Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Evaluation of biliary anatomy in the caudate lobe using drip infusion cholangiography-computed tomography

Purpose: This study aimed to retrospectively evaluate the caudate branches (CBs), which are bile ducts originating from the caudate lobe (CL), using drip infusion cholangiography with computed tomography (DIC-CT). Methods: The confluence patterns of CBs were evaluated in 185 adult patients undergoing DIC-CT. The following bile duct features were evaluated: (a) number of depicted CBs; (b) identification of the caudate portion from which the CBs were derived; (c) identification of the confluence site of a CB; and (d) whether there was a difference in the confluence site of the CBs depending on the position of the right posterior hepatic duct (RPHD) and the portal vein (PV). Results: DIC-CT enabled detection of a total of 640 bile ducts from the CL in 185 patients, and the total number of CBs from the Spiegel lobe (SP), the paracaval portion, and the caudate process (CP) were 347 (54.2%), 112 (17.5%), and 181 (28.2%), respectively. In the SP, over 60% of CBs joined the left hepatic duct system (LHDS). The positional relationship between the RPHD and the PV was divided into a supra-portal course (n = 168) and an infra-portal course (n = 17). The number of CBs joining the LHDS was significantly different between a supra-portal course and an infra-portal course (p = 0.0484). Conclusion: CBs were depicted by DIC-CT in 98.9% of the subjects, and a detailed evaluation was possible. The number of CBs joining the LHDS was associated with the position of the RPHD and the PV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-159: Analysis of Total Imaging Uncertainty in Respiratory-Gated Radiotherapy

Purpose: In respiratory-gated radiotherapy, the gating phase during treatment delivery needs to coincide with the corresponding phase determined during the treatment plan. However, because radiotherapy is performed based on the image obtained for the treatment plan, the time delay, motion artifact, volume effect, and resolution in the images are uncertain. Thus, imaging uncertainty is the most basic factor that affects the localization accuracy. Therefore, these uncertainties should be analyzed. This study aims to analyze the total imaging uncertainty in respiratory-gated radiotherapy. Methods: Two factors of imaging uncertainties related to respiratory-gated radiotherapy were analyzed. First, CT image was used to determine the target volume and 4D treatment planning for the Varian Realtime Position Management (RPM) system. Second, an X-ray image was acquired for image-guided radiotherapy (IGRT) for the BrainLAB ExacTrac system. These factors were measured using a respiratory gating phantom. The conditions applied during phantom operation were as follows: respiratory wave form, sine curve; respiratory cycle, 4 s; phantom target motion amplitude, 10, 20, and 29 mm (which is maximum phantom longitudinal motion). The target and cylindrical marker implanted in the phantom coverage of the CT images was measured and compared with the theoretically calculated coverage from the phantom motion. The theoretical position of the cylindrical marker implanted in the phantom was compared with that acquired from the X-ray image. The total imaging uncertainty was analyzed from these two factors. Results: In the CT image, the uncertainty between the target and cylindrical marker’s actual coverage and the coverage of CT images was 1.19 mm and 2.50mm, respectively. In the Xray image, the uncertainty was 0.39 mm. The total imaging uncertainty from the two factors was 1.62mm. Conclusion: The total imaging uncertainty in respiratory-gated radiotherapy was clinically acceptable. However, an internal margin should be added to account for the total imaging uncertainty.

60 APPLIED LIFE SCIENCES↗

Evidence for supernova injection into the solar nebula and the decoupling of r-process nucleosynthesis

The isotopic composition of our Solar System reflects the blending of materials derived from numerous past nucleosynthetic events, each characterized by a distinct isotopic signature. We show that the isotopic compositions of elements spanning a large mass range in the earliest formed solids in our Solar System, calcium–aluminum-rich inclusions (CAIs), are uniform, and yet distinct from the average Solar System composition. Relative to younger objects in the Solar System, CAIs contain positive r-process anomalies in isotopes A < 140 and negative r-process anomalies in isotopes A > 140. This fundamental difference in the isotopic character of CAIs around mass 140 necessitates (i) the existence of multiple sources for r-process nucleosynthesis and (ii) the injection of supernova material into a reservoir untapped by CAIs. A scenario of late supernova injection into the protoplanetary disk is consistent with formation of our Solar System in an active star-forming region of the galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The impact of stacking and phonon environment on energy transfer in organic chromophores: computational insights

Energy transfer in organic materials is extensively studied due to many applications in optoelectronics. The electronic and vibrational relaxations within molecular assemblies can be influenced by stacking arrangements or additions of a backbone that unites them. Here, we present the computational study of the photoexcitation dynamics of a perylene diimide monomer, and face-to-face stacked dimer and trimer. By using non-Energy transfer in organic materials is extensively studied due to many applications in optoelectronics. The electronic and vibrational relaxations within molecular assemblies can be influenced by stacking arrangements or additions of a backbone that unites them. In this work, we present the computational study of the photoexcitation dynamics of a perylene diimide monomer, and face-to-face stacked dimer and trimer. By using non-adiabatic excited-state molecular dynamics simulations, we show that the non-radiative relaxation is accelerated with the number of stacked molecules. This effect is explained by differences in the energy splitting between states that impacts their corresponding nonadiabatic couplings. Additionally, our analysis of the vibronic dynamics reveals that the passage through the different conical intersections that participate in the relaxation of the stacked systems, activate a positive feedback mechanism. This effect involves a narrow set of vibrational normal modes that accelerate the process by increasing the efficiency of its vibronic dynamics. In contrast, an addition of a biologically inspired backbone slows down the relaxation rate due to its participation in the vibronic dynamics of the molecular stacking arrangements. Our results suggest the stacking arrangements and common backbones as strategies to modulate the efficiency of electronic and vibrational relaxation of diimide-based systems and other molecular aggregates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Blackcomb2: Hardware-Software Co-design for Nonvolatile Memory in Exascale Systems

The impending shift from DRAM and Flash to fast nonvolatile memory (NVM) provides a game-changing opportunity to rethink traditional system architectures; to address their energy inefficiencies; to leverage the new devices for greater performance; and to exploit the new capability of nonvolatility to enhance system resilience, even in the face of larger system scale and degraded reliability of components. Building on the accomplishments of the Blackcomb Project, funded in 2010, we propose to identify, evaluate, and optimize the most promising NVM hardware and software technologies, which are essential to provide the necessary memory capacity, performance, resilience, and energy efficiency in exascale systems. Capacity and energy are the key drivers. Today's pressing application requirements mandate exascale computing; the datasets and concurrency of these applications demand memory capacity that cannot be met by traditional memory technologies. Although charge-based DRAM will endure, experts foresee only modest DRAM capacity gains. And, as moving data between levels of the hierarchy, and storing and accessing data on disk consumes significant energy, a more energy efficient solution is required. We, therefore, posit that exascale systems will need high density, energy-efficient storage technologies, such as nonvolatile memory for access, transformation, and management of exascale data. To address these issues, in this renewal request, we propose continue the work of our vertically- integrated, focussed team, where our co-design is informed by proxies and interactions with DOE co-design centers. In software, we start by assuming that nonvolatility requires new abstractions and new infrastructure, allowing persistent objects, and delivering performance gains for _le systems and robustness through fast checkpointing. In architecture, we evaluate the tradeoffs of performance and energy by employing a scalable and accurate simulation system to analyze realistic proxy applications. Through this co-design process, we rethink the whole memory architecture, from the cell to the array to the device, with ECC, wearout management, and interfaces. Finally, we provide open-source software models of these NVM-based memory systems.

97 MATHEMATICS AND COMPUTING↗

Battery system including batteries that have a plurality of positive terminals and a plurality of negative terminals

A lithium battery for use in a vehicle includes a container, a plurality of positive terminals extending from a first end of the lithium battery, and a plurality of negative terminals extending from a second end of the lithium battery. The plurality of positive terminals are provided in a first configuration and the plurality of negative terminals are provided in a second configuration, the first configuration differing from the second configuration. A battery system for use in a vehicle may include a plurality of electrically connected lithium cells or batteries.

25 ENERGY STORAGE↗

A nuclear-hydrogen hybrid energy system with large-scale storage: A study in optimal dispatch and economic performance in a real-world market

Here a study in optimal dispatch and economic analysis of a novel nuclear hybrid energy system (NHES) with large-scale hydrogen storage and a novel control scheme is conducted. The control scheme makes charge and discharge decisions by using the real-time electricity price relative to the historical price distribution. The pricing data is taken from the ERCOT Houston and West load zones with different price oscillations. Six case control studies with different levels of aggressiveness were chosen for each load zone for a total of 12 case studies. It is found that in a high price volatility load zone, a more aggressive control strategy maximizes revenue, while in a less oscillatory load zone, a moderate control strategy performs better. The NHES can store energy when the price is low and sell additional electricity when the price is high, as well as participate in the ancillary services market. Due to these advantages, the NHES can generate 10–40 million USD more revenue annually than a stand-alone nuclear plant. Due to higher costs, the NHES has a higher LCOE (81.36 USD/MWh) than a stand-alone plant (68.66 USD/MWh); however, the LCOE of the NHES is still comparable to other new forms of electricity generation. It is found that both the NHES and the stand-alone plant are not economical in the existing electricity market. Due to the extra revenue generated, the hybrid system has a positive annual cashflow whereas the stand-alone plant does not. It is found that the hybrid plant needs less cost subsidy than a stand-alone plant to become economical.

08 HYDROGEN↗

Spatial and rotational quality assurance of 6DOF patient tracking systems

Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations. In this work, the authors develop a novel technique to evaluate the 6 degree of freedom 6(DOF) (translations and rotations) performance of external motion tracking systems. The authors apply this methodology to an infrared marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to perform motions with sub-millimeter and subdegree accuracy in a 6DOF workspace. An infrared marker tracking system was first used to validate a calibration algorithm which associates the motion phantom coordinate frame to the camera frame. The 6DOF positions of the mobile robotic system in this space were then tracked and recorded independently by an optical surface tracking system after a cranial phantom was rigidly fixed to the moveable platform of the robotic stage. The calibration methodology was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20 × 20 × 16 mm and 5° × 5° × 5° workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the infrared (IR) marker tracking system to have maximal root-mean square error (RMSE) values of 0.18, 0.25, 0.07 mm, 0.05°, 0.05°, and 0.09° in left–right (LR), superior–inferior (SI), anterior–posterior (AP), pitch, roll, and yaw, respectively, comparing the intended 6DOF position and the measured position by the IR camera. Similarly, the 6DOF RSME discrepancy for the HD optical surface tracker yielded maximal values of 0.46, 0.60, 0.54 mm, 0.06°, 0.11°, and 0.08° in LR, SI, AP, pitch, roll, and yaw, respectively, over the same 6DOF evaluative workspace. An earlier generation 3D optical surface tracking unit was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.69, 0.74, 0.47 mm, 0.28°, 0.19°, and 0.18°, in LR, SI, AP, pitch, roll, and yaw, respectively, in the same 6DOF evaluation space. Conclusions: The proposed technique was found to be effective at evaluating the performance of 6DOF patient tracking systems. All observed optical tracking systems were found to exhibit tracking capabilities at the sub-millimeter and subdegree level within a 6DOF workspace.

60 APPLIED LIFE SCIENCES↗

Improvement of Digital Filter for the FNAL Booster Transverse Dampers

Fermilab Booster has two transverse dampers which independently suppress beam instabilities in the horizontal and vertical planes. A suppression of the common mode signal is achieved by digital notch filter which is based on subtracting beam positions for two consecutive turns. Such system operates well if the orbit position changes sufficiently slow. Unfortunately it is not the case for FNAL Booster where the entire accelerating cycle consists of about 20000 turns, and successful transition crossing requires the orbit drifts up to about 10 μm/turn, resulting in excessive power, power amplifier saturation and loss of stability. To suppress this effect we suggest an improvement of the digital filter which can take into account fast orbit changes by using bunch positions of a few previous turns. To take into account the orbit change up toN-th order polynomial in time the system requires (N + 3) turns of “prehistory”. In the case of sufficiently small gain the damping rate and the optimal digital filter coefficients are obtained analytically. Numerical simulations verify analytical theory for the small gain and predict a system performance with gain increase.

43 PARTICLE ACCELERATORS↗

Scalable Metadata Management for a Large Multi-Source Seismic Data Repository

In this work, we implemented the key metadata management components of a scalable seismic data ingestion framework to address limitations in our existing system, and to position it for anticipated growth in volume and complexity. We began the effort with an assessment of open source data flow tools from the Hadoop ecosystem. We then began the construction of a layered architecture that is specifically designed to address many of the scalability and data quality issues we experience with our current pipeline. This included implementing basic functionality in each of the layers, such as establishing a data lake, designing a unified metadata schema, tracking provenance, and calculating data quality metrics. Our original intent was to test and validate the new ingestion framework with data from a large-scale field deployment in a temporary network. This delivered somewhat unsatisfying results, since the new system immediately identified fatal flaws in the data relatively early in the pipeline. Although this is a correct result it did not allow us to sufficiently exercise the whole framework. We then widened our scope to process all available metadata from over a dozen online seismic data sources to further test the implementation and validate the design. This experiment also uncovered a higher than expected frequency of certain types of metadata issues that challenged us to further tune our data management strategy to handle them. Our result from this project is a greatly improved understanding of real world data issues, a validated design, and prototype implementations of major components of an eventual production framework. This successfully forms the basis of future development for the Geophysical Monitoring Program data pipeline, which is a critical asset supporting multiple programs. It also positions us very well to deliver valuable metadata management expertise to our sponsors, and has already resulted in an NNSA Office of Defense Nuclear Nonproliferation commitment to a multi-year project for follow-on work.

58 GEOSCIENCES↗

Generalizing the Tomboulis-Yaffe inequality to SU(N) lattice gauge theories and general classical spin systems

We extend the inequality of Tomboulis and Yaffe in SU(2) lattice gauge theory (LGT) to SU(N) LGT and to general classical spin systems, by use of reflection positivity. Basically the inequalities guarantee that a system in a box that is sufficiently insensitive to boundary conditions has a non-zero mass gap. We explicitly illustrate the theorem in some solvable models. Strong-coupling expansion is then utilized to discuss some aspects of the theorem. Finally, a conjecture for exact expression to the off-axis mass gap of the triangular Ising model is presented. The validity of the conjecture is tested in multiple ways.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated ultrasonic particle positioning and low excitation light fluorescence imaging

A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling and analysis of an AMB system with flexible rotor in HTR-10GT - 18550

Active magnetic bearing (AMB) has been widely used in high-temperature gas-cooled reactor (HTR) for its specific properties: free of contact, absence of lubrication, capability of rotating at high speed. AMB system is inherently unstable since positive feedback exists in the open loop system and, thus, requires feedback control. From the control view of point, accurate system model is essential for designing of an effective controller especially when the flexible gyroscopic rotor is involved. In the paper, a flexible rotor and an open-loop AMB system model were established for the purpose of controller design. Dynamic characteristics of the undamped flexible rotor are analyzed including modal vibration analysis and undamped natural frequencies. Additionally, some characteristics of open-loop AMB system are investigated such as relationship between support stiffness and natural frequencies, and the system frequency response. The analysis results in this paper will provide valuable information for AMB system feedback controller design. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features

Purpose: The purpose of this study was to develop a novel algorithm to create a robust internal respiratory signal (IRS) for retrospective sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm combines information from the Fourier transform of the CT images and from internal anatomical features to form the IRS. The algorithm first extracts potential respiratory signals from low-frequency components in the Fourier space and selected anatomical features in the image space. A clustering algorithm then constructs groups of potential respiratory signals with similar temporal oscillation patterns. The clustered group with the largest number of similar signals is chosen to form the final IRS. To evaluate the performance of the proposed algorithm, the IRS was computed and compared with the external respiratory signal from the real-time position management (RPM) system on 80 patients. Results: In 72 (90%) of the 4D CT data sets tested, the IRS computed by the authors’ proposed algorithm matched with the RPM signal based on their normalized cross correlation. For these data sets with matching respiratory signals, the average difference between the end inspiration times (Δt{sub ins}) in the IRS and RPM signal was 0.11 s, and only 2.1% of Δt{sub ins} were more than 0.5 s apart. In the eight (10%) 4D CT data sets in which the IRS and the RPM signal did not match, the average Δt{sub ins} was 0.73 s in the nonmatching couch positions, and 35.4% of them had a Δt{sub ins} greater than 0.5 s. At couch positions in which IRS did not match the RPM signal, a correlation-based metric indicated poorer matching of neighboring couch positions in the RPM-sorted images. This implied that, when IRS did not match the RPM signal, the images sorted using the IRS showed fewer artifacts than the clinical images sorted using the RPM signal. Conclusions: The authors’ proposed algorithm can generate robust IRSs that can be used for retrospective sorting of 4D CT data. The algorithm is completely automatic and requires very little processing time. The algorithm is cost efficient and can be easily adopted for everyday clinical use.

60 APPLIED LIFE SCIENCES↗

Systems for increasing the sensitivity of gamma-ray imagers

Systems that increase the position resolution and granularity of double sided segmented semiconductor detectors are provided. These systems increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.

47 OTHER INSTRUMENTATION↗

SU-E-J-259: Quantification of Rotational Localization Offset in Radiation Therapy

Purpose: To verify the necessity of 6D localization detection and correction in radiation therapy. Methods: An anthropomorphic head and neck phantom was used to test the BrainLab ExacTrac x-ray imaging system. After initial positioning, both ExacTrac and the on-board kV CBCT were used to detect the offset at the same position, using both manual and automatic registration algorithms. Then 6D offset including rotational errors up to 5 degree were introduced. Both ExacTrac and CBCT were used to correct the offsets and the residual errors were evaluated. Finally, 6D offset detected by ExacTrac for a C-Spine patient was reported. Results: The differences in 3D offset detected by ExacTrac and CBCT were 1.5 ± 1.2(Lateral), 2.7 ± 2.7(Vertical), and 4.0 ± 6.3(longitudinal) mm with manual registration while the corresponding differences decreased to 0.6 ± 0.3, 1.0 ± 0.3, and 0.3 ± 0.3 when automatic registration were used. CBCT corrected the translational offset to within 0.5 mm but the rotational errors remained and detected by the ExacTrac system (Yaw=2.1, Roll=1.1, Pitch=1.4 degree). When similar offset was introduced and corrected using ExacTrac, the residual error detected by both CBCT and ExacTrac were within 0.5 mm / 0.5 degree. The average offset from the 112 ExacTrac x-ray corrections for the C-Spine patient was 0.6 ± 1.6 (lateral), 5.4 ± 8(vertical), 1.6±1.1(longitudinal) mm, and 0.7 ± 0.6 (pitch), 0.7 ± 0.4(roll), 1.2 ± 0.7 (yaw) degree. Larger rotational errors, with a maximum of 2.7 degree (corresponds to about 1.5 to 4.5 mm offset for a POI 10 to 30 cm away from the isocenter), were observed when couch rotational were involved. Conclusion: Rotational errors are common in patient localization, especially when couch rotation is involved. Both appropriate imaging system and 6D robotic couch are necessary to detect and correct the rotational localization errors.

60 APPLIED LIFE SCIENCES↗

Ion-acoustic Gardner solitons in a four-component nonextensive multi-ion plasma

The nonlinear propagation of ion-acoustic (IA) solitary waves (SWs) in a four-component non-extensive multi-ion plasma system containing inertial positively charged light ions, negatively charged heavy ions, as well as noninertial nonextensive electrons and positrons has been theoretically investigated. The reductive perturbation method has been employed to derive the nonlinear equations, namely, Korteweg−deVries (KdV), modified KdV (mKdV), and Gardner equations. The basic features (viz. polarity, amplitude, width, etc.) of Gardner solitons are found to exist beyond the KdV limit and these IA Gardner solitons are qualitatively different from the KdV and mKdV solitons. It is observed that the basic features of IA SWs are modified by various plasma parameters (viz. electron and positron nonextensivity, electron number density to ion number density, and electron temperature to positron temperature, etc.) of the considered plasma system. The results obtained from this theoretical investigation may be useful in understanding the basic features of IA SWs propagating in both space and laboratory plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗