Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portable Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

P4: Portable Parallel Processing Pipelines for Interactive Information Visualization

We present P4, an information visualization toolkit that combines declarative design specification and GPU computing for building high-performance interactive systems. Most of the existing information visualization toolkits do not harness the power of parallel processors in today's mainstream computers. P4 leverages GPU computing to accelerate both data processing and visualization rendering for interactive visualization applications. P4's programming interface offers a declarative visualization grammar for rapid specifications of data transformations, visual encodings, and interactions. By simplifying the development of GPU-accelerated visualization systems while supporting a high degree of flexibility and customization for design specification, P4 narrows the gap between expressiveness and scalability in information visualization toolkits. Through a range of examples and benchmark tests, we demonstrate that P4 provides high efficiency for creating interactive visualizations and offers drastic performance improvement over current state-of-the-art toolkits.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation of Fast Microfluidic Thermal Lysis of Bacteria for Diagnostic Sample Preparation

Development of new diagnostic platforms that incorporate lab-on-a-chip technologies for portable assays is driving the need for rapid, simple, low cost methods to prepare samples for downstream processing or detection. An important component of the sample preparation process is cell lysis. In this work, a simple microfluidic thermal lysis device is used to quickly release intracellular nucleic acids and proteins without the need for additional reagents or beads used in traditional chemical or mechanical methods (e.g., chaotropic salts or bead beating). On-chip lysis is demonstrated in a multi-turn serpentine microchannel with external temperature control via an attached resistive heater. Lysis was confirmed for Escherichia coli by fluorescent viability assay, release of ATP measured with bioluminescent assay, release of DNA measured by fluorometry and qPCR, as well as bacterial culture. Results comparable to standard lysis techniques were achievable at temperatures greater than 65 °C and heating durations between 1 and 60 s.

lab-on-a-chip↗

Machine learning assisted modeling of mixing timescale for LES/PDF of high-Karlovitz turbulent premixed combustion

Accurate modeling of mixing in the transported probability density function (PDF) method remains a great challenge, especially for turbulent premixed combustion under extreme conditions such as high Karlovitz number Ka. Recently, a power-law based mixing timescale model was developed for the large-eddy simulations (LES)/PDF modeling of high-Ka number turbulent premixed flames. It is found in this work that the power-law mixing timescale model is highly sensitive to the model parameters. It is thus critically needed to develop accurate calibration of these model parameters. The empirical specification of the model parameters developed in Zhang et. al. is found to be inadequate for accurate modeling of the mixing timescale. Here, machine learning is introduced as an attractive alternative in this work for the specification of the model parameters. A high-Ka number DNS jet flame is used as the training and validation of the machine learning models. The choices of the input parameters are discussed and compared for the machine learning models. The effect of differential molecular diffusion on mixing is examined by including the effect of the Lewis number in the training of the machine learning models. The performance of different machine learning algorithms is compared for the specification of the mixing model parameters. Overall, excellent performance of the machine learning models is observed for assisting the mixing modeling. The feasibility, interpretability, applicability, generality, and portability of using machine learning are discussed in general to provide a perspective on applying data-driven machine learning for turbulent combustion modeling studies.

42 ENGINEERING↗

Defect localization, characterization and reliability assessment in emerging photovoltaic devices.

Microsystems-enabled photovoltaics (MEPV) can potentially meet increasing demands for light-weight, portable, photovoltaic solutions with high power density and efficiency. The study in this report examines failure analysis techniques to perform defect localization and evaluate MEPV modules. CMOS failure analysis techniques, including electroluminescence, light-induced voltage alteration, thermally-induced voltage alteration, optical beam induced current, and Seabeck effect imaging were successfully adapted to characterize MEPV modules. The relative advantages of each approach are reported. In addition, the effects of exposure to reverse bias and light stress are explored. MEPV was found to have good resistance to both kinds of stressors. The results form a basis for further development of failure analysis techniques for MEPVs of different materials systems or multijunction MEPVs. The incorporation of additional stress factors could be used to develop a reliability model to generate lifetime predictions for MEPVs as well as uncover opportunities for future design improvements.

14 SOLAR ENERGY↗

Next Generation Wind Turbine

The goal of this collaborative effort between Western New England University's College of Engineering and FloDesign Wind Turbine (FDWT) Corporation to wok on a novel areodynamic concept that could potentially lead to the next generation of wind turbines. Analytical studies and early scale model tests of FDWT's Mixer/Ejector Wind Turbine (MEWT) concept, which exploits jet-age advanced fluid dynamics, indicate that the concept has the potential to significantly reduce the cost of electricity over conventional Horizontal Axis Wind Turbines while reducing land usage. This project involved the design, fabrication, and wind tunnel testing of components of MEWT to provide the research and engineering data necessary to validate the design iterations and optimize system performance. Based on these tests, a scale model prototype called Briza was designed, fabricated, installed and tested on a portable tower to investigate and improve the design system in real world conditions. The results of these scale prototype efforts were very promising and have contributed significantly to FDWT's ongoing development of a product scale wind turbine for deployment in multiple locations around the U.S. This research was mutually beneficial to Western New England University, FDWT, and the DOE by utilizing over 30 student interns and a number of faculty in all efforts. It brought real-world wind turbine experience into the classroom to further enhance the Green Engineering Program at WNEU. It also provided on-the-job training to many students, improving their future employment opportunities, while also providing valuable information to further advance FDWT's mixer-ejector wind turbine technology, creating opportunities for future project innovation and job creation.

17 WIND ENERGY↗

PAIN Schubert Review: Experiment [Slides]

These slides detail the experimental section of the PAIN Schubert Review. The PAIN project is investigating the utility of portable neutron radiography for emergency response. Further sections give an overview of the PAIN project and detail the simulation performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NexusHaus: Solar Decathlon House

The University of Texas at Austin and The Technical University of Munich 2015 Solar Decathlon house is called Nexushaus because it combines UT Austin and TUM students in an affordable modular residential green building in the context of Austin, Texas, based on shape forming principles found in nature that demonstrates transformative technologies in Zero Net Energy, Zero Net Water and Carbon Neutrality. To meet the needs of the competition, a portable modular design has been developed with an assembly that enables ease of installation and both quantitative and qualitative performance in the design. The prefabricated house sits lightly on the land and forms the superstructure for photovoltaic technologies, rainwater collection, aquaculture and permaculture gardening and indoor/outdoor living. The ultimate goal of Nexushaus is to serve as a potential prototype for a next-generation modular home that could be reproduced in mass in an assembly plant in Austin.

solar decathlon, zero net energy, zero net water, ↗

HodDB: Design and Analysis of a Query Processor for Brick.

Brick is a recently proposed metadata schema and ontology for describing building components and the relationships between them. It represents buildings as directed labeled graphs using the RDF data model. Using the SPARQL query language, building-agnostic applications query a Brick graph to discover the set of resources and relationships they require to operate. Latency-sensitive applications, such as user interfaces, demand response and modelpredictive control, require fast queries — conventionally less than 100ms. We benchmark a set of popular open-source and commercial SPARQL databases against three real Brick models using seven application queries and find that none of them meet this performance target. This lack of performance can be attributed to design decisions that optimize for queries over large graphs consisting of billions of triples, but give poor spatial locality and join performance on the small dense graphs typical of Brick. We present the design and evaluation of HodDB, a RDF/SPARQL database for Brick built over a node-based index structure. HodDB performs Brick queries 3-700x faster than leading SPARQL databases and consistently meets the 100ms threshold, enabling the portability of important latency-sensitive building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of In-Situation Radioactivity Inspection System for Food Materials

The impacts on the ocean of releases of radionuclides from the Fukushima nuclear power plants remain unclear. Korean people worry about radioactive contamination of Japanese and Korean sea products. Radioactive contamination of processed foodstuffs, livestock, sea products, farm products imported from Japan and fishes caught in coastal oceans of Korea has become an important social issue. Recently, there are also needs of inspection system for monitoring of public meals such like school feedings of kindergarten, elementary/middle/high school and university. Radioactivity inspections of food materials have been executed manually with portable measuring instruments or at labs using their samples. But, it's very important the radioactivity inspection should be performed at the field of feeding facilities. To protect the health of people from radioactivity contained in Japanese marine products imported to Korea, a system to inspect radioactivity in real time has been developed. The system is to measure the radioactivity level of farm and marine products and public meals continuously and automatically at inspection sites of an agency checking radiation of imported foodstuffs or school. The performance test of NaI(Tl) detector was examined using the quantified Cs-137 source 10 Bq/kg, 30 Bq/kg, 50 Bq/kg, 300 Bq/kg and 900 Bq/kg at Korea Research Institute of Standards and Science(KRISS). Source was put in a box and radioactivity was measured in the middle of the box. First of all, Background was measured and calibration was performed using the Cs-137 300 Bq and Ba-133 3700 Bq for 60 minutes. After setting the background and calibration data, tests of the Cs-137 10, 30, 50, 300, 900 Bq/kg were executed for 10 minutes. A peak-shaped graph is shown at the location of 662 KeV (80∼100 channel). This is due to the gamma radiation energy with 662 KeV emitted by the Cs-137. Because through KRISS examination, the MDA (minimum detectable activity) is about 23 Bq/kg, it is reasonable Cs-137 10 Bq/kg cannot be measured. And in cases of Cs-137 300 Bq/kg and 900 Bq/kg, there are some peak movement on the graph. It can be adjusted by controlling gain or high voltage. The examination was identified through the performance test (Cs-137 10, 30, 50, 300, 900 Bq/kg) at KRISS. In order to increase the measurement efficiency of Cs-137 and the system performance, database will be built up based on radioactivity measurement results from 10 to 300 Bq/kg with the unit 10. Thus, Cs-137 concentration of food materials can be identified below the maximum permissible concentration of 100 Bq/kg on a basis of the spectrum characteristic of Cs-137. Also, anxiety about radioactive contamination of foods after the Fukushima nuclear accident will be eased and trust of the radioactive inspection is expected definitely. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-FG-209-04: Testing of Digital Image Receptors Using AAPM TG-150’s Draft Recommendations - Investigating the Impact of Different Processing Parameters

Purpose: To evaluate implementation of AAPM TG-150’s draft recommendations via a parameter study for testing the performance of digital image receptors. Methods: Flat field images were acquired from 9 calibrated digital image receptors associated with 9 new portable digital radiography systems (Carestream Health, Inc.) based on the draft recommendations and manufacturer-specified calibration conditions (set of 4 images at input detector air kerma ranging from 1 to 25 µGy). Effects of exposure response function (linearized and logarithmic), ‘Presentation Intent Type’ (‘For Processing’ and ‘For Presentation’), detector orientation with respect to the anode-cathode axis (4 orientations; 900 rotations per iteration), different ROI sizes (5×5–40×40 mm{sup 2}) and elimination of varying dimensions of image border (0 mm i.e., without boundary elimination to 150 mm) on signal, noise, signal-to-noise ratio (SNR) and the associated nonuniformities were evaluated. Images were analyzed in Matlab and quantities were compared using ANOVA. Results: Signal, noise and SNR values averaged over 9 systems with default parameter values in draft recommendations were 4837.2±139.4, 19.7±0.9 and 246.4±10.1 (mean ± standard deviation), respectively (at input detector air kerma: 12.5 µGy). Signal, noise and SNR showed characteristic dependency on exposure response function and on ‘Presentation Intent Type’. These values were not affected by ROI size and detector orientation, but analysis showed that eliminating the edge pixels along the boundary was required for the noise parameter (coefficient of variation range for noise: 72%–106% and 3%–4% without and with boundary elimination; respectively). Local and global nonuniformities showed a similar dependence on the need for boundary elimination. Interestingly, computed non-uniformities showed agreement with manufacturer-reported values except for noise non-uniformities in two units; artifacts were seen in images from these two units highlighting the importance of independent evaluations. Conclusion: The effect of different parameters on performance characterization of digital image receptors was evaluated based on TG-150’s draft recommendations.

60 APPLIED LIFE SCIENCES↗

Development of a Portable Training Tool for Simulating Visceral Angiographic Procedures for Beginners

The purpose of this study was to evaluate the usefulness of a tool that we developed to simulate performance of visceral angiography to train beginners in the field of splanchnic angiography. Seven residents and two fellows who were rotating within the Division of Interventional Radiology at our institution between June and August 2008 participated in the evaluation of this tool. They had no experience in performing visceral angiography as an operator. Time for selection of arterial branches arising from the celiac axis on the model was measured before and after training. After such training, the participants performed actual visceral angiography as an operator with instructors beside them. Success of the trainees in selecting visceral arterial branches was evaluated in these real-life cases. In the first test using the model, seven of nine trainees (77.8%) succeeded in selecting all required arteries, while the remaining two failed to select all required arteries. After training using the model, all trainees succeeded in selecting all required arteries just before the actual angiographic study. In the actual angiography, the catheter was successfully inserted from the femoral artery and advanced to the superior mesenteric, celiac, splenic, common hepatic, gastroduodenal, and right and left hepatic arteries by all trainees with only two exceptions. In conclusion, this tool is helpful for training beginners in visceral angiographic procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Testing and Validation Plan for HMS4 Quantitative Gamma Measurements, K-25/K-27 D&D Project, East Tennessee Technology Park, Oak Ridge, Tennessee

The Holdup Measurement System 4 (HMS4) is a portable thallium activated sodium iodide (NaI[Tl]) gamma ray energy spectrometer that, when properly calibrated, is able to make quantifiable assessment of U-235 holdup in the presence of other uranium isotopes and prevailing background radiation. The use and calibration of the HMS4 is based upon the methodologies defined by Russo in La-14206, (Russo 2005), where detection efficiency determination protocols are defined (called Generalized Geometry Holdup [GGH]). The GGH methodology together with attenuation correction algorithms and other modeling parameters are combined in the HMS4 software package to provide a comprehensive tool for conducting in situ gamma-ray measurements. The fundamental principles of these capabilities are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical stress measurement by an achromatic optical digital speckle pattern interferometry strain sensor with radial in-plane sensitivity: experimental comparison with electrical strain gauges

This paper shows the optical setup of a radial in-plane digital speckle pattern interferometer which uses an axis-symmetrical diffractive optical element (DOE) to obtain double illumination. The application of the DOE gives in-plane sensitivity which only depends on the grating period of the DOE instead of the wavelength of the laser used as illumination source. A compact optical layout was built in order to have a portable optical strain sensor with a circular measurement area of about 5 mm in diameter. In order to compare its performance with electrical strain sensors (strain gauges), mechanical loading was generated by a four-point bending device and simultaneously monitored by the optical strain sensor and by two-element strain gauge rosettes. Several mechanical stress levels were measured showing a good agreement between both sensors. Results showed that the optical sensor could measure applied mechanical strains with a mean uncertainty of about 5% and 4% for the maximum and minimum principal strains, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NMIS with Imaging and Gamma Ray Spectrometry for Pu, HEU, HE and Other Materials

The Nuclear Material Identification System (NMIS) has been under development at ORNL and the National Nuclear Security Administration (NNSA) Y-12 National Security Complex since 1984. In the mid-1990s, what is now the US Department of Energy (DOE) Office of Nuclear Verification (ONV) realized that it was a useful technology for future arms control treaty applications and supported further development of the system. In 2004, fast-neutron imaging was incorporated into the system. In 2007, the ONV decided to develop a fieldable version of the system, designated as FNMIS, for potential use in future treaties. The FNMIS is being developed to be compatible with the eventual incorporation of gamma-ray spectrometry and an information barrier. This report addresses how and what attributes could be determined by the FNMIS system with gamma-ray spectrometry. The NMIS is a time-dependent coincidence system that incorporates tomographic imaging (including mapping of the fission sites) and gamma-ray spectrometry. It utilizes a small, lightweight (30 lb), portable deuterium-tritium (DT) neutron (14.1 MeV) generator (4 x 10 7 neutrons/second) for active interrogation and can also perform passive interrogation. A high-purity germanium (HPGe) gamma-ray detector with multichannel analysis can be utilized in conjunction with the source for active interrogation or passively. The system uses proton recoil scintillators: 32 small 2.5 x 2.5 x 10.2-cm-thick plastic scintillators for imaging and at least two 2 x 2 arrays of 27 x 27 x 10-cm-thick plastic scintillators that detect induced fission radiation. The DT generator contains an alpha detector that time and directionally tags a fan beam of some of the neutrons emitted and subdivides it into pixels. A fast (1 GHz) time correlation processor measures the time-dependent coincidence among all detectors in the system. A computer-controlled scanner moves the small detectors and the source appropriately for scanning a target object for imaging. The system is based on detection of transmitted 14.1 MeV neutrons, fission neutrons, and gamma rays from spontaneous, inherent source fission of the target, fission neutrons and gamma rays induced by the external DT source, gamma rays from natural emissions of uranium and plutonium, and induced gamma-ray emission by the interaction of the 14.1 MeV neutrons from the DT source. The NMIS can and has been used with a time-tagged californium spontaneous fission source. It has also been used with pulsed interrogation sources such as LINACs, DT, and deuterium-deuterium (DD) sources. This system is uniquely suited for detection of shielded highly enriched uranium (HEU), plutonium, and other special nuclear materials and detection of high explosives (HE) and chemical agents. The NMIS will be adapted to utilize a trusted processor that incorporates information barrier and authentication techniques using open software and then be useful in some international applications for materials whose characteristics may be classified. The proposed information barrier version of the NMIS system would consist of detectors and cables, the red (classified side) computer system, which processes the data, and the black (unclassified side) computer, which handles the computer interface. The system could use the 'IB wrapper' concept proposed by Los Alamos National Laboratory and the software integrity (digital signatures) system proposed by Sandia. Since it is based entirely on commercially available components, the entire system, including NMIS data acquisition boards, can be built with commercial off-the-shelf components. This system is being developed into a fieldable system (FNMIS) for potential arms control treaties by the ONV. The system will be modularly constructed with the RF shielded modules connected to the processor by appropriate control and signal cable in metal conduit. The FNMIS is presently being designed for eventual incorporation of gamma-ray spectrometry and an information barrier to protect classified information. The system hardware and software can be configured to obtain the following: plutonium presence, plutonium mass, Pu-240/239 ratio, plutonium geometry, plutonium metal vs non-metallic (absence of metal), time (age) since processing for plutonium (or last purification), uranium presence, uranium mass, uranium enrichment, uranium geometry, uranium metal vs non-metallic compound (absence of metal), beryllium presence and mass, tritium and deuterium gas bottle presence, HE, and chemical weapons. A matrix of the quantities determined, the method of determination, whether active (external neutron source) or passive, and the measurement equipment involved is given in the Tables 1-4. Some of these attributes can be obtained by multiple data analysis methods. The gamma-ray spectrometry methods for HEU, plutonium, and HE have been developed by other laboratories, are well known, and will be incorporated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EPC-ES WIPP WAC Appendix A Equivalence Support Measurements 2019-2020

Characterization of low-level waste (LLW) at Los Alamos National Laboratory (LANL) is primarily performed by the Environmental Protection and Compliance - Environmental Stewardship (EPC-ES) Characterization Services team and/or the Nuclear Process Infrastructure (NPI--9) Nuclear Material Support Services team (hereafter referred to as the gamma spectroscopy teams). The gamma spectroscopy teams use portable high-purity germanium (HPGe) detector systems for the nondestructive assay (NDA) characterization of LLW. Controlled-approved procedures and processes for the use of such systems to assay LLW items are currently in place. Additionally, a number of performance studies have been conducted by the gamma spectroscopy teams to support the efficacy and quality of assay results generated by the established NDA process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Plutonium Detection with Straw Neutron Detectors

A kilogram of weapons grade plutonium gives off about 56,000 neutrons per second of which 55,000 neutrons come from spontaneous fission of 240Pu (~6% by weight of the total plutonium). Actually, all even numbered isotopes (238Pu, 240Pu, and 242Pu) produce copious spontaneous fission neutrons. These neutrons induce fission in the surrounding fissile 239Pu with an approximate multiplication of a factor of ~1.9. This multiplication depends on the shape of the fissile materials and the surrounding material. These neutrons (typically of energy 2 MeV and air scattering mean free path >100 meters) can be detected 100 meters away from the source by vehicle-portable neutron detectors. [1] In our current studies on neutron detection techniques, without using 3He gas proportional counters, we designed and developed a portable high-efficiency neutron multiplicity counter using 10B-coated thin tubes called straws. The detector was designed to perform like commercially available fission meters (manufactured by Ortec Corp.) except instead of using 3He gas as a neutron conversion material, we used a thin coating of 10B.

plutonium, neutron, straw↗