Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A flexible data acquisition system architecture for the Nab experiment

Here, the Nab experiment will measure the electron–neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model physics. Using National Instrument’s PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab’s specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at a rate of at least 1 MHz, while reading out a peak signal rate of approximately 2 GB/s. During the commissioning phase of the experiment, the system ran at a sustained readout rate of 400 MB/s of detector signal data originating from roughly 6 kHz L2 triggers, well within the peak performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for new phenomena in three- or four-lepton events in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search with minimal model dependence for physics beyond the Standard Model in events featuring three or four charged leptons (3ℓ and 4ℓ, ℓ = e,μ) is presented. The analysis aims to be sensitive to a wide range of potential new-physics theories simultaneously. This analysis uses data from pp collisions delivered by the Large Hadron Collider at a centre-of-mass energy of $\sqrt{s}$ = 13 TeV and recorded with the ATLAS detector, corresponding to the full Run 2 dataset of 139 fb -1 . The 3ℓ and 4ℓ phase space is divided into 22 event categories according to the number of leptons in the event, the missing transverse momentum, the invariant mass of the leptons, and the presence of leptons originating from a Z-boson candidate. These event categories are analysed independently for the presence of deviations from the Standard Model. No statistically significant deviations from the Standard Model predictions are observed. Upper limits for all signal regions are reported in terms of the visible cross-section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MICE: The International Muon Ionization Cooling Experiment: Phase Space Cooling Measurement

MICE is an experimental demonstration of muon ionization cooling using a section of an ionization cooling channel and a muon beam. The muons are produced by the decay of pions from a target dipping into the ISIS proton beam at Rutherford Appleton Laboratory (RAL). The channel includes liquid-hydrogen absorbers providing transverse and longitudinal momentum loss and high-gradient radiofrequency (RF) cavities for longitudinal reacceleration, all packed into a solenoidal magnetic channel. MICE will reduce the beam transverse emittance by about 10% for muon momenta between 140 and 240 MeV/c. Time-of-flight (TOF) counters, threshold Cherenkov counters, and a calorimeter will identify background electrons and pions. Spectrometers before and after the cooling section will measure the beam transmission and input and output emittances with an absolute precision of 0.1%.

43 PARTICLE ACCELERATORS↗

DISCOVERY OF SMOOTHLY EVOLVING BLACKBODIES IN THE EARLY AFTERGLOW OF GRB 090618: EVIDENCE FOR A SPINE–SHEATH JET?

GRB 090618 is a bright gamma-ray burst (GRB) with multiple pulses. It shows evidence of thermal emission in the initial pulses as well as in the early afterglow phase. Because high-resolution spectral data from the Swift/X-ray Telescope (XRT) are available for the early afterglow, we investigate the shape and evolution of the thermal component in this phase using data from the Swift/Burst Alert Telescope (BAT), the Swift/XRT, and the Fermi/Gamma-ray Burst Monitor detectors. An independent fit to the BAT and XRT data reveals two correlated blackbodies with monotonically decreasing temperatures. Hence, we investigated the combined data with a model consisting of two blackbodies and a power law (2BBPL), a model suggested for several bright GRBs. We elicit the following interesting features of the 2BBPL model: (1) the same model is applicable from the peak of the last pulse in the prompt emission to the afterglow emission, (2) the ratio of temperatures and the fluxes of the two blackbodies remains constant throughout the observations, (3) the blackbody temperatures and fluxes show a monotonic decrease with time, with the BB fluxes dropping about a factor of two faster than that of the power-law (PL) emission, and (4) attributing the blackbody emission to photospheric emissions, we find that the photospheric radii increase very slowly with time, and the lower-temperature blackbody shows a larger emitting radius than that of the higher-temperature blackbody. We find some evidence that the underlying shape of the nonthermal emission is a cutoff power law rather than a PL. We sketch a spine–sheath jet model to explain our observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a tagged source of Pb-206 nuclei

There is a particular class of unavoidable backgrounds that plague low-background experiments and rare event searches, particularly those searching for nuclear recoil event signatures: decaying daughters of the 238 U nuclear decay chain, which result from radon plate-out on detector materials. One such daughter isotope, 210 Po, undergoes α-decay and produces a recoiling 103 keV 206 Pb nucleus. In this study, to characterize this important background in the context of noble element detectors, we have implemented a triggered source for these 206 Pb recoils in a dual-phase xenon time projection chamber (Xe TPC) within the Davis Xenon R&D testbed system (DAX). By adhering 210 Po to the surface of a PIN diode and electrically floating the diode on the cathode of the TPC, we tag the α signals produced in the PIN diode and trigger on the correlated nuclear recoils in the liquid xenon (LXe). Lastly, we discuss our methods for 210 Po deposition, electronic readout of the PIN diode signals at high voltage, and analysis methods for event selection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulations of trapped ultracold neutrons in the UCN τ experiment

We report that in the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trapping mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN—whose dynamics can be described by Hamiltonian mechanics—do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trapping in the UCNτ magnetogravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase-space evolution of neutrons observed in the UCNτ experiment. Lastly, we will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of C P Violation Observables in D + → K − K + π + Decays

A search for violation of the charge-parity ( C P ) symmetry in the D + → K − K + π + decay is presented, with proton-proton collision data corresponding to an integrated luminosity of 5.4 fb − 1 , collected at a center-of-mass energy of 13 TeV with the LHCb detector. A novel model-independent technique is used to compare the D + and D − phase-space distributions, with instrumental asymmetries subtracted using the D s + → K − K + π + decay as a control channel. The p value for the hypothesis of C P conservation is 8.1%. The C P asymmetry observables A C P | S ϕ π + = ( 0.95 ± 0.4 3 stat ± 0.2 6 syst ) × 10 − 3 and A C P | S K ¯ * 0 K + = ( − 0.26 ± 0.5 6 stat ± 0.1 8 syst ) × 10 − 3 are also measured. These results show no evidence of C P violation and represent the most sensitive search performed through the phase space of a multibody decay. © 2024 CERN, for the LHCb Collaboration 2024 CERN

Aaij, R. (ORCID:0000000305331952)↗

Report of improved performance in Talbot–Lau phase-contrast computed tomography

Purpose: Many expectations have been raised since the use of conventional x-ray tubes on grating-based x-ray phase-contrast imaging. Despite a reported increase in contrast-to-noise ratio (CNR) in many publications, there is doubt on whether phase-contrast computed tomography (CT) is advantageous in clinical CT scanners in vivo. The aim of this paper is to contribute to this discussion by analyzing the performance of a phase-contrast CT laboratory setup. Methods: A phase-contrast CT performance analysis was done. Projection images of a phantom were recorded, and image slices were reconstructed using standard filtered back projection methods. The resulting image slices were analyzed by determining the CNRs in the attenuation and phase image. These results were compared to analytically calculated expectations according to the already published phase-contrast CT performance analysis by Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)]. There, a severe mistake was found leading to wrong predictions of the performance of phase-contrast CT. The error was corrected and with the new formulae, the experimentally obtained results matched the analytical calculations. Results: The squared ratios of the phase-contrast CNR and the attenuation CNR obtained in the authors’ experiment are five- to ten-fold higher than predicted by Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)]. The effective lateral spatial coherence length deduced outnumbers the already optimistic assumption of Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)] by a factor of 3. Conclusions: The authors’ results indicate that the assumptions made in former performance analyses are pessimistic. The break-even point, when phase-contrast CT outperforms attenuation CT, is within reach even with realistic, nonperfect gratings. Further improvements to state-of-the-art clinical CT scanners, like increasing the spatial resolution, could change the balance in favor of phase-contrast computed tomography even more. This could be done by, e.g., quantum-counting pixel detectors with four-fold smaller pixel pitches.

60 APPLIED LIFE SCIENCES↗

Holotomography Phase-Retrieval

Holotomography is a non-destructive x-ray imaging technique which allows to visualize the interior morphology of object without damaging them. It is similar to x-ray computed tomography (CT), but unlike conventional CT, which is based on the attenuation of x-rays passing through the object, holotomography exploits the phase shift caused by the sample. This phase-contrast imaging allows to increase image contrast by recovering refractive index of materials and is proven to be more sensitive to density variations than conventional absorption-based X-ray imaging when applied to low-Z materials. In holotomography, the phase is retrieved by measuring the variations in intensity of the object at different sample to detector distances. Several algorithms exist to perform this task such as, contrast transfer function (CTF), transport of intensity equation (TIE), and a mixed approach which combine both TIE and CTF.

Forien, Jean-Baptiste↗

Phase and amplitude retrieval of objects embedded in a sinusoidal background from its diffraction pattern

Efforts of phase and amplitude retrieval from diffraction patterns have almost exclusively been applied for nonperiodic objects. We investigated the quality of retrieval of nonperiodic objects embedded in a sinusoidal background, using the approach of iterative hybrid input-output with oversampling. Two strategies were employed; one by filtering in the frequency domain prior to phase retrieval, and the other by filtering the phase or amplitude image after retrieval. Results obtained indicate better outcomes with the latter approach provided detector noise is not excessive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Muon Beam Dynamics and Spin Dynamics in the g-2 Storage Ring

The goal of the new g-2 experiment at fermilab is a measurement of the anomalous magnetic moment of the muon, with uncertainty of less than 140 ppb. The experimental method is to store a beam of polarized muons in a storage ring with pure vertical dipole field and electrostatic focusing, and to measure the precession frequency. Control of the systematics depends on unprecedented knowledge of the details of the phase space of the muon distribution. That knowledge is derived from direct measurements with scintillating fiber detectors that are inserted into the muon beam for diagnostic measurements, traceback straw tube tracking chambers, as well as the calorimeters that measure energy, time and position of the decay positrons. The interpretation of the measurements depends on a detailed model of the storage ring guide field. This invited talk presents results of studies of the distribution from the commissioning run of the experiment.

43 PARTICLE ACCELERATORS↗

Design and Test of the Mu2e Undoped CsI + SiPM Crystal Calorimete

The talk focused on the Charged Lepton Flavor Violation (CLFV) part of the Mu2e project, including an introduction of the concept and the experimental layout and detectors. Calorimeter requirements were also discussed, including components, single channel tests, prototypes' performance, and the production phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Introduction to Radiation Damage in Minerals and Ceramics [Slides]

Radiation effects in minerals and ceramics are quite distinct from effects observed in metals. This is largely due to interactions between radiation and the electronic structure of insulating materials that are unique compared to metallic conductors. Most notably, insulators exhibit property changes when energetic particles lose energy to electrons in the solid, whereas metals are unaffected by electronic energy losses. In addition, displacive radiation damage effects (atoms being knocked off their lattice sites by energetic particles) are much more complex in insulators, due to the complexities of their crystal structures (multiple cation and anion sublattices). In this presentation, we will focus on the atomistic mechanisms responsible for radiation damage in minerals and ceramics, when energetic particles lose energy while penetrating a solid. We will consider several examples, including (i) irradiation induced color center formation in gemstones; (ii) latent defects in alkali halides (relevance to thermoluminescent detectors); (iii) radioactive decay-induced amorphization of natural minerals; and (iv) extended defect formation and phase stability in complex oxides.

36 MATERIALS SCIENCE↗

Methodology of the Extraction of Multi-Differential Cross Sections of Charged-Current $\nu_\mu$-Argon Interactions in MicroBooNE Using Wire-Cell $\nu_\mu$CC Selection

Neutrino physics experiments rely on accurate nuclear-interaction models that are in part guided by experimental observations. Multi-differential cross section measurements are particularly valuable for exploring the underlying physics described in these models, making them a significant step forward in the field. This note presents methodology in preparation to unfold neutrino flux-averaged double and triple-differential cross sections of the inclusive muon neutrino charged-current interaction on Argon. This work builds upon the existing framework and methodology presented in recent energy dependent cross section measurements at MicroBooNE using the Wire-Cell tomographic event reconstruction. The signal definition, choice of binning, and handling of estimated detector uncertainties are discussed, and the MicroBooNE simulation model is validated over the multi-dimensional phase space of muon momentum, muon polar angle, and visible hadronic energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polarimeters and Energy Spectrometers for the ILC Beam Delivery System

This article gives an overview of current plans and issues for polarimeters and energy spectrometers in the Beam Delivery System of the ILC. It is meant to serve as a useful reference for the Detector Letter of Intent documents currently being prepared. Concepts for high precision polarization and energy measurements exist. These concepts have resulted in detailed system layouts that are included in the RDR description for the Beam Delivery System. The RDR includes both upstream and downstream polarimeters and energy spectrometers for both beams. This provides needed complementarity and redundancy for achieving the precision required, with adequate control and demonstration of systematic errors. The BDS polarimeters and energy spectrometers need to be a joint effort of the ILC BDS team and the Detector collaborations, with collaboration members responsible for the performance and accuracy of the measurements. Details for this collaboration and assigning of responsibilities remain to be worked out. There is also a demonstrated need for Detector physicists to play an active role in the design and evaluation of accelerator components that impact beam polarization and beam energy capabilities, including the polarized source and spin rotator systems. A workshop was held in 2008 on ILC Polarization and Energy measurements, which resulted in a set of recommendations for the ILC design and operation. Additional input and action is needed on these from the Detector collaborations, the Research Director and the GDE. Work is continuing during the ILC engineering design phase to further optimize the polarimeter and energy spectrometer concepts and fully implement them in the ILC. This includes consideration for alternative methods, detailed design and cost estimates, and prototype and test beam activities.

43 PARTICLE ACCELERATORS↗

Light Dark Matter eXperiment (LDMX)

We present an initial design study for LDMX, the Light Dark Matter Experiment, a small-scale accelerator experiment having broad sensitivity to both direct dark matter and mediator particle production in the sub-GeV mass region. LDMX employs missing momentum and energy techniques in multi-GeV electro-nuclear fixed-target collisions to explore couplings to electrons in uncharted regions that extend down to and below levels that are motivated by direct thermal freeze-out mechanisms. LDMX would also be sensitive to a wide range of visibly and invisibly decaying dark sector particles, thereby addressing many of the science drivers highlighted in the 2017 US Cosmic Visions New Ideas in Dark Matter Community Report. LDMX would achieve the required sensitivity by leveraging existing and developing detector technologies from the CMS, HPS and Mu2e experiments. In this paper, we present our initial design concept, detailed GEANT-based studies of detector performance, signal and background processes, and a preliminary analysis approach. We demonstrate how a first phase of LDMX could expand sensitivity to a variety of light dark matter, mediator, and millicharge particles by several orders of magnitude in coupling over the broad sub-GeV mass range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning Trigger for the SpinQuest/E1039 Experiment

The SpinQuest experiment at Fermilab aims to measure the Sivers asymmetry for the light antiquarks in the nucleon using the Drell-Yan process. If the Sivers asymmetry is not zero, we will have found evidence for non-zero orbital angular momentum of light antiquarks. The commissioning of the SpinQuest experiment has two phases. First, we will trigger on cosmic ray muons to understand the performance of the SpinQuest detector which comprises hodoscopes, wire chambers, and proportional tubes. Second, we will use the 120 GeV Main Injector proton beam to test all the detectors more thoroughly and analyze the data to get prepared for physics running. This poster will present the structure of the commissioning trigger, the timing calibration, and the measured performance of the hodoscopes using cosmic rays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗