Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLYNOMIALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Bounce cosmology from F(R) gravity and F(R) bigravity

We reconstruct F(R) gravity models with exponential and power-law forms of the scale factor in which bounce cosmology can be realized. We explore the stability of the reconstructed models with analyzing the perturbations from the background solutions. Furthermore, we study an F(R) gravity model with a sum of exponentials form of the scale factor, where the bounce in the early universe as well as the late-time cosmic acceleration can be realized in a unified manner. As a result, we build a second order polynomial type model in terms of R and show that it could be stable. Moreover, when the scale factor is expressed by an exponential form, we derive F(R) gravity models of a polynomial type in case of the non-zero spatial curvature and that of a generic type in that of the zero spatial curvature. In addition, for an exponential form of the scale factor, an F(R) bigravity model realizing the bouncing behavior is reconstructed. It is found that in both the physical and reference metrics the bouncing phenomenon can occur, although in general the contraction and expansion rates are different each other.

79 ASTRONOMY AND ASTROPHYSICS↗

An optimal FFT-based anisotropic power spectrum estimator

Measurements of line-of-sight dependent clustering via the galaxy power spectrum's multipole moments constitute a powerful tool for testing theoretical models in large-scale structure. Recent work shows that this measurement, including a moving line-of-sight, can be accelerated using Fast Fourier Transforms (FFTs) by decomposing the Legendre polynomials into products of Cartesian vectors. Here, we present a faster, optimal means of using FFTs for this measurement. We avoid redundancy present in the Cartesian decomposition by using a spherical harmonic decomposition of the Legendre polynomials. With this method, a given multipole of order ℓ requires only 2ℓ+1 FFTs rather than the (ℓ+1)(ℓ+2)/2 FFTs of the Cartesian approach. For the hexadecapole (ℓ = 4), this translates to 40% fewer FFTs, with increased savings for higher ℓ. The reduction in wall-clock time enables the calculation of finely-binned wedges in P ( k ,μ), obtained by computing multipoles up to a large ℓ{sub max} and combining them. This transformation has a number of advantages. We demonstrate that by using non-uniform bins in μ, we can isolate plane-of-sky (angular) systematics to a narrow bin at 0μ ≅ while eliminating the contamination from all other bins. We also show that the covariance matrix of clustering wedges binned uniformly in μ becomes ill-conditioned when combining multipoles up to large values of ℓ{sub max}, but that the problem can be avoided with non-uniform binning. As an example, we present results using ℓ{sub max}=16, for which our procedure requires a factor of 3.4 fewer FFTs than the Cartesian method, while removing the first μ bin leads only to a 7% increase in statistical error on f σ{sub 8}, as compared to a 54% increase with ℓ{sub max}=4.

79 ASTRONOMY AND ASTROPHYSICS↗

Critical percolation on the kagome hypergraph

In this report we study the percolation critical surface of the kagome lattice in which each triangle is allowed an arbitrary connectivity. Using the method of critical polynomials, we find points along this critical surface to high precision. This kagome hypergraph contains many unsolved problems as special cases, including bond percolation on the kagome and (3, 12 2 ) lattices, and site percolation on the hexagonal, or honeycomb, lattice, as well as a single point for which there is an exact solution. We are able to compute enough points along the critical surface to find a very accurate fit, essentially a Taylor series about the exact point, that allows estimations of the critical point of any system that lies on the surface to precision rivaling Monte Carlo and traditional techniques of similar accuracy. We find also that this system sheds light on some of the surprising aspects of the method of critical polynomials, such as why it is so accurate for certain problems, like the kagome and (3, 12 2 ) lattices. The bond percolation critical points of these lattices can be found to 17 and 18 digits, respectively, because they are in close proximity, in a sense that can be made quantitative, to the exact point on the critical surface. We also discuss in detail a parallel implementation of the method which we use here for a few calculations.

97 MATHEMATICS AND COMPUTING↗

Time complexity and gate complexity

We formulate and investigate the simplest version of time-optimal quantum computation theory (TO-QCT), where the computation time is defined by the physical one and the Hamiltonian contains only one- and two-qubit interactions. This version of TO-QCT is also considered as optimality by sub-Riemannian geodesic length. The work has two aims: One is to develop a TO-QCT itself based on a physically natural concept of time, and the other is to pursue the possibility of using TO-QCT as a tool to estimate the complexity in conventional gate-optimal quantum computation theory (GO-QCT). In particular, we investigate to what extent is true the following statement: Time complexity is polynomial in the number of qubits if and only if gate complexity is also. In the analysis, we relate TO-QCT and optimal control theory (OCT) through fidelity-optimal computation theory (FO-QCT); FO-QCT is equivalent to TO-QCT in the limit of unit optimal fidelity, while it is formally similar to OCT. We then develop an efficient numerical scheme for FO-QCT by modifying Krotov's method in OCT, which has a monotonic convergence property. We implemented the scheme and obtained solutions of FO-QCT and of TO-QCT for the quantum Fourier transform and a unitary operator that does not have an apparent symmetry. The former has a polynomial gate complexity and the latter is expected to have an exponential one which is based on the fact that a series of generic unitary operators has an exponential gate complexity. The time complexity for the former is found to be linear in the number of qubits, which is understood naturally by the existence of an upper bound. The time complexity for the latter is exponential in the number of qubits. Thus, both the targets seem to be examples satisfyng the preceding statement. The typical characteristics of the optimal Hamiltonians are symmetry under time reversal and constancy of one-qubit operation, which are mathematically shown to hold in fairly general situations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gegenbauer-solvable quantum chain model

An N-level quantum model is proposed in which the energies are represented by an N-plet of zeros of a suitable classical orthogonal polynomial. The family of Gegenbauer polynomials G(n,a,x) is selected for illustrative purposes. The main obstacle lies in the non-Hermiticity (aka crypto-Hermiticity) of Hamiltonians H{ne}H{sup {dagger}.} We managed to (i) start from elementary secular equation G(N,a,E{sub n})=0, (ii) keep our H, in the nearest-neighbor-interaction spirit, tridiagonal, (iii) render it Hermitian in an ad hoc, nonunique Hilbert space endowed with metric {Theta}{ne}I, (iv) construct eligible metrics in closed forms ordered by increasing nondiagonality, and (v) interpret the model as a smeared N-site lattice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integro-differential equation for Bose-Einstein condensates

We use the assumption that the potential for the A-boson system can be written as a sum of pairwise acting forces to decompose the wave function into Faddeev components that fulfill a Faddeev type equation. Expanding these components in terms of potential harmonic (PH) polynomials and projecting on the potential basis for a specific pair of particles results in a two-variable integro-differential equations suitable for A-boson bound-state studies. The solution of the equation requires the evaluation of Jacobi polynomials P{sub K}{sup {alpha},{beta}}(x) and of the weight function W(z) which give severe numerical problems for very large A. However, using appropriate limits for A{yields}{infinity} we obtain a variant equation which depends only on the input two-body interaction, and the kernel in the integral part has a simple analytic form. This equation can be readily applied to a variety of bosonic systems such as microclusters of noble gasses. We employ it to obtain results for A(set-membership sign)(10-100) {sup 87}Rb atoms interacting via interatomic interactions and confined by an externally applied trapping potential V{sub trap}(r). Our results are in excellent agreement with those previously obtained using the potential harmonic expansion method (PHEM) and the diffusion Monte Carlo (DMC) method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Symmetric mixed states of n qubits: Local unitary stabilizers and entanglement classes

We classify, up to local unitary equivalence, local unitary stabilizer Lie algebras for symmetric mixed states of n qubits into six classes. These include the stabilizer types of the Werner states, the Greenberger-Horne-Zeilinger state and its generalizations, and Dicke states. For all but the zero algebra, we classify entanglement types (local unitary equivalence classes) of symmetric mixed states that have those stabilizers. We make use of the identification of symmetric density matrices with polynomials in three variables with real coefficients and apply the representation theory of SO(3) on this space of polynomials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exact dynamics of finite Glauber-Fock photonic lattices

The dynamics of Glauber-Fock lattice of size N is given through exact diagonalization of the corresponding Hamiltonian; the spectra {l_brace}{lambda}{sub k}{r_brace} is given as the roots of the Nth Hermite polynomial, H{sub N}({lambda}{sub k}/{radical}(2))=0, and the eigenstates are given in terms of Hermite polynomials evaluated at these roots. The exact dynamics is used to study coherent phenomena in discrete lattices. Due to the symmetry and spacing of the eigenvalues {l_brace}{lambda}{sub k}{r_brace}, oscillatory behavior is predicted with highly localized spectra, that is, near complete revivals of the photon number and partial recovery of the initial state at given waveguides.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kauffman knot invariant from SO(N) or Sp(N) Chern-Simons theory and the Potts model

The expectation value of Wilson loop operators in three-dimensional SO(N) Chern-Simons gauge theory gives a known knot invariant: the Kauffman polynomial. Here this result is derived, at the first order, via a simple variational method. With the same procedure the skein relation for Sp(N) are also obtained. Jones polynomial arises as special cases: Sp(2), SO(-2), and SL(2,R). These results are confirmed and extended up to the second order, by means of perturbation theory, which moreover let us establish a duality relation between SO({+-}N) and Sp({+-}N) invariants. A correspondence between the first orders in perturbation theory of SO(-2), Sp(2) or SU(2) Chern-Simons quantum holonomy's traces and the partition function of the Q=4 Potts model is built.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Generalization of the Fierz-Pauli action

We consider the Lagrangian of gravity covariantly amended by the mass and polynomial interaction terms with arbitrary coefficients and reinvestigate the consistency of such a theory in the decoupling limit, up to the fifth order in the nonlinearities. We calculate explicitly the self-interactions of the helicity-0 mode, as well as the nonlinear mixing between the helicity-0 and -2 modes. We show that ghostlike pathologies in these interactions disappear for special choices of the polynomial interactions and argue that this result remains true to all orders in the decoupling limit. Moreover, we show that the linear and some of the nonlinear mixing terms between the helicity-0 and -2 modes can be absorbed by a local change of variables, which then naturally generates the cubic, quartic, and quintic Galileon interactions, introduced in a different context. We also point out that the mixing between the helicity-0 and -2 modes can be at most quartic in the decoupling limit. Finally, we discuss the implications of our findings for the consistency of the effective field theory away from the decoupling limit, and for the Boulware-Deser problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Adaptive Bayesian Parameter Estimation of a Synchronous Generator Under Gross Errors

Polynomial-chaos-expansion-based surrogate models have recently been advocated in the literature for power system dynamic parameter estimation. Regarding the estimation of the uncertain generator parameters, a Bayesian inference framework has been proposed based on a polynomial-based reduced-order representation of the synchronous machines using assumed parameter values. Then, the non-Gaussian posterior probability distribution functions (pdfs) of these parameters are recovered through the stochastic sampling approach efficiently. However, facing very large parameter errors, the reliability of the surrogate model decreases, yielding biased estimation results. To overcome this problem, here we develop hierarchical Bayesian inference framework that processes the measurements provided by phasor measurement units, while making use of multifidelity surrogates together with the importance sampling method. The latter allows us to estimate in an efficient manner the posterior pdfs of the uncertain parameters through the normalized weights of the prior samples. To improve the accuracy of the posterior pdfs, an adaptive procedure is further adopted in the importance sampling for the gradual evolution of its proposal functions. The new proposals assist in fine-tuning the sample space and thereby help to construct surrogates with higher fidelity. Through an iterative process, this approach is able to estimate accurately and efficiently non-Gaussian posterior pdfs of the uncertain generator parameters subject to gross errors.

42 ENGINEERING↗

Conduction and rectification in NbO{sub x}- and NiO-based metal-insulator-metal diodes

Conduction and rectification in nanoantenna-coupled NbO{sub x}- and NiO-based metal-insulator-metal (MIM) diodes (“nanorectennas”) are studied by comparing new theoretical predictions with the measured response of nanorectenna arrays. A new quantum mechanical model is reported and agrees with measurements of current–voltage (I–V) curves, over 10 orders of magnitude in current density, from [NbO{sub x}(native)-Nb{sub 2}O{sub 5}]- and NiO-based samples with oxide thicknesses in the range of 5–36 nm. The model, which introduces new physics and features, including temperature, electron effective mass, and image potential effects using the pseudobarrier technique, improves upon widely used earlier models, calculates the MIM diode's I–V curve, and predicts quantitatively the rectification responsivity of high frequency voltages generated in a coupled nanoantenna array by visible/near-infrared light. The model applies both at the higher frequencies, when high-energy photons are incident, and at lower frequencies, when the formula for classical rectification, involving derivatives of the I–V curve, may be used. The rectified low-frequency direct current is well-predicted in this work's model, but not by fitting the experimentally measured I–V curve with a polynomial or by using the older Simmons model (as shown herein). By fitting the measured I–V curves with our model, the barrier heights in Nb-(NbO{sub x}(native)-Nb{sub 2}O{sub 5})-Pt and Ni-NiO-Ti/Ag diodes are found to be 0.41/0.77 and 0.38/0.39 eV, respectively, similar to literature reports, but with effective mass much lower than the free space value. The NbO{sub x} (native)-Nb{sub 2}O{sub 5} dielectric properties improve, and the effective Pt-Nb{sub 2}O{sub 5} barrier height increases as the oxide thickness increases. An observation of direct current of ∼4 nA for normally incident, focused 514 nm continuous wave laser beams are reported, similar in magnitude to recent reports. This measured direct current is compared to the prediction for rectified direct current, given by the rectification responsivity, calculated from the I–V curve times input power.

42 ENGINEERING↗

Water equivalent path length measurement in proton radiotherapy using time resolved diode dosimetry

Purpose: To verify water equivalent path length (WEPL) before treatment in proton radiotherapy using time resolved in vivo diode dosimetry. Methods: Using a passively scattered range modulated proton beam, the output of a diode driving a fast current-to-voltage amplifier is recorded at a number of depths in a water tank. At each depth, a burst of overlapping single proton pulses is observed. The rms duration of the burst is computed and the resulting data set is fitted with a cubic polynomial. Results: When the diode is subsequently set to an arbitrary depth and the polynomial is used as a calibration curve, the ''unknown'' depth is determined within 0.3 mm rms. Conclusions: A diode or a diode array, placed (for instance) in the rectum in conjunction with a rectal balloon, can potentially determine the WEPL at that point, just prior to treatment, with submillimeter accuracy, allowing the beam energy to be adjusted. The associated unwanted dose is about 0.2% of a typical single fraction treatment dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods-including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations-and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave breast imaging. Optical distortions imposed by the imaging tank and coupling bath diminished the effectiveness of the ray tracing approach; however, calibration through image registration techniques reliably produced scans of submillimeter accuracy. Tests of the system with breast-shaped phantoms demonstrated the successful implementation of the scanner for the intended application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-246: MU Model Implementation for a Passively Scattered Proton Beam: Inclusion of the Bolus Gap and Nozzle Extension Factors

Purpose: To develop and implement an MU model for a passively scattered proton beam, and eliminate the need for patient specific calibrations for field sizes from 3cm to 15cm. This would enable consistent and timely calibrations for a wide variety of patient portals, streamlining the treatment process. Methods: Measurements were initially made using a Standard Imaging A-16 ion chamber and a modified water tank to determine the bolus gap factors (BGF) for multiple combinations of aperture size, bolus thickness, and air gap. The BGF was then separated into two component factors: the bolus thickness factor (BTF) and the nozzle extension factor (NEF). Polynomial curves were generated using the measured data to produce BTF tables for air gaps from 0cm to 30cm and for bolus thicknesses from 0cm to 10cm, and NEF tables for the full range of clinically used nozzle extensions. Additionally, data tables were created for every factor that affects beam output in the MU model. The MUs were then modeled for 487 patient portals and retrospectively compared to the MUs generated from the physical calibrations previously performed. Results: Of the 487 patient portals tested, 100% of the portals used for the comparison were within 2.5% from the MUs generated using a physical calibration, and 95.9% of the MU model portals tested were within 2%. The patient portals tested had field sizes ranging from 2.1cm to 10.1cm, with air gaps from 2cm to 25cm. Output factors for field sizes below 3cm with irregularly shaped fields demonstrated inconsistent results and will be further studied. Conclusion: The most problematic output factor, the BGF, was modeled accurately and consistently using the lowest order polynomial curve fits and interpolation between measured data. The study results demonstrate the robustness of the MU model and the potential for saving valuable personnel and beam time.

07 ISOTOPE AND RADIATION SOURCES↗

TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.

60 APPLIED LIFE SCIENCES↗

A general framework of noise suppression in material decomposition for dual-energy CT

Purpose: As a general problem of dual-energy CT (DECT), noise amplification in material decomposition severely reduces the signal-to-noise ratio on the decomposed images compared to that on the original CT images. In this work, the authors propose a general framework of noise suppression in material decomposition for DECT. The method is based on an iterative algorithm recently developed in their group for image-domain decomposition of DECT, with an extension to include nonlinear decomposition models. The generalized framework of iterative DECT decomposition enables beam-hardening correction with simultaneous noise suppression, which improves the clinical benefits of DECT. Methods: The authors propose to suppress noise on the decomposed images of DECT using convex optimization, which is formulated in the form of least-squares estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, the authors include the inverse of the estimated variance–covariance matrix of the decomposed images as the penalty weight in the least-squares term. Analytical formulas are derived to compute the variance–covariance matrix for decomposed images with general-form numerical or analytical decomposition. As a demonstration, the authors implement the proposed algorithm on phantom data using an empirical polynomial function of decomposition measured on a calibration scan. The polynomial coefficients are determined from the projection data acquired on a wedge phantom, and the signal decomposition is performed in the projection domain. Results: On the Catphan{sup ®}600 phantom, the proposed noise suppression method reduces the average noise standard deviation of basis material images by one to two orders of magnitude, with a superior performance on spatial resolution as shown in comparisons of line-pair images and modulation transfer function measurements. On the synthesized monoenergetic CT images, the noise standard deviation is reduced by a factor of 2–3. By using nonlinear decomposition on projections, the authors’ method effectively suppresses the streaking artifacts of beam hardening and obtains more uniform images than their previous approach based on a linear model. Similar performance of noise suppression is observed in the results of an anthropomorphic head phantom and a pediatric chest phantom generated by the proposed method. With beam-hardening correction enabled by their approach, the image spatial nonuniformity on the head phantom is reduced from around 10% on the original CT images to 4.9% on the synthesized monoenergetic CT image. On the pediatric chest phantom, their method suppresses image noise standard deviation by a factor of around 7.5, and compared with linear decomposition, it reduces the estimation error of electron densities from 33.3% to 8.6%. Conclusions: The authors propose a general framework of noise suppression in material decomposition for DECT. Phantom studies have shown the proposed method improves the image uniformity and the accuracy of electron density measurements by effective beam-hardening correction and reduces noise level without noticeable resolution loss.

60 APPLIED LIFE SCIENCES↗

Another solution of 2D Ising model

The partition function of the Ising model on a two-dimensional regular lattice is calculated by using the matrix representation of a Clifford algebra (the Dirac algebra), with number of generators equal to the number of lattice sites. It is shown that the partition function over all loops in a 2D lattice including self-intersecting ones is the trace of a polynomial in terms of Dirac matrices. The polynomial is an element of the rotation group in the spinor representation. Thus, the partition function is a function of a character on an orthogonal group of a high degree in the spinor representation.

97 MATHEMATICS AND COMPUTING↗