents a comparative assessment of severe accident risks in the energy sector, based on the historical experience of fossil (coal, oil, natural gas, and LPG (Liquefied Petroleum Gas)) and hydro chains contained in the comprehensive Energy-related Severe Accident Database (ENSAD), as well as Probabilistic Safety Assessment (PSA) for the nuclear chain. Full energy chains were considered because accidents can take place at every stage of the chain. Comparative analyses for the years 1969-2000 included a total of 1870 severe ({>=} 5 fatalities) accidents, amounting to 81,258 fatalities. Although 79.1% of all accidents and 88.9% of associated fatalities occurred in less developed, non-OECD countries, industrialized OECD countries dominated insured losses (78.0%), reflecting their substantially higher insurance density and stricter safety regulations. Aggregated indicators and frequency-consequence (F-N) curves showed that energy-related accident risks in non-OECD countries are distinctly higher than in OECD countries. Hydropower in non-OECD countries and upstream stages within fossil energy chains are most accident-prone. Expected fatality rates are lowest for Western hydropower and nuclear power plants; however, the maximum credible consequences can be very large. Total economic damages due to severe accidents are substantial, but small when compared with natural disasters. Similarly, external costs associated with severe accidents are generally much smaller than monetized damages caused by air pollution.

01 COAL, LIGNITE, AND PEAT↗

Analysis of radiation risk from alpha particle component of soalr particle events

The Solar Particle Events (SPE) will contain a primary alpha particle component, representing a possible increase in the potential risk to astronauts during an SPE over the often studied proton component. We discuss the physical interactions of alpha particles important in describing the transport of these particles through spacecraft and body shielding. Models of light ion reactions are presented and their effects on energy and Linear Energy Transfer (LET) spectra in shielding are discussed. We present predictions of particle spectra, dose, and dose equivalent in organs of interest for SPE spectra typical of those occurring in recent solar cycles. The large events of solar cycle 19 are found to have substantial increase in biological risk from alpha particles, including a large increase in secondary neutron production from alpha particle breakup.

Cucinotta, F. A.↗

Analysis of radiation risk from alpha particle component of solar particle events

The solar particle events (SPE) will contain a primary alpha particle component, representing a possible increase in the potential risk to astronauts during an SPE over the often studied proton component. We discuss the physical interactions of alpha particles important in describing the transport of these particles through spacecraft and body shielding. Models of light ion reactions are presented and their effects on energy and linear energy transfer (LET) spectra in shielding discussed. We present predictions of particle spectra, dose, and dose equivalent in organs of interest for SPE spectra typical of those occurring in recent solar cycles. The large events of solar cycle 19 are found to have substantial increase in biological risk from alpha particles, including a large increase in secondary neutron production from alpha particle breakup.

NASA Discipline Number 45-10↗

SPAR-H Step-by-Step Guidance

Step-by-step guidance was developed recently at Idaho National Laboratory for the US Nuclear Regulatory Commission on the use of the Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) method for quantifying Human Failure Events (HFEs). This work was done to address SPAR-H user needs, specifically requests for additional guidance on the proper application of various aspects of the methodology. This paper overviews the steps of the SPAR-H analysis process and highlights some of the most important insights gained during the development of the step-by-step directions. This supplemental guidance for analysts is applicable when plant-specific information is available, and goes beyond the general guidance provided in existing SPAR-H documentation. The steps highlighted in this paper are: Step-1, Categorizing the HFE as Diagnosis and/or Action; Step-2, Rate the Performance Shaping Factors; Step-3, Calculate PSF-Modified HEP; Step-4, Accounting for Dependence, and; Step-5, Minimum Value Cutoff.

99 GENERAL AND MISCELLANEOUS↗