Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Prediction of neutron production and energy spectrum by the inverse kinematic reaction between an incident 7 Li 3+ beam and a proton target in PHITS

A neutron source using the inverse kinematic reaction between lithium and proton, p( 7 Li, n) 7 Be, achieves forward-directed neutrons, potentially enhancing neutron yield in the forward direction. Despite the advantage, no evaluated-cross-section data for this reaction can be used in Monte Carlo simulation codes, such as PHITS. To solve this problem, this study aims to evaluate the applicability of the user-defined cross-section data, Frag data, for p ( 7 Li, n) 7 Be in PHITS. The simulations reproduced collisions between 7 Li 3+ ions and polypropylene targets. The Frag data was edited based on the JENDL-5 by utilizing the two-body collision kinematics. The neutron yield and angular distribution were investigated in the simulation. As a result, the forward neutron convergence with a reasonable neutron yield and energy spectrum was observed. The expected neutron yield in the forward 1-steradian area is 2.46 × 10 10 n/s when lithium-ion energy and current are 16.45 MeV and 0.1 mA.

43 PARTICLE ACCELERATORS↗

Applications of compact accelerator-driven neutron sources: An updated assessment from the perspective of materials research in Italy

In 2005 the International Atomic Energy Agency (IAEA) in Vienna published a report [1] on ‘Development Opportunities of Small and Medium Scale Accelerator Driven Neutron Sources’ which summarized the prospect of smaller sources in supporting the large spallation neutron sources for materials characterization and instrumentation, a theme advocated by Bauer, Clausen, Mank, and Mulhauser in previous publications [2-4]. In 2010 the Union for Compact Accelerator-driven Neutron Sources (UCANS) was established [5], galvanizing cross-disciplinary collaborations on new source and neutronics development and expanded applications based on both slow-neutron scattering and other neutron-matter interactions of neutron energies ranging from 10⁻⁶ to 10² MeV [6]. Here, we first cover the recent development of ongoing and prospective projects of compact accelerator-driven neutron sources (CANS) but concentrate on prospective accelerators currently proposed in Italy. Two active R&D topics, irradiation effects on electronics and cultural heritage studies, are chosen to illustrate the impact of state-of-the-art CANS on these programs with respect to the characteristics and complementarity of the accelerator and neutronics systems as well as instrumentation development.

43 PARTICLE ACCELERATORS↗

A high-precision miniaturized rotating coil transducer for magnetic measurements

A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.

06.20.fb/calibration↗

A MHz-repetition-rate hard X-ray free-electron laser driven by a superconducting linear accelerator

The European XFEL is a hard X-ray free-electron laser (FEL) based on a high-electron-energy superconducting linear accelerator. The superconducting technology allows for the acceleration of many electron bunches within one radio-frequency pulse of the accelerating voltage and, in turn, for the generation of a large number of hard X-ray pulses. In this paper, we report on the performance of the European XFEL accelerator with up to 5,000 electron bunches per second and demonstrating a full energy of 17.5 GeV. Feedback mechanisms enable stabilization of the electron beam delivery at the FEL undulator in space and time. The measured FEL gain curve at 9.3 keV is in good agreement with predictions for saturated FEL radiation. Hard X-ray lasing was achieved between 7 keV and 14 keV with pulse energies of up to 2.0 mJ. Using the high repetition rate, an FEL beam with 6 W average power was created.

43 PARTICLE ACCELERATORS↗

Improved operation of the nonambipolar electron source

Significant improvements have been made to the nonambipolar electron source (NES), a radio frequency (rf) plasma-based electron source that does not rely on electron emission at a cathode surface [B. Longmier, S. Baalrud, and N. Hershkowitz, Rev. Sci. Instrum. 77, 113504 (2006)]. A prototype NES has produced 30 A of continuous electron current, using 2 SCCM (SCCM denotes cubic centimeter per minute at STP) Xe, 1300 W rf power at 13.56 MHz, yielding a 180 times gas utilization factor. A helicon mode transition has also been identified during NES operation with an argon propellant, using 15 SCCM Ar, 1000 W rf, and 100 G magnetic field. This NES technology has the ability to replace hollow cathode electron sources and to enable high power electric propulsion missions, eliminating one of the lifetime restrictions that many ion thrusters have previously been faced with.

43 PARTICLE ACCELERATORS↗

The use and characterization of a backilluminated charge-coupled device in investigations of pulsed x-ray and radiation sources

Examinations of bremsstrahlung and energetic electron beams from a novel laser plasma source motivate and assist characterization of a backthinned, backilluminated direct detection x-ray charge-coupled device (CCD), a topology that is uncommon in hard x-ray work. Behavior toward pseudomonochromatic ({sup 55}Fe) and multichromatic ({sup 241}Am) sources is briefly reviewed under optimized noise conditions. Results collectively establish the previously unknown functional depth structure. Several modes of usage are illustrated in {approx}4-20 keV x-ray laser plasma source investigations, where the significance of the characterization is briefly discussed. The spectral redistribution associated with this CCD topology is unfavorable, yet appropriate analysis ensures that sufficient spectral information remains for quantitative determination of broadband x-ray flux and spectra in essentially single laser shot measurements. The energy dependence of nascent electron cloud radii in silicon is determined using broadband x-rays from the laser plasma source, turning the narrow depletion depth to advantage. Finally, the characterization is used to quantify recent x-ray spectral explorations of the water jet laser plasma source operating under aspirator vacuum. These results will have key value for establishment of laboratory based ultrafast extended x-ray absorption fine structure experiments using microbolometric detectors.

43 PARTICLE ACCELERATORS↗

Sources for Low Energy Extreme of Ion Implantation

A joint research and development effort focusing on the design of steady state, intense ion sources has been in progress for the past four and a half years. The ultimate goal is to meet the two, energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. This endeavor has resulted in record steady state output currents of higher charge state Antimony and Phosphorous ions: P{sup 2+}(8.6 pmA), P{sup 3+}(1.9 pmA), and P{sup 4+}(0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. During the past year the effort was channeled towards low energy implantation, for which the effort involved molecular ions and a novel plasmaless/gasless deceleration method. To date, 3 emA of positive Decaborane ions were extracted at 14 keV and a smaller current of negative Decaborane ions were also extracted. Additionally, a Boron fraction of over 70% was extracted from a Bernas-Calutron ion source.

43 PARTICLE ACCELERATORS↗

Development of compact size penning ion source for compact neutron generator

For long-life operation, easy to mount and compact in size penning type ion sources are widely used in different fields of research such as neutron generators, material research, and surface etching. One penning type ion source has been developed in our laboratory. Applying high voltage of 2 kV between two oppositely biased electrodes and using permanent magnet of 500 gauss magnetic field along the axis, we had produced the glow discharge in the plasma region. The performance of this source was investigated using nitrogen gas. Deuterium ions were produced and extracted on the basis of chosen electrodes and the angle of extraction. Using a single aperture plasma electrode, the beam was extracted along the axial direction. The geometry of plasma electrode is an important factor for the efficient extraction of the ions from the plasma ion source. The extracted ion current depends upon the shape of the plasma meniscus. A concave shaped plasma meniscus produces converged ion beam. The convergence of extracted ions is related to the extraction electrode angle. The greater the angle, the more the beam converges. We had studied experimentally this effect with a compact size penning ion source. The detailed comparison among the different extraction geometry and different electrode angle are discussed in this paper.

43 PARTICLE ACCELERATORS↗

2E1 Ar{sup 17+} decay and conventional radioactive sources to determine efficiency of semiconductor detectors

Although reliable models may predict the detection efficiency of semiconductor detectors, measurements are needed to check the parameters supplied by the manufacturers, namely, the thicknesses of dead layer, beryllium window, and crystal active area. The efficiency of three silicon detectors has been precisely investigated in their entire photon energy range of detection. In the zero to a few keV range, we developed a new method based on the detection of the 2E1 decay of the metastable Ar{sup 17+} 2s{yields}1s transition. Very good theoretical knowledge of the energetic distribution of the 2E1 decay mode enables precise characterization of the absorbing layers in front of the detectors. In the high-energy range (>10 keV), the detector crystal thickness plays a major role in the detection efficiency and has been determined using a {sup 241}Am source.

43 PARTICLE ACCELERATORS↗

Measurement of the energy distribution of an intense electron beam in an external magnetic field

An energy analyzer device has been developed which utilizes a series of stacked foils and Rogowski current monitors to the measure time resolved current of an intense electron beam. The energy distribution of the electron beam is unfolded from measured current ratios using computer simulations. This device is particularly useful where electron beams are guided by external magnetic fields which may make other electron energy measurement techniques difficult. This technique was used to determine the energy distribution of a 550 keV, 95 kA electron beam as it propagates in the gas mixture of a high power KrF laser. The resulting energy distributions at various depths in the gas are in agreement with three-dimensional particle-in-cell simulations providing confidence in the measurement technique.

43 PARTICLE ACCELERATORS↗

A Fourier transform spectrometer without a beam splitter for the vacuum ultraviolet range: From the optical design to the first UV spectrum

We describe a Fourier transform (FT) spectrometer designed to operate down to 60 nm (20 eV) on a synchrotron radiation beamline for high resolution absorption spectrometry. As far as we know, such an instrument is not available below 140 nm mainly because manufacturing accurate and efficient beam splitters remains a major problem at these wavelengths, especially if a wide bandwidth operation is desired. In order to overcome this difficulty, we developed an interferometer based on wave front division instead of amplitude division. It relies on a modified Fresnel bimirror configuration that requires only flat mirrors. The instrument provides path difference scanning through the translation of one reflector. During the scanning, the moving reflector is controlled by an optical system that keeps its direction constant within a tolerable value and provides an accurate interferometric measurement of the path difference variation. Therefore, a regular interferogram sampling is obtained, producing a nominal spectral impulse response and an accurate spectral calibration. The first results presented in this paper show a measured spectral resolution of {delta}{sigma}=0.33 cm{sup -1} (interval between spectral samples). This was obtained with a sampling interval of 29 nm (path difference) and 512 K samples from a one-sided interferogram using a cosine FT. Such a sampling interval should allow the recording of large bandwidth spectra down to {lambda}=58 nm with an ultimate resolving power of 500 000 at this wavelength. In order to check the instrument performances, we first recorded an interferogram from a He-Ne stabilized laser. This provided the actual spectral impulse function, which was found to be fully satisfactory. The determination of the impulse response distortion and of the noise on the vacuum ultraviolet (VUV) spectral range provided accurate information in the sampling error profile over a typical scan. Finally, the instrument has been moved to the SU5 undulator-based synchrotron radiation beamline (Super-ACO facility, LURE, Orsay, France). A high resolution spectrum of O{sub 2} (the Schumann-Runge absorption bands, 185-200 nm) was computed from recorded interferograms using the beamline monochromator at the zeroth order to feed the instrument with an 11% relative bandwidth ''white'' beam (2003). These UV measurements are very close to those found in the literature, showing nominal performances of the FT spectrometer that should translate into an unprecedented resolving power at shortest VUV wavelengths. A recent upgrade (2007) and future developments will be discussed in light of the current installation of the upgraded FT spectrometer as a permanent endstation for ultrahigh resolution absorption spectrometry on the VUV beamline DESIRS at SOLEIL, the new French third generation synchrotron facility.

43 PARTICLE ACCELERATORS↗

Characteristics of rf H{sup -} Ion Source by Using FET Power Source

Characteristics of radio frequency(rf) plasma production are investigated using a FET inverter power supply as an rf generator. The matching circuit in the inverter system is simple compared to a conventional 50 Ohm matching system and only an imaginary part of the impedance of rf transmission should be matched by adjusting operating frequency or capacitance of the circuit. An electron density over 10{sup 18} m{sup -3} is produced in argon plasma with 1 kW rf power. Lower densities are obtained in helium and hydrogen plasmas compared to the argon plasma. Effect of axial magnetic field in driver region is examined. Electron density more than 10{sup 18} m{sup -3} is obtained at the hydrogen gas pressure around 1 Pa with the help of the axial magnetic field.

43 PARTICLE ACCELERATORS↗

Quantitative Determination of Deuterium Atom Concentration in Zinc Oxide Thin Films by Time-of-Flight Secondary Ion Mass Spectrometry

ZnO is a wide-gap semiconductor with very interesting electronic properties.[1,2] Therefore, it has been extensively studied for many years. It has been found that even low centrations of hydrogen in ZnO film can considerably change its electronic behavior.[3-5] Quite a few papers have discussed this issue but it has not been fully understood. Lack of experimental data, especially quantitative data on hydrogen concentration in ZnO samples is an important reason. Dynamic SIMS is the best technique to determine concentration of hydrogen atoms in materials.[6-9] However, it is a very specific technique and the entation is mostly available in semiconductor industry. ToF-SIMS is a more versatile instrument and it is more available in universities and research institutes. Background hydrogen interference has been known to be a serious problem in quantifying hydrogen atoms in solid samples. Although SIMS is an ultra-high vacuum (UHV) technique, there are still some residual gases existing in vacuum chambers during analysis. Most of them are H2, H2O or CH4, which lead to a background that greatly interferes quantitative detection of hydrogen. Therefore, deuterium atoms have been intentionally introduced into the system to avoid this problem. Standard samples are very important for SIMS quantitative analysis. A common method to prepare such kind of standard samples is ion-implanting. Therefore, a set of standard D-ZnO samples were prepared by ion-implanting in our work. In this paper, we report using ToF-SIMS to quantitatively determine the concentration of deuterium atoms in a number of high-quality epitaxial ZnO films, with a set of standard samples as references. We are especially interested in the detection limit of deuterium concentration in ZnO. In addition, hydrogen background interference was also investigated.

08 HYDROGEN↗

A compact electron beam ion source with integrated Wien filter providing mass and charge state separated beams of highly charged ions

A Wien filter was designed for and tested with a room temperature electron beam ion source (EBIS). Xenon charge state spectra up to the charge state Xe{sup 46+} were resolved as well as the isotopes of krypton using apertures of different sizes. The complete setup consisting of an EBIS and a Wien filter has a length of less than 1 m substituting a complete classical beamline setup. The Wien filter is equipped with removable permanent magnets. Hence total beam current measurements are possible via simple removal of the permanent magnets. In dependence on the needs of resolution a weak (0.2 T) or a strong (0.5 T) magnets setup can be used. In this paper the principle of operation and the design of the Wien filter meeting the requirements of an EBIS are briefly discussed. The first ion beam extraction and separation experiments with a Dresden EBIS are presented.

43 PARTICLE ACCELERATORS↗

Cold-target recoil-ion momentum spectroscopy for diagnostics of high harmonics of the extreme-ultraviolet free-electron laser light source at SPring-8

We have developed a cold-target recoil-ion momentum spectroscopy apparatus dedicated to the experiments using the extreme-ultraviolet light pulses at the free-electron laser facility, SPring-8 Compact SASE Source test accelerator, in Japan and used it to measure spatial distributions of fundamental, second, and third harmonics at the end station.

43 PARTICLE ACCELERATORS↗

Production and ion-ion cooling of highly charged ions in electron string ion source

The scheme of an internal injection of Au atoms into the working space of the ''Krion-2'' electron string ion source (ESIS) was applied and tested. In this scheme Au atoms are evaporated from the thin tungsten wire surface in vicinity of the source electron string. Ion beams with charge states up to Au{sup 51+} were produced. Ion-ion cooling with use of C and O coolant ions was studied. It allowed increasing of the Au{sup 51+} ion yield by a factor of 2. Ions of Kr up to charge state 28+ were also produced in the source. Electron strings were first formed with injection electron energy up to 6 keV. Methods to increase the ESIS ion output are discussed.

43 PARTICLE ACCELERATORS↗

Emittance characterization of a hot-cavity laser ion source at Holifield Radioactive Ion Beam Facility

The first investigation of the transverse emittance of a hot-cavity laser ion source based on all-solid-state Ti:sapphire lasers is presented. The emittances of {sup 63}Cu ion beams generated by three-photon resonant ionization are measured and compared with that of the {sup 69}Ga and {sup 39}K ion beams resulting from surface ionization in the same ion source. A self-consistent unbiased elliptical exclusion method is adapted for noise reduction and emittance analysis. Typical values of the rms and 90% fractional emittances of the Cu ion beams at 20 keV energy are found to be about 2 and 8 {pi} mm mrad, respectively, for the ion currents of 2-40 nA investigated. The emittances of the laser-produced Cu ion beams are smaller than those of the surface-ionized Ga and K ion beams.

43 PARTICLE ACCELERATORS↗

An improved high intensity recycling helium-3 beam source

We describe an improved high intensity, recycling, supersonic atomic beam source. Changes address several issues previously limiting performance and reliability of the apparatus, including the use of newly available vacuum pumps and modifications to the recycling system. We achieve a source intensity of 2.5x10{sup 19} atoms/s/sr, almost twice that previously achievable during recycling. Current limits on intensity are discussed.

43 PARTICLE ACCELERATORS↗