Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Synergism requirements and concepts for SAR and HIRIS on EOS

A study is conducted to ascertain the synergistic advantages obtainable by combining, in the EOS orbital instrument platform, instruments for the optical and microwave measurements of biophysical properties important in ecosystem modeling. Attention is given to the comparative coverages of the SAR, HIRIS, TIMS and MODIS instruments that will be carried by the platform, and to the ongoing development of joint inversion algorithms for the modeling of the ecosystems-related data thus obtained. A three-dimensional characterization of the physical attributes of the vegetation canopy and its background surface will be attempted.

Cimino, J. B.↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗

Report of the facility definition team spacelab UV-Optical Telescope Facility

Scientific requirements for the Spacelab Ultraviolet-Optical Telescope (SUOT) facility are presented. Specific programs involving high angular resolution imagery over wide fields, far ultraviolet spectroscopy, precisely calibrated spectrophotometry and spectropolarimetry over a wide wavelength range, and planetary studies, including high resolution synoptic imagery, are recommended. Specifications for the mounting configuration, instruments for the mounting configuration, instrument mounting system, optical parameters, and the pointing and stabilization system are presented. Concepts for the focal plane instruments are defined. The functional requirements of the direct imaging camera, far ultraviolet spectrograph, and the precisely calibrated spectrophotometer are detailed, and the planetary camera concept is outlined. Operational concepts described in detail are: the makeup and functions of shuttle payload crew, extravehicular activity requirements, telescope control and data management, payload operations control room, orbital constraints, and orbital interfaces (stabilization, maneuvering requirements and attitude control, contamination, utilities, and payload weight considerations).

Source record↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Variation of the urban NO2 concentration during a ground inversion situation

In February 1985 the NO2 concentration over Goeteborg, a major Swedish city, was monitored during two inversion situations. The differential absorption technique was employed and the results show the build-up of the concentration. In this experiment the laser beam was scanned horizontally over Goeteborg. The results were presented as maps over the NO2 concentration distribution. For security reasons the beam was not parallel to the ground, which gives a height gradient in some measurements. During the measurement period the NO2 concentration variation build-up from the morning to the afternoon was monitored. Great concentration variations were seen. Later the mixing below the inversion layer, resulting in a more uniform, high concentration was seen. The breakdown of the inversion when stronger winds start was also seen. Comparisons with a traditional point-measuring chemiluminiscence instrument and an optical method DOAS (Differential Optical Absorption Spectroscopy), were made. The results are discussed. Strong spatial concentration variations are shown by the lidar measurements. For a point-measuring system, the instrument must be very carefully placed since its location will strongly influence the values it gives.

Sunesson, A.↗

NASA’s PACE Ocean Color Instrument Thermal Design Evolution: from Goddard’s Instrument Design Lab through Flight Development

NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, set to launch in 2024, seeks to provide data continuity for the ocean color, aerosol and cloud measurements acquired by NASA’s on-orbit Earth Science observatories since the 1990s. It will accomplish this through its Ocean Color Instrument (OCI), an optical spectrometer being developed for hyper-spectral measurements in the ultraviolet-to-near-infrared band between 340 nm and 2260 nm. Although OCI’s instrument architecture will provide greater insight and resolution than its predecessors in this wavelength range, the engineering required to achieve this also poses a greater challenge. In thermal engineering, this translates to a more complex thermal control approach to address high heat dissipations, stringent stabilities, the volume of heat that requires transport, and changing thermal environments due to tilting of the entire instrument ±20° twice per orbit. This current work explores how the PACE OCI instrument design has evolved from its initial conception in NASA Goddard’s Instrument Design Laboratory (IDL) to the current iteration of its flight design. The IDL studies explored three separate instrument configurations and two spatial resolutions per configuration, which were then down selected to a single instrument type and spatial resolution for flight instrument development. OCI subsequently went through major project milestones, including Preliminary Design Review (PDR), Critical Design Review (CDR), Pre-Environmental Review (PER) and Pre-Ship Review (PSR), with significant design updates along the way. This paper aims to provide a comprehensive account of OCI’s thermal control architecture evolution and the engineering drivers that have shaped it, with the goal of identifying trends spanning the full instrument development timeline to inform and advance future instrument thermal designs.

PACE↗

NASA’s PACE Ocean Color Instrument Thermal Design Evolution: from Goddard’s Instrument Design Lab through Flight Development

NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, set to launch in 2024, seeks to provide data continuity for the ocean color, aerosol and cloud measurements acquired by NASA’s on-orbit Earth Science observatories since the 1990s. It will accomplish this through its Ocean Color Instrument (OCI), an optical spectrometer being developed for hyper-spectral measurements in the ultraviolet-to-near-infrared band between 340 nm and 2260 nm. Although OCI’s instrument architecture will provide greater insight and resolution than its predecessors in this wavelength range, the engineering required to achieve this also poses a greater challenge. In thermal engineering, this translates to a more complex thermal control approach to address high heat dissipations, stringent stabilities, the volume of heat that requires transport, and changing thermal environments due to tilting of the entire instrument ±20° twice per orbit. This current work explores how the PACE OCI instrument design has evolved from its initial conception in NASA Goddard’s Instrument Design Laboratory (IDL) to the current iteration of its flight design. The IDL studies explored three separate instrument configurations and two spatial resolutions per configuration, which were then down selected to a single instrument type and spatial resolution for flight instrument development. OCI subsequently went through major project milestones, including Preliminary Design Review (PDR), Critical Design Review (CDR), Pre-Environmental Review (PER) and Pre-Ship Review (PSR), with significant design updates along the way. This paper aims to provide a comprehensive account of OCI’s thermal control architecture evolution and the engineering drivers that have shaped it, with the goal of identifying trends spanning the full instrument development timeline to inform and advance future instrument thermal designs.

PACE↗

Shuttle PRCS plume contamination analysis for Astro-2 mission

The Astro-2 mission scheduled for Jan. 1995 flight is co-manifested with the Spartan experiment. The Astro instrument array consists of several telescopes operating in the UV spectrum. To obtain the desired 300 observations with the telescope array in a shorter time than the Astro-1 mission, it will be necessary to use the primary reaction control system (PRCS) rather than just the Vernier reaction control system. The high mass flow rate of the PRCS engines cause considerable concern about contamination due to PRCS plume return flux. Performance of these instruments depends heavily on the environment they encounter. The ability of the optical system to detect a remote signal depends not only on the intensity of the incoming signal, but also on the ensuing transmission loss through the optical train of the instrument. Performance of these instruments is thus dependent on the properties of the optical surface and the medium through which it propagates. The on-orbit contamination environment will have a strong influence on the performance of these instruments. The finding of a two-month study of the molecular contamination environment of the Astro-2 instruments due to PRCS thruster plumes during the planned Astro-2 mission are summarized.

Wang, Francis C.↗

Instrument Measures Shift In Focus

Optical components tested at wavelengths from ultraviolet to infrared. Focus-shift-measuring instrument easy to use. Operated in lighted room, without having to make delicate adjustments while peering through microscope. Measures distance along which focal point of converging beam of light shifted by introduction of nominally plane parallel optical component into beam. Intended primarily for measuring focus shifts produced by windows and filters at wavelengths from 120 to 1,100 nanometers. Portable, compact, and relatively inexpensive for degree of precision.

Steimle, Lawrence J.↗

Preliminary Design of a Lightning Optical Camera and ThundEr (LOCATE) Sensor

The preliminary design of an optical/acoustical instrument is described for making highly accurate real-time determinations of the location of cloud-to-ground (CG) lightning. The instrument, named the Lightning Optical Camera And ThundEr (LOCATE) sensor, will also image the clear and cloud-obscured lightning channel produced from CGs and cloud flashes, and will record the transient optical waveforms produced from these discharges. The LOCATE sensor will consist of a full (360 degrees) field-of-view optical camera for obtaining CG channel image and azimuth, a sensitive thunder microphone for obtaining CG range, and a fast photodiode system for time-resolving the lightning optical waveform. The optical waveform data will be used to discriminate CGs from cloud flashes. Together, the optical azimuth and thunder range is used to locate CGs and it is anticipated that a network of LOCATE sensors would determine CG source location to well within 100 meters. All of this would be accomplished for a relatively inexpensive cost compared to present RF lightning location technologies, but of course the range detection is limited and will be quantified in the future. The LOCATE sensor technology would have practical applications for electric power utility companies, government (e.g. NASA Kennedy Space Center lightning safety and warning), golf resort lightning safety, telecommunications, and other industries.

Phanord, Dieudonne D.↗

Thermal Considerations for Reducing the Cooldown and Warmup Duration of the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in 2018, is NASAs next-generation flagship telescope. The Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) contain all of the optical surfaces and instruments to capture and analyze the telescopes infrared targets. The integrated OTE and ISIM are denoted as OTIS, and will be tested as a single unit in a critical thermal-vacuum test in mid-2017 at NASA Johnson Space Centers Chamber A facility. The payload will be evaluated for workmanship and functionality in a 20K simulated flight environment during this thermal-vacuum test. However, the sheer thermal mass of the OTIS payload as well as the restrictive gradient, rate, and contamination-related constraints placed on test components precludes rapid cooldown or warmup to its steady-state cryo-balance condition. Hardware safety considerations precludes injection of helium gas for free molecular heat transfer. Initial thermal analysis predicted that transient radiative cooldown from ambient temperatures, while meeting all limits and constraints, would take 33.3 days; warmup similarly would take 28.4 days. This paper discusses methods used to reduce transition times from the original predictions through modulation of boundary temperatures and environmental conditions. By optimizing helium shroud transition rates and heater usage, as well as rigorously re-examining previously imposed constraints, savings of up to three days on cooldown and up to a week on warmup can be achieved. The efficiencies gained through these methods allow the JWST thermal test team to create faster cooldown and warmup profiles, thus reducing the overall test duration and cost, while keeping all of the required test operations.

Thermal↗

Thermal Considerations for Reducing the Cooldown and Warmup Duration of the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in 2018, is NASAs next-generation flagship telescope. The Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) contain all of the optical surfaces and instruments to capture and analyze the telescopes infrared targets. The integrated OTE and ISIM are denoted as OTIS, and will be tested as a single unit in a critical thermal-vacuum test in mid-2017 at NASA Johnson Space Centers Chamber A facility. The payload will be evaluated for workmanship and functionality in a 20K simulated flight environment during this thermal-vacuum test. However, the sheer thermal mass of the OTIS payload as well as the restrictive gradient, rate, and contamination-related constraints placed on test components precludes rapid cooldown or warmup to its steady-state cryo-balance condition. Hardware safety considerations precludes injection of helium gas for free molecular heat transfer. Initial thermal analysis predicted that transient radiative cooldown from ambient temperatures, while meeting all limits and constraints, would take 33.3 days; warmup similarly would take 28.4 days. This paper discusses methods used to reduce transition times from the original predictions through modulation of boundary temperatures and environmental conditions. By optimizing helium shroud transition rates and heater usage, as well as rigorously re-examining previously imposed constraints, savings of up to three days on cooldown and up to a week on warmup can be achieved. The efficiencies gained through these methods allow the JWST thermal test team to create faster cooldown and warmup profiles, thus reducing the overall test duration and cost, while keeping all of the required test operations.

JWST↗

The solar ultraviolet spectral irradiance monitor (SUSIM) experiment on board the Upper Atmosphere Research Satellite (UARS)

The state of solar ultraviolet irradiance measurements in 1978, when NASA requested proposals for a new generation of solar ultraviolet monitors to be flown on the Upper Atmosphere Research Satellite (UARS), is described. To overcome the radiometric uncertainties that plagued the measurements at this time, the solar ultraviolet spectral irradiance monitor (SUSIM) instrument design included in-flight calibration light sources and multichannel photometers. Both are aimed at achieving a maximum precision of the SUSIM measurements over a long period of time, e.g., one solar cycle. The design of the SUSIM-UARS instrument is compared with the original design specifications for the UARS instruments. Details including optical train, filters, detectors, and contamination precautions are described. Also discussed are the SUSIM-UARS preflight calibration and characterization, as well as the results of the inflight performance of the instrument during the first 3 months of operation. Finally, flight operations, observation strategy, and data reduction schemes are outlined.

Brueckner, G. E.↗

Nanoscale Deformable Optics

Several missions and instruments in the conceptual design phase rely on the technique of interferometry to create detectable fringe patterns. The intimate emplacement of reflective material upon electron device cells based upon chalcogenide material technology permits high-speed, predictable deformation of the reflective surface to a subnanometer or finer resolution with a very high degree of accuracy. In this innovation, a layer of reflective material is deposited upon a wafer containing (perhaps in the millions) chalcogenic memory cells with the reflective material becoming the front surface of a mirror and the chalcogenic material becoming a means of selectively deforming the mirror by the application of heat to the chalcogenic material. By doing so, the mirror surface can deform anywhere from nil to nanometers in spots the size of a modern day memory cell, thereby permitting realtime tuning of mirror focus and reflectivity to mitigate aberrations caused elsewhere in the optical system. Modern foundry methods permit the design and manufacture of individual memory cells having an area of or equal to the Feature (F) size of the design (assume 65 nm). Fabrication rules and restraints generally require the instantiation of one memory cell to another no closer than 1.5 F, or, for this innovation, 90 nm from its neighbor in any direction. Chalcogenide is a semiconducting glass compound consisting of a combination of chalcogen ions, the ratios of which vary according to properties desired. It has been shown that the application of heat to cells of chalcogenic material cause a large alteration in resistance to the range of 4 orders of magnitude. It is this effect upon which chalcogenidebased commercial memories rely. Upon removal of the heat source, the chalcogenide rapidly cools and remains frozen in the excited state. It has also been shown that the chalcogenide expands in volume because of the applied heat, meaning that the coefficient of expansion of chalcogenic materials is larger than 1. In this innovation, chalcogenidebased cells are addressed (as though they are a memory), and heated and cooled according to well-established criteria. In doing so, the exact size of chalcogenide cell deformation is known and predictable; therefore, the deformation of the reflective surface is, likewise, known and predictable. Control electronics can also be implemented so that a closed-loop feedback can be maintained. Changing the contents of the chalcogenide memory cells can compensate for any change in environmental effects that might cause a change in optical path. This real-time control provides significant control and stability in use conditions.

Strauss, Karl F.↗

Overview of Terra and Aqua MODIS Status

This presentation will consist of two one-hour lectures. The first lecture will review the characteristics of the MODIS instrument and how it responds to the performance specifications. The pre-launch and on-orbit procedures and results to characterize and maintain instrument output so as to allow the prescribed science to be done will also be outlined. This will include defining the equations used to account for gain changes and any degradation in the optics of the instrument or the on-board calibration devices themselves. The changes in the solar diffuser and the radiance versus scan angle performance of the scan mirror will also be reviewed. Overall it will be shown that the instrument has and is meeting specifications of 2% reflectance relative to the sun, 5% in the radiance observed in the reflected solar radiation bands, and 0.5-1% in the thermal bands. The second lecture will review and describe highlights in the geophysical products and related science results. There are approximately 40 geophysical products related to observations of land, ocean and atmosphere features. Many of the results are unprecedented and offer considerable advances over those achievable with heritage instruments such as the NOAA Advanced Very High Resolution Radiometer (AVHRR). The literature is showing a steady growth of publications in scientific journals using MODIS data or products. The future is also bright in that a follow-on instrument based on the MODIS will be flown on the National Polar-Orbiting Environmental Satellite Series (NPOESS) starting around 2010.

Salomonson, Vincent V.↗

Imaging Technique for High Precision Measurement of Detector Stability for the Ocean Color Instrument

One of the new projects by NASA to explore environmental change is the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft. The primary instrument aboard the PACE spacecraft is the Ocean Color Instrument (OCI), an advanced optical spectrometer that will measure the color of the ocean from the ultraviolet to shortwave infrared range for the purpose of observing and monitoring ocean and coastal biology. As part of the optical alignment testing that must be completed before the instrument is built, the measurement stability of the detectors at space flight operating temperatures must be determined to ensure alignment is maintained. Therefore, this project focuses on the development of an imaging technique that adheres to testing requirements and can be used to determine the stability of the OCI detector. The movements of targets affixed to a high-precision stage were analyzed through an image processing program to test the ability of the imaging technique to detect very small (under 10 micrometers) movements. It was found that movements as small as half a pixel (~6 microns) and 1 pixel (~12 microns) were able to be accurately and consistently detected with this imaging technique. This project found that the designed image analysis technique fulfills testing and measurement requirements and will be an effective metrology technique for the OCI detector stability test.

Optics↗

Predictions of the On-Orbit Performance of AXAF's Optics

The AXAF optics and science instruments have recently undergone a battery of tests at the Marshall Space Flight Center X-Ray Calibration Facility to determine their spatial and spectral performance. We have combined these data, detailed maps of the optics, surfaces, precise measurements of surface roughness and reflectivity, and detailed mechanical models of the optics and their support structures to arrive at predictions of the optics' on-orbit performance. We present on- and off-axis effective areas, encircled energies, and PSFS.

Jerius, D.↗