Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A radiological assessment of space nuclear power operations near Space Station Freedom

In order to accomplish NASA's more ambitious exploration goals, nuclear reactors may be used in the vicinity of Space Station Freedom (SSF) either as power sources for coorbiting platforms or as part of the propulsion system for departing and returning personnel or cargo vehicles. This study identifies ranges of operational parameters, such as parking distances and reactor cooldown times, which would reasonably guarantee that doses to the SSF crew from all radiation sources would be below guidelines recently recommended by the National Council of Radiation Protection and Measurements. The specific scenarios considered include: (1) the launch and return of a nuclear electric propulsion vehicle, (2) the launch and return of a nuclear thermal rocket vehicle, (3) the operation of an SP-100 class reactor on a coorbiting platform, (4) the activation of materials near operating reactors, (5) the storage and handling of radioisotope thermal generator units, and (6) the storage and handling of fresh and previously operated reactors. Portable reactor shield concepts were examined for relaxing the operational constraints imposed by unshielded (for human proximity operations) reactors and that might also be used to provide additional SSF crew protection from natural background radiation.

Stevenson, Steve↗

The electromagnetic radiation from simple sources in the presence of a homogeneous dielectric sphere

In this research, the effect of a homogeneous dielectric sphere on the electromagnetic radiation from simple sources is treated as a boundary value problem, and the solution is obtained by the technique of dyadic Green's functions. Exact representations of the electric fields in the various regions due to a source located inside, outside, or on the surface of a dielectric sphere are formulated. Particular attention is given to the effect of sphere size, source location, dielectric constant, and dielectric loss on the radiation patterns and directivity of small spheres (less than 5 wavelengths in diameter) using the Huygens' source excitation. The computed results are found to closely agree with those measured for waveguide-excited plexiglas spheres. Radiation patterns for an extended Huygens' source and for curved electric dipoles located on the sphere's surface are also presented. The resonance phenomenon associated with the dielectric sphere is studied in terms of the modal representation of the radiated fields. It is found that when the sphere is excited at certain frequencies, much of the energy is radiated into the sidelobes. The addition of a moderate amount of dielectric loss, however, quickly attenuates this resonance effect. A computer program which may be used to calculate the directivity and radiation pattern of a Huygens' source located inside or on the surface of a lossy dielectric sphere is listed.

Mason, V. B.↗

When x-rays alter the course of your experiments

The continuing increase in the brilliance of synchrotron radiation beamlines allows for many new and exciting experiments that were impossible before the present generation of synchrotron radiation sources came on line. However, the exposure to such intense beams also tests the limits of what samples can endure. Whilst the effects of radiation induced damage in a static experiment often can easily be recognized by changes in the diffraction or spectroscopy curves, the influence of radiation on chemical or physical processes, where one expects curves to change, is less often recognized and can be misinterpreted as a 'real' result instead of as a 'radiation influenced result'. This is especially a concern in time-resolved materials science experiments using techniques as powder diffraction, small angle scattering and x-ray absorption spectroscopy. In this work, the effects of radiation (5–50 keV) on some time-resolved processes in different types of materials and in different physical states are discussed. We show that such effects are not limited to soft matter and biology but rather can be found across the whole spectrum of materials research, over a large range of radiation doses and is not limited to very high brilliance beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The effects of chromospheric radiation on the circumstellar chemistry of evolved stars

Astrophysical situations are discussed in which radiation sources other than interstellar are important, and the atomic abundances of the Alpha Ori circumstellar envelope (CSE) are related to the chromospheric and interstellar radiation fields, and to the temperature distribution. The most common Alpha Ori CSE species are neutral atoms and first ions, and the electron fraction is high throughout the entire CSE. A peak in the neutral abundances in the outer CSE appears close to where the chromospheric and interstellar radiation fields are equal. The present theory predicts that the slope of the K I density should change from about -1.5 to -3.5 in the outer envelope, with the mass loss rate implied by this K I density being of the order of 4 x 10 to the -6th solar masses/yr.

Glassgold, A. E.↗

Z mode radiation in Jupiter's magnetosphere - The source of Jovian continuum radiation

Observations of Z-mode waves in Jupiter's magnetosphere are analyzed. The assumption that the frequency of the intensity minimum, which isolates the signal, corresponds to the electron plasma frequency provides a consistent interpretation of all spectral features in terms of plasma resonances and cutoffs. It is shown that the continuum radiation is composed of both left-hand and right-hand polarized waves with distinct cutoffs observed at the plasma frequency and right-hand cutoff frequency, respectively. It is found that the Z-mode peak frequency lies close to the left-hand cutoff frequency, suggesting that the observed characteristics of the emission are the result of wave reflection at the cutoff layer. Another distinct emission occurring near the upper hybrid resonance frequency is detected simultaneously with the Z mode. The entire set of observations gives strong support to the linear mode theory of the conversion of upper hybrid waves to continuum radiation mediated by the Z mode via the Budden radio window mechanism.

Barbosa, D. D.↗

Weak soft X-ray excesses need not result from the high-frequency tail of the optical/ultraviolet bump in active galactic nuclei

The broad-band ROSAT/EXOSAT X-ray spectra of six Seyfert 1 galaxies are fitted by a model consisting of a direct power law and a component due to reflection/reprocessing from a partially ionized, optically thick medium. The reflected spectrum contains emission features from various elements in the soft X-ray range. In all objects but one (Mrk 335), the fit is satisfactory, and no additional soft X-ray excess is required by the data. This means that in most sources there is no need for the thermal 'big blue bumps' to extend into soft X-rays, and the soft X-ray excesses reported previously can be explained by reflection/reprocessing. Satisfactory fits are obtained for a medium ionized by a source radiating at less than or approximately 15% of the Eddington rate. The fits require that the reflection is enhanced relative to an isotropically emitting source above a flat disk. The necessary high effectiveness of reflection in the soft X-ray band requires strong soft thermal flux dominating over hard X-rays.

Czerny, Bozena↗

Precise Sound Velocity Measurements on Solids and Liquids at High Pressure and High Temperature with Direct Length Measurement

Sound velocity measurements at pressure and/or temperature provide important information in the material's structural behavior and physical properties under extreme conditions. With the application of synchrotron X-radiation sources, new developments have emerged to facilitate the study properties and structures of crystalline and amorphous materials. In the last decade, we have developed a unique technique for measuring sound velocity in a cubic type multianvil apparatus installed at X-17B2, National Synchrotron Light Source (NSLS) of Brookhaven National Lab, which allows us to conduct precise velocity measurements on crystalline and noncrystalline materials at various pressure and temperature conditions by conducting simultaneous X-radiation and ultrasonic interferometry measurements. In this paper, sound velocities at high temperatures for some ceramics and metals are measured to study the behavior and property change of these materials undergoing compression/expansion as well as phase transition and structural instabilities. This technique opens new opportunities for the study of materials that are of interest to many disciplines, such as earth science, materials science, and condensed matter physics.

99 GENERAL AND MISCELLANEOUS↗

Laser-Produced Coherent X-ray Sources. Final report

This is the final report for the DOE-AMO DE-FG02-05ER15663 grant. Using a high-peak-power laser system at the Extreme Light Laboratory of the University of Nebraska-Lincoln, we develop novel femtosecond radiation sources and use them to investigate ultrafast photo-induced processes. Pulses of high energy electrons and x-rays are generated when an optical pulse is focused to ultra-high intensity. The radiation is used to probe the evolution of matter under highly non-equilibrium conditions with atomic-scale temporal and spatial resolution. Moreover, the facility is small enough to fit in a university laboratory and is operated by graduate students and postdocs.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Demonstration of Comprehensive Ex-Vessel Fluence Capability

Several recent developments in the Consortium for Advanced Simulation of Light Water Reactors’ (CASL) Virtual Environment for Reactor Applications (VERA) were tested to highlight its capability to perform ex-vessel fluence and reaction rate calculations. VERA offers unique capabilities for integrating the deterministic neutronics code, MPACT, with Shift, a Monte Carlo code, to perform high-fidelity in-core and ex-core radiation transport. Applications such as pressure vessel fluence, ex-core detector response, and coupon irradiation analyses take advantage of this coupling. For these applications, MPACT performs the in-core radiation transport with temperature feedback and isotopic depletion through the direct coupling with the CTF subchannel thermal-hydraulics code. Then, MPACT provides the fission source to Shift for a follow-on fixed source radiation transport calculation that tallies all the ex-core responses of interest for each time-dependent statepoint. The variance reduction method, CADIS, which is implemented in Shift, allows for efficient performance of ex-core transport for calculation of ex-core quantities of interest. This milestone report identifies limitations to the current methodology in place and showcases VERA’s current capability to model ex-core quantities of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improved nucleonic coal-thickness monitor

Design for coal-thickness-sensing instrument features independent hydropneumatic suspension of radiation source and detector. Monitor uses source and detector which are independently mounted, to follow contour of coal surface more closely and to eliminate errors caused by variations in airgap along radiation path. Device may help to bring fully-automated coal mining closer to reality.

Crouch, C. E.↗

Signal Restoration of Non-stationary Acoustic Signals in the Time Domain

Signal restoration is a method of transforming a nonstationary signal acquired by a ground based microphone to an equivalent stationary signal. The benefit of the signal restoration is a simplification of the flight test requirements because it could dispense with the need to acquire acoustic data with another aircraft flying in concert with the rotorcraft. The data quality is also generally improved because the contamination of the signal by the propeller and wind noise is not present. The restoration methodology can also be combined with other data acquisition methods, such as a multiple linear microphone array for further improvement of the test results. The methodology and software are presented for performing the signal restoration in the time domain. The method has no restrictions on flight path geometry or flight regimes. Only requirement is that the aircraft spatial position be known relative to the microphone location and synchronized with the acoustic data. The restoration process assumes that the moving source radiates a stationary signal, which is then transformed into a nonstationary signal by various modulation processes. The restoration contains only the modulation due to the source motion.

Babkin, Alexander S.↗

Discrete ordinates solutions of nongray radiative transfer with diffusely reflecting walls

Nongray gas radiation in a plane parallel slab bounded by gray, diffusely reflecting walls is studied using the discrete ordinates method. The spectral equation of transfer is averaged over a narrow wavenumber interval preserving the spectral correlation effect. The governing equations are derived by considering the history of multiple reflections between two reflecting wails. A closure approximation is applied so that only a finite number of reflections have to be explicitly included. The closure solutions express the physics of the problem to a very high degree and show relatively little error. Numerical solutions are obtained by applying a statistical narrow-band model for gas properties and a discrete ordinates code. The net radiative wail heat fluxes and the radiative source distributions are obtained for different temperature profiles. A zeroth-degree formulation, where no wall reflection is handled explicitly, is sufficient to predict the radiative transfer accurately for most cases considered, when compared with increasingly accurate solutions based on explicitly tracing a larger number of wail reflections without any closure approximation applied.

Menart, J. A.↗

Ultraviolet technology.

UV technology, discussing radiation sources, photodetectors, filters, polarizers, reflective coatings, etc

PHOTOGRAPHIC RECORDING INSTRUMENT↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

61 RADIATION PROTECTION AND DOSIMETRY↗

Site Environmental Report for 2018

Lawrence Berkeley National Laboratory (LBNL, Berkeley Lab) is a multi-program scientific facility operated by the University of California (UC) for the U.S. Department of Energy (DOE). Berkeley Lab’s research is focused on the physical, biological, environmental, and computational sciences, with the objective of delivering scientific knowledge and discoveries pertinent to DOE’s mission. This annual report describes environmental protection activities and potential impacts resulting from LBNL operations conducted in 2018. The format and content of this report satisfy the requirements of both DOE Order 231.1B, Administrative Change 1 (Environment, Safety, and Health Reporting) and the operating contract between UC and DOE (DOE Contract No. DE-AC02-05CH11231, also known as Contract 31). LBNL activities are planned and conducted with full regard to protecting employees, the public, and the environment, as well as complying with all applicable environmental, safety, and health laws and regulations. As presented in Chapter 2, Berkeley Lab implements an Environmental Management System (EMS) to oversee environmental compliance activities and continually improve overall environmental performance while maintaining operational capability and sustaining its overall mission. The effectiveness of the EMS and environmental programs is reviewed annually as part of the performance evaluation process of Contract 31. For fiscal year (FY) 2018, which began October 1, 2017, and ended September 30, 2018, the EMS was given a performance rating of B plus for its management of environmental activities (on a scale from A plus as the highest grade, to F as the lowest). The measurement and rating system was developed jointly by Berkeley Lab, UC, and DOE. The FY 2018 rating was based on how Berkeley Lab met the objective in DOE’s FY 2018 Performance Evaluation and Measurement Plan (Appendix B in Contract 31, Section J) of providing an efficient and effective EMS. Six significant accomplishments, which ranged from effective teaming on projects and with regulatory agencies to improved program assessment approaches, were factors in the rating. The EMS was also graded through the federal Office of Management and Budget’s annual EMS performance metrics, in which a reporting scorecard rates elements of the International Organization for Standardization (ISO) 14001 standard and the degree of integration between the EMS and Berkeley Lab’s sustainable practices. Overall scores fall into one of three categories: green (highest), yellow (middle), or red (lowest). For FY 2018, Berkeley Lab received a score of green. A week-long formal conformity audit of the EMS was conducted at the end of July by a qualified external party, as is required every three years. The audit team found that Berkeley Lab’s EMS continues to conform to the ISO standard with no major nonconformance. An overview of environmental protection and restoration programs is provided in Chapter 3, including information about compliance activities, operating permits, and regulatory agency inspections and audits that occurred during 2018. Twenty-one minor violations and two Class II violations were issued during agency inspections of programs governing aboveground and underground storage tanks, hazardous waste treatment units, hazardous waste storage areas, hazardous materials management, and wastewater, stormwater, and air emission sources. This report also includes information on environmental monitoring performed in 2018 (Chapter 4). The results of these monitoring activities confirmed that groundwater cleanup actions have been effective in reducing concentrations of volatile organic compounds (VOCs) in the groundwater, although concentrations appear to be reaching asymptotic levels in some areas. Site groundwater plumes are stable or are attenuating, and VOCs are not migrating off site. All emissions and discharges from LBNL operations were within environmental compliance release limits except oxides of nitrogen and carbon monoxide from boilers (under 5 million BTUs) from Buildings 2, 66, and 88. The radiological dose assessments (Chapter 5) performed in 2018 concluded that the maximum potential dose to a hypothetical resident from Berkeley Lab’s airborne radionuclide releases was approximately 0.04% of the DOE and U.S. Environmental Protection Agency annual limit of 10 millirem per year (mrem/yr); the potential dose from all radiation sources at Berkeley Lab was approximately 0.15% of the average natural background radiation dose of 310 mrem/yr in the United States, and about 0.5% of the DOE annual limit of 100 mrem/yr from all sources.

54 ENVIRONMENTAL SCIENCES↗

Limitations on thermal and nonthermal models for the radiation from extragalactic sources.

Both thermal and nonthermal models for the radiation from QSOs and Seyfert galaxies are discussed in terms of the size limitations imposed by the models. It is concluded that if daily fluctuations in the luminosity of Seyfert galaxies are confirmed and do represent a maximum size for the sources, then neither dust models nor ordinary synchrotron models can explain the radiation. Colgate's proposal involving the production of infrared radiation by a nonthermal plasma is considered, and a more detailed theory is derived which indicates that the process cannot produce infrared radiation.

Jones, T. W.↗