Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photovoltaic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Lithography-Free Mesa Isolation by Laser Ablation for Multijunction III-V Photovoltaic Space Power Generation

Eliminating photolithography from photovoltaic device processing is a significant opportunity for cost reduction and increased manufacturing throughput. In this work, we test femtosecond laser ablation and scribing as an alternative to contact photolithography and wet chemical etching for mesa isolation of multijunction devices. We demonstrate that upright multijunction devices isolated by using the laser as a scribe to cleave through the substrate had virtually no performance loss when compared to a baseline device processed with photolithography. By contrast, devices isolated by laser ablating through the active layers have performance losses that cannot be fully eliminated with postprocess etching. This demonstration of photolithography-free mesa isolation with no performance losses is promising as a pathway to less expensive and higher throughput III-V device manufacturing.

14 SOLAR ENERGY↗

Artificial Soiling Replication of Field Losses on Commercial Photovoltaic Modules

Here, this study demonstrates the capabilities of an indoor artificial soiling approach developed to closely replicate the natural, cyclic soil accumulation processes in the field-dust suspension, deposition, and sedimentation/cementation-for a subtropical climate. In this work, a near-field environment is replicated in an artificial soiling cubic chamber through controlled regulation of humidity, temperature, dust type, and dust concentration, based on site-specific historical climate data. Two different models (MA and MB) of full-size commercial photovoltaic modules from a single manufacturer, installed side by side in the mid-Atlantic United States, were retrieved and subjected to artificial soiling experiments and various characterization measurements, including short-circuit current, colorimetry, reflectance, X-ray fluorescence, laser diffraction, and optical microscopy. Both in the field and in our improved field-representative artificial soiling tests, the MA model experienced roughly twice the soiling loss as the MB model. To closely replicate the field soiling losses for a site-specific climate, it is critical to include: 1) The use of field-collected dust with identical dust chemistry and particle distribution instead of standardized ISO 12103 Arizona Road dusts, 2) the use of only a small amount of field-collected dust inside the chamber during the deposition process (e.g., 0.15 g), and 3) the preconditioning of the surface coating for the partial/full dose of UV stress as experienced in the field during sunlight exposure and the abrasion as experienced in the field during regular module cleaning activities, if/as needed. The field-representative artificial soiling method developed here could potentially be adopted for rank ordering of various antisoiling coatings developed by researchers and industry stakeholders.

14 SOLAR ENERGY↗

Surface Stress Characterization and Trends in Thermally Strengthened Photovoltaic Module Glass

Simultaneous changes in photovoltaic (PV) module architecture-such as increased area, replacing the polymeric backsheet with a glass backsheet, and reducing glass thickness from 3.2 to 2.0 mm-have resulted in a novel failure called spontaneous glass breakage. Spontaneous glass breakage results in front and/or rear glass failure without any obvious cause. The resulting low-energy fracture patterns have raised concerns about the thermal strengthening in 2.0-mm glass. We present validation of a nondestructive method for measuring the glass surface stress in PV modules. We use a scattered light polariscope to examine the glass properties of 11 modules from 6 solar fields, with and without spontaneous glass breakage. Based on a Mann-Whitney test p-value of 1.4 x 10-6, we conclude that there is a correlation between lower surface stress and susceptibility to spontaneous breakage. A Kendall's Tau test p-value of 2.0 x 10-4 indicates a correlation between increased module area and lower surface stress. We find that 2.0-mm glass can be, and often is, fully tempered (surface stress ≥69 MPa), but inspecting the fracture pattern is not a reliable way to assess the amount of thermal strengthening. A combination of factors, not just surface stress, influences glass breakage.

14 SOLAR ENERGY↗

Electromagnetic Transient (EMT) Simulation Algorithm for Evaluation of Photovoltaic (PV) Generation Systems

Use of inverter-based resources facilitating renewable energy resources such as photovoltaic (PV) generation is increasing rapidly with decreasing costs and reduced emissions associated. To accommodate such rapid growth of inverter-based resources like PV systems, electromagnetic transient (EMT) simulation models of both PV systems and grids are required to analyze the interaction of PVs in the grid (like the post-event analysis). In addition, the EMT simulation would help with the planning of future power grid with a large number of PVs as well as other inverter-based distributed generation systems. In this paper, the EMT simulation models of PV systems and grids are developed based on the differential algebraic equations (DAEs) representing their EMT dynamics. Furthermore, advanced simulation algorithms including numerical stiffness-based hybrid discretization, DAE clustering and aggregation, multi-order integration, and matrix splitting approaches are applied to accelerate the EMT simulation. The proposed algorithm was applied to 125 PV inverters within 52-bus medium-voltage (MV) distribution grid.

Choi, Jongchan↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Electromagnetic Transient Simulation of Photovoltaic Inverter Using Implicit-Explicit Solver

This paper introduces the implementation of electromagnetic transient (EMT) simulations of a photovoltaic (PV) inverter module using the Implicit-Explicit (ImEx) solver in the Suite of Nonlinear and Differential/Algebraic Equation Solvers (SUNDIALS). This study demonstrates the effectiveness of the ImEx solver in overcoming the challenges inherent in simulating the complex dynamics of PV inverter modules. Furthermore, using SUNDIALS’ ImEx solver module ARKODE for EMT simulation automates key aspects of the process, such as numerical integration, providing substantial benefits including enhanced consistency, faster implementation, reduced human error, and the capability to handle the complexities of advanced numerical integration. By conducting comparative simulations with an implicit method used in commercial software, the research showcases the ImEx solver’s capability in achieving high accuracy and reliability. Results indicate that leveraging the ImEx approach significantly enhances modeling fidelity and reduces simulation setup times, offering a promising tool for the EMT analysis of PV inverter systems in power electronics-dominated power grids.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

Real-time Implementation of a Dual-Active-Bridge Based Multi-Level Photovoltaic Converter

Silicon-carbide based, multi-level converters with dual-active-bridge (DAB) are getting attention for medium voltage, direct grid-connected, utility-scale photovoltaic (PV) applications due to their higher efficiency and power density. To de-risk complex control development for these high-voltage and high-power inverters, hardware-in-the-loop techniques are often required. Due to the high switching frequency and the large number of power electronic switches, off-the-shelf, real-time simulation tools are not yet fully developed for this application, even with FPGA-based simulators. To address this, a new co-simulation approach in FPGA is presented that utilizes Time-Stamped Bridge (TSB) for the higher frequency converters along with detailed fixed conductance based discrete device simulation of the rest of the circuit. A complex DAB-based PV converter with maximum switching frequency of 50 kHz is successfully simulated in real-time in the FPGA and the results are compared with offline simulation results. A controller hardware-in-the-loop (CHIL) platform is developed to demonstrate real-time, closed-loop test results for this DAB-based PV converter.

Dong, Zerui↗

Security Vulnerability and Mitigation in Photovoltaic Systems

Software and firmware vulnerabilities pose security threats to photovoltaic (PV) systems. When patches are not available or cannot be timely applied to fix vulnerabilities, it is important to mitigate vulnerabilities such that they cannot be exploited by attackers or their impacts will be limited when exploited. However, the vulnerability mitigation problem for PV systems has received little attention. This paper analyzes known security vulnerabilities in PV systems, proposes a multi-level mitigation framework and various mitigation strategies including neural network-based attack detection inside inverters, and develops a prototype system as a proof-of-concept for building vulnerability mitigation into PV system design.

14 SOLAR ENERGY↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Maximum Power Reference Tracking Algorithm for Power Curtailment of Photovoltaic Systems

This paper presents an algorithm for power curtailment of photovoltaic (PV) systems under fast solar irradiance intermittency. Based on the Perturb and Observe (P&O) technique, the method contains an adaptive gain that is compensated in real-time to account for moments of lower power availability. In addition, an accumulator is added to the calculation of the step size to reduce the overshoot caused by large irradiance swings. A testbed of a three-phase single-stage, 500 kVA PV system is developed on the OPAL-RT eMEGAsim real-time simulator. Field irradiance data and a regulation signal from PJM (RTO) are used to compare the performance of the proposed method with other techniques found in the literature. Results indicate an operation with smaller overshoot, less dc-link voltage oscillations, and improved power reference tracking capability.

Paduani, Victor↗

Data-Driven Model for Photovoltaic Generation: Comparison with Physical Models Using a Microgrid in Puerto Rico

Photovoltaic (PV) generation is a critical component of microgrids, but its accurate modeling is challenging due to the complex and dynamic interactions between solar irradiance, temperature, and PV system installation. This paper develops a multilayer perceptron (MLP) model that inputs solar irradiance and temperature to estimate the PV generation, and it compares the proposed data-driven model’s performance to two well-known physical models: the single-diode model and the inverter model. The results demonstrate that all the models can reach high levels of accuracy. However, the MLP model outperforms the physical models on average by 4.5 to 6.6 percent in R squared scores and 220 to 290 Watts in RMSE scores, and it does not require physical system parameters. Moreover, the data-driven model can overcome the limitations of the lack of real-time PV generation data.

R pesante colón, Marcos↗

Quantifying the Relationship Between Higher Photovoltaic Module Efficiency and the Adoption of Distributed Solar

The purpose of this study is understanding the relationship between module efficiency, system costs, and the economic and adoption potential of distributed rooftop solar. We use the dGen model to project the economic potential and adoption of high-efficiency photovoltaic (PV) modules across a range of efficiencies and cost scenarios in the continental United States. Our results reveal that high-efficiency modules can modestly increase the projected adoption of distributed solar, but system capital costs may play a larger role in changing the amount of projected adoption.

14 SOLAR ENERGY↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

Correlation of Advanced Accelerated Stress Testing with Polyamide-Based Photovoltaic Backsheet Field-Failures

Cracking of polyamide (PA)-based photovoltaic (PV) backsheet materials has been widely reported for field-aged modules. Failure was not detected by conventional accelerated stress tests (ASTs), which lacked the necessary combination of stress factors and/or factor sequences. PA-based AAA backsheet cracking has since been reproduced through combined and sequential stress testing. Planar- and cross-sectional-optical microscopy as well as Fourier-transform Infrared Spectroscopy (FTIR), have been used to elucidate the mechanical and chemical changes which lead to failure of the backsheet. Field-aged backsheet samples demonstrating failure in various climates (including locations in China and Italy) are also analyzed. Through the analysis, a comparison is made between the different stress testing protocols and the field-aged samples to validate relevance of the advanced stress tests. It is shown that the changes induced through combined-accelerated stress testing (C-AST) were most representative of changes induced by the field, supporting the relevance of C-AST and providing validity for the test protocol.

14 SOLAR ENERGY↗

Development of Testing Methods to Predict Cracking in Photovoltaic Backsheets

In recent years there have been some significant failures of photovoltaic backsheets resulting from inadequacies of design that are not detected in current versions of the qualification standards. In some cases, this has resulted in catastrophic failure in less than 5 y of deployment. In this work, we develop a test sample construction and evaluate accelerated exposure conditions necessary to duplicate the cracking field failure of backsheets using a small and manageable coupon. This sample uses a piece of solder wire to put some controlled topology and stress into the backsheet. Through exposure to different environmental stressors it was found that the application of thermal cycling stresses, after ultraviolet radiation exposure, is of primary importance to duplicate field failures.

14 SOLAR ENERGY↗

Fill Factor Loss in Fielded Photovoltaic Modules Due to Metallization Failures, Characterized by Luminescence and Thermal Imaging

Understanding the causes of photovoltaic module failure in the field can be achieved using spatially-resolved imaging tools in combination with current-voltage (IV) characterization. We evaluate 23 field-degraded modules by comparing their IV characteristics with module images obtained by electroluminescence, photoluminescence, UV-fluorescence, and dark lock-in thermography. We identify primarily metallization failures (metallization series resistance, solder point heating, broken fingers, disrupted interconnects) in these modules that has led to a severe drop in the fill factor and up to 35% power loss over only 2 years of deployment.

14 SOLAR ENERGY↗

Effects of Photovoltaic Module Materials and Design on Module Deformation Under Load

Static structural finite element models of an aluminum-framed crystalline silicon (c-Si) photovoltaic (PV) module and a glass-glass thin film PV module were constructed and validated against experimental measurements of deflection under uniform pressure loading. Parametric analyses using Latin Hypercube Sampling (LHS) were performed to propagate simulation input uncertainties related to module material properties, dimensions, and manufacturing tolerances into expected uncertainties in simulated deflection predictions. This exercise verifies the applicability and validity of finite element modeling for predicting mechanical behavior of solar modules across architectures and enables computational models to be used with greater confidence in assessment of module mechanical stressors and design for reliability. Sensitivity analyses were also performed on the uncertainty quantification data sets using linear correlation coefficients to elucidate the key parameters influencing module deformation. This information has implications on which materials or parameters may be optimized to best increase module stiffness and reliability, whether the key optimization parameters change with module architecture or loading magnitudes, and whether parameters such as frame design and racking must be replicated in reduced-scale reliability studies to adequately capture full module mechanical behavior.

14 SOLAR ENERGY↗