Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking

Purpose: To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory monitoring, and to investigate the performance of a dynamic multileaf collimator tracking system using this method. Methods and Materials: The real-time three-dimensional internal target position estimation was established by creating a time-varying correlation model that connected the external respiratory signals with the internal target motion measured intermittently using kV/MV imaging. The method was integrated into a dynamic multileaf collimator tracking system. Tracking experiments were performed for 10 thoracic/abdominal traces. A three-dimensional motion platform carrying a gold marker and a separate one-dimensional motion platform were used to reproduce the target and external respiratory motion, respectively. The target positions were detected by kV (1 Hz) and MV (5.2 Hz) imaging, and external respiratory motion was captured by an optical system (30 Hz). The beam-target alignment error was quantified as the positional difference between the target and circular beam center on the MV images acquired during tracking. The correlation model error was quantified by comparing a model estimate and measured target positions. Results: The root-mean-square errors in the beam-target alignment that had ranged from 3.1 to 7.6 mm without tracking were reduced to <1.5 mm with tracking, except during the model building period (6 s). The root-mean-square error in the correlation model was submillimeters in all directions. Conclusion: A novel real-time target position estimation method was developed and integrated into a dynamic multileaf collimator tracking system and demonstrated an average submillimeter geometric accuracy after initializing the internal/external correlation model. The method used hardware tools available on linear accelerators and therefore shows promise for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A low cost high temperature sun tracking solar energy collector

The design and economic evaluation of a low cost high temperature two axis sun tracking solar energy collector are described. The collector design is specifically intended for solar energy use with the freedom of motion about its two control axes being limited only to the amplitude required to track the sun. An examination of the performance criteria required in order to track the sun and perform the desired solar energy conversion is used as the starting point and guide to the design. This factor, along with its general configuration and structural aspect ratios, is the significant contributor to achieving low cost. The unique mechanical design allows the control system to counter wide tolerances that will be specified for the fabrication of the azimuth frame and perform within a small tracking error.

Perkins, G. S.↗

Beaufort-Chukchi ice margin data from Seasat - Ice motion

The motion of sea ice in the summer and fall marginal zone of the Beaufort and Chukchi seas is observed by tracking ice features in sequential Seasat synthetic aperture radar images. Four examples of ice motion fields are shown and discussed with translation observation density finer than one observation per 5 km for the most part. In this region the components of proportional relative motion are shown to commonly have values in the range 0.1 to 0.25/day throughout the marginal zone, which itself has a scale of the order of 100 km.

Carsey, Frank↗

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

Wind estimates from cloud motions - Results from Phases I, II and III of an in situ aircraft verification experiment

An experiment is in progress to verify geostationary-satellite-derived cloud-motion wind estimates by in-situ aircraft wind-velocity measurements. One or more low-level aircraft equipped with Inertial Navigation Systems (INS) were used to define the vertical extent and horizontal motion of a cloud and to measure the ambient wind field. A high-level aircraft, also equipped with an INS, took photographs to describe the horizontal extent of the cloud field and to measure cloud motion. To date the experiment has been conducted over tropical oceans and in the western Gulf of Mexico. A total of 60 h have been spent tracking some 40 tropical cumulus and five cirrus clouds. Results for tropical cumulus clouds indicate excellent agreement between the cloud motion and the wind at cloud base. The magnitude of the vector difference between the cloud motion and the cloud-base wind is less than 1.3 m/s for 67% of the cases with track lengths of 1 h or longer. Similarly, the vector differences between the cloud motion and the wind at sub-cloud (150 m), mid-cloud, and cloud-top levels are 1.5, 3.6 and 7.0 m/s, respectively. The cirrus cloud motions agreed best with the mean wind in the cloud layer with a vector difference of about 1.6 m/s.

Hasler, A. F.↗

Three dimensional time-gated tracking of non-blinking quantum dots in live cells

Single particle tracking has provided a wealth of information about biophysical processes such as motor protein transport and diffusion in cell membranes. However, motion out of the plane of the microscope or blinking of the fluorescent probe used as a label generally limits observation times to several seconds. Here, we overcome these limitations by using novel non-blinking quantum dots as probes and employing a custom 3D tracking microscope to actively follow motion in three dimensions (3D) in live cells. As a result, signal-to-noise is improved in the cellular milieu through the use of pulsed excitation and time-gated detection.

59 BASIC BIOLOGICAL SCIENCES↗

Polar motion and earth tides from Beacon Explorer C

Seventeen months of laser tracking of the Beacon Explorer C spacecraft by a Goddard Space Flight Center laser system were analyzed. The amplitude and phase of the solid-earth and ocean-tide perturbations of the orbit and the variation in latitude of the tracking station were determined. From an analysis of the orbital inclination obtained from 6 hour data spans the tidal perturbations of the orbit were found to have a magnitude equivalent to a second degree Love number, k sub 2, of 0.245 with a phase lag of about 3.2 degrees. These numbers are in complete agreement with values obtained previously from a much shorter data span, although k sub 2, is lower than the value derived from seismic data. This discrepancy is probably due to the influence of the oceans on the satellite result. After removing the tidal perturbations the residuals in inclination were of order 0.04 arcseconds. This implies that the variation in latitude of the station was being determined during the 17 months period with an rms deviation of about 1.4 meters with respect to the smoothed Bureau International de l'Heure values.

Kolenkiewicz, D. E.↗

Velocity and Turbulence Measurements at Three Locations in the Salish Sea, WA, 2017

This submission contains raw and processed datasets of water velocity and turbulence measurements from 3-day deployments of Deepwater Buoyancy StableMoor buoys carrying acoustic Doppler instrumentation at locations in Rosario Strait, Bellingham Channel, and Tacoma Narrows, WA in 2017. Two StableMoor buoy configurations were used at these sites. The StableMoor500 carried a nose-mounted acoustic doppler velocimeter (ADV) and a down-looking acoustic doppler current profiler (ADCP), and the StableMoor400 carried dual wing-mounted ADVs located on either side of the nose and a down-looking ADCP. Each StableMoor was designed to fly at an altitude of 10 m above the seafloor. The StableMoor500 was deployed in Bellingham Channel at 48.5601 N, 122.7501 W in 86 m of water from July 24, 2017 - July 27, 2017. The down-looking ADCP malfunctioned, and therefore there is no ADCP data at this site. The StableMoor400 was deployed in Rosario Strait mooring at 48.5800 N, 122.6597 W in 52 m of water from July 24, 2017 - July 27, 2017. Both buoys were deployed in Tacoma Narrows at 47.2766 N, 122.5466 W and 47.2769 N, 122.5471 W in 36 m of water from Nov 14, 2017 - Nov 17, 2017. Nortek Vector ADV measurements were recorded continuously at 16 Hz. Data was motion-corrected using the internal measurement unit (IMU) and external ADCP bottom-track data, bin-averaged into 10 minute bins, and then converted to the Principal (streamwise, cross-stream, vertical) coordinate system. Parameters include water velocity, turbulence intensity, turbulent kinetic energy (TKE) components, Reynolds shear stress components, TKE dissipation and production. Teledyne RDI Workhorse 1200 kHz ADCP measurements were recorded continuously at 2 Hz with bottom-track enabled. Water velocity was averaged into 10 minute bins and converted into the Principal coordinate system. One ADV with the highest quality motion-corrected was fully processed from each deployment site: the nose-mounted ADV at Bellingham Channel, the starboard-wing mounted ADV at Rosario Strait, and the port-wing mounted ADV at Tacoma Narrows. Raw data stored in this submission can be read using DOLfYN v1.3.1, available through the MHKiT python package, and was processed using Tsdat v0.7.5. Processed data are stored in netCDF4 format and can be easily viewed using the Linux "ncdump" command or read through the Xarray python package.

16 TIDAL AND WAVE POWER↗

Simulator study of the effect of control-system time delays on the occurrence of pilot-induced oscillations and on pilot tracking performance with a space-shuttle-orbiter configuration

Using a six degree-of-freedom motion-base simulator, the effect of control-system time delays on the occurrence of pilot-induced oscillations (PIO's) on the vehicle handling qualities and on pilot tracking performance for a landing-approach configuration of the Space Shuttle orbiter was studied. A linearized math model was employed which represented a 300-knot orbiter with almost all time delays removed. Additional time delays were then inserted following the pilot's hand-controller signals. Only pitch and roll commands were used for vehicle control. The simulation employed an air to air tracking task as a means of emphasizing PIO tendencies. Two astronauts, two research pilots, and one simulation engineer served as test subjects. Results showed that PIO's occurred when the amount of added time delay approximated that existing for the orbiter configuration flown in the approach and landing tests. Increasing the amount of delay increased PIO occurrences and resulted in degraded tracking performance. Decreasing the amount of time delay eliminated the PIO's.

Riley, D. R.↗

Lunar Scout Two spacecraft gravity experiment

Measurement of the gravity field of the Moon has a high science priority because of its implications for the internal structure and thermal history of the Moon, and it has a high priority for future exploration activities because of the influence of lunar gravity on spacecraft navigation and orbit maintenance. The current state of knowledge in the lunar gravity field (and the uncertainty in the knowledge) is based primarily on data accumulated from the Lunar Orbiter and Apollo programs. Data are sparse and emphasize the equatorial band (+/- 30 deg) on the near side of the Moon. There are no tracking data on the far side and only the Lunar Orbiter 5 provides a small amount of high inclination data. A host of gravity models developed from different combinations of tracking data have large discrepancies in their predictions of spacecraft motion and orbit lifetimes. There are also large disagreements in the Mercator projections of the gravity acceleration from each model, especially on the far side, where the contours tend to have no obvious relationship with the local topography. The science and engineering requirements for global gravity field mapping will be satisfied with continuous radio metric tracking of Lunar Scout 1 in a low polar orbit using the Deep Space Network and Lunar Scout 2 in a high elliptical orbit. The gravity field of the Moon will be mapped during the Scout Program using a two spacecraft concept. In the two spacecraft concept, one spacecraft is placed in a high altitude eccentric orbit while the second spacecraft is in a low altitude polar orbit. The gravity experiment requires a radio frequency that will permit two-way Doppler tracking between the spacecraft and the Deep Space Network (DSN). Both spacecraft carry NASA standard transponder systems for data transmission to Earth as well as for tracking and orbit determination. Data sufficient to produce a gravity field map could be acquired within one month with this system.

Cheng, Andrew F.↗

Ground-to-Ground Optical Communications Demonstration

A bidirectional horizontal-path optical link was demonstrated between Strawberry Peak (SP), Lake Arrowhead, California, and the JPL Table Mountain Facility (TMF), Wrightwood, California, during June and November of 1998. The 0.6-m telescope at TMF was used to broadcast a 4-beam 780-nm beacon to SP. The JPL-patented Optical Communications Demonstrator (OCD) at SP received the beacon, performed ne tracking to compensate for the atmosphere-induced beacon motion and retransmitted a 844-nm communications laser beam modulated at 40 to 500 Mb/s back to TMF. Characteristics of the horizontal-path atmospheric channel as well as performance of the optical communications link were evaluated. The normalized variance of the irradiance fluctuations or scintillation index delta2/I at either end was determined. At TMF where a single 844-nm beam was received by a 0.6-m aperture, the measured delta2/I covered a wide range from 0.07 to 1.08. A single 780-nm beam delta2/I measured at SP using a 0.09-m aperture yielded values ranging from 0.66 to 1.03, while a combination of four beams reduced the scintillation index due to incoherent averaging to 0.22 to 0.40. This reduction reduced the dynamic range of the fluctuations from 17 to 21 dB to 13 to 14 dB as compared with the OCD tracking sensor dynamic range of 10 dB. Predictions of these values also were made based on existing theories and are compared. Generally speaking, the theoretical bounds were reasonable. Discussions on the probability density function (PDF) of the intensity fluctuations are presented and compared with the measurements made. The lognormal PDF was found to agree for the weak scintillation regime as expected. The present measurements support evidence presented by earlier measurements made using the same horizontal path, which suggests that the aperture averaging effect is better than theoretically predicted.

Biswas, A.↗

Suitability of markerless EPID tracking for tumor position verification in gated radiotherapy

Purpose: To maximize the benefits of respiratory gated radiotherapy (RGRT) of lung tumors real-time verification of the tumor position is required. This work investigates the feasibility of markerless tracking of lung tumors during beam-on time in electronic portal imaging device (EPID) images of the MV therapeutic beam. Methods: EPID movies were acquired at ∼2 fps for seven lung cancer patients with tumor peak-to-peak motion ranges between 7.8 and 17.9 mm (mean: 13.7 mm) undergoing stereotactic body radiotherapy. The external breathing motion of the abdomen was synchronously measured. Both datasets were retrospectively analyzed inPortalTrack, an in-house developed tracking software. The authors define a three-step procedure to run the simulations: (1) gating window definition, (2) gated-beam delivery simulation, and (3) tumor tracking. First, an amplitude threshold level was set on the external signal, defining the onset of beam-on/-off signals. This information was then mapped onto a sequence of EPID images to generate stamps of beam-on/-hold periods throughout the EPID movies in PortalTrack, by obscuring the frames corresponding to beam-off times. Last, tumor motion in the superior-inferior direction was determined on portal images by the tracking algorithm during beam-on time. The residual motion inside the gating window as well as target coverage (TC) and the marginal target displacement (MTD) were used as measures to quantify tumor position variability. Results: Tumor position monitoring and estimation from beam's-eye-view images during RGRT was possible in 67% of the analyzed beams. For a reference gating window of 5 mm, deviations ranging from 2% to 86% (35% on average) were recorded between the reference and measured residual motion. TC (range: 62%–93%; mean: 77%) losses were correlated with false positives incidence rates resulting mostly from intra-/inter-beam baseline drifts, as well as sudden cycle-to-cycle fluctuations in exhale positions. Both phenomena can lead to considerable deviations (with MTD values up to a maximum of 7.8 mm) from the intended tumor position, and in turn may result in a marginal miss. The difference between tumor traces determined within the gating window against ground truth trajectory maps was 1.1 ± 0.7 mm on average (range: 0.4–2.3 mm). Conclusions: In this retrospective analysis of motion data, it is demonstrated that the system is capable of determining tumor positions in the plane perpendicular to the beam direction without the aid of fiducial markers, and may hence be suitable as an online verification tool in RGRT. It may be possible to use the tracking information to enable on-the-fly corrections to intra-/inter-beam variations by adapting the gating window by means of a robotic couch.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Internal-external correlation investigations of respiratory induced motion of lung tumors

In gated radiation therapy procedures, the lung tumor position is used directly (by implanted radiopaque markers) or indirectly (by external surrogate methods) to decrease the volume of irradiated healthy tissue. Due to a risk of pneumothorax, many clinics do not implant fiducials, and the gated treatment is primarily based on a respiratory induced external signal. The external surrogate method relies upon the assumption that the internal tumor motion is well correlated with the external respiratory induced motion, and that this correlation is constant in time. Using a set of data that contains synchronous internal and external motion traces, we have developed a dynamic data analysis technique to study the internal-external correlation, and to quantitatively estimate its underlying time behavior. The work presented here quantifies the time dependent behavior of the correlation between external respiratory signals and lung implanted fiducial motion. The corresponding amplitude mismatch is also reported for the lung patients studied. The information obtained can be used to improve the accuracy of tumor tracking. For the ten patients in this study, the SI internal-external motion is well correlated, with small time shifts and corresponding amplitude mismatches. Although the AP internal-external motion reveals larger time shifts than along the SI direction, the corresponding amplitude mismatches are below 5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster - 49: Assessment of Synchrony respiratory compensation error for CyberKnife liver treatment

The goal of this work is to quantify respiratory motion compensation errors for liver tumor patients treated by the CyberKnife system with Synchrony tracking, to identify patients with the smallest tracking errors and to eventually help coach patient’s breathing patterns to minimize dose delivery errors. The accuracy of CyberKnife Synchrony respiratory motion compensation was assessed for 37 patients treated for liver lesions by analyzing data from system logfiles. A predictive model is used to modulate the direction of individual beams during dose delivery based on the positions of internally implanted fiducials determined using an orthogonal x-ray imaging system and the current location of LED external markers. For each x-ray pair acquired, system logfiles report the prediction error, the difference between the measured and predicted fiducial positions, and the delivery error, which is an estimate of the statistical error in the model overcoming the latency between x-ray acquisition and robotic repositioning. The total error was calculated at the time of each x-ray pair, for the number of treatment fractions and the number of patients, giving the average respiratory motion compensation error in three dimensions. The 99{sup th} percentile for the total radial error is 3.85 mm, with the highest contribution of 2.79 mm in superior/inferior (S/I) direction. The absolute mean compensation error is 1.78 mm radially with a 1.27 mm contribution in the S/I direction. Regions of high total error may provide insight into features predicting groups of patients with larger or smaller total errors.

60 APPLIED LIFE SCIENCES↗

Assessing Impacts of Global Warming on Tropical Cyclone Tracks

A new approach is proposed to assess the possible impacts of the global climate change on tropical cyclone (TC) tracks in the western North Pacific (WNP) basin. The idea is based on the premise that the future change of TC track characteristics is primarily determined by changes in large-scale environmental steering flows. It is demonstrated that the main characteristics of the current climatology of TC tracks can be derived from the climatological mean velocity field of TC motion by using a trajectory model. The climatological mean velocity of TC motion, which is composed of the large-scale steering and beta drift, is determined on each grid of the basin. The mean beta drift is estimated from the best track data, and the mean large-scale steering flow is computed from the NCEP/NCAR reanalysis for the current climate state. The derived mean beta drift agrees well with the results of previous observational and numerical studies in terms of its direction and magnitude. The outputs of experiments A2 and B2 of the Geophysical Fluid Dynamics Laboratory (GFDL) R30 climate model suggest that the subtropical high will be persistently weak over the western part of the WNP or shift eastward during July-September in response to the future climate change. By assuming that the mean beta drift in the future climate state is unchanged, the change in the general circulation by 2059 will decrease the TC activities in the WNP, but favor a northward shift of typical TC tracks. As a result, the storm activities in the South China Sea will decrease by about 12%, while the Japan region will experience an increase of TCs by 12-15%. During the period of 2000-2029, the tropical storms that affect the China region will increase by 5-6%, but return to the current level during 2030-2059. It is also suggested that, during the period of 2030-2059 tropical storms will more frequently affect Japan and the middle latitude region of China given that the formation locations remain the same as in the current climate state.

Wu, Li-Guang↗

A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects are used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical {sup 18}F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was found to be stronger with abdominal signals than with thoracic signals (average Pearson correlation coefficients of 0.74 ± 0.17 and 0.45 ± 0.23, respectively). In all cases, except one, the abdominal respiratory motion preceded the thoracic motion—a maximum delay of approximately 600 ms was detected. Conclusions: The method provides motion information with sufficiently high spatial and temporal resolution. Thus, it enables meaningful analysis in the form of comparisons between amplitudes and phase shifts of signals from different regions. In combination with a large field-of-view, as given by combining the data of two Kinect cameras, it yields surface representations that might be useful in the context of motion correction and motion modeling.

60 APPLIED LIFE SCIENCES↗

On state estimation and fusion with elliptical constraints

We consider tracking of a target with elliptical nonlinear constraints on its motion dynamics. The state estimates are generated by sensors and sent over long-haul links to a remote fusion center for fusion. We show that the constraints can be projected onto the known ellipse and hence incorporated into the estimation and fusion process. In particular, two methods based on (i) direct connection to the center, and (ii) shortest distance to the ellipse are discussed. A tracking example is used to illustrate the tracking performance using projection-based methods with various fusers in the lossy long-haul tracking environment.

Rao, Nageswara S.↗

Manual Crew Override of Vehicle Landings Following G-Transitions

BACKGROUND Manual control during exploration spaceflight consists of both planned automated supervisory control and unplanned crew override. This crew override capability is critical to enable overall mission success during landing contingencies. However, the introduction of manual override capabilities must be implemented to enable crews to mitigate risks introduced by human error. Adaptive changes in the sensorimotor system can manifest during g-transitions as spatial disorientation. While training and landing aids enable successful landing through disorientation, these adaptive changes may increase cognitive demand that needs to be accounted for in the manual control strategy. It is important to characterize these effects as soon as possible following the G-transition to develop appropriate countermeasures. METHODS In this study, we will examine operational piloting tasks following International Space Station (ISS) missions in a simulated lunar landing using a six-degree-of-freedom (6DOF) motion base. The motion-based simulation will be implemented in our laboratory at the Johnson Space Center (JSC) and will be available within hours following the return from commercial crew landings. The primary goals of this study are (1) to understand the impact of spaceflight on crew ability to perform manual crew override tasks, (2) to examine how adaptive changes in vestibular and cognitive function relate to changes in manual crew override proficiency, and (3) compare performance during late “just-in-time” on-board training with early post-flight crew performance. The impact of spaceflight on piloting capability will be assessed from pre- versus post-flight changes in crewmembers assigned to either short duration (< 30 day) or long duration (~6- month) missions to the International Space Station (ISS). Individual differences in post-flight vestibular and cognitive changes include motion sickness reports, measures of tilt motion perception accuracy and precision, and dual-task tracking. During the 6DOF lunar simulation, the crew will manually takeover attitude and rate-of-descent to the nominal or re-designated landing aim point during the approach phase. The outcome measures for the lunar crew override tasks will be the percent time maintaining actual vehicle states, e.g., attitude and rate-of-descent, within recommended guidance during the landing approach, number and maximum deviation outside limits, and root mean square error (RMSE). Given that “just-in-time” (JIT) training is an operational expectation for the Human Landing System (HLS) program, all participants will perform late inflight JIT training for each manual crew override task in which they will participate. Crew proficiency will be captured inflight during JIT training that will be implemented on a laptop with hand controllers to allow the crewmember to practice the landing task procedures like the approach implemented for JIT training with Shuttle landing and ISS telerobotic tasks. COUNTERMEASURE UPDATES The lunar lander simulation has been implemented onto a two-laptop display system where subjects select from alternative landing points, based upon avoiding hazards that the on-board system identifies during the landing. The subject makes inputs using a rotational hand controller (i.e., joystick) and a translational hand controller, which are processed by simulated vehicle dynamics to update the vehicle attitude and rate of descent. Subjects will utilize a combination of flight, situation, and status displays to monitor the state of the simulated vehicle. The simulation exports tilt and translation movements to a 6DOF motion base synced to visual movements and provides representative vestibular cues to the subject while performing the task inside an enclosed cabin featuring a simulated lunar out-the-window view and a heads-down lander cockpit view. RELEVANCE This project will deliver an operational demonstration of crew override capability following spaceflight and identify potential deficits that may require remediation. Comparison of individual vestibular and cognitive changes with crew override performance will help better characterize the manual control risks associated with sensorimotor alterations. The inclusion of “just-in-time” on-board training will ensure we are characterizing changes in override proficiency with this expected countermeasure in place. ACKNOWLEDGEMENTS: The authors acknowledge contributions from Draper, HLS Joint Test Panel, Crew HLS Interfaces for Piloting Working Group, and Dynamic Skills Trainer (DST) Lab toward the development of the lunar landing simulation. This project is funded by the Human Health Countermeasures Element.

Austin M Bollinger↗