Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PUBLIC SERVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

1995 OKI Household Activity and Travel Report Survey

The OKI Household Activity and Travel Report Survey 1995, conducted by Market Opinion Research, gathered household activity and travel data from 3,000 households within the OKI region (Ohio, Kentucky, and Indiana Council of Governments' service area). The region covers over 2,615 square miles and is home to 697,468 households (over 1.75 million people). The primary purpose of this study was to provide OKI with a new database of travel patterns and behavior to assist in updating the region's transportation models. Respondents were asked to report their activities for a 24-hour period from 3:00 a.m. to 3:00 a.m. on an assigned activity day. The survey included weekday assignments only from October 4, 1995, to November 30, 1995.

1Hz data↗

Transit Rider/Travel Behavior Inventory Survey - Minneapolis-St. Paul Metro - 2005

The survey was an on-board survey of transit riders on all regular route services for bus and light-rail in the Minneapolis-Saint Paul metropolitan area. The primary purpose of the study was to gather the data needed to update the mode choice models that are an integral component of the regional travel forecast model maintained by the Metropolitan Council, the metropolitan planning organization for the Minneapolis-Saint Paul metropolitan area. The survey instrument focused on identifying characteristics of the trip taken by each transit rider, including origin, destination, trip purpose, and mode of access. The survey also collected relevant socioeconomic and demographic information.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗

Transition to Online Cable Insulation Condition Monitoring

Nuclear power plant cables were originally qualified for 40 year life and generally have not required specific test verification to assure service availability through the initial plant qualification period. However, license renewals to 60 and 80 years of operation require a cable aging management program that depends on some form of test and verification to assure fitness for service. Environmental stress (temperature, radiation, chemicals, water, and mechanical) varies dramatically within a nuclear power plant and, in some cases, cables have degraded and required repair or replacement before their qualified end-of-life period. In other cases, cable conditions have been mild and dependable cable performance confirmed to extend well beyond the initial qualified life. Most offline performance-based testing requires cables to be de-coupled and de-energized for specially trained technicians to perform testing. These offline tests constitute an expensive operational burden that limits the economic viability of nuclear power plants. Although initial investment may be higher, new online test practices are emerging as options or complements to offline testing that avoid or minimize the regularly scheduled offline test burden. These online methods include electrical and fiber-optic partial discharge measurement, spread spectrum time or frequency domain reflectometry, distributed temperature profile measurements, and local interdigital capacitance measurement of insulation characteristics. Introduction of these methods must be supported by research to confirm efficacy plus either publicly financed or market driven investment to support the start-up expense of cost-effective instrumentation to monitor cable condition and assure reliable operation. This work summarizes various online cable assessment technologies plus introduces a new cable motor test bed to assess some of these technologies in a controlled test environment.

Glass, Samuel W.↗

Los Alamos National Laboratory Floodplain Assessment for the Technical Area 8 to Technical Area 22 Natural Gas Line Replacement Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction that crosses through upper Pajarito Canyon and upper Starmer Canyon from Technical Area (TA) 8 to TA-22 at Los Alamos National Laboratory (LANL). The project proposes to install a new 12 inch natural gas line to replace the existing 70+ year old natural gas line. Replacement will prevent loss of service to several LANL TAs and Bandelier National Monument. The project activities within the 100- year floodplains include 1) new natural gas line installation to replace and existing aging gas line, 2) relocating a section of fence and 3) three construction equipment and materials storage areas. NNSA has prepared this floodplain assessment in accordance with 10 Code of Federal Regulations (CFR) Part 1022 Compliance with Floodplain and Wetland Environmental Review Requirements (10 CFR Part 1022) (CFR 2003) which was promulgated to implement DOE requirements under Executive Order 11988 Floodplain Management (EO 1977). A floodplain is defined in 10 CFR 1022 as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands,” and a base floodplain as “the 100-year floodplain, that is, a floodplain with a 1.0 percent chance of flooding in any given year (CFR 2003).” This floodplain assessment evaluates potential impacts to floodplain values and functions from implementation of the proposed action, identifies alternatives to the Proposed Action, and allows for meaningful public comment.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Stewardship Optimization for a Decommissioned Nuclear Reactor - 19579

The decommissioned Hallam Nuclear Power Facility (Hallam), located in Lancaster County, Nebraska, approximately 19 miles south of Lincoln, was developed as a prototype to investigate the technical and economic feasibility of a sodium-cooled, graphite-moderated nuclear reactor. As part of its Power Demonstration Program, the US Atomic Energy Commission (US AEC), a predecessor agency of the US Department of Energy (US DOE), operated the Hallam reactor from 1962 to 1964. The radiological surveillance of the Hallam site was established when the operating agreement between AEC and the Nebraska Public Power District was terminated. The US DOE Chicago Operations Office and the Nebraska Department of Health (NDH) agreed to install a shallow groundwater monitoring system as part of the environmental surveillance program. Surveillance at the site was scheduled to end in fiscal year 2005, with no further activities planned after that. At that time, the plan was to transition the site to the Nebraska Public Power District with future use of the facility to remain restricted. US DOE has title to and responsibility for the entombed radioactive materials. A surveillance and monitoring program was initiated in 1970 by NDH and was funded by US AEC. It included the analysis of samples from deep production wells (groundwater from the regional aquifer at depths greater than 55 meters [180 feet]) at the Sheldon Station. NDH was concerned in 1990 about the possibility of shallow groundwater coming in contact with the buried radiological materials along the buried walls of the reactor. Subsequently, DOE and NDH agreed to further characterize hydrologic conditions and establish a monitoring program in the shallow, perched groundwater zones. The current monitoring program focuses on the shallow, perched groundwater. Today, decades since facility decommissioning, site inspections and groundwater monitoring continue at this Cold War-era legacy site. The US DOE Office of Legacy Management (LM) monitors groundwater as a best management practice in response to a request from the Nebraska Department of Health and Human Services (DHHS). In 2006, LM recommended discontinuing groundwater monitoring because analytical results since 1970 demonstrated there had been no impact to shallow, perched groundwater and no current or anticipated unacceptable risk to human health and the environment. The State of Nebraska did not concur with the recommendation to stop monitoring but did agree to a reduction in sampling and analysis from once a year to once every 2 years--a schedule that began in 2008. An updated assessment of the groundwater monitoring effort was issued in 2016. The entire body of water-quality data continues to demonstrate that there have been no negative impacts to the shallow, perched groundwater from radioactive materials entombed at the site 46 years ago. LM, with concurrence from Nebraska DHHS, changed the sampling frequency, effective in 2018, as follows: once every 5 years from 2021 to 2041 and once every 10 years from 2041 to 2071. In summary, LM remains committed to its primary mission to protect human health and the environment at each of its 92 legacy sites. With results from groundwater sampling events demonstrating compliance for 48 years, the Hallam site was able to set an LM benchmark to optimize long-term stewardship and define an end-state strategy for other decommissioned reactor facilities across the DOE complex. Continued collaboration with local communities, stakeholder, and regulators often leads to outcomes of sound protectiveness without compromise to safety or compliance, as demonstrated by the optimization of the long-term stewardship at the Hallam site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Olkiluoto 1 and 2 - Plant efficiency improvement and lifetime extension-project (PELE) implemented during outages 2010 and 2011

Teollisuuden Voima Oyj (TVO) is a non-listed public company founded in 1969 to produce electricity for its stakeholders. TVO is the operator of the Olkiluoto nuclear power plant. TVO follows the principle of continuous improvement in the operation and maintenance of the Olkiluoto plant units. The PELE project (Plant Efficiency Improvement and Lifetime Extension), mainly completed during the annual outages in 2010 and 2011, and forms one part of the systematic development of Olkiluoto units. TVO maintains a long-term development program that aims at systematically modernizing the plant unit systems and equipment based on the latest technology. According to the program, the Olkiluoto 1 and Olkiluoto 2 plant units are constantly renovated with the intention of keeping them safe and reliable, The aim of the modernization projects is to improve the safety, reliability, and performance of the plant units. PELE project at Olkiluoto 1 was done in 2010 and at Olkiluoto 2 in 2011. The outage length of Olkiluoto 1 was 26 d 12 h 4 min and Olkiluoto 2 outage length was 28 d 23 h 46 min. (Normal service-outage is about 14 days including refueling and refueling-outage length is about seven days. See figure 1) The PELE project consisted of several single projects collected into one for coordinated project management. Some of the main projects were as follows: - Low pressure turbines: rotor, stator vane, casing and turbine instrumentation replacement. - Replacement of Condenser Cooling Water (later called seawater pumps) pumps - Replacement of inner isolation valves on the main steam lines. - Generator and the generator cooling system replacement. - Low voltage switchgear replacement. This project will continue during future outages. PELE was a success. 100 TVO employees and 1500 subcontractor employees participated in the project. The execution of the PELE projects went extremely well during the outages. The replacement of the low pressure turbines and seawater pumps improved the efficiency of the plant units, and a power increase of nearly 20 MW was achieved at both plant units. PELE wonderfully manifests one of the strategic goals of our company; developing the competence of our in-house personnel by working in projects. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Automating Natural Disaster Impact Analysis: An Open Resource to Visually Estimate a Hurricane s Impact on the Electric Grid

An ORNL team working on the Energy Awareness and Resiliency Standardized Services (EARSS) project developed a fully automated procedure to take wind speed and location estimates provided by hurricane forecasters and provide a geospatial estimate on the impact to the electric grid in terms of outage areas and projected duration of outages. Hurricane Sandy was one of the worst US storms ever, with reported injuries and deaths, millions of people without power for several days, and billions of dollars in economic impact. Hurricane advisories were released for Sandy from October 22 through 31, 2012. The fact that the geoprocessing was automated was significant there were 64 advisories for Sandy. Manual analysis typically takes about one hour for each advisory. During a storm event, advisories are released every two to three hours around the clock, and an analyst capable of performing the manual analysis has other tasks they would like to focus on. Initial predictions of a big impact and landfall usually occur three days in advance, so time is of the essence to prepare for utility repair. Automated processing developed at ORNL allowed this analysis to be completed and made publicly available within minutes of each new advisory being released.

EARSS↗

The Potential Role of Concentrating Solar Power within the Context of DOE's 2030 Solar Cost Targets

To continue the momentum for cost reduction in solar technologies, DOE recently established 2030 cost targets for that would make solar one of the lowest-cost sources of new electricity in the United States. The potential impacts of achieving the 2030 cost targets for solar photovoltaics (PV) were recently explored in a related publication, which found significant potential for solar PV deployment and generation, particularly when coupled with low-cost storage. Building on this previous report, the present analysis evaluates the potential impacts of simultaneously achieving the 2030 cost targets for both PV and concentrating solar power with thermal energy storage (CSP-TES) systems in the contiguous United States, with a detailed evaluation of the role that CSP-TES plays in realizing those impacts. The evolution of the contiguous U.S. electricity system is evaluated with NREL's Renewable Energy Deployment System (ReEDS) model, which has been specifically designed to represent the time and locational value of renewable generation technologies in the U.S. power system. This analysis suggests achievement of the SunShot cost targets for CSP-TES might lead to dramatic growth in CSP-TES capacity, with accelerated deployment after the 2030 target is achieved. Based on our representation of the 2030 cost targets in ReEDS, economically-competitive CSP-TES could primarily be deployed in a dispatch able, high-capacity factor configuration, which allows it to provide valuable services to the power sector and results in a generation profile for CSP-TES that is complementary to that of variable PV. Aggressive cost reductions for CSP-TES could also make such a configuration economically competitive across the contiguous United States, which is a a result that warrants additional analysis in terms of potential siting, permitting, regulatory, and construction challenges in these new regions and markets. The modeled capacity expansion of both CSP-TES and PV in our scenarios that achieve the 2030 cost targets requires most growth in transmission capacity at a pace that is consistent with historical buildout rates, and could result in reduced electricity prices and power system costs, water usage, and air emissions. Finally, sensitivity analysis suggests that the cumulative capacity and geographic extent of CSP-TES deployment in our low-cost solar scenarios is highly sensitive to the post-2030 cost reductions for CSP-TES and future price of natural gas, and that significant competition exists among renewable energy and energy storage technologies, assuming aggressive cost reductions for each. For example, significant competition between CSP-TES and PV with battery storage indicates the similar role that these systems play in capacity planning and grid operations, as well as the fact that low-cost battery storage would help improve the capacity value of low-cost PV into the future.

14 SOLAR ENERGY↗

DOE EV Data Collection - Maintenance Data

Maintenance data includes information on maintenance performed on the electric vehicles, including preventive maintenance, service calls, and availability of the vehicles. The parameters collected, and their definitions, will vary due to the differences in maintenance tracking systems that exist between fleets. Parameter definitions are detailed in the data dictionary, and specific vehicle information is available in the vehicle attributes table. Vehicle ID can be used as a key between maintenance data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental High Energy Physics Research

This final report summarizes activities of the Florida Tech High Energy Physics group supported by DOE under grant #DE-SC0008024 during the period June 2012 – March 2015. We focused on one of the main HEP research thrusts at the Energy Frontier by participating in the CMS experiment. We were exploiting the tremendous physics opportunities at the Large Hadron Collider (LHC) and prepared for physics at its planned extension, the High-Luminosity LHC. The effort comprised a physics component with analysis of data from the first LHC run and contributions to the CMS Phase-2 upgrades in the muon endcap system (EMU) for the High-Luminosity LHC. The emphasis of our hardware work was the development of large-area Gas Electron Multipliers (GEMs) for the CMS forward muon upgrade. We built a production and testing site for such detectors at Florida Tech to complement future chamber production at CERN. The first full-scale CMS GE1/1 chamber prototype ever built outside of CERN was constructed at Florida Tech in summer 2013. We conducted two beam tests with GEM prototype chambers at CERN in 2012 and at FNAL in 2013 and reported the results at conferences and in publications. Principal Investigator Hohlmann served as chair of the collaboration board of the CMS GEM collaboration and as co-coordinator of the GEM detector working group. He edited and authored sections of the detector chapter of the Technical Design Report (TDR) for the GEM muon upgrade, which was approved by the LHCC and the CERN Research Board in 2015. During the course of the TDR approval process, the GEM project was also established as an official subsystem of the muon system by the CMS muon institution board. On the physics side, graduate student Kalakhety performed a Z' search in the dimuon channel with the 2011 and 2012 CMS datasets that utilized 20.6 fb⁻¹ of p-p collisions at √s = 8 TeV. For the dimuon channel alone, the 95% CL lower limits obtained on the mass of a Z' resonance are 2770 GeV for a Z' with the same standard-model couplings as the Z boson. Our student team operated a Tier-3 cluster on the Open Science Grid (OSG) to support local CMS physics analysis and remote OSG activity. As a service to the HEP community, Hohlmann participated in the Snowmass effort over the course of 2013. Specifically, he acted as a liaison for gaseous detectors between the Instrumentation Frontier and the Energy Frontier and contributed to five papers and reports submitted to the summer study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting Switchgrass Biomass Yields Using a Spectral Vegetation Index Derived from Multispectral Satellite Imagery

Successful scaling of perennial bioenergy crop production requires a landscape design that optimizes the benefits of finite lands for people, communities, and environments. Utilizing marginal areas is the key to sustainable bioenergy crop production (Ssegane et al., 2015, 2016). Marginal areas are often small-sized lands and unevenly distributed across the agricultural landscape (Ssegane et al., 2016); thus, a systematic, semi-automated remote sensing method is needed as an effective means of estimating bioenergy crop yields across landscapes. Argonne National Laboratory (Argonne) is currently developing a tool, Scaling Up Perennial Bioenergy Economics and Ecosystem Services Tool (SUPERBEEST), to identify marginal agricultural lands and quantify environmental and economic effects of perennial bioenergy crop production systems. The tool aims to provide users a path to foster the sustainable and productive integration of bioenergy crops in the Midwestern agricultural landscape. Reliable, cost-effective, and timely estimation of bioenergy crop yields using remote sensing would help calculate and track the success of integrated bioenergy crops in the landscape for those communities. Argonne previously conducted feasibility studies for estimating biomass yields for bioenergy feedstock, corn and perennial grass using spectral vegetation indices (SVIs)1 derived from optical imagery (Hamada et al., 2015, 2021). In both studies, SVIs, more specifically those sensitive to plant chlorophyll or nitrogen contents, showed potential for estimating or predicting biomass yields with a correlation of determination (R2) ranging from 0.54 to 0.96, indicating a value for further investigation as a viable means of quantifying bioenergy feedstock production across large landscapes. Thus, the goal of this study is to evaluate the feasibility of use of SVIs as a means of estimating or predicting switchgrass biomass yields at harvest using publicly available multispectral satellite imagery. The feasibility analysis was performed using four study areas of mature switchgrass located in Virginia. Objectives are to (1) examine the SVIs and establish their relationships with switchgrass biomass yields at harvest, (2) develop a parsimonious image processing model for predicting at-harvest yields by applying the relationships with the most promising spectral index and (3) map switchgrass yields predicted by the image processing model across the study sites. The calibration to field data will rely on switchgrass biomass yields determined by the baling method, representing a potential challenge to the analysis but an important practical aspect for future applications. With this research design, the study aimed to gain insights into enabling remote sensing-based estimation of bioenergy crop yields in a reliable, cost- effective, and timely manner across large, heterogeneous landscapes.

09 BIOMASS FUELS↗

Fate of Listeria monocytogenes Serotypes on Frozen Mixed Vegetables During Consumer‐Simulated Thawing and Storage

ABSTRACT Recent outbreaks and recalls associated with frozen vegetables in the United States and Europe have been linked to Listeria monocytogenes . This study aims to understand the extent to which frozen vegetables support the growth of L. monocytogenes once thawed and held at different temperatures. Six L. monocytogenes strains, two of each from serotypes 1/2a, 1/2b, and 4b, were individually inoculated onto frozen vegetables and stored at −18°C for 7 days. After 7 days, the vegetables were thawed and stored at 5°C or 10°C for up to 14 days or at 25°C for up to 7 days. L. monocytogenes was enumerated from the thawed vegetables throughout the storage period. Population data were fitted to the primary Baranyi model to estimate growth rates and lag phase durations; the secondary Ratkowsky square root model was used to model the relationship of the growth rates with storage temperature. Five of the L. monocytogenes strains survived and grew on the thawed vegetables (population increases of > 1 log CFU/g) stored at 5°C, and all six of the strains proliferated at 10°C and 25°C (population increases of > 3 log CFU/g after 14 days and > 4 log CFU/g after 7 days, respectively). A secondary model was successfully generated based on the growth rates of the six L. monocytogenes strains on the thawed vegetables ( r 2 = 0.8888, RMSE = 0.2057). Results from this study fill a data gap associated with L. monocytogenes survival on thawed vegetables and can be used to determine safe handling and storage practices for these products to protect public health.

Salazar, Joelle K. [Division of Food Processing Sc↗

FleetREDI Insight: Intrastate Coach Bus Dataset

Capturing real-world data is critical to improving efficiency and supporting technology advancements in commercial vehicles. FleetREDI’s insights provide detailed duty cycle information and highlight unique aspects of the given dataset. Each insight delivers a quick look at the collected data by summarizing the operation and identifying key findings of the initial analysis. This FleetREDI insight explores coach buses operating in Colorado. Coach buses are a primary mover for intrastate transit and are primarily used for longer trips with more comfortable seats and a restroom. All Aboard America! Holdings Inc. offers various fixed-service and charter routes across Colorado on its Bustang fleet out of its depot in Golden, Colorado. NLR installed logging devices and collected operational data on nine 40-foot Bustang motorcoaches operating on fixed routes from May through August 2022. Using NLR’s FleetREDI data platform, this dataset provides a summary of daily operation to help understand duty cycle characteristics. This includes daily distance, fuel use, and estimated engine-produced energy consumption for nine motorcoaches that operated more than 33,000 miles. These vehicles primarily operated on Interstate 25 and Interstate 70. ![FleetREDI interstate bus](FleetREDI-interstate-bus.jpg)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Perceptions of Seasonal Influenza Vaccine Among U.S. Army Civilians and Dependents in the Kaiserslautern Military Community: A Mixed-Methods Survey

ABSTRACT Introduction Influenza is a globally occurring viral respiratory infection that can lead to hospitalizations and death. An influenza outbreak can interfere with combat readiness in a military setting, as the infection can incapacitate soldiers. Vaccination remains the most effective tool to prevent and mitigate seasonal influenza. Although influenza vaccinations for U.S. Army soldiers can be monitored through military health systems, those systems cannot capture DoD civilians and Army dependents who may not use military health services. This study aims to gauge flu vaccine uptake and perceptions in U.S. Army civilians and dependents. Materials and Methods An online survey was e-mailed to civilian and dependent enrollees of Landstuhl Regional Medical Center. The survey contained 24 questions pertaining to demographics, vaccine history, history of the flu, and beliefs toward vaccines. Chi-square tests, t-tests, and logistic regressions were performed to investigate the association between demographic, behavior, and belief factors with vaccine uptake. Free-text answers were coded and categorized by themes. Results Over 70% of respondents were vaccinated for the flu. There were differences between vaccinated and unvaccinated respondents regarding their perceptions of barriers to vaccination, benefits of the flu vaccine, severity of flu symptoms, and personal risk of getting ill with the flu. After controlling for confounders, flu vaccination in the previous season and healthcare worker status were associated with increased vaccine uptake, while perceived barriers to influenza vaccination were associated with decreased vaccine uptake. Conclusions Flu vaccine uptake may be increased by increasing access to vaccination, promoting vaccination and addressing concerns at the provider level, and engaging positively framed public messaging. Increasing flu vaccine uptake is of particular importance as the flu season approaches during the COVID-19 (Coronavirus disease 2019) pandemic.

Burns, MSC, Veronica M.↗

PoroTomo Natural Laboratory Horizontal and Vertical Distributed Acoustic Sensing Data

This dataset includes links to the PoroTomo DAS data in both SEG-Y and hdf5 (via h5py and HSDS with h5pyd) formats with tutorial notebooks for use. Data are hosted on Amazon Web Services (AWS) Simple Storage Service (S3) through the Open Energy Data Initiative (OEDI). Also included are links to the documentation for the dataset, Jupyter Notebook tutorials for working with the data as it is stored in AWS S3, and links to data viewers in OEDI for the horizontal (DASH) and vertical (DASV) DAS datasets. Horizontal DAS (DASH) data collection began 3/8/16, paused, and then started again on 3/11/2016 and ended 3/26/2016 using zigzag trenched fiber optic cabels. Vertical DAS (DASV) data collection began 3/17/2016 and ended 3/28/16 using a fiber optic cable through the first 363 m of a vertical well. These are raw data files from the DAS deployment at (DASH) and below (DASV) the surface during testing at the PoroTomo Natural Laboratory at Brady Hot Spring in Nevada. SEG-Y and hdf5 files are stored in 30 second files organized into directories by day. The hdf5 files available via HSDS are stored in daily files. Metadata includes information on the timing of recording gaps and a file count is included that lists the number of files from each day of recording. These data are available for download without login credentials through the free and publicly accessible Open Energy Data Initiative (OEDI) data viewer which allows users to browse and download individual or groups of files.

15 GEOTHERMAL ENERGY↗

SPRUCE Porewater Chemistry Data for Experimental Plots, Beginning in 2013, Version 4

This data set includes the chemistry of porewater in the SPRUCE experiment plots located in the S1 bog of the USDA Forest Service Marcell Experimental Forest (MEF) in northern Minnesota, 40 km north of Grand Rapids. Data are presented from June 2013 through September 2020 (2013-06-28 to 2020-09-28). Data will continue to be collected until 2025 and will be appended to this dataset periodically. These data are the pre- and post-treatment data from the warming and elevated carbon dioxide (CO2) treatments associated with the SPRUCE experiment. There are 10 experimental plots in SPRUCE: 5 temperature treatments (+0, +2.25, +4.5, +6.75, +9°C) at ambient CO2, and the same 5 temperature treatments at elevated CO2 (+500 ppm). There are 7 additional ambient plots without experimental enclosures, and thus a total of 17 plots. Water samples were analyzed for pH, specific conductivity, nutrient concentrations (ammonium, nitrate, soluble reactive phosphorus, total nitrogen, total phosphorus), cation concentrations (calcium, potassium, magnesium, sodium, aluminum, iron, manganese, silicon, strontium), anion concentrations (chloride, sulfate), and TOC concentrations. Subsets of the samples were analyzed for natural-abundance stable isotopes of water (δ18O-H2O and δD-H2O) and THg and MeHg concentrations. User note: Results will be added to this data set and released to the public periodically as quality assurance and publication of results are accomplished. This June 2024 release (Version 4) is an updated and expanded version that supersedes and replaces the previous release. See the Data Release History table below for additional release notes.

54 ENVIRONMENTAL SCIENCES↗

EVI-LOCATE User Manual

One of the longest stages in the deployment of electric vehicle supply equipment (EVSE) is the initial planning of the infrastructure itself. Engineers and fleet experts from the National Renewable Energy Laboratory (NREL) have supported dozens of charging infrastructure site plans over the past couple decades, including the generation of site schematics, determinations of electric capacity, and estimates for likely costs. As the market for electric vehicles (EVs) has matured, this approach should no longer require a time and personnel intensive process. In order to shorten the time taken to develop site plans and cost estimates, NREL developed a tool that fleet managers, facility managers, electricians, EVSE installers, and members of the public can use to develop initial schematics and ballpark pricing for charging station installations. The Electric Vehicle Infrastructure - Locally Optimized Charger Assessment Tool and Estimator (EVI-LOCATE) provides a structured and consistent way for users to enter information about their planned EVSE project in a relatively simple web-based format. EVI-LOCATE then calculates electrical equipment capacity, wiring runs, and project costs. It produces a site diagram optimized around surface characteristics with differential trenching costs for softscape such as grass compared to hardscape such as asphalt that can be adjusted by users in the tool. It also stores the resulting site plans and costs in a dashboard for access at a later date, including plan revisions if necessary. This document guides users through the EVI-LOCATE screens and associated questions. It contains tip text boxes throughout on how best to interface with the tool and find additional information or context. The appendices contain the assumptions and calculations underpinning the tool. Much of the information for EVI-LOCATE was gathered through industry engagements with EVSE installers, invoices from completed EVSE installations, Gordian's RS Means construction data, and the General Services Administration blanket purchase agreement for EVSE. For a visual tutorial of the tool, users can watch EVI-LOCATE Step-by-Step Video. The tool itself is available at https://evi-locate.nrel.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗