Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTODETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Gas detectors for x-ray lasers

We have developed different types of photodetectors that are based on the photoionization of a gas at a low target density. The almost transparent devices were optimized and tested for online photon diagnostics at current and future x-ray free-electron laser facilities on a shot-to-shot basis with a temporal resolution of better than 100 ns. Characterization and calibration measurements were performed in the laboratory of the Physikalisch-Technische Bundesanstalt at the electron storage ring BESSY II in Berlin. As a result, measurement uncertainties of better than 10% for the photon-pulse energy and below 20 {mu}m for the photon-beam position were achieved at the Free-electron LASer in Hamburg (FLASH). An upgrade for the detection of hard x-rays was tested at the Sub-Picosecond Photon Source in Stanford.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GaN for x-ray detection

The potential of GaN based materials for x-ray detection is investigated. The absorption coefficient in GaN is measured as a function of photon energy between 6 and 40 keV. Metal-semiconductor-metal photodetectors are fabricated and characterized. The response dependence on bias, the temporal dynamics, and the response dependence on detector geometry all together point toward a mixing of photovoltaic and photoconductive effects. Thanks to a large photoconductive gain, the detector has a decent responsivity at the expense of a large response time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of a new parametric decay instability branch in TST-2 during high harmonic fast wave heating

Parametric decay instability (PDI) is often observed in the TST-2 spherical tokamak during high harmonic fast wave heating by rf pickup probes. The frequency spectrum exhibits lower and upper sideband peaks in addition to the pump wave at f{sub 0}=21 MHz. Two types of PDI are observed. One is the well-known decay into the ion-cyclotron quasimode (nf{sub ci}) and the ion Bernstein wave (f{sub 0}-nf{sub ci}). The other is a newly found decay with the sideband frequency between f{sub 0} and f{sub 0}-f{sub ci}. The frequency difference between this sideband and the pump increases in proportion to B{sub t}. Moreover, high-speed visible light measuring systems with photomultiplier tubes or hybrid photodetectors viewing the plasma core detected oscillation of light emission at around f{sub 0}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

10-fold detection range increase in quadrant-photodiode position sensing for photonic force microscope

We propose a technique that permits one to increase by one order of magnitude the detection range of position sensing for the photonic force microscope with quadrant photodetectors (QPDs). This technique takes advantage of the unavoidable cross-talk between output signals of the QPD and does not assume that the output signals are linear in the probe displacement. We demonstrate the increase in the detection range from 150 to 1400 nm for a trapped polystyrene sphere with radius of 300 nm as probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a fast position-sensitive laser beam detector

We report the development of a fast position-sensitive laser beam detector. The detector uses a fiber-optic bundle that spatially splits the incident beam, followed by a fast balanced photodetector. The detector is applied to the study of Brownian motion of particles on fast time scales with 1 A spatial resolution. Future applications include the study of molecule motors, protein folding, as well as cellular processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Plasmon Excitation via Au Nanoparticles in CdSe Semiconductor

We present experimental evidence for the large Raman and photoluminescence enhancement in CdSe semiconductor films grown on Si and glass substrates due to excitation of surface plasmon resonances in proximate gold metal nanoparticles deposited on the surface of CdSe film. Heterojunction diodes containing n-CdSe on p-Si semiconductor were fabricated and the surface of the diodes was in situ coated with Au nanoparticles using the ultra-high vacuum pulsed-laser deposition technique. A significant enhancement of the photocurrent was obtained in CdSe/p-Si containing Au nanoparticles on the surface compared to CdSe/p-Si due to the enhanced photo-absorption within the semiconductor by the phenomenon of surface plasmon resonance. These observations suggest a variety of approaches for improving the performance of devices such as photodetectors, photovoltaic, and related devices, including biosensors.

36 MATERIALS SCIENCE↗

ZnCdMgSe-Based Semiconductors for Intersubband Devices

This paper presents a review of recent results on the application of ZnCdMgSe-based wide bandgap II-VI compounds to intersubband devices such as quantum cascade lasers and quantum well infrared photodetectors operating in the mid-infrared region. The conduction band offset of ZnCdSe/ZnCdMgSe quantum well structures was determined from contactless electroreflectance measurements to be as high as 1.12 eV. FT-IR was used to measure intersubband absorption in multi-quantum well structures in the mid-IR range. Electroluminescence at 4.8 {mu}m was observed from a quantum cascade emitter structure made from these materials. Preliminary results are also presented on self assembled quantum dots of CdSe on ZnCdMgSe, and novel quantum well structures with metastable binary MgSe barriers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

AlGaN/InGaN Photocathode Development

An increase in quantum efficiency in photodetectors could result in a proportional reduction in the area of atmospheric Cherenkov telescopes and an even larger reduction in cost. We report on the development of high quantum efficiency, high gain, UV/blue photon-counting detectors based on AlGaN/InGaN photocathode heterostructures grown by molecular beam epitaxy. This research could eventually result in nearly ideal light detectors with a number of distinct advantages over existing technologies for numerous applications in high-energy physics and particle astrophysics. Potential advantages include much lower noise detection, better stability and radiation resistance than other cathode structures, high VUV sensitivity and very low radioactive background levels for deep underground experiments, and high detection efficiency for the detection of individual VUV-visible photons. We are also developing photocathodes with intrinsic gain, initially improving the detection efficiency of hybrid semiconductor-vacuum tube devices and eventually leading to a new type of all-solid-state photomultiplier device.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of near-infrared n-type {beta}-FeSi{sub 2}/p-type Si heterojunction photodiodes at room temperature

n-type {beta}-FeSi{sub 2}/p-type Si heterojunctions were fabricated from {beta}-FeSi{sub 2} films epitaxially grown on Si(111) by facing-target direct-current sputtering. Sharp film-substrate interfaces were confirmed by scanning electron microscopy. The current-voltage and photoresponse characteristics were measured at room temperature. They exhibited good rectifying properties and a change of approximately one order of magnitude in the current at a bias voltage of -1 V under illumination by a 6 mW, 1.31 {mu}m laser. The estimated detectivity was 1.5x10{sup 9} cm {radical}Hz W at 1.31 {mu}m. The results suggest that the {beta}-FeSi{sub 2}/Si heterojunctions can be used as near-infrared photodetectors that are compatible with silicon integrated circuits.

36 MATERIALS SCIENCE↗

Photoelectric effects of ultraviolet fast response and high sensitivity in LiNbO{sub 3} single crystal

The photoelectric effects in LiNbO{sub 3} (LNO) single crystal have been systematically studied with the two kinds of LNO wafers of tilt of 10 deg. and untilted at the ambient temperature. The ultrafast response photoelectric effect of 120 ps rise time was observed in 10 deg. tilted LNO single crystal with a 266 nm laser pulse of 25 ps duration. The photocurrent responsivity of untilted LNO with an interdigitated electrode of 10 mum finger width and 10 mum interspacing is 17.1 mA/W under the irradiation of 300 nm wavelength UV light at 10 V bias. The noise current under sunlight is only 73 pA at 10 V bias. The experimental results suggest that the LNO single crystal is one of the promising materials for photodetectors working in UV region.

36 MATERIALS SCIENCE↗

Radiation damage resistance of AlGaN detectors for applications in the extreme-ultraviolet spectral range

We report on the fabrication of aluminum gallium nitride (AlGaN) Schottky-photodiode-based detectors. AlGaN layers were grown using metal-organic chemical vapor deposition (MOCVD) on Si(111) wafers. The diodes were characterized at a wavelength of 13.5 nm using a table-top extreme-ultraviolet (EUV) radiation source, consisting of a laser-produced xenon plasma and a Schwarzschild objective. The responsivity of the diodes was tested between EUV energies ranging from 320 nJ down to several picojoules. For low fluences, a linear responsivity of 7.14 mAs/J could be determined. Saturation starts at approximately 1 nJ, merging into a linear response of 0.113 mAs/J, which could be attributed to the photoeffect on the Au electrodes on top of the diode. Furthermore, degradation tests were performed up to an absolute dose of 3.3x10{sup 19} photons/cm{sup 2}. AlGaN photodiodes were compared to commercially available silicon-based photodetectors. For AlGaN diodes, responsivity does not change even for the highest EUV dose, whereas the response of the Si diode decreases linearly to {approx}93% after 2x10{sup 19} photons/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Advances and Future Advances in Time-of-Flight PET

Simple theory predicts that the statistical noise variance in PET can be reduced by an order of magnitude by using time-of-flight (TOF) information. This reduction can be obtained by improving the coincidence timing resolution, and so would be achievable in clinical, whole body studies using with PET systems that differ little from existing cameras. The potential impact of this development is large, especially for oncology studies in large patients, where it is sorely needed. TOF PET was extensively studied in the 1980's but died away in the 1990's, as it was impossible to reliably achieve sufficient timing resolution without sacrificing other important PET performance aspects, such as spatial resolution and efficiency. Recent advances in technology (scintillators, photodetectors, and high speed electronics) have renewed interest in TOF PET, which is experiencing a rebirth. However, there is still much to be done, both in instrumentation development and evaluating the true benefits of TOF in modern clinical PET. This paper looks at what has been accomplished and what needs to be done before time-of-flight PET can reach its full potential.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The x-ray calibration facility of the laser integration line in the 0.9-10 keV range: The high energy x-ray source and some applications

The laser integration line (LIL) located at CEA-CESTA is equipped with x-ray plasma diagnostics using different kinds of x-ray components such as filters, mirrors, crystals, detectors, and cameras. The CEA-DAM of Arpajon is currently developing x-ray calibration methods and carrying out absolute calibration of LIL x-ray photodetectors. To guarantee LIL measurements, detectors such as x-ray cameras must be regularly calibrated close to the facility. A new x-ray facility is currently available to perform these absolute x-ray calibrations. This paper presents the x-ray tube based high energy x-ray source delivering x-ray energies ranging from 0.9 to 10 keV by means of an anode barrel. The purpose of this source is mainly to calibrate LIL x-ray cameras but it can also be used to measure x-ray filter transmission of plasma diagnostics. Different x-ray absolute calibrations such as x-ray streak and framing camera yields, x-ray charge-coupled device quantum efficiencies, and x-ray filter transmissions are presented in this paper. A x-ray flat photocathode detector sensitivity calibration recently performed for a CEA Z-pinch facility is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-chord interferometry using 3.39 {mu}m He-Ne laser on a flux-coil-generated FRC

A two-chord {lambda}{sub IR}{approx}3.39 {mu}m He-Ne laser interferometer system was developed for a flux-coil-generated field-reversed configuration to estimate the electron density and the total temperature of the field-reversed configuration (FRC) plasma. This two-chord heterodyne interferometer system consists of a single {approx}2 mW infrared He-Ne laser, a visible ({lambda}{sub vis}{approx}632.8 nm) He-Ne laser for the alignment, a 40 MHz acousto-optic modulator, photodetectors, and quadrature phase detectors. Initial measurement was performed and the measured average electron densities were 2-10x10{sup 19} m{sup -3} at two different radial positions in the midplane. A time shift in density was observed as the FRC expands radially. The time evolution of the line-averaged density agrees with the density estimated from the in situ internal magnetic probes, based on a rigid-rotor profile model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the beam emission spectroscopy diagnostic system on the National Spherical Torus Experiment

A beam emission spectroscopy (BES) system has been installed on the National Spherical Torus Experiment (NSTX) to study ion gyroscale fluctuations. The BES system measures D{sub {alpha}} emission from a deuterium neutral heating beam. The system includes two optical views centered at r/a{approx_equal}0.45 and 0.85 and aligned to magnetic field pitch angles at the neutral beam. f/1.5 collection optics produce 2-3 cm spot sizes at the neutral beam. The initial channel layout includes radial arrays, poloidal arrays, and two-dimensional grids. Radial arrays provide coverage from r/a{approx_equal}0.1 to beyond the last-closed flux surface. Photodetectors and digital filters provide high-sensitivity, low-noise measurements at frequencies of up to 1 MHz. The BES system will be a valuable tool for investigating ion gyroscale turbulence and Alfven/energetic particle modes on NSTX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Energy Laser Diagnostic Sensors

Recent advancements in high energy laser (HEL) sources have outpaced diagnostic tools capable of accurately quantifying system performance. Diagnostic tools are needed that allow system developers to measure the parameters that define HEL effectiveness. The two critical parameters for quantifying HEL effectiveness are the irradiance on target and resultant rise in target temperature. Off-board sensing has its limitations, including unpredictable changes in the reflectivity of the target, smoke and outgassing, and atmospheric distortion. On-board sensors overcome the limitations of off-board techniques but must survive high irradiance levels and extreme temperatures.We have developed sensors for on-target diagnostics of high energy laser beams and for the measurement of the thermal response of the target. The conformal sensors consist of an array of quantum dot photodetectors and resistive temperature detectors. The sensor arrays are lithographically fabricated on flexible substrates and can be attached to a variety of laser targets. We have developed a nanoparticle adhesive process that provides good thermal contact with the target and that ensures the sensor remains attached to the target for as long as the target survives. We have calibrated the temperature and irradiance sensors and demonstrated them in a HEL environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical modulation of persistent photoconductivity in ZnO nanowires

In this study, ZnO nanowires (ZNWs)-based optoelectric devices are found to exhibit strong persistent photoconductivity (PPC) effect. An optical modulation on the PPC effect of the ZNWs with 980 nm infrared (IR) laser has been investigated. It was found that the decay time for the PPC can be significantly shortened by IR irradiation. The modulation mechanism related with the oxygen vacancies and the subband gap excitation is proposed. Based on this mechanism, the modulation behavior of the IR can be well explained. The present optical modulation on the PPC is suggested to have potential applications in enhancing the performance of ZnO-based photodetectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗