Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Few-Mode Fiber Coupled Superconducting Nanowire Single-Photon Detectors for Photon Efficient Optical Communications

The NASA Glenn Research Center's development of a high-photon efficiency real-time optical communications ground receiver has added superconducting nanowire single-photon detectors (SNSPDs) coupled with few-mode fibers (FMF). High data rate space-to-ground optical communication links require enhanced ground receiver sensitivity to reduce spacecraft transmitter constraints, and therefore require highly efficient coupling from fiber to detector. In the presence of atmospheric turbulence the received optical wave front can be severely distorted introducing higher-order spatial mode components to the received signal. To reduce mode filtering and mismatch loss and the resulting degradations to detector coupling efficiency, we explore the use of few-mode fiber coupling to commercial single-pixel SNSPDs. Graded index 20-µm few-mode fibers allow the commercial single pixel SNSPD's active area to couple with equal efficiency as single mode fibers. Here we determine detector characteristics such as count rate, detection efficiency, dark counts, and jitter, as well as detection efficiencies for higher-order fiber spatial modes. Additionally, we assess the laboratory performance of the detectors in an optical system which emulates future deep space optical communications links.

Vyhnalek, Brian E.↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gallium oxide semiconductor-based large volume ultrafast radiation hard spectroscopic scintillators

We report on the development of the first-ever inorganic radiation-hard moisture-insensitive large volume spectroscopic semiconductor-based scintillator with less than 2 ns decay time and light yields as high as 8000 ph/MeV. Despite extensive research into scintillator materials, the quest for an ideal scintillator combining ultrafast decay times (akin to BaF 2 and Yb-doped scintillators such as Lu 2 O 3 :Yb), high light yields (exceeding 2000 photons per MeV), spectroscopic capabilities, and exceptional radiation hardness remain unfulfilled. In this study, we demonstrate and report for the first time the viability of large-volume (up to 20 mm thickness) gallium oxide (β-Ga 2 O 3 ) semiconductor-based scintillators for applications requiring these properties. These β-Ga 2 O 3 scintillators were grown using the fast turnaround (~2 days) crucible-free optical float zone (FZ) technique. The high light yield and ultrafast decay time of these high-purity n-type semiconductors with free carrier concentration of 6 × 10 17 cm –3 are attributed to native defects, specifically oxygen vacancies (V O ) and gallium–oxygen vacancy pairs (V Ga –V O ), generated during optimized FZ growth. The ultrafast decay, along with high light yield, enables excellent timing resolution and high count rate detection for applications like time-of-flight positron emission tomography, physics experiments, and nuclear safety. The radiation hardness of these devices has been documented in a separate publication.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gamma-ray and millimeter-wave emissions from the 1991 June X-class solar flares

We have studied the spectacular 1991 June X-class flares using gamma-ray data from the Charged Particle Detectors (CPDs) of the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) and 80 GHz millimeter data from Nobeyama, Japan. The CPDs were the only CGRO instrument that did not saturate during the extremely intense 1991 June 4 flare. We have shown that for this flare the CPDs respond to MeV photons, most of which are due to bremsstrahlung produced by relativistic electrons at the Sun. We have further shown that the gamma-ray and millimeter observations agree numerically if the 80 GHz radiation is gyrosynchrotron radiation produced by trapped electrons and the gamma rays are thick-target bremsstrahlung due to electrons precipitating out of the trap. The requirement that the trapping time obtained from the numerical comparison be consistent with the observed time profiles implies a magnetic field between about 200 and 300 G and an electron spectral index between about 3 to 5. By comparing the CPD observations with both the 80 GHz data and nuclear line data from the Energetic Gamma Ray Experiment Telescope (EGRET) and the Oriented Scintillation Spectroscopy Experiment (OSSE) on CGRO for the flares of June 4, 6, 9, and 11, we found that the ratio of the CPD counts to both the millimeter flux densities and the nuclear line fluences decreases with decreasing flare heliocentric angle. All of these flares were produced in the same active region. We interpreted this result in terms of a loop model in which the gyrosynchrotron emission is produced in the coronal portion of the loop where the electrons are kept isotropic by pitch angle scattering due to plasma turbulence, while the bremsstrahlung is produced by precipitating electrons that interact anisotropically. We found that the trapping time in the coronal portion is time dependent, reaching a minimum of about 10 s at the peak of the CPD count rate. We suggested the damping of the turbulence as a possible reason for the variation of the trapping time. turbulence as a possible reason for the variation of the trapping time.

Ramaty, Reuven↗

Verification and Validation Tests of Gamma Library of MC2-3 for Coupled Neutron and Gamma Heating Calculation

For the accurate assessment of the heat generation rate in fast reactors, the gamma library of MC2 -3 and the MC2 -3 + GAMSOR procedure employing the coupled neutron and gamma heating calculation has been thoroughly verified against Monte Carlo results and validated using the ZPPR-15D gamma dose measurement data. NJOY outputs are post-processed in a consistent way with the NJOY procedure to avoid any missing data or double counting of data. Prompt heating for 379 out of 391 isotopes in the gamma library was verified against MCNP6.2 to within 1% relative error in total heating for most isotopes. For both a simple one-dimensional slab problem representing a sodium cooled fast reactor and the Experimental Breeder Reactor II (EBR-II) benchmark problem, the root-mean-square values of assembly power error were less than 0.5% for fuel assemblies, ~1% in blankets and ~1 to ~3% in reflectors compared to MCNP6.2 results. The most plausible cause for the 3% error in a reflector assembly is believed to be the error in the multigroup neutron cross sections for the reflector assembly. For validation, gamma doses measured with thermoluminiscent dosimeters (TLDs) in the ZPPR-15D experiment were calculated using GAMSOR. Due to the uncertainty in the TLD measurement with regards to the energy deposition of photons and neutrons, the validation data leads to a 12.7% uncertainty on the experimental measurement. With this uncertainty bound, the calculated doses all fell within one standard deviation of the measured value. Combined with the accurate calculation of reaction rate distributions and neutron spectrum measurements, these results indicate good agreement for the neutron and gamma heating calculations that were performed.

coupled neutron and gamma heating↗

Spectral quality affects disease development of three pathogens on hydroponically grown plants

Plants were grown under light-emitting diode (LED) arrays with various spectra to determine the effects of light quality on the development of diseases caused by tomato mosaic virus (ToMV) on pepper (Capsicum annuum L.), powdery mildew [Sphaerotheca fuliginea (Schlectend:Fr.) Pollaci] on cucumber (Cucumis sativus L.), and bacterial wilt (Pseudomonas solanacearum Smith) on tomato (Lycopersicon esculentum Mill.). One LED (660) array supplied 99% red light at 660 nm (25 nm bandwidth at half-peak height) and 1% far-red light between 700 to 800 nm. A second LED (660/735) array supplied 83% red light at 660 nm and 17% far-red light at 735 nm (25 nm bandwidth at half-peak height). A third LED (660/BF) array supplied 98% red light at 660 nm, 1% blue light (BF) between 350 to 550 nm, and 1% far-red light between 700 to 800 nm. Control plants were grown under broad-spectrum metal halide (MH) lamps. Plants were grown at a mean photon flux (300 to 800 nm) of 330 micromoles m-2 s-1 under a 12-h day/night photoperiod. Spectral quality affected each pathosystem differently. In the ToMV/pepper pathosystem, disease symptoms developed slower and were less severe in plants grown under light sources that contained blue and UV-A wavelengths (MH and 660/BF treatments) compared to plants grown under light sources that lacked blue and UV-A wavelengths (660 and 660/735 LED arrays). In contrast, the number of colonies per leaf was highest and the mean colony diameters of S. fuliginea on cucumber plants were largest on leaves grown under the MH lamp (highest amount of blue and UV-A light) and least on leaves grown under the 660 LED array (no blue or UV-A light). The addition of far-red irradiation to the primary light source in the 660/735 LED array increased the colony counts per leaf in the S. fuliginea/cucumber pathosystem compared to the red-only (660) LED array. In the P. solanacearum/tomato pathosystem, disease symptoms were less severe in plants grown under the 660 LED array, but the effects of spectral quality on disease development when other wavelengths were included in the light source (MH-, 660/BF-, and 660/735-grown plants) were equivocal. These results demonstrate that spectral quality may be useful as a component of an integrated pest management program for future space-based controlled ecological life support systems.

NASA Center KSC↗

A preliminary summary of the observations of the 16 February 1984 solar flare (STIP Interval XV, 12-21 February 1984)

The solar flare on 16 Feb. 1984 (0900 UT) and the associated photon and particle emissions were perhaps the most interesting solar and interplanetary phenomena during STIP Interval XV, 12 to 21 Feb. 1984. The X-ray and microwave radio emissions, as observed from the Earth, were relatively weak and no optical flare was reported. However, the hard X-ray and low energy gamma-ray observations made with the Pioneer Venus Orbiter spacecraft behind the west limb of the Sun indicate that the flare was, in reality, very intense. There is evidence that the flare was located approx 40 deg behind the west limb of the Sun and hence, for instruments located near the Earth, the most intense parts of the X-ray and microwave radio sources were occulted by the photosphere. However, the effect of occultation on the metric type II, type III, and type IV and decimetric (type DCIM) radio sources appeared to be relatively small. Following the flare, a large increase in the counting rates was recorded by several ground level neutron monitors and energetic particle detectors located in interplanetary space. A preliminary analysis of the 16 Feb. 1984 flare observations follows.

Kane, S. R.↗

The Response of the BATSE LADs to Radiation From the Crab Nebula and Plans for Radioactivity Studies on Space Station

The Burst And Transient Source Experiment (BATSE) onboard the Compton Gamma-Ray Observatory (CGRO) was designed to measure X-rays and gamma rays with energies from about 50 keV to above 2 MeV. As with many scientific investigations, the success of the original experiment lead to additional areas of research interest. In the case of BATSE the ability to observe the radiation from sources down to about 20 keV became readily apparent. This lead to a continuing program of measuring the spectrum of radiation from stellar objects at these lower energies. One of these, the Crab Nebula, has a very steady radiation flux and, thus, has become a "standard candle" for such measurements. The Large Area Detectors (LADS) on BATSE contain a 1.27-cm thick, 25.4-cm radius NaI(Tl) detector behind a 6.35-mm thick polystyrene Charged Particle Detector (CPD) used to "veto" charged particles signals. The detectors have been calibrated with a series of gamma and X-ray sources and the results carefully simulated with a Monte Carlo code. In the calibration process the computer simulation accounts for scattering from material in the counting room as well as the BATSE structure. For an orbiting detector, scattering from the entire spacecraft must be modeled as well as for all covering material over the detectors. Five years after CGRO was launched on April 5, 1991, a large body of observational data has been taken of the Crab Nebula. The technique used for these observations, and for many other X-ray sources, is Earth occultation. From the perspective of the spacecraft, the Earth occults most stellar objects once in orbit, i.e., the signal is lost as the source sets and is regained as the source rises. A careful analysis of the continuing signals from all sources measured allows for an accurate measurement of the spectrum of a given source. An analysis of this data from the Crab has indicated that the LADs are very responsive at energies as low as 20 keV-at energies below the range of calibration. While the model accounts for many of the interactions of the photons with the detectors, the observation of nonstatistical deviations at low energy and at small angles has suggested a need to recalibrate at energies where the attenuation effects are increasing exponentially.

Laird, C. E.↗

Radon emanation rate measurements using liquid scintillation counting

This article describes a radon emanation measurement technique using liquid scintillator counting. A model for radon loading and transport is described, along with its calibration. Detector background and blank have been studied and quantified. The Minimal detectable activity has been determined for the counting setup using a toy Monte Carlo simulation. Here, the measurement technique is validated using a butyl rubber sample previously used for cross-calibration between different radon counting facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the detectability of the moving lens signal in CMB experiments

Abstract Upcoming cosmic microwave background (CMB) experiments are expected to detect new signals probing interaction of CMB photons with intervening large-scale structure. Among these the moving-lens effect, the CMB temperature anisotropy induced by cosmological structures moving transverse to our line of sight, is anticipated to be measured to high significance in the near future. In this paper, we investigate two possible strategies for the detection of this signal: pairwise transverse-velocity estimation and oriented stacking. We expand on previous studies by including in the analysis realistic simulations of competing signals and foregrounds. We confirm that the moving lens effect can be detected at ≥ 10σlevel by a combination of CMB-S4 and LSST surveys. We show that the limiting factors in the detection depend on the strategy: for the stacking analysis, correlated extragalactic foregrounds, namely the cosmic infrared background and thermal Sunyaev Zel'dovich effect, play the most important role. The addition of foregrounds make the signal-to-noise ratio be most influenced by large and nearby objects. As for the pairwise detection, halo lensing and pair number counts are the main issues. In light of our findings, we elaborate on possible strategies to improve the analysis approach for the moving lens detection with upcoming experiments. We also deliver to the community all the simulations and tools we developed for this study.

Astronomy & Astrophysics↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Sensitivity and uncertainty analysis of PWR spent fuel observables to operational and model parameters

Sensitivity and uncertainty analyses of spent nuclear fuel (SNF) observables - decay heat, neutron and γ-ray emission rate - to operational and model parameters have been performed. A 2D model representing a typical PWR 17x17 UO{sub 2} fuel assembly has been taken as reference. The Serpent code and ENDF/B-VII.1 evaluated nuclear data library have been used for the analyses. Relative uncertainty of decay heat, neutron and γ-ray emission rates due to Monte Carlo counting statistics, as well as the number of fuel pin radial regions required for an accurate characterization of SNF neutron emission, have been estimated. A parametric study has been carried out to investigate the impact of the homogenization to an average value of the fuel and moderator temperature, boron concentration power and burnup on the prediction of the selected observables. In addition, linear sensitivity coefficients have been calculated. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel Cascaded Ring Oscillator Vernier based TDC Architecture with a Feedthrough Reference Oscillator

Time to digital converters (TDCs) are widely used in particle physics and medical imaging to determine the relative arrival time of photons and other particles. Vernier TDCs are one of the most attractive options due to their power consumption efficiency and their small footprint. We present our newly patented innovative architecture of cascaded-stage Vernier TDCs comprised of a feedthrough reference oscillator. This architecture lead to successive Vernier measurements that result in a lower number of cycles for the same dynamic range to resolution ratio (DRRR), leading to reduced conversion time and lower jitter. To validate this architecture, a test chip was designed in 0.18~μm TSMC technology, integrating four types of cascaded Vernier TDCs with an increasing number of stages. The performance of the chip was assessed using a modular test platform specifically designed for TDCs. For comparison purposes, all TDCs were tested with a LSB of 50~ps and a dynamic range of 20~ns. The experimental results demonstrate the highest gain in performance between 1 stage Vernier and 2 stage Vernier TDCs with the precision improved from 36~ps~rms to 21~ps~rms, the maximum number of turns from 110 to 25 counts and the dead time, from 266.4~ns to 76.5~ns, on average. Adding Vernier stages is only relevant for a higher DRRR. Therefore, the 3-stage and 4-stage Vernier TDCs also show performance gains, but improvements are limited.

Scarpellini, Robin↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full 3D Kinetic Modeling and Quantification of Positive Streamer Evolution in an Azimuthally Swept Pin-to-Plane Wedge Geometry

Cathode-directed streamer evolution in near atmospheric air is modeled in 3D pin-to-plane geometries using a 3D kinetic Particle-In-Cell (PIC) code that simulates particle-particle collisions via the Direct Simulation Monte Carlo (DSMC) method. Due to the computational challenges associated with a complete 360° volumetric domain, a practical alternative was achieved using a wedge domain and a range of azimuthal angles was explored (5°, 15°, 30°, and 45°) to study possible effects on the streamer growth and propagation due to the finite wedge angle. A DC voltage of 6 kV is administered to a hemispherical anode of radius 100 μm, with a planar cathode held at ground potential, generating an over-volted state with an electric field of 4 MV/m across a 1500 μm gap. The domain is seeded with an initial ion and electron density of 10 18 m -3 at 1 eV temperature confined to a spherical region of radius 100 μm centered at the tip of the anode. The air chemistry model [1] includes standard Townsend breakdown mechanisms (electron-neutral elastic, excitation, ionization, attachment, and detachment collision chemistry and secondary electron emission) as well as streamer mechanisms (photoionization and ion-neutral collisions) via tracking excited state neutrals which can then either quench via collisions or spontaneously emit a photon based on specific Einstein-A coefficients [2, 3]. In this work, positive streamer dynamics are formally quantified for each wedge angle in terms of electron velocity and density as temporal functions of coordinates r, Φ, and z. Applying a random plasma seed for each simulation, particles of interest are tracked with near femtosecond temporal resolution out to 1.4 ns and spatially binned. This process is repeated six times and results are averaged. Prior 2D studies have shown that the reduced electric field, E/n, can significantly impact streamer evolution [4]. We extend the analysis to 3D wedge geometries, to limit computational costs, and examine the wedge angle’s effect on streamer branching, propagation, and velocity. Results indicate that the smallest wedge angle that produced an acceptably converged solution is 30°. The potential effects that a mesh, when under-resolved with respect to the Debye length, can impart on streamer dynamics and numerical heating were not investigated, and we explicitly state here that the smallest cell size was approximately 10 times the minimum λ D in the streamer channel at late times. This constraint on cell size was the result of computational limitations on total mesh count.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.

Porter, Frederick S.↗

Inferring the spatial and energy distribution of gamma-ray burst sources. 1: Methodology

We describe Bayesian methods for analyzing the distribution of gamma-ray burst peak photon fluxes and directions. These methods fit the differential distribution, and have the following advantages over rival methods: (1) they do not destroy information by binning or averaging the data (as do, say, chi squared, the averaged value of V/V(sub max), and angular moment analyses); (2) they straightforwardly handle uncertainties in the measured quantities; (3) they analyze the strength and direction information jointly; (4) they use information available about nondetections; and (5) they automatically identify and account for biases and selection effects given a precise description of the experiment. In these methods, the most important information needed about the instrument threshold is not its value at the times of burst triggers, as is used in the average value of V/V(sub max) analyses, but rather the value of the threshold at times when no trigger occurred. We show that this information can be summarized as an average detection efficiency that is similar to the product of the exposure and efficiency reported in the First Burst and Transient Source Experiment (BATSE) Burst (1B) Catalog, but significantly different from it at low fluxes. We also quantify an important bias that results from estimating the peak flux by scanning the burst to find the peak number of counts in a window of specified duration, as was done for the 1B Catalog. When the duration of the peak of the light curve is longer than the window duration, a simple flux estimate based on the peak counts significantly overestimates the peak flux in a nonlinear fashion that distorts the shape of the log(N)-log(P) distribution. This distortion also corrupts analyses of the V/V(sub max) distribution that use ratios of counts above background to estimate V/V(sub max). The Bayesian calculation specifies how to account for this bias. Implementation of the Bayesian approach requires some changes in the way burst data are reported that we describe in detail. Subsequent papers will report analyses of the 1B Catalog data using the methods described here.

Loredo, Thomas J.↗

Reprocessing Microflare Data

The report concerns work on detecting and cataloging solar microflares using an automated. An accompanying figure represents the solar microflare distribution during the period of April 1991 to November 1992, the height of solar activity after the launch of CGRO. It also shows the distribution extending below the distribution obtained at GSFC by manual means. We have implemented significant refinements in the search algorithm. The algorithm in its simplest form searches for transient events and based upon the distribution of the signal among the different BATSE detectors, we can assign it to be of solar origin if the signal distribution conforms to what one expects from a burst or transient from that direction. One of the major problems in an earlier effort was to search for microflares and large flares simultaneously. The requirement for a dynamic range of almost 10(exp 4) resulted in ambiguous identifications at the low side of the distribution. We have since restricted the search to events with peak count rates under 2000/s. Larger events are easily identified in the manual search, so we have chosen not to duplicate that work. The second problem was that missing counts existed below channel 0 in the BATSE Large Area Detector (LAD) data. These have been recovered and are now included in the search process. This provides data below 20 keV, and as we get closer to the thermal part of the spectrum, it provides greater sensitivity. The third problem was that too many BATSE detectors were used in the search. Detectors with pointing directions far from the Sun, although detecting the event, had poorly known responses. Detectors greater than approximately 60 degrees off the Sun are no longer included in the search process. By reducing the systematic errors with the large off-axis detectors we can conduct more rigorous statistical tests of a candidate event to ascertain whether it originated from the solar direction. We have reprocessed the period in the early mission that covers solar maximum and constructed the microflare distribution shown in the figure. The results of the automated search start to deviate from the manual search results below about 1000/s. Not only do we now have this distribution but we have a database of solar microflares that was used to construct the distribution. This database contains the signal at higher energy channels as well as that in channel zero (and below). From this one can, using software at GSFC, construct a photon spectrum for some of the larger microflares. It can also be used in other solar studies, especially those that correlate the X-ray flux with emission at other wavelengths. With some additional effort we hope to integrate this database into the corresponding one residing at the Solar Data Analysis Center at GSFC. The entire CGRO mission's data can now be reprocessed to obtain the microflare distribution at all phases of the solar cycle. This work is in progress. The results of this work will be presented in forthcoming scientific workshops and conferences.

Ryan, James M.↗