Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Rotational Doppler effect in x-ray photoionization

The energy of the photoelectron experiences a red or blue Doppler shift when the molecule recedes from the detector or approaches him. This results in a broadening of the photoelectron line due to the translational thermal motion. However, the molecules also have rotational degrees of freedom and we show that the translational Doppler effect has its rotational counterpart. This rotational Doppler effect leads to an additional broadening of the spectral line of the same magnitude as the Doppler broadening caused by translational thermal motion. The rotational Doppler broadening as well as the rotational recoil broadening is sensitive to the molecular orbital from which the photoelectron is ejected. This broadening should be taken into account in analysis of x-ray photoemission spectra of super-high resolution and it can be directly observed using x-ray pump-probe spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Octahedral rotations in Ruddlesden-Popper layered oxides under pressure from first principles

The combination of reduced dimensionality and tunable structural distortions in layered perovskite oxides makes these materials ideal platforms for designing novel properties and functionalities. One example is hybrid improper ferroelectricity in n = 2 Ruddlesden-Popper oxides, where the combination of a layered crystal structure and rotations of the metal-oxide octahedra break symmetry and induce a polarization. Precisely controlling the octahedral rotation distortions, for example by the application of hydrostatic pressure, provides a pathway to tune and optimize the properties of these materials. Here we combine group theoretic methods, density functional theory calculations, and Landau theory analysis to investigate how octahedral rotations respond to pressure in the hybrid improper ferroelectrics Sr 3 Zr 2 O 7 , Ca 3 Ti 2 O 7 , and Sr 3 Sn 2 O 7 . We find that factors that are known to control the pressure response of ABO 3 perovskites—the formal charge of the A- and B-site cations, tolerance factor, and B-site chemistry—also impact the pressure response of these layered perovskites. We also show that coupling between the octahedral rotation and strain order parameters plays a key role in determining the overall pressure response. Despite some similarities, we find that these layered perovskites display a distinct pressure response compared to their ABO 3 perovskite analogs. By identifying trends and underlying mechanisms that control octahedral rotations in Ruddlesden-Popper oxides under pressure, this work lays the foundation for tailoring the structure and properties of these materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Slowly rotating gravastars

We solve Einstein’s equations for slowly rotating gravitational condensate stars (gravastars) up to second order in the rotation by expanding about the spherically symmetric gravastar with de Sitter interior and Schwarzschild exterior matched at their common horizon. Requiring that the perturbations are finite on the null surface reduces the exterior geometry to that of a Kerr black hole, implying that a slowly rotating gravastar cannot be distinguished from a Kerr black hole by any measurement or observation restricted to the macroscopic spacetime exterior to the horizon. Here we determine the interior solution, the surface stress tensor, and the Komar mass and angular momentum localized on the slowly rotating horizon surface. With the interior equation of state fixed at p = –ρ, finite junction conditions on the null horizon surface necessarily lead to an interior solution with a singular core, where the perturbative expansion breaks down. Comparison to other models and implications for more rapidly rotating gravastars are briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Modified dispersion relations and the response of the rotating Unruh-DeWitt detector

We study the response of a rotating monopole detector that is coupled to a massless scalar field which is described by a nonlinear dispersion relation in flat spacetime. Since it does not seem to be possible to evaluate the response of the rotating detector analytically, we resort to numerical computations. Interestingly, unlike the case of the uniformly accelerated detector that has been considered recently, we find that defining the transition probability rate of the rotating detector poses no difficulties. Further, we show that the response of the rotating detector can be computed exactly (albeit, numerically) even when it is coupled to a field that is governed by a nonlinear dispersion relation. We also discuss the response of the rotating detector in the presence of a cylindrical boundary on which the scalar field is constrained to vanish. While superluminal dispersion relations hardly affect the standard results, we find that subluminal dispersion relations can lead to relatively large modifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reversal in the Size Dependence of Grain Rotation

The conventional belief, based on the Read-Shockley model for the grain rotation mechanism, has been that smaller grains rotate more under stress due to the motion of grain boundary dislocations. However, in our high-pressure synchrotron Laue x-ray microdiffraction experiments, 70 nm nickel particles are found to rotate more than any other grain size. We infer that the reversal in the size dependence of the grain rotation arises from the crossover between the grain boundary dislocation-mediated and grain interior dislocation-mediated deformation mechanisms. The dislocation activities in the grain interiors are evidenced by the deformation texture of nickel nanocrystals. This new finding reshapes our view on the mechanism of grain rotation and helps us to better understand the plastic deformation of nanomaterials, particularly of the competing effects of grain boundary and grain interior dislocations.

36 MATERIALS SCIENCE↗

Image Rotation in Plasmas

Because of the speed of light compared to material motion, the dragging of light is difficult to observe under laboratory conditions. Furthermore we report on the first observation of image rotation, i. e. a dragging by the medium of the wave’s transverse structure, of Alfv´en waves in plasmas. Exploiting the naturally slow group velocity of these waves, significant wave rotation is achieved for modest angular frequency. Control over the rotation of the wave’s structure is demonstrated through the plasma rotation imposed by biased electrodes. Remarkably, experimental results are well reproduced by light dragging theory derived for isotropic media, even if magnetized plasmas are anisotropic. In addition to offering new insights into the fundamental issue of angular momentum coupling between waves and media, these findings also open possibilities for new remote rotation sensing tools.

Alfvén waves↗

In situ study of rotating lattice single–crystal formation in Sb 2 S 3 glass by Laue μXRD

Single–crystal architectures in glass, formed by a solid–solid transformation via laser heating, are novel solids with a rotating lattice. To understand the process of lattice formation that proceeds via crystal growth, we have observed in situ Sb 2 S 3 crystal formation under X–ray irradiation with simultaneous Laue micro X–ray diffraction (μXRD) pattern collection. By translating the sample with respect to the beam, we form rotating lattice single (RLS) crystal lines with a consistently linear relationship between the rotation angle and distance from nucleation site. The lines begin with a seed crystal, followed by a transition region comprising of sub–grain or very similarly oriented grains, followed by the presence of a rotating lattice single crystal of unrestricted length. Here, the results demonstrate that the primary cause of lattice rotation within RLS crystals is the densification accompanying the glass → crystal transformation, rather than stresses produced from the difference in thermal expansion coefficient of the two phases or paraelectric → ferroelectric transition during cooling to ambient temperature.

36 MATERIALS SCIENCE↗

Lattice Rotation Patterns and Strain Gradient Effects in Face-Centered-Cubic Single Crystals Under Spherical Indentation

Strain gradient effects are commonly modeled as the origin of the size dependence of material strength, such as the dependence of indentation hardness on contact depth and spherical indenter radius. However, studies on the microstructural comparisons of experiments and theories are limited. First, we have extended a strain gradient Mises-plasticity model to its crystal plasticity version and implemented a finite element method to simulate the load-displacement response and the lattice rotation field of Cu single crystals under spherical indentation. The strain gradient simulations demonstrate that the forming of distinct sectors of positive and negative angles in the lattice rotation field is governed primarily by the slip geometry and crystallographic orientations, depending only weakly on strain gradient effects, although hardness depends strongly on strain gradients. Second, the lattice rotation simulations are compared quantitatively with micron resolution, three-dimensional X-ray microscopy (3DXM) measurements of the lattice rotation fields under 100mN force, 100 mu m radius spherical indentations in < 111 >, < 110 >, and < 001 > oriented Cu single crystals. Third, noting the limitation of continuum strain gradient crystal plasticity models, two-dimensional discrete dislocation simulation results suggest that the hardness in the nanocontact regime is governed synergistically by a combination of strain gradients and source-limited plasticity. However, the lattice rotation field in the discrete dislocation simulations is found to be insensitive to these two factors but to depend critically on dislocation obstacle densities and strengths.

Gao, Y. F.↗

Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about {+-}2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude ({+-}2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of {+-}7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D{sub 50} of organs at risk, the D{sub 95} for planning target volumes (PTVs), and the local dose difference were used to evaluate the changes in the modified treatment plans. Dosimetric effects from rotational variation were found to be low (less than 1%) for a typical variation of {+-}2%. Even using a variation of {+-}7%, DVH values and dose distributions were altered by less than 2% for all scenarios. The dosimetric effects of target degradation were found to be slightly more significant. For a model using data taken just before target failure, dosimetric differences of 2%-4% were observed in the recalculated plans when compared to the original plans. The largest effects (up to 4.5%) were observed for PTVs that were located at deeper depths as seen in the prostate plan. Overall, the recalculated plans show that the dosimetric effects of rotational variation and target degradation are on the order of 1%-4% for helical tomotherapy on the HiART system and do not pose a risk for significant deviations from the original treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

A conceptual design of rotating board technique for delivering total skin electron therapy

Purpose: This study presents a novel technique in which a uniform radiation dose to the whole body, soles, and scalp vertex can be achieved in one electron beam treatment fraction. Methods: The patient was treated at a machine with a home-made rotating board. The patients were treated in two groups in the prone and supine positions by leaning onto an inner rotational board in the prone and supine positions. Each group can further be separated into two subgroups using tilting and rotational positions for treatment. Results: One of the beams was directed 15.5 deg. upward and 15.5 deg. downward from the horizontal axis to provide a field size of as large as 200 cm in height and 140 cm in width. An incline angle of 31.5 deg. anteriorly (forward) or posteriorly (backward) of the outer frame at an angle rotated 60 deg. clockwise or counterclockwise to the inner frame was found to be most appropriate. The output for the rotating board total skin electron therapy (RB-TSET) was 0.046 cGy/MU at ISD of 350 cm. The beam characteristics of the RB-TSET depth dose curves were R{sub 50}=2.48 cm, d{sub max}=0.7 cm, E{sub 0}=5.78 MeV, and R{sub p}=3.4 cm. Conclusions: The RB-TSET technique presented in this study is able to deliver a uniform radiation dose to the patient's skin surface, the scalp vertex, and soles of the feet all at one time, eliminating the trouble of having to further irradiate these two regions separately when using the Stanford six field technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-E-05: Initial Experience On Physics Rotation of Radiological Residents

Purpose: The new ABR core exam integrates physics into clinical teaching, with an emphasis on understanding image quality, image artifacts, radiation dose and patient safety for each modality and/or sub-specialty. Accordingly, physics training of radiological residents faces a challenge. A traditional teaching of physics through didactic lectures may not fully fulfill this goal. It is also difficult to incorporate physics teaching in clinical practice due to time constraints. A dedicated physics rotation may be a solution. This study is to evaluate a full week physics workshop developed for the first year radiological residents. Methods: The physics rotation took a full week. It included three major parts, introduction lectures, hand-on experiences and observation of technologist operation. An introduction of basic concepts was given to each modality at the beginning. Hand-on experiments were emphasized and took most of time. During hand-on experiments, residents performed radiation measurements, studied the relationship between patient dose and practice (i.e., fluoroscopy), investigated influence of acquisition parameters (i.g., kV, mAs) on image quality, and evaluated image quality using phantoms A physics test before and after the workshop was also given but not for comparison purpose. Results: The evaluation shows that the physics rotation during the first week of residency in radiology is preferred by all residents. The length of a full week of physics workshop is appropriate. All residents think that the intensive workshop can significantly benefit their coming clinical rotations. Residents become more comfortable regarding the use of radiation and counseling relevant questions such as a pregnant patient risk from a CE PE examination. Conclusion: A dedicated physics rotation, assisting with didactic lectures, may fulfill the requirements of physics of the new ABR core exam. It helps radiologists deeply understand the physics concepts and more efficiently use the medical physics in practice.

60 APPLIED LIFE SCIENCES↗

SU-E-T-39: Analyses of Plan Quality Using Different Gantry Rotation Time On Volumetric Modulated Arc Therapy in Rectal Carcinoma

Purpose: To compare plan quality of volumetric modulated arc radiotherapy (VMAT) using different gantry rotation times. Methods: In ten rectal carcinoma patients, plans with different gantry rotation times were designed by Oncentra4.3 planning system, each of them was optimized by experienced planners using almost similar parameters and dose constraints except the different gantry rotation time. The gantry rotation time was increased from 30s to 150s by step of 30(30s, 60s, 90s, 120s, and 150s). Plans (VMAT30s, VMAT60s, VMAT90s, VMAT120s and VMAT150s) were normalized so that at least 95% of PTV would receive the prescription dose 50 Gray in 25 fractions. Dose-volume histograms and isodose distributions were evaluated. Conformity indices (CI), homogeneous indices (HI), monitor units (MUs), delivery time were also compared. Results: As the increasing of gantry rotation time, VMAT150s provided comparable organs at risk sparing and better target coverage and conformity than VMAT30s. In the normal tissue such as bladder and femurs, the VMAT plans show almost the same V30 and Dmean for them compared with IMRT plans, meanwhile the conformity indices (CI) was better than IMRT plans(p=0.021). However, there was no significant different among the VMAT60s, VMAT90s, VMAT120s and VMAT150s (p=0.054). VMAT150s increased delivery time and monitor units in plans without improving plan quality compared to VMAT60s, VMAT90s and VMAT120s. Conclusion: VMAT60s, VMAT90s, VMAT120s and VMAT150s achieved comparable treatment plans in rectal carcinoma. Slower gantry movement in VMAT150s only improves slight improvement than the others.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-J-03: Commissioning of the On-Board Cone-Beam CT System Equipped On the Rotating Gantry of a Proton Therapy System

Purpose: Proton therapy requires highly-precise image guidance in patient setup to ensure accurate dose delivery. Cone-beam CT (CBCT) is expected to play an important role to reduce uncertainties in patient setup. Hokkaido University has developed a new proton therapy system dedicated to spot-scanning under a collaborative work with Hitachi Ltd. In our system, an orthogonal X-ray imaging system is mounted on a full-rotating gantry. On-board CBCT imaging is therefore available. We have conducted commissioning of the CBCT system for clinical use in proton therapy. Methods: The orthogonal X-ray imaging system, which consists of two sets of X-ray tubes and flat panel detectors (FPDs), are equipped on the rotating gantry. The FPDs are mounted on the proton beam nozzle and can be retracted when not in use. The distance between the X-ray source and the FPD is about 2.1 m. The maximum rotation speed of the gantry is 1 rpm, so CBCT images can be acquired in approximately 1 minute. The maximum reconstruction volume is nearly 40 cm in diameter and 20 cm in axial length. For commissioning of the CBCT system, mechanical accuracy of the rotating gantry first was evaluated. Imaging performance was examined via quantitative evaluation of image quality. Results: Through the mechanical test, the isocentricity of the gantry was confirmed to be less than 1 mm. Moreover, it was improved to 0.5 mm with an appropriate correction. The accurate rotation of the gantry contributes to the CBCT image quality. In the image quality test, objects with 7 line-pairs per cm, which corresponds to a line spacing of 0.071 cm, could be discerned. Spatial linearity and uniformity were also sufficient. Conclusion: Clinical commissioning of the on-board CBCT system for proton therapy was conducted, and CBCT images with sufficient quality were successfully obtained. This research was supported by the Cabinet Office, Government of Japan and the Japan Society for the Promotion of Science (JSPS) through the Funding Program for World-Leading Innovative R and D on Science and Technology (FIRST Program), initiated by the Council for Science and Technology Policy (CSTP)

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-206-07: CBCT Scatter Correction Based On Rotating Collimator

Purpose: Scatter correction in cone-beam computed tomography (CBCT) has obvious effect on the removal of image noise, the cup artifact and the increase of image contrast. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, the inconvenience of mechanics and propensity to residual artifacts limited the further evolution of basic and clinical research. Here, we propose a rotating collimator-based approach, in conjunction with reconstruction based on a discrete Radon transform and Tchebichef moments algorithm, to correct scatter-induced artifacts. Methods: A rotating-collimator, comprising round tungsten alloy strips, was mounted on a linear actuator. The rotating-collimator is divided into 6 portions equally. The round strips space is evenly spaced on each portion but staggered between different portions. A step motor connected to the rotating collimator drove the blocker to around x-ray source during the CBCT acquisition. The CBCT reconstruction based on a discrete Radon transform and Tchebichef moments algorithm is performed. Experimental studies using water phantom and Catphan504 were carried out to evaluate the performance of the proposed scheme. Results: The proposed algorithm was tested on both the Monte Carlo simulation and actual experiments with the Catphan504 phantom. From the simulation result, the mean square error of the reconstruction error decreases from 16% to 1.18%, the cupping (τcup) from 14.005% to 0.66%, and the peak signal-to-noise ratio increase from 16.9594 to 31.45. From the actual experiments, the induced visual artifacts are significantly reduced. Conclusion: We conducted an experiment on CBCT imaging system with a rotating collimator to develop and optimize x-ray scatter control and reduction technique. The proposed method is attractive in applications where a high CBCT image quality is critical, for example, dose calculation in adaptive radiation therapy. We want to thank Dr. Lei Xing and Dr. Yong Yang in the Stanford University School of Medicine for this work. This work was jointly supported by NSFC (61471226), Natural Science Foundation for Distinguished Young Scholars of Shandong Province (JQ201516), and China Postdoctoral Science Foundation (2015T80739, 2014M551949).

60 APPLIED LIFE SCIENCES↗

Collective rotation from ab initio theory

Through ab initio approaches in nuclear theory, we may now seek to quantitatively understand the wealth of nuclear collective phenomena starting from the underlying internucleon interactions. No-core configuration interaction (NCCI) calculations for p-shell nuclei give rise to rotational bands, as evidenced by rotational patterns for excitation energies, electromagnetic moments and electromagnetic transitions. In this review, NCCI calculations of 7–9 Be are used to illustrate and explore ab initio rotational structure, and the resulting predictions for rotational band properties are compared with experiment. We highlight the robustness of ab initio rotational predictions across different choices for the internucleon interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AmeriFlux FLUXNET-1F US-Ne2 Mead - irrigated maize-soybean rotation site

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Ne2 Mead - irrigated maize-soybean rotation site. This is the FLUXNET version of the carbon flux data for the site US-Ne2 Mead - irrigated maize-soybean rotation site produced by applying the standard ONEFlux (1F) software. Site Description - The study site is one of three fields (all located within 1.6 km of each other) at the University of Nebraska Eastern Nebraska Research, Extension and Education Center near Mead, Nebraska. This site is irrigated with a center pivot system. Prior to the initiation of the study, the irrigated site had a 10-yr history of maize-soybean rotation under no-till management. A tillage operation (disking) was done just prior to the 2001 planting to homogenize the top 0.1 m of soil, incorporate P and K fertilizers, as well as previously accumulated surface residues. Since this tillage operation, the site has been under no-till management in a maize-soybean rotation (maize odd years and soybean even years). There was a brief period due to an intercomparison study from 2010 to 2013 when fall conservation tillage was performed and maize (not soybean) was planted in 2010 and 2012. The management reverted to a strictly no-till maize-soybean crop rotation after 2014.

Suyker, Andy [University of Nebraska - Lincoln]↗

Rotation Fixture Tooling

Lawrence Livermore National Lab has a need to rotate a device 180 degrees partway through device assembly to install components located on the opposite side of the assembly. This rotation operation must be done in a controlled matter to ensure safe handling of the device, which contains delicate instrumentation and hazardous materials. These devices can take several years and millions of dollars to design, manufacture, and build. The device may weigh up to 200 lbs, which exceeds the laboratory limit of 50 lbs for a one man manual lift or 100 lbs for a two man manual lift. In the past, an overhead crane and come-alongs were used to rotate the device, which was a complex operation that presented more opportunities for mistakes than the desired solution. Complexities of the prior solution include the required proper come-along set-up by skilled workers, several come-along configurations during the rotation of the device, and limited control during the rotation operation. A simpler engineered solution is desired.

42 ENGINEERING↗

Calculation of Ground State Rotational Populations for Kinetic Gas Homonuclear Diatomic Molecules including Electron-Impact Excitation and Wall Collisions

A model has been developed to calculate the ground-state rotational populations of homonuclear diatomic molecules in kinetic gases, including the effects of electron-impact excitation, wall collisions, and gas feed rate. The equations are exact within the accuracy of the cross sections used and of the assumed equilibrating effect of wall collisions. It is found that the inflow of feed gas and equilibrating wall collisions can significantly affect the rotational distribution in competition with non-equilibrating electron-impact effects. The resulting steady-state rotational distributions are generally Boltzmann for N≥3, with a rotational temperature between the wall and feed gas temperatures. The N=0,1,2 rotational level populations depend sensitively on the relative rates of electron-impact excitation versus wall collision and gas feed rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗