Automotive absorption air conditioner utilizing solar and motor waste heat

In combination with the ground vehicles powered by a waste heat generating electric motor, a cooling system including a generator for driving off refrigerant vapor from a strong refrigerant absorbant solution is described. A solar collector, an air-cooled condenser connected with the generator for converting the refrigerant vapor to its liquid state, an air cooled evaporator connected with the condenser for returning the liquid refrigerant to its vapor state, and an absorber is connected to the generator and to the evaporator for dissolving the refrigerant vapor in the weak refrigerant absorbant solution, for providing a strong refrigerant solution. A pump is used to establish a pressurized flow of strong refrigerant absorbant solution from the absorber through the electric motor, and to the collector.

Popinski, Z.↗

Cooling system having dual suction port compressor

A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

42 ENGINEERING↗

Test Report #33: Compressor Calorimeter Test of R-410A Alternative: R-32/R-134a Mixture Using a Scroll Compressor

This report investigates the tested performance of lower - GWP candidate refrigerant, 94.07 wt% R - 32 + 5.93 wt % R - 134 a mixture (hereafter referred to as R - 32/134a), as an alternative to baseline refrigerant R - 410 A using a 36,000 Btu/hr compressor calorimeter located at the Heat Exchanger Advanced Testing Facility at Oak Ridge National Laboratory . These tests were conducted during May and August 2013. R - 410A is a near - azeotropic blend of R - 32 and R - 125 with 0.5/0.5 mass fraction and has a GWP 100 of 2100. R - 32 and R - 134a are pure refrigerants and have GWP 100 of 716 and 1370 1, respectively. Based on the GWP 100 values of pure refrigerants and their mass fraction in the blend, GWP 100 of R - 32/134a, which is under development by National Refrigerant, is 755. This report compares various performance parameters, such as cooling capacity, compressor power, refrigerant mass flow rate, EER, isentropic efficiency and discharge temperature of the alternative refrigerant to that of R - 410 A.

42 ENGINEERING↗

TEST REPORT #21: Compressor Calorimeter Test of R-404A Alternatives ARM-31a, D2Y-65, L-40, and R32/ R-134a (50/50)

As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of four lower-GWP alternative refrigerants, ARM-31a, D2Y-65, L-40, and R-32 + R-134a mixture, to that of refrigerant R-404A (baseline) in a scroll compressor designed for medium temperature refrigeration applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-404A and having a nominal rated capacity of 23,500 Btu/hr. Tests were conducted over a suction dew point temperature range of -10°F to 35°F in 5°F increments and a discharge dew point temperature range of 70°F to 140°F in 10°F increments. All the tests were performed with 20°F superheat, 40°F superheat, and 65°F suction temperature. A liquid subcooling level of 10°F to 15°F was maintained for all the test conditions. However, the cooling capacities reported in this study are normalized for 0°F subcooling. The tests showed that the compressor energy efficiency ratio (EER) and cooling capacity with all four alternative refrigerants tested are higher at higher saturation suction and saturation discharge temperature and lower at lower saturation suction and saturation discharge temperature, compared to that of R-404A. Discharge temperatures of all the alternative refrigerants were higher than that of R-404A at all test conditions.

Alternative Refrigerants↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Development of high efficiency window air conditioner using propane under limited charge

The residential air conditioner market has a significant portion of window air conditioners (WAC). Due to the compact size and small refrigerant charge, WACs are most tolerant of flammable refrigerants. Hydrocarbon (HC) refrigerants are natural substances and have significantly better environmental impacts and lower costs than conventional refrigerants like R-410A and R-22. The paper aimed to develop a WAC prototype using propane (R-290) and verify the performance metrics in the laboratory. The key of developing the WAC using a flammable refrigerant is to control the refrigerant charge under the limit of building safety regulation with the performance meeting the Energy Star standard. To minimize the charge, compact heat exchangers were utilized. To achieve the target efficiency, we collaborated with a leading rotary compressor manufacturer to develop a compressor prototype specifically optimized for R-290, able to achieve superior energy efficiency. In addition, we conducted model-based investigations to identify further charge reduction potential. Finally, with using microchannel heat exchangers to replace the fin-and-tube condenser and evaporator, the system charge can be decreased to 150 g.

42 ENGINEERING↗

R410A condensation inside a commercial brazed plate heat exchanger

This paper presents the heat transfer coefficients and the pressure drop measured during HFC-410A condensation inside a commercial brazed plate heat exchanger: the effects of saturation temperature, refrigerant mass flux and vapour super-heating are investigated. The heat transfer coefficients show weak sensitivity to saturation temperature and great sensitivity to refrigerant mass flux and vapour super-heating. At low refrigerant mass flux (<20 kg/m{sup 2} s) the saturated vapour condensation heat transfer coefficients are not dependent on mass flux and are well predicted by Nusselt [W. Nusselt, Die oberflachenkondensation des wasserdampfes, Energy 60 (1916) 541-546, 569-575] analysis for vertical surface: the condensation process is gravity controlled. For higher refrigerant mass flux (>20 kg/m{sup 2}s) the saturated vapour condensation heat transfer coefficients depend on mass flux and are well predicted by Akers et al. [W.W. Akers, H.A. Deans, O.K. Crosser, Condensing heat transfer within horizontal tubes, Chem. Eng. Prog. Symp. Series 55 (1959) 171-176] equation: forced convection condensation occurs. In the forced convection condensation region the heat transfer coefficients show a 30% increase for a doubling of the refrigerant mass flux. The condensation heat transfer coefficients of super-heated vapour are 8-10% higher than those of saturated vapour and are well predicted by Webb [R.L. Webb, Convective condensation of superheated vapor, ASME J. Heat Transfer 120 (1998) 418-421] model. A simple linear equation based on the kinetic energy per unit volume of the refrigerant flow is proposed for the computation of the frictional pressure drop. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Holbrook Substation Superconductor Cable System, Long Island, New York: Final Report ~ Volume 1 [Slides]

The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and safer since it is now a programmed procedure versus the former written procedure that was still subject to human variation in the process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TEST REPORT #11: Compressor Calorimeter Test of R-410A Alternatives R-32, DR-5, and L-41a

As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares performance of alternative refrigerants R32, DR-5, and L-41A to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. Compressor calorimeter tests were performed to evaluate the performance of the lower-GWP alternative refrigerants in place of the common refrigerant R-410A in a 36,000 Btu/hr compressor calorimeter using a compressor having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10°F to 55°F in 5°F increments and a discharge dew point temperature range of 70°F to 140°F in 10°F increments. All the tests were performed with 20°F superheat, 40°F superheat and 65°F suction temperature. A liquid subcooling level of 15°F was maintained for all the test conditions. The tests showed that performance of these three lower-GWP alternative refrigerants is comparable to that of R-410A. For the 20°F superheat and 15°F subcooling test conditions, EERs of R32, DR-5, and L-41A were 90% to 99%, 96% to 99%, and 94% to 101%, respectively, compared to that of R-410A. Similarly, cooling capacities of R32, DR-5, and L-41A were 98% to 103%, 92% to 96%, and 84% to 92%, respectively, compared to that of R-410A.

Alternative Refrigerants↗

Compressor Calorimeter Test of R-410A Alternative: R-32/134a Mixture Using a Scroll Compressor

As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of lower-GWP alternative refrigerant R-32 + R-134a mixture, to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-410A and having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10 F to 55 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat, and 65 F suction temperature. A liquid subcooling level of 15 F was maintained for all the test conditions. The tests showed that the discharge temperature of the alternative refrigerant was higher than that of R-410A at all test conditions. Also, the energy efficiency ratio (EER) and cooling capacity of compressor using the alternative refrigerant were slightly lower in comparison to that of R-410A.

Alternative Refrigerants↗

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump↗

Comparative study of different solar cooling systems for buildings in subtropical city

In recent years, more and more attention has been paid on the application potential of solar cooling for buildings. Due to the fact that the efficiency of solar collectors is generally low at the time being, the effectiveness of solar cooling would be closely related to the availability of solar irradiation, climatic conditions and geographical location of a place. In this paper, five types of solar cooling systems were involved in a comparative study for subtropical city, which is commonly featured with long hot and humid summer. The solar cooling systems included the solar electric compression refrigeration, solar mechanical compression refrigeration, solar absorption refrigeration, solar adsorption refrigeration and solar solid desiccant cooling. Component-based simulation models of these systems were developed, and their performances were evaluated throughout a year. The key performance indicators are solar fraction, coefficient of performance, solar thermal gain, and primary energy consumption. In addition, different installation strategies and types of solar collectors were compared for each kind of solar cooling system. Through this comparative study, it was found that solar electric compression refrigeration and solar absorption refrigeration had the highest energy saving potential in the subtropical Hong Kong. The former is to make use of the solar electric gain, while the latter is to adopt the solar thermal gain. These two solar cooling systems would have even better performances through the continual advancement of the solar collectors. It will provide a promising application potential of solar cooling for buildings in the subtropical region. (author)

14 SOLAR ENERGY↗

Manipulating Pore Topology and Functionality to Promote Fluorocarbon-Based Adsorption Cooling

With the worldwide demand for refrigeration and cooling expected to triple, it is increasingly important to search for alternative energy resources to drive the refrigeration cycles with reduced electricity consumption. Recently, adsorption cooling has gained increased attention since energy reallocation in such systems is based on gas adsorption/desorption, which can be driven by waste/natural heat sources. Eco-friendly sorption-based cooling relies on the cyclic transfer of refrigerant gas from a high to low energy state by the pseudo-compression effect resulting from adsorption and desorption. The driving force for energy transfer relies on heat rather than electricity. The performance of a sorption chiller is primarily influenced by this cyclic sorption behavior, which is characterized as the working capacity of the porous sorbent. Thus increases in this working capacity directly translate to a more compact and efficient cooling system. How-ever, a lack of highly effective sorbent/refrigerant pairs lowers cooling performance, and therefore has limited applicability. To this end, synthetic metal-organic frameworks (MOFs) and covalent organic polymers (COPs) possess higher porosity and greater tunability leading to more substantial potential benefits for adsorption, compared to traditional sorbent materials. Similarly, hydrofluorocarbon refrigerants have more favorable applicability given ease of operation above atmospheric pressures due to suitable saturated vapor pressures and boiling points. For these reasons, our work focuses on an ongoing strategy to promote sorption cooling via improvements in the sorbent/refrigerant pair. Specifically, we target the interaction of hydrofluorocarbon refrigerants with MOF/COP materials at a molecular level by interpreting the host-guest chemistry and the role of framework pore topology. These molecular level differences translate to cooling performance, which is described herein. These strategies include engineering framework porosity (i.e., pore size, pore volume) by using elongated organic linkers and stereochemistry control during synthesis; manipulating the sorb-ate/sorbent interaction by introducing functional moieties or unsaturated metal centers to enhance working capacities in narrow pressure ranges; varying pore topology/morphology to impact adsorption isotherm behavior; and leveraging defective sites within the frameworks to further enhance adsorption capability. Here this atomic level understanding of sorb-ate-sorbent interactions is conducted using various in situ experimental techniques such as synchrotron-based X-ray diffraction, X-ray absorption spectroscopy, in situ Fourier transform infrared spectroscopy, and direct sorption energies determinization with calorimetry. Moreover, the experimentally studied interactions and the corresponding adsorption mechanism are corroborated by computational studies using density functional theory (DFT) and grand canonical Monte Carlo (GCMC) simulations. Using this approach, we envision the capability to engineer designed frameworks with precise molecular control to target refrigerant molecules and thereby enhance the performance of desired working pairs for sorption-based cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning and Testing of a new 4.5K Cold Box for JLab Cryogenic Test Facility

A new 4.5K cold box at Jefferson Lab (JLab) Cryogenic Test Facility (CTF) was recently installed and commissioned to upgrade the existing 4.5 K refrigeration system and work in parallel with the existing 4.5 K cold box. This new 4.5 K cold box is equipped with two turbo-expanders and, at its maximum capacity condition, it is expected to support at least 6.6 g/s of helium liquefaction or 650 W of refrigeration at 4.5 K. It can also handle up to 10 g/s 30 K return flow for 2 K refrigeration recovery that supports cryo-module and superconducting cavity testing. Performances of the cold box at its maximum capacity conditions as well as several other operating modes were tested for acceptance. Finally, we will briefly review the new 4.5 K cold box design features and discuss the commissioning and performance testing results.

42 ENGINEERING↗

Beyond Control: Enabling Smart Thermostats for Leakage Detection

Smart thermostats, with multiple sensory abilities, are becoming pervasive and ubiquitous, in both residential and commercial buildings. By analyzing occupants’ behavior, adjusting set temperature automatically, and adapting to temporal and spatial changes in the atmosphere, smart thermostats can maximize both - energy savings and user comfort. In this paper, we study smart thermostats for refrigerant leakage detection. Retail outlets, such as milk-booths and quick service restaurants set up cold-rooms to store perishable items. In each room, a refrigeration unit (akin to air-conditioners) is used to maintain a suitable temperature for the stored products. Often, refrigerant leaks through the coils (or valves) of the refrigeration unit which slowly diminishes the cooling capacity of the refrigeration unit while allowing it to be functional. Such leaks waste significant energy, risk occupants’ health, and impact the quality of stored perishable products. While store managers usually fail to sense the early symptoms of such leaks, current techniques to report refrigerant leakage are often not scalable. We propose Greina - to continuously monitor the readily available ambient information from the thermostat and timely report such leaks. We evaluate our approach on 74 outlets of a retail enterprise and results indicate that Greina can report the leakage a week in advance when compared to manual reporting

Jain, Milan↗

He-3 cooling systems for space

The development of a space-compatible He(3) refrigerator would provide a significant improvement in several areas of research in the 0.3 to 1 K temperature range. There are several methods of achieving these temperatures on Earth: He(3) refrigeration, dilution refrigeration, and adiabatic demagnetization refrigeration. The progress of adapting He(3) refrigeration for use in space is described. Various cycles and possible embodiments of He(3) refrigerators are described. Also included is an analysis of the liquid confinement and liquid-vapor phase-separation system. A possible configuration is then analyzed. Finally, the results of ground-based experiments will be discussed.

Kittel, P.↗

A small, single stage orifice pulse tube cryocooler demonstration

This final report summarizes and presents the analytical and experimental progress in the present effort. The principal objective of this effort was the demonstration of a 0.25 Watt, 80 Kelvin orifice pulse tube refrigerator. The experimental apparatus is described. The design of a partially optimized pulse tube refrigerator is included. The refrigerator demonstrates an ultimate temperature of 77 K, has a projected cooling power of 0.18 Watts at 80 K, and has a measured cooling power of 1 Watt at 97 K, with an electrical efficiency of 250 Watts/Watt, much better than previous pulse tube refrigerators. A model of the pulse tube refrigerator that provides estimates of pressure ratio and mass flow within the pulse tube refrigerator, based on component physical characteristics is included. A model of a pulse tube operation based on generalized analysis which is adequate to support local optimization of existing designs is included. A model of regenerator performance based on an analogy to counterflow heat exchangers is included.

Hendricks, John B.↗

MULTI-SCALE MODELING AND APPROXIMATION ASSISTED OPTIMIZATION OF BARE TUBE HEAT EXCHANGERS

Air-to-refrigerant heat exchangers are very common in air-conditioning, heat pump and refrigeration applications. In these heat exchangers, there is a great benefit in terms of size, weight, refrigerant charge and heat transfer coefficient, by moving from conventional channel sizes (~ 9mm) to smaller channel sizes (< 5mm). This work investigates new designs for air-to-refrigerant heat exchangers with tube outer diameter ranging from 0.5 to 2.0mm. The goal of this research is to develop and optimize the design of these heat exchangers and compare their performance with existing state of the art designs. The air-side performance of various tube bundle configurations are analyzed using a Parallel Parameterized CFD (PPCFD) technique. PPCFD allows for fast-parametric CFD analyses of various geometries with topology change. Approximation techniques drastically reduce the number of CFD evaluations required during optimization. Maximum Entropy Design method is used for sampling and Kriging method is used for metamodeling. Metamodels are developed for the air-side heat transfer coefficients and pressure drop as a function of tube-bundle dimensions and air velocity. The metamodels are then integrated with an air-to-refrigerant heat exchanger design code. This integration allows a multi-scale analysis of air-side performance heat exchangers including air-to-refrigerant heat transfer and phase change. Overall optimization is carried out using a multi-objective genetic algorithm. The optimal designs found can exhibit 50 percent size reduction, 75 percent decrease in air side pressure drop and doubled air heat transfer coefficients compared to a high performance compact micro channel heat exchanger with same capacity and flow rates.

CFD↗