Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Recovery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Modeling of reciprocating internal combustion engines for power generation and heat recovery

This paper presents a power generation and heat recovery model for reciprocating internal combustion engines (ICEs). The purpose of the proposed model is to provide realistic estimates of performance/efficiency maps for both electrical power output and useful thermal output for various capacities of engines for use in a preliminary CHP design/simulation process. The proposed model will serve as an alternative to constant engine efficiencies or empirical efficiency curves commonly used in the current literature for simulations of CHP systems. The engine performance/efficiency calculation algorithm has been coded to a publicly distributed FORTRAN Dynamic Link Library (DLL), and a user friendly tool has been developed using Visual Basic programming. Simulation results using the proposed model are validated against manufacturer’s technical data.

combined heat and power, internal combustion engin↗

Enabling thermal efficiency improvement and waste heat recovery using liquid air harnessed from offshore renewable energy sources

A novel approach using decoupled processes to harness offshore renewable energy, from marine hydrokinetics, ocean waves, wind, and solar to produce liquid air, is presented here. Offshore renewables interconnection using submarine medium- and high-voltage direct current technologies are used to produce liquid air that can be transported to end-use locations using repurposed liquefied natural gas tankers. Two important possibilities arise from using the proposed technology. The first possibility allows the integration with conventional thermal cycles to improve efficiency. This approach can be used to leverage efficiencies of thermal systems that have already reached a plateau in the maximum achievable efficiency via design and operation optimization. The second possibility is related to the incorporation of low temperature cycles to recover waste heat from other thermal processes. This is important considering that waste heat accounts for more than 60% of the consumed energy in the United States. A detailed technical description of the complete cycle from cryogen generation to end-use of energy is provided. Estimation of efficiency enhancement for thermal plants using liquid air including waste heat recovery is presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximizing energy efficiency in wastewater treatment plants: A data-driven approach for waste heat recovery and an economic analysis using Organic Rankine Cycle and thermal energy storage

Maximizing energy efficiency through waste heat recovery (WHR) processes is crucial for sustainable and ecofriendly operations across multiple industries, notably in wastewater treatment plants (WWTPs). This work proposes a comprehensive approach for assessing the WHR feasibility in WWTPs, structured in two main objectives. Firstly, an Artificial Neural Network (ANN) model is developed to accurately predict WHR based on operational data, including biogas temperature, biogas pressure, daily production in kWh, and WHR values in kWh th . The second objective focuses on economically evaluating the WHR feasibility based on the estimated WHR values obtained by the ANN model, and then realistically assessing the economic feasibility of integrating the Organic Rankine Cycle (ORC) and Seasonal Thermal Energy Storage (STES) systems. With an application to the As-Samra WWTP located in Jordan, the developed ANN model demonstrates promising results in the validation phase, with a root mean square error (RMSE) of 2206 kWh/day, a mean absolute error (MAE) of 1674 kWh/day, and an R-squared (R 2 ) value of 68%. On the other hand, the economic analysis reveals that an optimal ORC system of 412.14 kW e capacity yields a Net Present Value (NPV) of 2.09 million US dollars, a Levelized Cost of Energy (LCOE) of 0.0749 USD/kWh, a Payback Period (PBP) of 4.8 years, and annual revenues of 428 kUSD. This work also investigates the techno-economic feasibility of integrating ORC-STES. Results indicate that the LCOE and PBP are highly affected by the ORC's capital cost, and integrating STES increases the LCOE to 0.0824 USD/kWh, rendering its integration with ORC infeasible. In conclusion, this study aims to advance the understanding and application of WHR in WWTPs, paving the way for more efficient and sustainable practices in the field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reduction and potential remediation of U(VI) by dithionite at an in-situ recovery mine: Insights gained by δ 238 U

In-situ recovery is a common method of mining U ore. This technique involves injecting an oxidant to oxidize U deposited as insoluble U(IV) to soluble U(VI) and a complexing agent to form mobile U(VI) compounds, which are extracted from mining waters. Unfortunately, U concentrations often remain elevated in groundwater following this mining process. One promising technique to decrease U concentrations to acceptable levels is in-situ remediation where a reductant is injected into the mined area to reduce U(VI) back to insoluble U(IV). Here we assess the efficacy of the chemical reductant dithionite to reduce U(VI) concentrations. While dithionite can reduce environmental Cr(VI), dithionite has previously never been tested for reducing U(VI) in the environment. We determine how effectively dithionite remediates U(VI) contamination using aqueous U concentration and δ 238 U data. U concentrations and δ 238 U decrease during the dithionite experiment, demonstrating that dithionite induces U(VI) reduction. As dithionite is removed by pumping, U concentrations and δ 238 U increase towards background levels, but U(VI) reduction continues for an extended period. In conclusion, measurements demonstrate that re-oxidation and remobilization does not appear to occur due to the reducing condition of groundwater.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact automated apparatus for rapid astatine recovery from nitric acid media: Design, application, and impurity characterization

We report automation of irradiated bismuth target dissolution and astatine recovery from nitric acid media has been achieved at Texas A&M University. This process can be controlled remotely; it does not require any chemical treatment or evaporation of dissolution solution prior to the separation of above-mentioned elements on an extraction chromatography column, making the final product ready within 20 min. The accompanying radio-impurities have been identified and successfully separated from astatine, leading to greater than 99% radiopurity of the desired fractions. The system consists of only one pump and a set of LabVIEW controlled valves, and allows the connection of up to 10 different columns, providing the opportunity to prepare a variety of air dry columns, which can be different column geometries, containing astatine ready for further chemistry or shipment to desired facilities.

42 ENGINEERING↗

Surrogate modeling and optimization of the leaching process in a rare earth elements recovery plant

Critical minerals (CMs) and Rare Earth Elements (REEs) play a vital role in crucial infrastructure technologies such as renewable energy generation and batteries. Recovering them from waste materials has recently been found to significantly reduce environmental impact and supply chain costs related to these materials. In this work, we investigate surrogate modeling techniques aimed to simplify the modeling, simulation, and optimization of the leaching processes involved in CM and REE recovery flowsheets. As there is currently a lack of systematic studies on this topic, we perform extensive computational testing to ascertain which surrogate models are easier to construct and offer high predictive accuracy. Further, our results suggest that sparse quadratic models balance predictive accuracy and computational efficiency. Training and using these surrogates for global optimization of the leaching process requires two orders of magnitude fewer measurements and is up to four orders of magnitude faster than optimizing the original simulation using equation-oriented optimization or derivative-free optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective recovery of critical materials in zero-liquid discharge supercritical water desalination

Zero-liquid discharge desalination techniques are being actively studied as alternative means to produce drinkable water and recover valuable resources without polluting the environment. Supercritical water desalination is one of such alternatives that can overcome the technical and environmental challenges in standard desalination techniques. In addition to these attractive features, this work explores the possibility of utilizing supercritical water desalination for the selective recovery of strategic (critical) materials as co-products. Here, to validate the technical and economic feasibility of the process, we prepared model brine solutions that consist of sodium, neodymium, and different anions and conducted a series of desalination experiments. The results were analyzed experimentally and theoretically and were utilized to evaluate the economic feasibility of the process. When a few tens or hundreds of parts-per-million critical materials are dissolved in the feed, the proposed method becomes more cost-effective in producing critical materials than existing technologies. In addition, it does not discharge any concentrated contaminants while producing drinkable water. These results suggest that supercritical water desalination can recover critical materials while producing freshwater in an economically feasible fashion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel Variable Refrigerant Flow (VRF) heat recovery system model: Development and validation

As one of the latest emerging HVAC technologies, the Variable Refrigerant Flow (VRF) system with heat recovery (HR) configurations has obtained extensive attention from both the academia and industry. Compared with the conventional VRF systems with heat pump (HP) configurations, VRF-HR is capable of recovering heat from cooling zones to heating zones and providing simultaneous cooling and heating operations. Moreover, this could lead to substantial energy saving potential and more flexible zonal control. In this paper, a novel model is developed to simulate the energy performance of VRF-HR systems. It adheres to a more physics-based development with the ability to simulate the refrigerant loop performance and consider the dynamics of more operational parameters, which is crucial for representing more advanced control logics. Another key feature of the model is the introduction of component-level curves for indoor units and outdoor units instead of overall performance curves for the entire system, and thus it requires much fewer user-specified performance curves as model inputs. The validation study reflects good agreements between the simulated energy use from the new VRF-HR model and the laboratory measurement data across all operational modes at sub-hourly time steps. The model has been adopted in the official release of the EnergyPlus simulation program since Version 8.6, which enables more accurate and robust assessments of VRF-HR systems to support their applications in energy retrofit of existing buildings or design of zero-net-energy buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary experimental comparison and feasibility analysis of CO2/R134a mixture in Organic Rankine Cycle for waste heat recovery from diesel engines

This paper presents results of a preliminary experimental study of the Organic Rankine Cycle (ORC) using CO2/R134a mixture based on an expansion valve. The goal of the research was to examine the feasibility and effectiveness of using CO 2 mixtures to improve system performance and expand the range of condensation temperature for ORC system. The mixture of CO 2 /R134a (0.6/0.4) on a mass basis was selected for comparison with pure CO 2 in both the preheating ORC (P-ORC) and the preheating regenerative ORC (PR-ORC). Then, the feasibility and application potential of CO 2 /R134a (0.6/0.4) mixture for waste heat recovery from engines was tested under ambient cooling conditions. Preliminary experimental results using an expansion valve indicate that CO 2 /R134a (0.6/0.4) mixture exhibits better system performance than pure CO 2 . For PR-ORC using CO 2 /R134a (0.6/0.4) mixture, assuming a turbine isentropic efficiency of 0.7, the net power output estimation, thermal efficiency and exergy efficiency reached up to 5.30 kW, 10.14% and 24.34%, respectively. For the fitting value at an expansion inlet pressure of 10 MPa, the net power output estimation, thermal efficiency and exergy efficiency using CO2/R134a (0.6/0.4) mixture achieved increases of 23.3%, 16.4% and 23.7%, respectively, versus results using pure CO2 as the working fluid. Finally, experiments showed that the ORC system using CO2/R134a (0.6/0.4) mixture is capable of operating stably under ambient cooling conditions (25.2-31.5 °C), demonstrating that CO 2 /R134a mixture can expand the range of condensation temperature and alleviate the low-temperature condensation issue encountered with CO 2 . Under the ambient cooling source, it is expected that ORC using CO 2 /R134a (0.6/0.4) mixture will improve the thermal efficiency of a diesel engine by 1.9%.

42 ENGINEERING↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying CO 2 storage efficiency factors in hydrocarbon reservoirs. A detailed look at CO 2 Enhanced Oil Recovery

Carbon dioxide (CO 2 ) enhanced oil recovery (EOR) will likely be the primary means of geologic CO 2 storage during the early stages of commercial-scale carbon capture and storage (CCS) because of the inherent economic incentives as well as the abundant experience and demonstrated success in the United States, where CO 2 EOR has been employed since 1974. The work presented here estimates CO 2 storage efficiency factors in CO 2 EOR operations using a unique industry database of CO 2 EOR sites and 12 different reservoir simulation models. The simulation models encompass fluvial clastic and shallow shelf carbonate depositional environments for reservoir depths of 1219 and 2438 m (4000 and 8000 feet) and 7.6-, 20-, and 64-m (25-, 66-, and 209-foot)-thick pay zones. A novel statistical modeling technique incorporating the Michaelis–Menten function is used to generate empirical percentile estimates of CO 2 storage efficiency factors. West Texas San Andres dolomite water alternating gas (WAG) CO 2 flood performance data were used to derive P10, P50, and P90 CO 2 storage efficiency factors of 0.76, 1.28, and 1.74 Mscf/STB (stock tank barrel) of original oil in place. Median CO 2 storage efficiency factors from continuous CO 2 injection following conventional waterflood varied from 15% to 61% and 8% to 40% for fluvial clastic and shallow shelf carbonate simulation models, respectively, while those from WAG injection varied from 14% to 42% and 8% to 31%, respectively. Variation in the CO 2 storage efficiency factors was largely attributable to reservoir depth (a surrogate for reservoir pressure and temperature) and lithology (clastic versus carbonate). The results of this work provide practical information that can be used to quantify CO 2 storage resource estimates in oil reservoirs during CO 2 EOR operations (as opposed to storage following depletion) and the uncertainty associated with those estimates.

54 ENVIRONMENTAL SCIENCES↗

Cost curve of large-scale deployment of CO2-enhanced water recovery technology in modern coal chemical industries in China

China has emerged as a world leader in the coal chemical industry, which requires large amount of water and results in considerable CO2 emissions. This situation has led to the challenge of the CO2-Water nexus for China and particularly for the sustainable development of its coal chemical industry. CO2-enhanced water recovery (CO2-EWR) technology can provide large-scale CO2 mitigation and additional water supply in an integrated manner, especially in arid areas. Meanwhile, CO2 streams from industrial separation processes in the coal chemical industries are amenable to separation and can dramatically simplify or even dispense with the capture process. This study presents the first systematic assessment of a cost curve for onshore CO2-EWR potential using CO2 streams from industrial separation processes by an evaluation framework encompassing CO2 emission inventory, site suitability evaluation, and source–sink matching with techno-economic models. Preliminary results focused on the full capacity of several coal chemical processes as of 2015 suggest that CO2-EWR technology can mitigate 269 million tons of CO2 from industrial separation processes at relatively low cost ranging from 12 to 30 USD/t CO2 in China. Furthermore, 404 million tons of underground water could be produced for further desalination and utilization. When additional capacity under development could become fully operational, the emissions of 878 million tons of CO2 could be mitigated and provide 1318 million tons of vital water resources. Therefore, CO2-EWR technology can be essential to clean and sustainable development of the coal chemical industry and may provide low-cost opportunities to accelerate the deployment of large-scale CCUS projects in China.

CO2-enhanced water recovery, Modern coal chemical ↗

Electrochemical sulfate production from sulfide-containing wastewaters and integration with electrochemical nitrogen recovery

Electrochemical methods can help manage sulfide in wastewater, which poses environmental and health concerns due to its toxicity, malodor, and corrosiveness. In addition, sulfur could be recovered as fertilizer and commodity chemicals from sulfide-containing wastewaters. Wastewater characteristics vary widely among wastewaters; however, it remains unclear how these characteristics affect electrochemical sulfate production. Here, in this study, we evaluated how four characteristics of influent wastewaters (electrolyte pH, composition, sulfide concentration, and buffer strength) affect sulfide removal (sulfide removal rate, sulfide removal efficiency) and sulfate production metrics (sulfate production rate, sulfate production selectivity). We identified that electrolyte pH (3 × difference, i.e., 25.1 to 84.9 μM h –1 in average removal rate within the studied pH range) and sulfide concentration (16 × difference, i.e., 82.1 to 1347.2 μM h –1 in average removal rate) were the most influential factors for electrochemical sulfide removal. Sulfate production was most sensitive to buffer strength (6 × difference, i.e., 4.4 to 27.4 μM h –1 in average production rate) and insensitive to electrolyte composition. Together, these results provide recommendations for the design of wastewater treatment trains and the feasibility of applying electrochemical methods to varying sulfide-containing wastewaters. In addition, we investigated a simultaneous multi-nutrient (sulfur and nitrogen) process that leverages electrochemical stripping to further enhance the versatility and compatibility of electrochemical nutrient recovery.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A manufacturing process design for producing a membrane-based energy recovery ventilator with high aspect ratio support ribs

Heating, ventilation, and air conditioning systems represent nearly half of building energy usage in the United States. Recent building regulations requiring increased air turnover within buildings will result in even greater air conditioning usage. To alleviate these concerns, membrane-based heat-and-moisture exchangers known as energy recovery ventilators have been developed to reduce the energy expenditure of air conditioning systems by pre-conditioning incoming air through sensible and latent heat transfer with building air exhaust. Here in this work, we propose and validate a manufacturing process design for channel lamination based on surface mount adhesives capable of meeting the process requirements of a membrane-based ventilator. In particular, the device requires rib supports with height-to-width aspect ratios greater than one. The proposed manufacturing process design is capable of meeting this process requirement by stretching the adhesive after initial adhesive tacking. A manufacturing process flow diagram, a machine tool specification and a cost model are proposed for meeting process requirements. A set of design constraints are developed detailing the adhesive requirements necessary for meeting requirements. The cost model is validated by building a sub-scale mesochannel array demonstrating the ability to meet process requirements. Results show that additional work is needed to validate the curing step but that the process is capable of producing a mesochannel array with an acceptable level of variation.

42 ENGINEERING↗

Succinic acid-based leaching system: A sustainable process for recovery of valuable metals from spent Li-ion batteries

A hydrometallurgical method involving natural organic acid leaching has been developed for recovery of lithium and cobalt from the cathode active materials in spent lithium-ion batteries. Succinic acid is employed as leaching agent and H2O2 as reductant. The cobalt and lithium contents from the succinic acid-based treatment of spent batteries are determined by inductively coupled plasma-optical emission spectroscopy to calculate the leaching efficiency. The spent LiCoO2 samples after calcination and the residues after leaching are characterized by X-ray diffraction and scanning electron microscopy. The results show that nearly 100% of cobalt and more than 96% of lithium are leached under optimal conditions: succinic acid concentration of 1.5 mol L-1, H2O2 content of 4 vol.%, solid-to-liquid ratio of 15 g L-1, temperature of 70 °C, and reaction time of 40 min. Results are also given for fitting of the experimental data to acid leaching kinetic models.

25 ENERGY STORAGE↗

Energy transfer for storage or recovery in capacitive deionization using a DC-DC converter

Energy recovery from capacitive deionization (CDI) has the potential to increase overall desalination efficiency. We here define the storage (one-way) and utilization (round-trip) efficiencies between a CDI cell and an energy storage device using a generic direct current/direct current (DC/DC) converter circuit. Presented is a closed-form analytical model for the case of a supercapacitor (SC) as the energy storage device and a buck-boost converter as the DC/DC converter. The model is benchmarked with a numerical model, showing good agreement. Also presented is a comparison among energy transfer methods wherein desalination productivity is fixed. For constant current operation, this condition requires higher currents to compensate for the inactive time introduced by the converter. For fixed productivity, the mean current of the converter circuit approaches the constant current value for higher initial voltages and lower capacitances in the supercapacitor. Finally, we show the effect of relevant parameters of the SC in the storage and utilization efficiency. The model predicts storage and utilization efficiencies of at least 90% for an initial voltage of 1 V or higher and reasonable CDI and SC parameters. Finally, we provide engineering operational parameters to maximize the efficiency of energy transfer and guidance in the selection of electronic components.

25 ENERGY STORAGE↗

Surprising olefin/paraffin separation performance recovery of highly aged carbon molecular sieve hollow fiber membranes by a super-hyperaging treatment

Carbon molecular sieve (CMS) hollow fibers derived from 6FDA 1 :BPDA 1 /DAM 2 , a well-studied polyimide precursor with attractive propylene/propane separation performance, were purposely treated to simulate long time aging under storage conditions. A simple, efficient post-aging thermal-treatment regeneration termed “super-hyperaging” is shown here to recover C 3 H 6 permeance with satisfactory C 3 H 6 /C 3 H 8 selectivity. A super-hyperaging temperature around 280 °C in air is shown to provide an optimum tradeoff in permeance and selectivity for highly aged samples. The regenerated CMS membrane displays performance well beyond the polymer permeance-selectivity tradeoff upper bound, and a hypothetical mechanism for the super-hyperaging recovery of aged CMS fibers is discussed in this work.

Recovery↗

Finely tuning the microporosity in phosphoric acid doped triptycene-containing polybenzimidazole membranes for highly permselective helium and hydrogen recovery

High-performance polymer membranes with well-defined microporosity and size-sieving ability are especially attractive for helium and hydrogen recovery. Here, in this study, we report novel macromolecular engineering of polybenzimidazole (PBI) membranes that integrate hierarchical triptycene units for high permeability and polyprotic acid doping for size sieving via controllable manipulation of microporous architecture. The triptycene moieties disrupt chain packing and introduce additional configurational free volume, leading to significantly boosted He and H 2 permeabilities compared to previously reported PBI membranes. The acid doping resulted in crosslinked PBI membranes via hydrogen bonding and proton transfer with dramatically enhanced gas selectivities. Via adjusting the H 3 PO 4 -doping level, triptycene-based polybenzimidazole (TPBI) composite membranes (TPBI-(H 3 PO 4 ) x ) exhibit the highest gas selectivities for He enrichment (i.e., α(He/CH 4 ) = 7052 ± 156) and H 2 purification (i.e., α(H 2 /CH 4 ) = 5128 ± 110) among existing polymeric gas separation membranes. Additionally, under mixed-gas conditions at 150 °C, the TPBI-(H 3 PO 4 ) 0.98 membrane displays a H 2 permeability of 46.7 Barrer and a H 2 /CO 2 selectivity of 16, far beyond the Robeson's 2008 upper bound for H 2 /CO 2 separation. The facile and diverse tunability and excellent gas separation performance make TPBI-(H 3 PO 4 ) x membranes highly attractive for helium and hydrogen separation.

42 ENGINEERING↗