Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Planning software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Design of Mariner 9 Science Sequences using Interactive Graphics Software

This paper discusses the analyst/computer system used to design the daily science sequences required to carry out the desired Mariner 9 science plan. The Mariner 9 computer environment, the development and capabilities of the science sequence design software, and the techniques followed in the daily mission operations are discussed. Included is a discussion of the overall mission operations organization and the individual components which played an essential role in the sequence design process. A summary of actual sequences processed, a discussion of problems encountered, and recommendations for future applications are given.

Freeman, J. E.↗

Prototyping and validating requirements of radiation and nuclear emergency plan simulator

Organizational incapability in developing unrealistic, impractical, inadequate and ambiguous mechanisms of radiological and nuclear emergency preparedness and response plan (EPR) causing emergency plan disorder and severe disasters. These situations resulting from 65.6% of poor definition and unidentified roles and duties of the disaster coordinator. Those unexpected conditions brought huge aftermath to the first responders, operators, workers, patients and community at large. Hence, in this report, we discuss prototyping and validating of Malaysia radiation and nuclear emergency preparedness and response plan simulation model (EPRM). A prototyping technique was required to formalize the simulation model requirements. Prototyping as systems requirements validation was carried on to endorse the correctness of the model itself against the stakeholder’s intensions in resolving those organizational incapability. We have made assumptions for the proposed emergency preparedness and response model (EPRM) through the simulation software. Those assumptions provided a twofold of expected mechanisms, planning and handling of the respective emergency plan as well as in bringing off the hazard involved. This model called RANEPF (Radiation and Nuclear Emergency Planning Framework) simulator demonstrated the training emergency response perquisites rather than the intervention principles alone. The demonstrations involved the determination of the casualties’ absorbed dose range screening and the coordination of the capacity planning of the expected trauma triage. Through user-centred design and sociotechnical approach, RANEPF simulator was strategized and simplified, though certainly it is equally complex.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using Ada for a distributed, fault tolerant system

It is pointed out that advanced avionics applications increasingly require underlying machine architectures which are damage and fault tolerant, and which provide access to distributed sensors, effectors and high-throughput computational resources. The Advanced Information Processing System (AIPS), sponsored by NASA, is to provide an architecture which can meet the considered requirements. Ada was selected for implementing the AIPS system software. Advantages of Ada are related to its provisions for real-time programming, error detection, modularity and separate compilation, and standardization and portability. Chief drawbacks of this language are currently limited availability and maturity of language implementations, and limited experience in applying the language to real-time applications. The present investigation is concerned with current plans for employing Ada in the design of the software for AIPS. Attention is given to an overview of AIPS, AIPS software services, and representative design issues in each of four major software categories.

Dewolf, J. B.↗

Designing Autonomy into Interfaces for Long-Duration Missions

As NASA develops technologies for long-duration crewed missions, we must understand how communication between ground control teams and astronauts differs from the current dynamic to adapt new concepts for long-duration mission operations. Today, ground control teams support astronauts with immediate availability to answer questions, resolve issues, and manage activities. In the near future, however, extended communication delays during long-duration missions will require astronauts to become more autonomous. As many of the responsibilities shift from the ground control teams to the astronauts on-board, the concept of operations must also change from how it functions today. With increased astronaut autonomy, software tools must be developed that enable efficient completion of mission tasks without increased mental workload. Designing software tools to facilitate crew autonomy requires development teams to know which data will enhance quick decision making while providing necessary context for situational awareness of systems being managed on-board. NASA's Autonomous Systems and Operations (ASO) team is presently developing a software interface tool, EXPRESS (EXpedite the PRocessing of Experiments for Space Station) 2.5 to enable a long-duration crew to schedule activities for and operate autonomous systems. This paper describes details of the integrated human factors approach that drove the design of the elements of the software tool, including self-managed scheduling, constraint-driven planning, autonomous system fault recovery, and recommended troubleshooting actions. Additionally, this paper will chronicle ASO modifications of the user interface after the team's first flight demonstration, how it was based on lessons learned during software development, as well as from crew feedback in order to develop the current version which will be demonstrated on ISS in 2021. In the upcoming ISS demonstration, the astronaut crew will be given scenarios for scheduling and operating autonomous system activities, including off-nominal scenarios and autonomous system recoveries. The demonstration of the EXPRESS 2.5 tool is a step towards improved levels of autonomy as our new journeys take us farther into space.

autonomy↗

SU-F-T-301: Planar Dose Pass Rate Inflation Due to the MapCHECK Measurement Uncertainty Function

Purpose: To quantify the effect of the Measurement Uncertainty function on planar dosimetry pass rates, as analyzed with Sun Nuclear Corporation analytic software (“MapCHECK” or “SNC Patient”). This optional function is toggled on by default upon software installation, and automatically increases the user-defined dose percent difference (%Diff) tolerance for each planar dose comparison. Methods: Dose planes from 109 IMRT fields and 40 VMAT arcs were measured with the MapCHECK 2 diode array, and compared to calculated planes from a commercial treatment planning system. Pass rates were calculated within the SNC analytic software using varying calculation parameters, including Measurement Uncertainty on and off. By varying the %Diff criterion for each dose comparison performed with Measurement Uncertainty turned off, an effective %Diff criterion was defined for each field/arc corresponding to the pass rate achieved with MapCHECK Uncertainty turned on. Results: For 3%/3mm analysis, the Measurement Uncertainty function increases the user-defined %Diff by 0.8–1.1% average, depending on plan type and calculation technique, for an average pass rate increase of 1.0–3.5% (maximum +8.7%). For 2%, 2 mm analysis, the Measurement Uncertainty function increases the user-defined %Diff by 0.7–1.2% average, for an average pass rate increase of 3.5–8.1% (maximum +14.2%). The largest increases in pass rate are generally seen with poorly-matched planar dose comparisons; the MapCHECK Uncertainty effect is markedly smaller as pass rates approach 100%. Conclusion: The Measurement Uncertainty function may substantially inflate planar dose comparison pass rates for typical IMRT and VMAT planes. The types of uncertainties incorporated into the function (and their associated quantitative estimates) as described in the software user’s manual may not accurately estimate realistic measurement uncertainty for the user’s measurement conditions. Pass rates listed in published reports or otherwise compared to the results of other users or vendors should clearly indicate whether the Measurement Uncertainty function is used.

60 APPLIED LIFE SCIENCES↗

Estimating Software Reliability for Space Launch Vehicles in Probabilistic Risk Assessment (PRA)

It is acutely recognized in the Probabilistic Risk Assessment (PRA) field that software plays a defining role in overall system reliability for all modern systems across a wide variety of industries. Regardless of whether the software is embedded firmware for working components or elements, part of a Human-Machine-Interface, or automated command and control logic, the success of the software to fulfill its function under nominal and off-nominal environments will be a dominant contributor to system reliability. It is also recognized that software reliability prediction and estimation is one of the more challenging and questionable aspects of any PRA or system analyses due to the nature of software and its integration with physics based systems. Irrespective of this dichotomy, any incorporation of software reliability methods requires that the contributions are accountable, quantitative, and tractable. This paper provides a brief overview of software reliability methods, establishes some minimum requirements that the methods should incorporate for completeness, and provides a logic structure for applying software reliability. Model resolution will be discussed that supports current testing plans and trade studies. We will provide initial recommendations for use in the National Aeronautics and Space Administration (NASA) PRA and present a future dynamic option for software and PRA. Space Launch Vehicle software is recognized to be reliable in static conditions, yet relatively vulnerable to a set of failure modes in changing environments/flight phases. Two quantitative methods were chosen to incorporate software reliability into a Space Launch Vehicle PRA accounting for phase adjustments. One method predicts latent software failure using statistical methods, and the second provides estimates of coding errors and software operating system failures based on test and historical data. Software uncertainty will also be discussed. It is determined that recommendations for PRA software reliability should be modeled at the software module level where multiple software components compose a module and combinations of the software architecture can lead to a functional failure.

Steven D. Novack↗

Orbital flight simulation utility software unit specifications

The HP PASCAL source code contained in pages 6 through 104 was developed for the Mission Planning and Analysis Division (MPAD) and takes the place of detailed flow charts defining the specifications for a Utility Software Unit designed to support orbital flight simulators such as MANHANDLE and GREAS (General Research and Engineering Analysis Simulator). Besides providing basic input/output, mathematical, vector, matrix, quaternion, and statistical routines for such simulators, one of the primary functions of the Utility Software Unit is to isolate all system-dependent code in one well-defined compartment, thereby facilitating transportation of the simulations from one computer to another. Directives to the PASCAL compilers of the HP-9000 Series 200 PASCAL 3.0 operating system and the HP-9000 Series 500 HP-UX 5.0 operations systems are also provided.

Wilson, S. W.↗

Low SWaP Onboard Satellite Navigation, Guidance, and Control Technology

Onboard autonomy is a necessity for responsive space operations. Autonomous navigation, guidance, and control (NGC) enables space missions to reduce their dependence on high demand ground assets and costly ground personnel. It also allows for in-situ decision making and higher return on mission data. A flight software and hardware system providing this capability, called “autoNGC,” is currently being developed at NASA Goddard Space Flight Center for infusion into multiple future missions. The first build of autoNGC, providing autonomous navigation for lunar orbiting spacecraft, is targeted for completion by Fall 2024. It provides sensor fusion of multiple measurement types including pseudo-range from a weak signal Global Navigation Satellite Service (GNSS) receiver, 1-way and 2-way direct to Earth (DTE) range and Doppler, bearing and range from optical camera sensed images, and an accelerometer. AutoNGC is also being targeted for future missions that involve small body proximity operations, Sun Earth Libration point orbits, and distributed systems missions (DSMs) including those at outer planets. AutoNGC flight software is being built upon the plug-and-play architecture of the core Flight System (cFS) [Ref. 1]. Figure (Slide 7) shows the message-based software bus layout of various software applications (“apps”) consisting of the standard cFS apps and autoNGC interface apps and libraries. Accurate onboard navigation and timing is obtained through the Goddard Enhanced Onboard Navigation System (GEONS) software library [Ref. 2], which fuses different measurement types through an extended Kalman filter (EKF) framework. Optical measurements that are ingested in GEONS are provided by the cFS Goddard Image Analysis and Navigation Tool (cGIANT) app [Ref. 3]. This app processes optical images to extract the bearing angles of the centroid of the imaged body (near or far), the range to the imaged body, and/or of the features on the surface of a body to perform terrain relative navigation (TRN). Measurement of range to the body’s center of mass can also be derived from the detection of the limb. The first build of autoNGC for a lunar orbiting spacecraft is a minimal size, weight, and power (SWaP) hardware design allowing for inclusion into CubeSats and SmallSat-size class buses. Advancements in miniaturized space processors, such as the SpaceCube 3.0 Mini and the SpaceCube Mini-Z [Ref. 4] are utilized for low SWaP while maintaining a high level of performance. Figure (Slide 11) shows the composition of the first autoNGC build. The current enclosure design has dimensions 12 cm x 17 cm x 13.5 cm. The box mass is expected to be less than 2 kg, and the nominal power is 21 W. The hardware interfaces are designed for flexibility with a variety of sensor inputs. The achievable navigation performance depends on the sensors utilized, including the onboard clock for 1-way pseudo-range measurements. Analysis using a configuration that consists of weak signal GPS, TRN, and 1-way DTE has shown position and velocity accuracies of 10 meters and 2 cm/s (3-σ ) RSS, respectively, with onboard time knowledge estimated to better than 13 ns (3-σ ), for a spacecraft in a representative 12-hour eccentric lunar orbit. Other measurement types such as x-rays from known pulsars (called XNAV) and cross-links can also be processed in GEONS. With the plug-and-play architecture of autoNGC, cFS apps can easily be added and replaced, even after launch. Goddard is actively seeking partners to collaborate in the development of additional capabilities for autoNGC, including industry, academia, and others across the US Government. Plans are being formulated to make the autoNGC software platform available for use by any US government organization to leverage the non-recurring engineering associated with the development of onboard autonomous NGC 3 capabilities. As advancements in space qualified sensors, microprocessors, and algorithms are made, the autoNGC platform provides a ready starting point for inclusion of these technologies.

C. J. Gramling↗

Tools of the Future: How Decision Tree Analysis Will Impact Mission Planning

The universe is infinitely complex; however, the human mind has a finite capacity. The multitude of possible variables, metrics, and procedures in mission planning are far too many to address exhaustively. This is unfortunate because, in general, considering more possibilities leads to more accurate and more powerful results. To compensate, we can get more insightful results by employing our greatest tool, the computer. The power of the computer will be utilized through a technology that considers every possibility, decision tree analysis. Although decision trees have been used in many other fields, this is innovative for space mission planning. Because this is a new strategy, no existing software is able to completely accommodate all of the requirements. This was determined through extensive research and testing of current technologies. It was necessary to create original software, for which a short-term model was finished this summer. The model was built into Microsoft Excel to take advantage of the familiar graphical interface for user input, computation, and viewing output. Macros were written to automate the process of tree construction, optimization, and presentation. The results are useful and promising. If this tool is successfully implemented in mission planning, our reliance on old-fashioned heuristics, an error-prone shortcut for handling complexity, will be reduced. The computer algorithms involved in decision trees will revolutionize mission planning. The planning will be faster and smarter, leading to optimized missions with the potential for more valuable data.

Otterstatter, Matthew R.↗

Virtual Diagnostics Interface (ViDI) for Planning Laser-Based Wind Tunnel Experiments

Virtual Diagnostics Interface (ViDI), originally introduced by Richard Schwartz in 2004 and described again by Alderfer, et. al., in 2007, is an interactive 3D software tool developed at NASA Langley Research Center to serve three main purposes: assist in pre-test planning, enhance post-test image analysis and visualization, and serve as a central location for data storage and distribution.1,2 ViDI is composed of custom-developed software and Autodesk® 3ds Max® as it incorporates Computer Aided Design (CAD) models with the results obtained from optical diagnostics.3 This software tool has proven useful in the field of optical diagnostics where pre-test planning of beam paths, optical elements, and test articles must be carried out to avoid interference, ensure spatial resolution is sufficient, and the camera Field of View (FoV) is adequate for the field of interest. Typically, practical considerations such as the distance a camera is from the region of interest, the angles at which the camera is oriented and issues such as the size of the camera and its sensor and size and focal length lens as well as the path of the laser need to be taken into account to predict a successful measurement. An example application of ViDI is shown in Fig.1 where an experiment to investigate flow separation over the wing of the High Lift Common Research Model (HL-CRM) is currently being planned in the National Transonic Facility (NTF) at NASA Langley Research Center.

virtual diagnostics interface↗

Remote sensing information sciences research group: Browse in the EOS era

The problem of science data browse was examined. Given the tremendous data volumes that are planned for future space missions, particularly the Earth Observing System in the late 1990's, the need for access to large spatial databases must be understood. Work was continued to refine the concept of data browse. Further, software was developed to provide a testbed of the concepts, both to locate possibly interesting data, as well as view a small portion of the data. Build II was placed on a minicomputer and a PC in the laboratory, and provided accounts for use in the testbed. Consideration of the testbed software as an element of in-house data management plans was begun.

Estes, John E.↗

MIDAS - A microcomputer-based image display and analysis system with full Landsat frame processing capabilities

Image Display and Analysis Systems (MIDAS) developed at NASA/Ames for the analysis of Landsat MSS images is described. The MIDAS computer power and memory, graphics, resource-sharing, expansion and upgrade, environment and maintenance, and software/user-interface requirements are outlined; the implementation hardware (including 32-bit microprocessor, 512K error-correcting RAM, 70 or 140-Mbyte formatted disk drive, 512 x 512 x 24 color frame buffer, and local-area-network transceiver) and applications software (ELAS, CIE, and P-EDITOR) are characterized; and implementation problems, performance data, and costs are examined. Planned improvements in MIDAS hardware and design goals and areas of exploration for MIDAS software are discussed.

Hofman, L. B.↗

Smart Planning for Radioactive Source Transport Advanced Tools for Increased Safety and Efficiency

End-of-life (EOL) management of high-activity radioactive sources is made uniquely challenging by the inherent risks associated with storage and transportation of these sources, the complex logistics involved, and the strict requirements for regulatory compliance. Traditional methods lack comprehensive tools for accurate site assessments and precision planning for the transportation of radioactive sources. They also frequently fail to provide the adaptability required to consider diverse operational environments, resulting in inefficiencies and potential safety concerns. This paper introduces a novel software solution developed to address these issues by integrating advanced technologies such as light detection and ranging (LiDAR)-based 3D environment modeling, smart dynamic route planning, and customizable measurement functionalities. This software enables detailed terrain visualizations, facilitating thorough environmental assessments and enabling users to virtually navigate, analyze, and plan site-specific operations. Among the key features are a user-centric interface for virtual navigation, precise site measurement tools for site evaluations, interactive visualizations that highlight potential operational hazards, dynamic route planning capabilities, and real-time collision detection to promote safe workflows. By demonstrating the effectiveness of this tool through real-world application, the present work underscores the tool’s potential to revolutionize radioactive source EOL management by improving operational efficiencies, minimizing risk, and advancing the state of practice to achieve suitable and secure radioactive material handling.

99 - GENERAL AND MISCELLANEOUS↗

SU-E-T-27: A Tool for Routine Quality Assurance of Radiotherapy Dose Calculation Software

Purpose: Dose calculation software is thoroughly evaluated when it is commissioned; however, evaluation of periodic software updates is typically limited in scope due to staffing constraints and the need to quickly return the treatment planning system to clinical service. We developed a tool for quickly and comprehensively testing and documenting dose calculation software against measured data. Methods: A tool was developed using MatLab (The MathWorks, Natick, MA) for evaluation of dose calculation algorithms against measured data. Inputs to the tool are measured data, reference DICOM RT PLAN files describing the measurements, and dose calculations in DICOM format. The tool consists of a collection of extensible modules that can perform analysis of point dose, depth dose curves, and profiles using dose difference, distance-to-agreement, and the gamma-index. Each module generates a report subsection that is incorporated into a master template, which is converted to final form in portable document format (PDF). Results: After each change to the treatment planning system, a report can be generated in approximately 90 minutes. The tool has been in use for more than 5 years, spanning 5 versions of the eMC and 4 versions of the AAA. We have detected changes to the algorithms that affected clinical practice once during this period. Conclusion: Our tool provides an efficient method for quality assurance of dose calculation software, providing a complete set of tests for an update. Future work includes the addition of plan level tests, allowing incorporation of, for example, the TG-119 test suite for IMRT, and integration with the treatment planning system via an application programming interface. Integration with the planning system will permit fully-automated testing and reporting at scheduled intervals.

07 ISOTOPE AND RADIATION SOURCES↗

Cassini's Maneuver Automation Software (MAS) Process: How to Successfully Command 200 Navigation Maneuvers

To keep Cassini on its complex trajectory, more than 200 orbit trim maneuvers (OTMs) have been planned from July 2004 to July 2010. With only a few days between many of these OTMs, the operations process of planning and executing the necessary commands had to be automated. The resulting Maneuver Automation Software (MAS) process minimizes the workforce required for, and maximizes the efficiency of, the maneuver design and uplink activities. The MAS process is a well-organized and logically constructed interface between Cassini's Navigation (NAV), Spacecraft Operations (SCO), and Ground Software teams. Upon delivery of an orbit determination (OD) from NAV, the MAS process can generate a maneuver design and all related uplink and verification products within 30 minutes. To date, all 112 OTMs executed by the Cassini spacecraft have been successful. MAS was even used to successfully design and execute a maneuver while the spacecraft was in safe mode.

Yang, Genevie Velarde↗

WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies.

60 APPLIED LIFE SCIENCES↗

SU-E-T-519: Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom

Purpose To characterize the Cyberknife (CK) robotic system’s dosimetric accuracy of the delivery of MultiPlan’s Monte Carlo dose calculations using EBT3 radiochromic film inserted in a thorax phantom. Methods The CIRS XSight Lung Tracking (XLT) Phantom (model 10823) was used in this study with custom cut EBT3 film inserted in the horizontal (coronal) plane inside the lung tissue equivalent phantom. CK MultiPlan v3.5.3 with Monte Carlo dose calculation algorithm (1.5 mm grid size, 2% statistical uncertainty) was used to calculate a clinical plan for a 25-mm lung tumor lesion, as contoured by the physician, and then imported onto the XLT phantom CT. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0– 800 cGy. The test films (n=3) were irradiated using 325 cGy to the prescription point. Films were scanned 48 hours after irradiation using an Epson v700 scanner (48 bits color scan, extracted red channel only, 96 dpi). Percent absolute dose and relative isodose distribution difference relative to the planned dose were quantified using an in-house QA software program. Multiplan Monte Carlo dose calculation was validated using RCF dosimetry (EBT3) and gamma index criteria of 3%/3mm and 2%/2mm for absolute dose and relative isodose distribution measurement comparisons. Results EBT3 film measurements of the patient plans calculated with Monte Carlo in MultiPlan resulted in an absolute dose passing rate of 99.6±0.4% for the Gamma Index of 3%/3mm, 10% dose threshold, and 95.6±4.4% for 2%/2mm, 10% threshold criteria. The measured central axis absolute dose was within 1.2% (329.0±2.5 cGy) of the Monte Carlo planned dose (325.0±6.5 cGy) for that same point. Conclusion MultiPlan’s Monte Carlo dose calculation was validated using the EBT3 film absolute dosimetry for delivery in a heterogeneous thorax phantom.

60 APPLIED LIFE SCIENCES↗

SEDSAT 1 Technologies

The original goals of this project were to support the development of SEDSAT 1 for a tethered launch in July of 1997. This specifically required: (1) Monitoring development progress against a comprehensive delivery plan; (2) Incremental development and release of CDS and SEASIS software; (3) Supporting the integration of version 1.0 SEASIS software that will allow minimal autonomous operation without a software reload. These algorithms would include image quality evaluation, attitude determination, and autonomous earth imaging; and (4) Developing software requirements and design for ground segment software, concentrating on command and data download capability; and interface to external development efforts for a more comprehensive software suite to be used after the initial mission. Because of an unfavorable space shuttle safety review of the SEDS-3 tether deployer, and cost and schedule problems in upgrading the deployer, the mission was changed to an independent launch of SEDSAT. The original plan was to do a tether-less deployment from the space shuttle. Since this would have resulted in an unacceptable orbital lifetime, the mission was changed again to a tethered launch from a Delta II in June 1998. As a result of Marshall Space Flight Center's redirection of the SEDS-3 mission away from a tether launch, the whole question of a tether endmass had to be reconsidered. The net result of these multiple changes was twofold. First, we completed work needed to define some aspects of ground software on SEDSAT 1 that would remain constant no matter the launch mode. Second, we developed a set of concepts for using SEDSAT 1 technology to support alternative endmass missions on SEDS-3. Both of these are included.

Maier, Mark W.↗