Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECOMMENDATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Hawai‘i Play Fairway (Final Report)

Most of Hawai'i's geothermal resources are blind—their manifestations, such as hot springs and steam vents, do not appear on the ground surface because the heated water flows far below. With the exception of $K\bar{i}lauea East Rift Zone$, in most areas of Hawai'i, high lateral permeability in the first kilometer below ground surface prevents surface thermal features from developing. As a methodology for discovering these blind resources, Play Fairway Analysis (PFA) involves finding potential locations of blind hydrothermal systems and describing potential geothermal sources in rift-zone settings. Using the PFA to find Hawai'i's geothermal resources, the University of Hawai'i (UH) conducted the Hawai‘i Play Fairway Project, Hawai'i's first statewide geothermal resource assessment since 1985. Sponsored by the U.S. Department of Energy, the Hawai'i Play Fairway Project provided an updated resource assessment, a roadmap for additional exploration activities, and the identification of areas for further exploration. Benefitting from UH's core competency in earth sciences and experienced geothermal researchers, the project comprised three phases. During the first phase, the team identified, compiled, and ranked existing geologic, groundwater, and geophysical datasets relevant to subsurface heat, fluid and permeability. Using a Bayesian statistical approach, the team developed a statistical methodology to integrate these data into a resource probability map. The team evaluated the confidence in the probability value and considered development viability of areas with geothermal resources. With these analyses, the team identified 10 locations in the Hawaiian Islands for exploration activities. For the second phase, the team collected new groundwater data in 10 locations across the state and new geophysical data on $L\bar{a}na‘i, Maui$, and central Hawai'i Island and modeled topographically induced stress to better characterize subsurface permeability. Analyzing the subsurface stresses, the team evaluated the potential for fracture-induced permeability. The team inverted the MT and gravity data to produce 3D models of resistivity and density, respectively, on $L\bar{a}na‘i$, across $Haleakal\bar{a}'s$ SW rift (Maui), and surrounding Mauna Kea (Hawai‘i Island). The team developed and applied a new method for incorporating depth information about resistivity, density, and potential for fracture-induced permeability into the statistical method for computing resource probability in these three focus areas. The team incorporated the new groundwater results with the new geophysical results and the calculations of potential for fracture-induced permeability to produce updated maps of resource probability and confidence. Through combining data from the first and second phases, the team determined locations for further exploration during the third phase. For MT and gravity surveys, the team recommended $Kaua'i's$ $L\bar{i}hu'e$ $Basin$, the east rift of $Maui's$ $Haleakal\bar{a}$ volcano, and the southwest rift of Hawai'i Island's Mauna Loa volcano. The MT and gravity surveys aimed to enable improved confidence in the resource potential in these locations. For drilling deep groundwater well(s), the team recommended Southeast Mauna Kea and $L\bar{a}na's$ $P\bar{a}l\bar{a}wai$ $Basin$. During the third phase, further exploration involved drilling a groundwater well in $L\bar{a}na's$ $P\bar{a}l\bar{a}wai$ $Basin$ and performing more geophysical surveys. We deepened an existing water well proximal to our target area on $L\bar{a}na'i$ due to funding constraints that precluded us from spudding a new well that would exceed 1km depth. Drilling was preceded by a number of substantial elements including: writing an Environmental Assessment and the subsequent legal process, performance of deviation logging, lowering a camera down the well, coordinating site preparation with $P\bar{u}lama$ $L\bar{a}na'i$, shipping the UH-owned rig interisland, procuring supplies, and leading 3 community meetings on $L\bar{a}na'i$. Drilling occurred 24/7 the entire month of June 2019 over which time $L\bar{a}na'i$ $Well$ 10 was deepened from 427 m to 1057 m, with continuous core collected. We measured a roughly linear temperature gradient averaging 42°C/km and a maximum bottom hole temperature of 66°C. This gradient is more than twice the background for Hawai'i and within a range of gradients measured in this depth range for some exploration wells within KERZ. We consider these results encouraging for $L\bar{a}na'i's$ resource potential and recommend following with a slim hole within $L\bar{a}na'i's$ caldera (our target zone) to ~ 2 km. Further, the positive implications such results have for the island of O‘ahu are substantial - the shield stage of O'ahu's volcanoes ended 1-2 My earlier. However, O'ahu uses more electricity than the rest of the islands combined, and the utility recently called for 500-700MW of firm, dispatchable renewable electricity on O'ahu by 2033. In Phase 3, we also collected limited new encouraging groundwater data, and updated our thoughts on the probabilities of fluid and permeability at resource depths (Pr F = 1; Pr P = mostly unconstrained). Ultimately, we advocate for using our final probability of heat, and confidence in this probability, to drive the next phase of exploration. We contend further development of geothermal in Hawai‘i will enable the state to achieve its 100% renewable policy objective and Hawai'i to transition off of fossil fuels through geothermal discovery and development. The project not only produced a large amount of data and expanded the existing knowledge of Hawai'i's geothermal resources, but also produced publications, theses, presentations, core photos, datasets, media reports, television interviews, community events, and a blog. Students and new professionals benefitted from the project's hands-on research experiences and educational opportunities and earned awards and recognition.

15 GEOTHERMAL ENERGY↗

ORNL Second Target Station Project: Biological & Environmental Science Workshop

Recent advances in neutron sources and instrumentation have opened up many new opportunities for the application of neutron scattering techniques in the biological and environmental sciences. Neutrons enable studies of the structure and dynamics of biological and environmental samples with a particular sensitivity to light elements, such as hydrogen, which is a key component of biological and environmental samples. Studies using neutrons are complementary to X-rays and have the unique advantage of being non-destructive and highly-penetrating. Oak Ridge National Laboratory’s upcoming Spallation Neutron Source (SNS) Second Target Station (STS) will provide high brightness cold neutron sources that significantly advance the scientific capabilities of neutron scattering instruments. The STS will advance our understanding of biological and environmental processes across spatial and temporal scales. The capabilities will enhance our ability to discover, design, and develop new materials essential for advanced sustainable technologies to address society’s most pressing needs. This report summarizes the discussions and recommendations from a joint workshop held by the STS Project and the Biological and Environmental Systems Science Directorate (BESSD) in June 2022. The purpose of the workshop was to explore science opportunities and capabilities related to biological and environmental systems that could be incorporated into both current and future STS instrument designs, as well as additional instruments at the SNS First Target Station (FTS) and High Flux Isotope Reactor (HFIR). With six breakout sessions, each with two invited plenary speakers from other institutions, the participants discussed a wide range of topics relevant to biological and environmental research. Based on the input from participants, a number of recommendations on instrumentation, sample environments, complementary multi-modal methods, data processing and analysis and sample deuteration are provided in the report. The participants also identified science opportunities that are emerging from the planned instrument capabilities at STS. Selected recommendations and science opportunities are listed in the Executive Summary.

54 ENVIRONMENTAL SCIENCES↗

Independent Review of Groundwater Remediation Strategy for Hexavalent Chromium and RDX Groundwater Plumes at Los Alamos National Laboratory (Rev. 1)

Site operations at the Los Alamos National Laboratory (LANL) resulted in the release of oxidized chromium, Cr(VI), into Sandia Canyon from cooling tower effluent from 1956 until 1972. The chromium traveled with the surface water approximately 3 miles downstream before migrating below ground surface. Chromium concentrations exceed 50 μg/L in the upper portion of the aquifer. Another LANL groundwater plume of concern is associated with RDX (Royal Demolition Explosives, 1,3,5-trinitro-1,3,5-triazine). Between 1951 and 1996, RDX was released to the mesa-top facilities' process water outfall, adjacent and underlying soils, and alluvial sediments, along with surface water in Cañon de Valle. Between 2000 and 2010, two remedial actions were deployed, removing much of the near-surface RDX, however, recharge due to precipitation has transported RDX into the perched-intermediate zone and into the regional aquifer. The report documents an independent technical review by scientists from the Department of Energy (DOE) Network of National Laboratories for Environmental Management and Stewardship (NNLEMS) to provide recommendations for potential near term actions to address and optimize remediation for both the Cr(VI) and RDX plumes. The proposed near-term remedial actions include design of pump and treat systems for Cr(VI) and monitoring and study for natural attenuation for RDX. The review assesses existing data, conceptual and numerical modeling, and it recommends a technical integration process to support identifying and implementing strategic, effective and efficient remedies. The DOE Environmental Management Los Alamos Field Office (EM-LA) and their cleanup contractor Newport News Nuclear-BWTX, LLC Los Alamos (N3B) provided the information required for the review. Interviews were also conducted with regulators to obtain the full spectrum of technical, regulatory and scientific perspectives. The independent review team was impressed by the capabilities, experiences, innovativeness, and insightfulness of the technical representatives from both the regulator, the New Mexico Environment Department (NMED) and N3B. Incorporation of vadose zone flow pathways in the conceptual site model (CSM) and configuring the numerical modeling for the site was generally state-of-the-practice (or better). This could be considered state-of-the-art by addressing uncertainties related to spatial extent of hydraulic windows. The reviews from the regulators were thorough and often provided useful concepts for consideration and future/study resolutions. The overarching consensus recommendation of independent review team is that the LANL groundwater plumes should be addressed in context of the emerging "management of complex sites" paradigm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Property-Composition Models for Support of Hanford WTP LAW Facility Operation

Current plans for the River Protection Project envision starting to vitrifying low-activity waste (LAW) by 2023 using a Direct Feed Low-Activity Waste (DFLAW) approach and subsequently using a full-pretreatment approach. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW Facility will be operated and controlled using a LAW glass formulation algorithm (GFA), which requires several inputs based on research and development results. LAW glass property-composition models for several product quality and processing properties are key inputs for the LAW GFA. It is envisioned that the preliminary LAW GFA discussed by Kim and Vienna (2012) will be used for commissioning and initial radioactive operations of the WTP LAW Facility under Bechtel National, Inc. using the DFLAW approach. Then, an updated LAW GFA will be developed for implementation by the WTP operating contractor that takes over after WTP LAW Facility commissioning. This report documents the enhanced LAW glass property-composition models developed for use in the updated LAW GFA. The properties for which models were developed include Product Consistency Test (PCT) response, Vapor Hydration Test (VHT) response, viscosity at 1150 °C, electrical conductivity at 1150 °C, melter SO3 tolerance at 1150 °C, and K-3 refractory corrosion at 1208 °C. Table S.1 lists the tables in this report that contain the recommended models for each of these properties. The model types recommended include partial quadratic mixture (PQM) models for viscosity, electrical conductivity, melter SO 3 tolerance and K-3 corrosion, bias corrected PQM model (bcPQM) for PCT, and logistic PQM model for VHT. The fits of model and validation subsets were found to be well predicted by the recommended models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Technical Report

Statement of the problem or situation that is being addressed in your application. The DOE and its national laboratories developed the Home Energy Score™ (HES) to encourage homeowners to improve their energy performance, lower costs and to share energy information through the MLS listing, appraisal, and financing channels. While the HES is an instrumental tool, it is currently underutilized and consists of technical, structural and sector barriers which need to be addressed in order to scale and many energy efficiency contractors are understandably overwhelmed by the added time and effort and lack of incentive to sell and deliver deep retrofit projects while simultaneously meeting the DOE HES program requirements; consequently, contractors may decide to forgo participation. Home Energy Rating System (HERS) Raters have the opportunity to play the critical Assessor role in producing a Home Energy Score (HES); this role has immense potential but currently is unfulfilled. Lastly, while utilities are interested in their customer base achieving greater energy efficiency, especially to help offset growing residential loads in states like California that are accelerating electrification, utilities do not have access to the market actors who are on the front line of influence to homeowners or review and approve their permits: HERS Raters, assessors, contractors and building departments. General statement of how this problem is being addressed: ConSol will integrate the Home Energy Score™ (HES) to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California (CHEERS+HES). The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the utilities in supporting existing homes in their jurisdictions with HES and develop measures to improve energy efficiency and reduce emissions. How is this problem being addressed? What is the overall project approach? In effort to expand the Home Energy Score™ (HES) by increasing the use of aggregable home energy asset data, ConSol proposes to integrate the DOE HES via Application Programming Interface (API) to its State of California approved home energy rating services platform (CHEERS). Once the CHEERS platform and HES are integrated (CHEERS+HES), this enhanced platform will be instantly available and actively deployed via Phase 1 pilot to HERS Raters, assessors and contractors in California to market-test the solution, understand the rate of adoption and identify opportunities for improvement prior to scaling nationally. The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the building industry and homeowners with an easy-to-use assessment if energy and carbon impacts of existing homes, and assist the utilities in supporting existing homes in their jurisdictions with HES to improve energy efficiency and reduce emissions. What is to be done in Phase I? During Phase I of this proposed project, ConSol will (1) design software architecture that links CHEERS to the Home Energy ScoreTM via API, (2) solicit partnership from one or more California utilities for a regional pilot, (3) test the new software with its HERS Raters and contractor network in the partnership utility jurisdiction, (4) launch a pilot version of the newly developed software with HERS Raters and contractors in the utility territory, and (5) explore California’s GoGreen energy efficiency homeowner lending program in parallel with the pilot. Commercial Applications and Other Benefits. Summarize the future applications or public benefits if the project is carried over into Phase II or Phase III and beyond. The CHEERS+HES commercialized product will be ready for national market scale following a successful Phase 1 performance. The CHEERS+HES adoption is estimated to reach a 5% adoption growth rate versus the 110,000 baseline, starting in Year 1 after Phase I completion, and continuing each year. As a direct benefit to the DOE, CHEERS will set a goal of 100,000 Home Energy Score assessments for existing home alterations within the first 10 years following Phase 1 performance. The technical benefits of this proposed project include the harmonized, automated, and seamless integration of the DOE HES into the widely used and market leading California energy registry, CHEERS. The social benefits include the aggregate energy, cost and GHG savings by allowing the broader public streamlined access to the CHEERS+HES measurement and the energy efficiency recommended measures that may result. Key Words: Home Energy ScoreTM (HES); Application Programming Interface (API); Home Energy Rating Services (HERS); HERS Raters; contractors; assessors; existing homes, energy asset data; cost, energy, and emissions saving measures; energy code (Title 24) compliance; document repository; utilities; pilot; newly developed software; energy efficiency; homeowner. Summary for Members of Congress: The DOE Home Energy Score™ (HES) is a tool to encourage homeowners to improve their energy performance, lower costs and share energy information but is underutilized and consists of barriers which need to be addressed in order to scale. In effort to expand the HES, CHEERS, Inc. will integrate the HES to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California.

Application Programming Interface (API)↗

“Shoulda, Coulda, Woulda”: Conceptualizing the Differences in Trust Between Human-Human Teaming and Human-Machine Teaming

Intelligent decision support systems (IDSSs) are machine teammates designed to facilitate better human decision-making in high-consequence domains such as health care, power grid operations, and fraud detection. IDSSs identify patterns in datasets and provide intelligent decision-making recommendations to human teammates. However, previous research indicates that humans often trust IDSS recommendations less than the recommendations from their human teammates, even when the machine teammate is more accurate. To conceptualize why trust differs, we review the literature surrounding trust, error, and predictability. Then, we compile and compare participant trust ratings and decision-making in an abridged systematic review of previous studies manipulating teammate type, error rate, and error type. Finally, we conduct a content analysis of participants’ qualitative responses to trust queries from a survey on generative language models. Results suggest that humans may trust IDSS teammates less than other human teammates because of differences in (1) interaction complexity, (2) blame attribution, and (3) swift trust. We conclude that human factors practitioners should collaborate with data scientists and domain experts to build and maintain trust in IDSSs by anthropomorphizing algorithms, matching mental models, and considering individual differences.

97 MATHEMATICS AND COMPUTING↗

Radiological Dispersal Device (RDD) Recovery Guidance: After Action Report from Pilots - Responding to Feedback from Pilots Reviewing RDD Recovery Guidance

The goal of this After Action report is to utilize feedback from the pilot participants to improve the guidance for responding to radiological dispersal device (RDD) events, which can include deliberate acts to release radioactive materials into the environment using explosives or other means or accidental releases (e.g., release from a medical isotope source). This longer-term recovery guidance is an extension of the initial response guidance that was released in a 2017 interagency report called RDD Response Guidance: Planning for the First 100 Minutes. Recovery teams reviewed the longer-term recovery guidance during pilot sessions that were held in Harris County, Texas (March 8-10, 2022) and Seattle, Washington (May 2-3, 2022). The pilot teams reviewed the RDD Recovery Guidance Presentation, which contains a summary of the more detailed RDD Recovery Guidance draft document. The feedback from both pilots was grouped and binned into unique themes (e.g., “checkpoint challenges”) that align with the recovery missions and tactics that they reviewed. PNNL authors of the recovery guidance then prepared responses that describe how they recommend addressing the feedback for each theme. The responses typically included recommendation plans for improving the guidance document, but also described when no changes are needed because the guidance already contains the suggested improvement. These pilot recommendations will be brought to the interagency team to finalize plans for updating and improving recovery guidance materials.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of Baseline Monitoring Data for the Remote-Handled Low-Level Waste Disposal Facility at Idaho National Laboratory

The purpose of this document is to summarize environmental monitoring data collected at the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility during the first four years of facility operations (FY 2019 through FY 2022). This summary provides a “baseline” condition for the facility, which can be used to distinguish contaminant releases from the RHLLW Disposal Facility from pre existing contamination as well as potential future releases from other sources (i.e., upgradient aquifer sources), as specified in the facility monitoring plan. Sufficient data has been collected over the first four years of operation of the RHLLW Disposal Facility to establish baseline conditions for future compliance monitoring of aquifer wells and performance monitoring of vadose zone lysimeters. Except for seven elevated tritium measurements from lysimeter HFEF-South believed to have been impacted by waste disposals, all data was deemed appropriate for establishing baseline concentrations. Monitoring of the aquifer detected indicator analytes gross alpha and gross beta and target analytes tritium and C-14. There were a few C-14 detections prior to an increase in the required detection level (RDL) after the first round of sampling. I-129 and Tc-99 were not detected above RDLs in aquifer samples. Lysimeter samples detected indicator analytes gross alpha and gross beta and target analyte tritium. Target analytes C-14, I-129, and Tc-99 were not detected above RDLs in lysimeter samples. Except for tritium, baseline concentrations of indicator and target analytes measured during the first four years of RHLLW facility operations are expected to represent conditions through the expected 20 year operating period of the facility. Elevated tritium in the aquifer, a result of past discharges of tritium at upgradient facilities, showed a decline over the first four years of operations, and levels are expected to continue to decline with time as a result of dilution and decay. Current tritium levels in lysimeter samples may be elevated due to tritium in the water applied during construction and infiltration testing of the facility. As a result, tritium concentrations in lysimeters may decline with time as a result of dilution and decay. Statistical measures (i.e., mean, standard deviation, and 99% upper confidence level [UCL]) were calculated for all detected analytes using the four years of concentration data. These measures will be used to evaluate future monitoring results and to demonstrate the facility is performing, or not performing, as established in the facility performance assessment (PA). Future monitoring results will also be combined with the baseline data in this report to further establish temporal trends and natural variability in the measurements. Based on the data collected during the baseline period, it is recommended the gross alpha action level for performance monitoring increase from 10 to 20 pCi/L due to several baseline measurements exceeding the preliminary action level of 10. An action level of 20 pCi/L is slightly greater than the 99% UCL, is protective of the aquifer, and would reduce unnecessary sampling. It is also recommended that tritium be added to the lysimeter analyte list for post-baseline period monitoring. Tritium, while not a dose concern, is a good tracer that can provide valuable information on water flow in and around the RHLLW Disposal Facility. Recommendations for a tritium action level are provided if considered necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Technologies for Destruction of LDR Organics in Hanford Tank Waste

Aqueous Hanford tank wastes contain soluble organics and some tanks contain small amounts (<100 mg/L) of organics that are regulated under the Land Disposal Restrictions (LDR) portions of the Resource Conservation and Recovery Act (RCRA). Most of these organics can be removed by evaporation, but some are not. Methods to destroy/remove organics that are regulated by the LDR section of the RCRA and that are not removed by evaporation may be needed if ambient temperature waste treatment processes are used to immobilize aqueous Hanford tank wastes. To identify viable and compatible organic removal or destruction pretreatment methods an evaluation was performed by a team of researchers. The team utilized a Systems Engineering Approach that examines all aspects of the technology, based on information available in the literature and the experience of the team members. That evaluation led to recommendations by the team to perform testing on technologies to determine efficacy in destroying organics in Hanford tank waste liquids. The primary technologies recommended are chemical oxidants, including permanganate, peroxymonosulfate or peroxydisulfate (PMS/PDS), hydrogen peroxide, and ozone. Ultraviolet light irradiation of the stream with a solid catalyst sorbent is also recommended for testing. A generalized description of the test program is also included.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnification Determination for AGHCF Metallographic Images

Metallographic images generated in the Alpha Gamma Hot Cell Facility (AGHCF) have been used for quantitative and qualitative characterization of irradiated metallic fuel pins. Individual high-magnification images (micrographs) contained in AGHCF file folders and experimental notebooks are in the form of polaroid photographs labeled with AGHCF identification number, magnification, and surface condition (as-polished or etched). Low magnification composite images (photomosaics) are also available for fuel cross sections, for radial strips from the fuel center to the cladding outer diameter, and for circumferential strips of the cladding and outer fuel region. The individual images do not have scale bars. Only a few of the composite images contain scale bars. The purpose of this work is to describe and apply methods for checking the magnification (50X to 500X) of individual images and for determining the magnification (~25X to ~100X) of composite images. The metallographic images used to verify and/or determine magnification were generated during the 1989 to 1993 timeframe for cross sections of U-10Zr/HT9 fuel rods irradiated in EBR-II and for cross sections of irradiated U-10Zr/HT9 fuel-rod samples following elevated-temperature tests conducted in the out-of-pile AGHCF Fuel Behavior Test Apparatus (FBTA). Procedures are documented in the AGHCF Operations Manual for preparation of metallographic samples, for calibration verification, and for constructing composites from individual images. Calibration verification of magnification was performed at least semiannually. One standard used for calibration verification was a glass slide with vertical lines indicating distances of 1 mm, 0.1 mm and 0.01mm. Guidance is provided in the current work for determining magnification from images of the standard. In addition to the periodic calibration verification, consistency checks are recommended to verify the magnification of images taken between the routine calibration verifications. For cladding samples with or without significant fuel-cladding chemical interaction (FCCI), images taken at different magnifications (e.g., 150X and 200X) of the unaffected cladding thickness can be compared. This process is independent of changes in cladding thickness due to swelling and creep. For images taken at only one magnification of cladding regions with no FCCI, the cladding thickness determined from the images may be compared to the nominal as-built cladding thickness (15.0 ± 0.5 mils for examples used in current work)). This procedure works best for cladding that has not experienced significant swelling and/or creep (e.g., ≤2% circumferential strain at the cladding outer surface). Composite images were constructed by pasting together higher magnification images and photographing the composite to generate a negative from which the hard-copy photograph was developed. The primary purpose of the composite images was to identify interesting areas of the fuel and cladding for imaging at higher magnification. However, procedures are recommended in the current work for determining composite magnifications to allow quantitative characterization of the fuel. Composites are not recommended for determining cladding thickness or FCCI depth because magnifications are too low (generally ≤110X) and image contrast is low. Fuel cross-section composites were created by pasting together 50X or 75X images. The nominal magnification for the photographed fuel cross-section composites is 25.4X. A more precise magnification can be determined by comparing the average cladding outer diameter measured from the composite to the average cladding outer diameter measured by profilometry. Radial-strip composites were constructed by pasting together high-magnification (150X or 250X) images. The nominal magnification of radial-strip composites photographs is about 100X. A more precise method for determining the magnification of radial strips is to compare the cladding thick

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Historic Architectural Resource Survey of the Dosimetry Applications Research (DOSAR) Facility in the 7700 Area of the Oak Ridge National Laboratory

In May 2022, Cultural Resource Analysts, Inc., completed a historic architectural resource survey of buildings associated with the Dosimetry Applications Research Facility at the Oak Ridge National Laboratory. The laboratory is one of three Department of Energy facilities located on the Oak Ridge Reservation in Roane and Anderson Counties, Tennessee. The Dosimetry Applications Research Facility is located approximately 2 mi southeast of the main Oak Ridge National Laboratory campus. The survey included Buildings 7709, 7710, and 7712, which date to the 1960s. An additional DOSAR building (Building 7735) dates to the late 1980s and was not surveyed since it is outside the period of significance. The survey was conducted at the request of UT-Battelle, LLC, on behalf of the Department of Energy. As stipulated by the National Historic Preservation Act of 1966, as amended, the Department of Energy is required to identify any properties under its jurisdiction that are included in or eligible for inclusion in the National Register of Historic Places. In order to identify historic properties at the Oak Ridge National Laboratory, in 2017–2018 Cultural Resource Analysts, Inc., conducted a survey of the main campus as well as outlying facilities, publishing the findings in a 2018 report entitled Oak Ridge National Laboratory Historic Architectural Resource Survey. At the time of the 2017–2018 survey, buildings associated with the Dosimetry Applications Research Facility were not accessible for security reasons and the current report serves as an addendum to the 2018 report. In addition, the current survey incorporates information included in a documentation report on Building 7709 completed in 2019. The properties included in the current survey were also evaluated for their collective potential as a historic district. The identification of archaeological properties that are eligible for inclusion in the National Register of Historic Places is beyond the scope of this report. Cultural Resource Analysts, Inc., recommends that none of the buildings surveyed for the current report are individually eligible for listing in the National Register of Historic Places. However, the collective of buildings represents a facility that made notable contributions to the Oak Ridge National Laboratory’s scientific research endeavors from the 1960s to the 1980s, specifically in the field of Health Physics. The buildings and their associated features have also maintained their integrity of setting, materials, design, location, and association. Therefore, Cultural Resource Analysts, Inc., proposes the Dosimetry Applications Research Facility Historic District, which is recommended eligible for listing under Criterion A. The three buildings addressed in the current survey (Buildings 7709, 7710, and 7712) are recommended eligible as contributing resources of the historic district. The district boundary is scribed to incorporate the environs of these three facilities, as well as additional relevant features.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

LANL Meteorological Program Self-Assessment 2023 Update

The DOE Meteorological Coordinating Council (DMCC) conducted an initial LANL Meteorological (Met) Program Assist Visit in August 2006, and several observations and recommendations were shared with LANL management (DMCC 2006). In August 2015, a follow-up Met Program Assist Visit was conducted to determine progress in meeting all the observations and recommendations from the prior Assist Visit (DMCC 2015). During the 9 years between these two Assist Visits, DMCC noted that significant program improvements were made, and these were documented in the 2015 Assist Visit observations and recommendations. Based on current discussions with the Met Program, additional significant improvements have been made and will be discussed as part of this self-assessment.

54 ENVIRONMENTAL SCIENCES↗

A Program Design Combining Community Solar and Weatherization for Manufactured Homes in Michigan

The Michigan Department of Environment, Great Lakes, and Energy (EGLE) is interested in combining community solar with weatherization programs for manufactured homes. To collect program strategies, EGLE made a request for technical assistance from the US Department of Energy’s National Community Solar Partnership (NCSP). Lawrence Berkeley National Lab developed this study in response. It briefly reviews issues relevant to the question, attempts to lay out a methodology for more in-depth analysis, and provides some recommendations for program design and implementation. While the research is specific to Michigan, the recommendations and methodologies could serve as an example for other states and regions. The paper first provides an overview of manufactured home communities in Michigan, with a discussion of demographics and energy issues they face. It then discusses weatherization opportunities for manufactured homes, opportunities for community solar, and opportunities for combining the two. The methodology proposed is intended to help EGLE: -Identify priority locations, -Set eligibility criteria for communities and households, and -Make the most of federal and other funding sources The paper concludes with recommendations for a program that combines community solar with efficient electrification of manufactured homes to reduce the burden of the largest source of energy expenditure in Michigan, winter heating bills. Specifically, it envisions community solar subscriptions for occupants of manufactured homes that have been converted to high-efficiency cold weather heat pumps. The combination can be managed to alleviate seasonal variations in both solar and heating bills, such as through an annualized “budget billing” program.

14 SOLAR ENERGY↗

Pathways to Discovery in Astronomy and Astrophysics for the 2020s

We live in an extraordinary period of discovery in astronomy and astrophysics. Six Nobel Prizes have been awarded over the past decade alone for discoveries based on astronomical data (dark energy, gravitational waves, neutrino oscillations, the discovery of exoplanets, cosmology, and supermassive black holes). Many of the ambitious scientific visions of the 2010 New Worlds, New Horizons (Astro2010)1 decadal survey are being fulfilled, but momentum has only grown. We stand on the threshold of new endeavors that will transform not only our understanding of the universe and the processes and physical paradigms that govern it but also humanity’s place in it. This report of the Committee for a Decadal Survey on Astronomy and Astrophysics 2020 (Astro2020) proposes a broad, integrated plan for space- and ground-based astronomy and astrophysics for the decade 2023–2032.2 It also lays the foundations for further advances in the following decade. This is the seventh in a sequence of decadal survey studies in this field from the National Academies of Sciences, Engineering, and Medicine. This survey examines the program of record, providing advice on the major projects from prior surveys that are yet to be completed. It also lays out priorities for future investments driven by scientific opportunities. The recommendations in this report advance foundational activities that support the people who drive innovation and discovery, and that promote the technologies and tools needed to carry out the science. The report also recommends sustaining activities on a broad range of cost and time scales, as well as activities that enable future visionary projects by maturing them scientifically and technically. Last, the recommendations set in motion the construction of frontier facilities that will change the view and understanding of the cosmos. The survey is bounded by plausible budget scenarios based on briefings from the sponsoring agencies— the Department of Energy (DOE), the National Aeronautics and Space Administration (NASA), and the National Science Foundation (NSF). Within these bounds, the survey aims high, reflecting this time of great scientific promise and progress, with opportunities to pursue some of the most compelling scientific quests of our times.

79 ASTRONOMY AND ASTROPHYSICS↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Transfer Factors for the FRMAC Assessment Manual and Turbo FRMAC to Improve Radiological Dose Assessment

The Turbo FRMAC analysis tool is used to perform complex calculations to quickly evaluate radiological consequences and aid in decision making during an emergency response by assessing impacts to the public, workers, and the food supply. Turbo FRMAC calculations are based on methods established by the Federal Radiological Monitoring and Assessment Center (FRMAC). To be able to assess impacts, input data called transfer factors that describe radionuclide uptake by local plants and animals are required. During the code application exercises in late 2016, identifying, finding, and validating nonstandard transfer factors proved to be time consuming and diverted the teams’ activity away from other critical tasks. As a result, a task was undertaken to dramatically expand the list of available transfer factors (food and non-food) and incorporate these factors into Turbo FRMAC. This will ultimately result in improved efficiency of the assessment team to perform calculations during times when the FRMAC is activated and provide more defensible, vetted data from which to calculate results. As a result of these and subsequent exercises, transfer factors were needed for the following items: bell peppers, Christmas tree, deer, flowers, fresh cucumbers, tomatoes, grapefruit, lichens, mushrooms, oranges, snap beans, squash, strawberries, sugarcane for sugar and seed, sweet corn, tea, tobacco, tree bark, and watermelon. To expand the applicability of the information tables, generic transfer data were also provided for common categories and recommendations were made for expanding the list of chemicals based on chemical similarity. The data presented in this report were compiled from recent literature with most of the data encompassing the period from 2000 to 2018. The following radionuclides were targeted during the literature search: elements associated with reactor accidents or nuclear detonations (Sr 89/90, Cs 134/137, Ce 141/144, Ru 103/106, I 129/131/133, Pu 238/239, Am 241, Zr 95, and Nb 95) and elements associated with industrial accidents or dirty bombs (Ir 192 and Co 60). Data from other elements were evaluated if they were identified during the literature search. In addition, reports were evaluated that were recommended by the research consultants. For each plant or animal transfer factor, the goal was to determine the geometric mean, the geometric standard deviation, the minimum, the maximum, and the number of measurements used. If only one measurement was available that was presented as the mean. Concentration ratios with large geometric standard deviations (GSDs) were generally the result of a paucity of measurements or a few disparate measurements. Measurement disparity was observed for data from different soil types. The geometric mean (GM) is a good reference value for planning and responses purposes, but the location-specific concentrations are unlikely to be similar to the model results. Recommendations for further work include: segregating the data to reflect the influence of soil type, developing approaches to incorporate animal data based on aggregated transfer measurements, and including data for foliar deposition on plants.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

Cybersecurity Lessons Learned from Vehicle to Grid Engagement

As the transportation industry continues to become electrified, introduction of additional digital devices within associated actions such as recharging bring additional potential for cybersecurity attacks. Devices that are designed, implemented, and operated with cybersecurity as a crucial consideration exacerbate these concerns by failing to provide strict boundaries on access to and use of the equipment. Emerging use cases such as Vehicle to Grid (V2G) charging may expand the potential physical effects of a cybersecurity attack by providing indirect access to electrical components of a building microgrid or portions of the larger power grid. This paper serves as an overview of findings and recommendations based on cybersecurity testing performed at a V2G implementation site operated by a member of the Memorandum of Understanding (MOU) to Establish the Vehicle-to-Everything (V2X) Collaboration [1]. The Department of Energy Office of Cybersecurity, Energy Security, and Emergency Response is a signatory of the MOU, and has funded this research paper and associated body of work regarding V2X cybersecurity. Sandia has a large background of previous research focused on Electric Vehicle (EV) cybersecurity, such as reference [2], which includes an overall survey of EV infrastructure cybersecurity and recommendations based on those findings. This report seeks to expand knowledge of EV cybersecurity status and needs by focusing on a specific implementation of V2G charging, and providing recommendations based on the relevant findings. This report serves as a publicly available, sanitized description of applied vulnerability testing on an operational V2G implementation. A more in-depth technical version of the report is provided to the MOU partner, but not available at the time of writing due to inclusion of proprietary information. V2G charging comes with many research problems that must be solved before the technology can securely implemented in sites with unrestricted public access or where cybersecurity attacks could have increased consequences, such as government offices. V2G charging requires many stakeholders such as end users, host sites, equipment vendors, and integrators, which all rely on operational safety and security as well as security and trustworthiness of any associated financial transactions.

33 ADVANCED PROPULSION SYSTEMS↗