Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Nucleon structure studies: DVCS on polarised protons with the CLAS12 experiment, and development of Micromegas detectors for EIC

The quark and gluon structure of nucleons is crucial for understanding the origin of their mass and spin. This information is encoded in structure function such as Generalised Parton Distributions (GPDs), which provide a three-dimensional picture of the nucleon in terms of its constituents. Deeply Virtual Compton Scattering (DVCS) offers the most direct access to GPDs, but their extraction requires high-precision measurements of multiple observables over a wide kinematic range. In 2022 and 2023 the CLAS12 experiment at Jefferson Lab (JLab) collected data from polarised electron scattering on a longitudinally polarised proton target, enabling the first measurement of polarised DVCS asymmetries at JLab 12GeV kinematics. This thesis will present preliminary measurement of the beam, target and double spin DVCS asymmetries from the CLAS12 polarised proton target data. Nucleon structure studies will also constitute a major part of the physics program at the future Electron Ion Collider (EIC). The development of the first detector at the EIC is ongoing and it requires light Micro-Pattern Gaseous Detectors (MPGDs) for its tracking system. This thesis further reports initial tests of Micromegas MPGDs with a two-dimensional readout developed for EIC.

Polcher, Samy [Univ. Paris-Saclay, Gif-sur-Yvette ↗

Very high frequency digital rangine system

Digital ranging system measures slant range /from 500 feet to 200 nautical miles/ and provides digital range readout during range tracking between any two airborne vehicles.

Sobel, S. E.↗

Precision star-tracking telescope

The design, construction, and preliminary testing of a new high accuracy star tracking telescope for the laboratory model of the Stanford gyro relativity experiment are described. The function of the telescope in the final flight experiment is to define (by reference to a suitable star) a direction in space for comparison with the relativistic precession of a group of gyroscopes. The design of the telescope has been strongly affected by designs for other portions of the overall experiments, for example the gyroscopes, the attitude control system of the satellite, and the instrumentation system used in processing relativity data. Main goals for the star tracker are: (1) independent readout of angular position in two planes; (2) absolute null stability over a one year period of mechanical parts; (3) readout linear to 0.001 arc-seconds over + or - 0.05 arc-second; (4) noise performance leading to a resolution of 0.05 arc-second in 0.1 second observation time of the chosen reference star; and (5) provision for automatic gain control capable of matching the gains of the gyroscopes and telescope readouts to 1% or better.

Fairbank, W. M.↗

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

Multiplexed Holographic Data Storage in Bacteriorhodopsin

Biochrome photosensitive films in particular Bacteriorhodopsin exhibit features which make these materials an attractive recording medium for optical data storage and processing. Bacteriorhodopsin films find numerous applications in a wide range of optical data processing applications; however the short-term memory characteristics of BR limits their applications for holographic data storage. The life-time of the BR can be extended using cryogenic temperatures [1], although this method makes the system overly complicated and unstable. Longer life-times can be provided in one modification of BR - the "blue" membrane BR [2], however currently available films are characterized by both low diffraction efficiency and difficulties in providing photoreversible recording. In addition, as a dynamic recording material, the BR requires different wavelengths for recording and reconstructing of optical data in order to prevent the information erasure during its readout. This fact also put constraints on a BR-based Optical Memory, due to information loss in holographic memory systems employing the two-lambda technique for reading-writing thick multiplexed holograms.

Mehrl, David J.↗

Acquisition and tracking performance measurements for a high speed area array detector system

A proof-of-concept (POC) demonstration system has been developed which demonstrates acquisition, tracking and point-ahead angle sensing for a space optical communications terminal utilizing a single high speed area array detector. The detector is the 128 x 128 pixel Kodak HS-40 photodiode array. It has 64 parallel readout channels and can operate at frames rates up to 40,000 frames/sec with rms readout noise of 20 photoelectrons. A windowing scheme and special purpose digital signal processing electronics are employed to implement acquisition and tracking algorithms. The system operates at greater than 1 kHz sample (frame) rates. Acquisition can be performed in as little as 30 milliseconds with less than 1 picowatt of 0.85 micron beacon power on the detector. At the same power level, the rms tracking accuracy is approximately 1/16 pixel. Results of system analysis and measurements using the POC system are presented.

Short, R. C.↗

A prototype detection system for atmospheric monitoring of xenon radioisotopes

The design of a radioxenon detection system utilizing a CdZeTe crystal and a plastic scintillator coupled to an array of SiPMs to conduct beta-gamma coincidence detection for atmospheric radioxenon monitoring, as well as the measurement of 135 Xe and 133/133m Xe, have been detailed previously. This paper presents recent measurements of 133/133m Xe and 131m Xe and the observation of conversion electrons in their coincidence spectra, as well as a 48-hour background measurement to calculate the Minimum Detectable Concentration (MDC) of radioxenon isotopes in the system. The identification of Regions of Interest (ROIs) in the coincidence spectra yielded from the radioxenon measurements, and the subsequent calculation of the MDCs of the system for 135 Xe, 133/133m Xe, and 131m Xe, are also discussed. Calculated MDCs show that the detection system preforms respectably when compared to other state of the art radioxenon detection systems and achieved an MDC of less than 1 mBq/m 3 for 131m Xe, 133 Xe, and 133m Xe, in accordance with limits set by the Comprehensive Nuclear-Test-Ban Treaty (CTBTO). Lastly, the system also provides the advantage of room temperature operation, compactness, low noise operation and having simple readout electronics.

36 MATERIALS SCIENCE↗

MCP-PMT development at Argonne for particle identification

The proposed high-energy high-luminosity polarized Electron-Ion Collider (EIC) demands excellent particle identification over a wide range of particles momenta to achieve the best separation between signal and background particles. Various Cherenkov imaging detector sub-systems are being considered in EIC detector concepts for hadron identification for particles momenta up to 50 GeV/c. One important challenge in this case is to provide a reliable highly pixelated photosensor working in the high radiation and high magnetic field environment. The recently commercialized Large Area Picosecond Photo-Detector (LAPPD) provides a promising low-cost photosensor solution for the various EIC Cherenkov imaging sub-systems. Optimization of the phtosensor design for high magnetic field tolerance, precision timing resolution, and pixelated readout was performed at Argonne National Laboratory with 6 x 6 cm(2) microchannel plate photomultipliers. The techniques and optimized design parameters would be transferrable to industrial partners for low-cost LAPPD production to achieve the demonstrated performance.

atomic layer deposition↗

ALICE-USA Barrel Tracking Upgrade (Project Final Report)

The ALICE-USA Barrel Tracking Upgrade (BTU) project began in 2015 to participate in a major upgrade of the Time Projection Chamber (TPC) and the Inner Tracking System (ITS) of the ALICE Experiment at CERN in Geneva, Switzerland. This upgrade increased the maximum readout rate of the ALICE detector to accommodate the increased heavy ion interaction rates following Long Shutdown 2 of the Large Hadron Collider, and greatly improved the vertexing performance of the detector. The original scope was completed and reviewed in November 2019. The BTU project document BTU.19.v1 "ALICE Barrel Tracking Upgrade Project Closeout / Transition to Operations (2019)" from November 2019 describes the status in detail and is attached as Appendix 1 below. At that point, all delivery milestones had been met on time, all Key Performance Parameters (KPPs) of the project had been satisfied, and the project was under budget. Several subsequent No Cost Extensions (NCEs) supported integration and pre-commissioning of the BTU project deliverables at CERN, as well as study and assessment of performance with Pb-Pb collisions at 50 kHz. The BTU project was successfully completed on 30 September 2024.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bolometric detector systems for IR and mm-wave space astronomy

Recent developments in bolometric detector systems for millimeter and submillimeter wave space astronomy are described. Current technologies meet all the requirements for the high frequency instrument onboard the cosmic background radiation anisotropy satellite/satellite for the measurement of background anisotropies (COBRAS/SAMBA) platform. It is considered that the technologies that are currently being developed will significantly reduce the effective time constant and/or the cooling requirements of bolometric detectors. These technologies lend themselves to the fabrication of the large format arrays required for the Far Infrared and Submillimeter Space Telescope (FIRST). The scientific goals and detector requirements of the COBRAS/SAMBA platform that will use infrared bolometers are reviewed and the baseline detector system is described, including the feed optics, the infrared filters, the cold amplifiers and the warm readout electronics.

Church, S. E.↗

Reducing Stray Light To Characterize Nirspec Subsystems: The Focal Plane Array And Micro-Shutter Array

The James Webb Space Telescope (JWST) is an infrared, space-based telescope scheduled for launch in 2013. JWST includes four scientific instruments, including the Near Infrared Spectrometer (NIRSpec), which operates in the wavelength range from 0.6 to 5 microns. NASA/Goddard Space Flight Center (GSFC) is responsible for two NIRSpec subsystems: the detector subsystem, with its focal plane array (FPA), and the micro-shutter subsystem, with its micro-shutter array (MSA). The FPA is comprised of two side-by-side Rockwell Scientific HgCdTe 2kx2k detectors, with detectors and readout electronics optimized for low noise. The MSA is a GSFC developed micro-electro-mechanical system (MEMS) that serves as a programmable slit mask, allowing NIRSpec to obtain simultaneous spectra of >100 objects in a single field of view. We present the optical characterization test plan of the FPA. The test plan is driven by many requirements: cryogenic operating temperature, a flight-like beam shape, and multi-wavelength photon flux from 1 to 60,000 per second, thus low stray light is critical. We use commercial optical modeling software to predict stray light effects at the FPA. We also present the optical contrast test plan of the MSA. Since each individual shutter element operates in on/off fashion, the most important optical metric is contrast. The MSA structure is designed to minimize stray and scattered light, and the test setup reduces stray light such that the optical contrast requirement is met.

Connelly, Joseph A.↗

High count rate thermal neutron detectors and electronics

Improved, high count rate thermal neutron counters and electronics enabling new, higher measurement capabilities are disclosed. Next generation 3He and 10B tubes may include an electronics package capable of operating at higher count rates and in higher gamma fields and providing more efficient use of 3He gas. Conventional detector systems may also be upgraded, providing a possible solution to measure spent nuclear fuel with high neutron efficiency previously not possible in 235U fission counter systems. Switching the number of tubes per amplifier allows use of the measured nuclear material for a calibration standard for dead time correction, increasing accuracy of neutron measurements systems. An optimized detector geometry and advanced electronics with double pulse filtering and a dual channel readout may be provided. A bipolar shaper may improve dead time, provide efficient detector use, reduce double pulsing, facilitate high count rate measurements, and allow remote threshold setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization and Performance Characterization of the Second Generation Fermilab Constant Fraction Discriminator Readout ASIC

We present the optimization and performance characterization of the second-generation Fermilab Constant Fraction Discriminator ASIC (FCFD), designed for the readout of AC-coupled low-gain avalanche detector (LGAD) strip-sensors. The FCFD is explicitly engineered to be insensitive to signal-amplitude variations, thereby removing the need for time-walk correction that is required in other LGAD time-stamping readout ASICs. This updated version, referred to as FCFD1.1, incorporates several enhancements over the first iteration to address key challenges in AC-coupled LGAD front-end design. We outline the primary readout-ASIC design considerations for these applications, describe the methodology used to evaluate critical sensor and system parameters, and summarize the additionally implemented features. Performance measurements using injected charge signals and minimum-ionizing particles in test-beams demonstrate a time resolution of approximately 40 ps and a position resolution of roughly \SI{15}{\micro\meter} when tested with beam particles uniformly over the active area of the sensor.

Apresyan, Artur [Fermilab] (ORCID:0000000261860130↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution for the readout while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest or by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

The Zwicky Transient Facility: System Overview, Performance, and First Results

The Zwicky Transient Facility (ZTF) is a new optical time-domain survey that uses the Palomar 48 inch Schmidt telescope. A custom-built wide-field camera provides a 47 deg 2 field of view and 8 s readout time, yielding more than an order of magnitude improvement in survey speed relative to its predecessor survey, the Palomar Transient Factory. We describe the design and implementation of the camera and observing system. The ZTF data system at the Infrared Processing and Analysis Center provides near-real-time reduction to identify moving and varying objects. We outline the analysis pipelines, data products, and associated archive. As a result, we present on-sky performance analysis and first scientific results from commissioning and the early survey. ZTF's public alert stream will serve as a useful precursor for that of the Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

The Zwicky Transient Facility: System Overview, Performance, and First Results

The Zwicky Transient Facility (ZTF) is a new optical time-domain survey that uses the Palomar 48 inch Schmidt telescope. A custom-built wide-field camera provides a 47 deg ^(2) field of view and 8 s readout time, yielding more than an order of magnitude improvement in survey speed relative to its predecessor survey, the Palomar Transient Factory. We describe the design and implementation of the camera and observing system. The ZTF data system at the Infrared Processing and Analysis Center provides near-real-time reduction to identify moving and varying objects. We outline the analysis pipelines, data products, and associated archive. Finally, we present on-sky performance analysis and first scientific results from commissioning and the early survey. ZTF’s public alert stream will serve as a useful precursor for that of the Large Synoptic Survey Telescope.

Eric C. Bellm↗

Use of Photoelastic Modulators for High-accuracy Spectropolarimetric Imaging of Aerosols

Passive multiangular, multispectral, and polarimetric sensing approaches each have unique strengths for the measurement of tropospheric aerosol column abundances and microphysical properties. Current spaceborne multispectral and multiangular aerosols sensors operate at approximately 1 km resolution. Under NASA's Instrument Incubator Program, we are developing an electro-optic imaging approach that will enable adding high-accuracy polarimetry to such observations. To achieve a degree of linear polarization (DOLP) uncertainty of 0.5%, our approach temporally modulates the linear-polarization component of incoming light at a rapid rate, enabling each detector within a focal-plane array, combined with polarization analyzers, to measure the relative proportions of the linear Stokes components Q or U to the total intensity. Our system uses tandem photoelastic modulators (PEMs) within a high-reflectance, low diattenuation camera design. The two PEMs vibrate at slightly different resonant frequencies, leading to modulation of the polarized light at a heterodyne frequency of ~25 Hz. High-speed (1 kHz) readout of the detector arrays samples the output waveforms from which Q/I and U/I are derived. We report on experimental and theoretical analyses of PEM and optical system performance, along with plans for developing ruggedized PEMs capable of withstanding launch and on-orbit stresses.

photoelastics↗