Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams

Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans from clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported D{sub W} and D{sub Wa} than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (D{sub W,middle}) and averaged over the low attenuating region of lung (D{sub W,regional}) were statistically significantly higher than correlations of normalized lung dose with ED. Conclusions: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.

60 APPLIED LIFE SCIENCES↗

Adaptive approximation of higher order posterior statistics

Filtering is an approach for incorporating observed data into time-evolving systems. Instead of a family of Dirac delta masses that is widely used in Monte Carlo methods, we here use the Wiener chaos expansion for the parametrization of the conditioned probability distribution to solve the nonlinear filtering problem. The Wiener chaos expansion is not the best method for uncertainty propagation without observations. Nevertheless, the projection of the system variables in a fixed polynomial basis spanning the probability space might be a competitive representation in the presence of relatively frequent observations because the Wiener chaos approach not only leads to an accurate and efficient prediction for short time uncertainty quantification, but it also allows to apply several data assimilation methods that can be used to yield a better approximate filtering solution. The aim of the present paper is to investigate this hypothesis. We answer in the affirmative for the (stochastic) Lorenz-63 system based on numerical simulations in which the uncertainty quantification method and the data assimilation method are adaptively selected by whether the dynamics is driven by Brownian motion and the near-Gaussianity of the measure to be updated, respectively.

97 MATHEMATICS AND COMPUTING↗

A particle-in-cell Monte Carlo code for electron beam ion source simulation

FAR-TECH, Inc., has developed a particle-in-cell Monte Carlo code (EBIS-PIC) to model ion motions in an electron beam ion source (EBIS). First, a steady state electron beam is simulated by the PBGUNS code (see http://far-tech.com/pbguns/index.html). Then, the injected primary ions and the ions from the background neutral gas are tracked in the trapping region using Monte Carlo method. Atomic collisions and Coulomb collisions are included in the EBIS-PIC model. The space charge potential is updated by solving the Poisson equation each time step. The preliminary simulation results are presented and compared with BNL electron beam test stand (EBTS) fast trapping experiments.

43 PARTICLE ACCELERATORS↗

Under-Prediction of Localized Tally Uncertainties in Monte Carlo Eigenvalue Calculations

Modeling and simulation using Monte Carlo methods is widely used in nuclear reactor criticality benchmarking applications. However, obtaining good statistics not only takes a large amount of computational time, but it has been shown that localized tally uncertainties may be under-predicted by a factor of five or more in select cases. The primary components of this under-prediction include poor sampling due to improper source convergence and cycle-to-cycle correlations in the fission source. Additional components relate to the flux shape and the size of the tally cells. These issues must be understood and dealt with in order to support the practical use of modern Monte Carlo software packages.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Combination of X-ray crystallography, SAXS and DEER to obtain the structure of the FnIII-3, 4 domains of integrin α6β4

The structure of the FnIII-3, 4 region of integrin β4 was solved using a hybrid approach that combines crystallographic structures, SAXS, DEER and molecular modelling. The structure helps in understanding how integrin β4 might bind to other hemidesmosomal proteins and mediate signalling. Integrin α6β4 is a major component of hemidesmosomes that mediate the stable anchorage of epithelial cells to the underlying basement membrane. Integrin α6β4 has also been implicated in cell proliferation and migration and in carcinoma progression. The third and fourth fibronectin type III domains (FnIII-3, 4) of integrin β4 mediate binding to the hemidesmosomal proteins BPAG1e and BPAG2, and participate in signalling. Here, it is demonstrated that X-ray crystallography, small-angle X-ray scattering and double electron–electron resonance (DEER) complement each other to solve the structure of the FnIII-3, 4 region. The crystal structures of the individual FnIII-3 and FnIII-4 domains were solved and the relative arrangement of the FnIII domains was elucidated by combining DEER with site-directed spin labelling. Multiple structures of the interdomain linker were modelled by Monte Carlo methods complying with DEER constraints, and the final structures were selected against experimental scattering data. FnIII-3, 4 has a compact and cambered flat structure with an evolutionary conserved surface that is likely to correspond to a protein-interaction site. Finally, this hybrid method is of general application for the study of other macromolecules and complexes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray emission cross sections following Ar{sup 18+} charge-exchange collisions on neutral argon: The role of the multiple electron capture

X-ray emission originating in charge-exchange collisions between Ar{sup 18+} and neutral argon is studied at impact energies of 5-4000 eV/amu by means of the classical trajectory Monte Carlo method (CTMC). Line emission and charge-exchange cross sections obtained from different CTMC versions based on the one-active electron approximation are contrasted among themselves and against the results obtained by means of a three-active electron code that lets us infer the role of multiple electron capture. The present results are compared to the recent experimental data available from the EBIT groups operating at Livermore, NIST, and Berlin. We were not able to reconcile the major difference in x-ray emission cross sections obtained from in situ measurements made in EBIT, versus those made in an exterior, field-free collision chamber using ions extracted from the EBIT. Our calculations support the extracted beam results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopic investigation of the spatiotemporal dynamics of an electric field in plasma of a beam-type high-voltage discharge in helium

In the present work, a method of determining the spatiotemporal characteristics of the electric field strength in an accelerating gap and a plasma flare of a beam-type high-voltage pulsed discharge in He at moderate pressure is presented. The method is based on spectroscopic data on the Stark splitting of π-components of He 2P–4Q transitions; Q = D(4921.93 Å), F(4920.35 Å) in the near-cathode region of the discharge and on the spatiotemporal characteristics of intensities of He(2s{sup 1}S–3p{sup 1}P{sup 0}) spectral lines with λ = 5015 Å and He{sup +}(3d–4f) spectral lines with λ = 4685 Å measured experimentally and calculated from the data of statistical simulation of the electron kinetics by the Monte Carlo method. The shape and strength of the electric field of the space charge in the interelectrode gap and the drift region of the discharge are estimated. It is demonstrated that the electric field created by the current pulse of uncompensated space charge in the near-anode region changes the discharge regime and causes degradation of the electron beam in the plasma flare. It is established that the flux of secondary electrons from the drift region to the anode has significant effect on the radiation intensity distribution in this region of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of 5- and 10-year-old pediatric phantoms based on polygon mesh surfaces

Purpose: The purpose of this study is the development of reference pediatric phantoms for 5- and 10-year-old children to be used for the calculation of organ and tissue equivalent doses in radiation protection. Methods: The study proposes a method for developing anatomically highly sophisticated pediatric phantoms without using medical images. The 5- and 10-year-old male and female phantoms presented here were developed using 3D modeling software applied to anatomical information taken from atlases and textbooks. The method uses polygon mesh surfaces to model body contours, the shape of organs as well as their positions, and orientations in the human body. Organ and tissue masses comply with the corresponding data given by the International Commission on Radiological Protection (ICRP) for the 5- and 10-year-old reference children. Bones were segmented into cortical bone, spongiosa, medullary marrow, and cartilage to allow for the use of micro computer tomographic ({mu}CT) images of trabecular bone for skeletal dosimetry. Results: The four phantoms, a male and a female for each age, and their organs are presented in 3D images and their organ and tissue masses in tables which show the compliance of the ICRP reference values. Dosimetric data, calculated for the reference pediatric phantoms by Monte Carlo methods were compared with corresponding data from adult mesh phantoms and pediatric stylized phantoms. The comparisons show reasonable agreement if the anatomical differences between the phantoms are properly taken into account. Conclusions: Pediatric phantoms were developed without using medical images of patients or volunteers for the first time. The models are reference phantoms, suitable for regulatory dosimetry, however, the 3D modeling method can also be applied to medical images to develop patient-specific phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gyrocenter-gauge kinetic algorithm for high frequency waves in magnetized plasmas

A kinetic simulation algorithm for high-frequency electromagnetic waves has been developed based on the gyrocenter-gauge kinetic theory. The magnetized plasma system is simulated in the gyrocenter coordinate system. The gyrocenter distribution function F is sampled on the gyrocenter, parallel velocity, and magnetic moment coordinates. The gyrocenter-gauge function S is sampled on the Kruskal rings and shares the first five coordinates with F. The moment integral of pullback transformation is directly calculated using the Monte Carlo method and an explicit difference scheme for Maxwell's equations in terms of potentials is adopted. The new algorithm has been successfully applied to the simulation studies of high frequency extraordinary wave, electron Bernstein wave, and the mode conversion process between the extraordinary wave and the electron Bernstein wave in inhomogeneous plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Risk Assessment and Management of Uranium Mill Tailings Legacies - 17508

exploitation activities took place at 61 sites. The great majority of these mining sites are located in central-east Portugal, including the Urgeirica mine that was the most important uranium deposit exploited in the country. The mining activities at this site generated 1.6 million m{sup 3} of radioactive wastes disposed in an open air area originating the largest radioactive tailings pile of the country. The environmental remediation of the Urgeirica site was one of the main priorities of the national plan for the rehabilitation of former uranium mining sites. Site remediation, that included the mine industrial area with several support infrastructures and a processing plant, was executed between 2006 and 2008 (1. phase) and between 2008 and 2014 (2. phase). Nevertheless, the environmental rehabilitation of the Portuguese uranium legacies sites is not yet concluded. One of the last largest mining complexes, the Quinta do Bispo open pit, is scheduled to be rehabilitated only in 2020. This work presents a study to evaluate the environmental impacts from the uranium mill tailings legacies before and after the remediation works, focusing on two different approaches: a deterministic methodology for dose assessment and a probabilistic methodology with the Monte Carlo method to estimate the incremental lifetime risk. Probabilistic distributions of the input parameters were used in the risk calculation approach. The methodology for dose and risk assessments may be applied to other sites that are still under intervention and the results may be used to prioritize the remediation stages. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adjoint and Importance in Monte Carlo Application

The use of the Monte Carlo method for the study of deep penetration of radiation into and through shields entails the use of sophisticated methods of variance reduction to make such calculations economical or even feasible. This paper presents an exposition of the most useful methods of variance reduction. The exposition is unified by consistent exploitation of adjoint formulations to estimate expected values, as in previous work, and further to evaluate the variance of the resulting estimates., The connection between adjoint formulations and the choice of biasing schemes is also investigated. In particular, it is shown that the value function (the solution of the integral equation of the adjoint formulation) is always a good choice for importance function biasing; a sharp upper bound, independent of the particular problem, is found for the resulting variance. Predicted (analytic) and experimental (Monte Carlo) results are also given for a simple one-dimensional problem.

DIFFERENTIAL EQUATIONS↗

Data for secondary-electron production from ion precipitation at Jupiter III: Target and projectile processes in H{sup +}, H, and H{sup −} + H{sub 2} collisions

To extend the range of data required for modeling the secondary-electron production from ion precipitation into the upper atmosphere of Jupiter, inelastic processes for collisions of 1 keV to 25 MeV H{sup +}, H, and H{sup −} with H{sub 2} are considered. As in other work treating the dominant heavy-ion species of magnetospheric origin, O and S ions (Schultz et al., 2017, 2019; Gharibnejad et al., 2019) the classical trajectory Monte Carlo method is employed to describe the secondary-electron-producing channels (single and double ionization, transfer ionization, and single and double stripping) as well as the other inelastic channels (single and double charge transfer and projectile and target excitation) required to model the energy loss and charge state evolution of the precipitating ions in their passage through the atmospheric gas. Data is described and tabulated both as directly obtained from these calculations and normalized to widely accepted recommended values (Hunter et al., 1990) for channels for which recommendations exist. As in the previous work, the overall accuracy and completeness of the data presented is verified by use of a Monte Carlo ion-transport simulation to obtain the stopping power and ion-fraction populations as a function of impact energy in comparison with accepted values. The addition of the present data to models of secondary-electron production in Jupiter’s atmosphere improves such model’s ability to interpret in situ observations of the precipitating ions’ effect by the spacecraft Juno as well as enhancing the physical reality of models of the coupling of the Jovian magnetosphere, ionosphere, and atmosphere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo performance on the x-ray converter thickness in digital mammography using software breast models

Purpose: In x-ray mammography, some of the components that play significant role to early diagnosis are the x-ray source, the breast composition as well as the composition of the x-ray converter. Various studies have previously investigated separately the influence of breast characteristics and detector configuration on the optimization of mammographic imaging systems. However, it is important to examine the combined effect of both components in improving the signal transfer properties in mammography systems of the mammograms. In the present study, the authors compared and evaluated x-ray converters using software breast models and realistic mammographic spectra in terms of: (a) zero-frequency detective quantum efficiency (DQE) and (b) sensitivity. The impact of x-ray converter thickness on contrast threshold (C{sub TH}) for observer assessment, based on the Rose model, was demonstrated as well. Methods: Monte Carlo techniques were applied to simulate the x-ray interactions within the software breast phantoms and thereafter within the detective medium. Simulations involved: (a) two mammographic x-ray spectra: 28 kV Mo, 0.030 mm Mo, and 32 kV W, 0.050 mm Rh of different entrance surface air kerma (ESAK: 3-7 mGy), (b) realistic breast models (dense and fatty) and (c) x-ray converter materials most frequently considered in investigations on energy integrating digital mammography detectors: the Gd{sub 2}O{sub 2}S:Tb granular phosphor, the CsI:Tl structured phosphor, and the a-Se photoconductive layer. Detector material thickness was considered to vary in the range from 50 mg/cm{sup 2} up to 150 mg/cm{sup 2}. Results: The Monte Carlo study showed that: (a) the x-ray beam becomes less penetrating after passing through dense breasts leading to higher values of zero-frequency DQE of the x-ray imaging converters and improved C{sub TH} values in all cases considered, (b) W/Rh target/filter combination results in improved C{sub TH} values at higher ESAK values, and (c) a-Se shows higher zero-frequency DQE values than the phosphor-based converters, Gd{sub 2}O{sub 2}S:Tb and CsI:Tl. However, thicker layers of CsI:Tl could be comparable to a-Se layers achieving approximately 27.6% C{sub TH} improvement at a thickness of 150 mg/cm{sup 2}. Conclusions: The present Monte Carlo investigation indicates that in the energy range employed in mammography, an upper limit, approximately 100 mg/cm{sup 2}, should be considered in the development of thicker a-Se converters. On the other hand, above this thickness value, CsI:Tl converter could improve its imaging performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

'Magic numbers' in the melting of a cluster of point charges on a sphere

The thermodynamic properties of a cluster of point Coulomb charges on a sphere have been analyzed using the Monte Carlo method for the number of charges 20 {<=} N {<=} 90. The ground state of the system of charges is described in the model of a closed quasi-two-dimensional triangular lattice with topological defects. We have determined the dependence of the Lindeman parameter {delta}{sub L} of this system on N and on the dimensionless parameter, which is proportional to the temperature T and to the radius R of the cluster, where element is the dielectric constant of the medium and the charge of a particle. The 'magic numbers,' i.e., the N values, for which the melting point of the closed triangular lattice of charges is much higher than those for neighboring N values, have been found. The evolution of the lattice-melting mechanisms with an increase in the number of charges N in a mesoscopic cluster has been analyzed. For N {<=} 32, the melting of the lattice does not involve dislocations (nontopological melting); this behavior of the mesoscopic system of charges on the sphere differs from the behavior of the extended planar two-dimensional system. At N {>=} 50, melting is accompanied by the formation of dislocations. The mechanism of dislocation-free non-topological melting of a closed lattice, which occurs at small N values and is associated with the cooperative rotational motion of 'rings' of particles, has been analyzed. The model has various implementations in the mesoscopic region; in particular, it describes the system of electrons over the liquid-helium cluster, the liquid-helium cluster with incorporated charged particles, a multielectron bubble in liquid helium, a charged quantum dot, etc.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-224: Is Monte Carlo Dose Calculation Method Necessary for Cyberknife Brain Treatment Planning?

Purpose: To study the dosimetric difference resulted in using the pencil beam algorithm instead of Monte Carlo (MC) methods for tumors adjacent to the skull. Methods: We retrospectively calculated the dosimetric differences between RT and MC algorithms for brain tumors treated with CyberKnife located adjacent to the skull for 18 patients (total of 27 tumors). The median tumor sizes was 0.53-cc (range 0.018-cc to 26.2-cc). The absolute mean distance from the tumor to the skull was 2.11 mm (range - 17.0 mm to 9.2 mm). The dosimetric variables examined include the mean, maximum, and minimum doses to the target, the target coverage (TC) and conformality index. The MC calculation used the same MUs as the RT dose calculation without further normalization and 1% statistical uncertainty. The differences were analyzed by tumor size and distance from the skull. Results: The TC was generally reduced with the MC calculation (24 out of 27 cases). The average difference in TC between RT and MC was 3.3% (range 0.0% to 23.5%). When the TC was deemed unacceptable, the plans were re-normalized in order to increase the TC to 99%. This resulted in a 6.9% maximum change in the prescription isodose line. The maximum changes in the mean, maximum, and minimum doses were 5.4 %, 7.7%, and 8.4%, respectively, before re-normalization. When the TC was analyzed with regards to target size, it was found that the worst coverage occurred with the smaller targets (0.018-cc). When the TC was analyzed with regards to the distance to the skull, there was no correlation between proximity to the skull and TC between the RT and MC plans. Conclusions: For smaller targets (< 4.0-cc), MC should be used to re-evaluate the dose coverage after RT is used for the initial dose calculation in order to ensure target coverage.

60 APPLIED LIFE SCIENCES↗

Retroreflection of Optical Radiation from Ellipsoidal-Porous Surfaces

The retroreflection of optical radiation from surfaces with roughness in the form of ellipsoidal pores and two-level roughness in the form of convex ellipsoids with elliptical-porous surfaces is studied using the ROKS-RG Monte-Carlo method software in the geometrical-optics approximation. The dependence of the retroreflection phase function on the parameters of bodies that simulates the rough surface is analyzed. It is shown that the angular dependence of the retroreflection from porous rough surfaces with arbitrarily oriented pores and the aspect ratio higher than unity is a pronounced peak with concave sides at all incidence angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculating effective diffusivities in the limit of vanishing molecular diffusion

In this paper we study the problem of the numerical calculation (by Monte Carlo methods) of the effective diffusivity for a particle moving in a periodic divergent-free velocity field, in the limit of vanishing molecular diffusion. In this limit traditional numerical methods typically fail, since they do not represent accurately the geometry of the underlying deterministic dynamics. We propose a stochastic splitting method that takes into account the volume-preserving property of the equations of motion in the absence of noise, and when inertial effects can be neglected. An extension of the method is then proposed for the cases where the noise has a non-trivial time-correlation structure and when inertial effects cannot be neglected. The method of modified equations is used to explain failings of Euler-based methods. The new stochastic geometric integrators are shown to outperform standard Euler-based integrators. Various asymptotic limits of physical interest are investigated by means of numerical experiments, using the new integrators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions

Certain brachytherapy dose distributions, such as those for LDR prostate implants, are readily modeled by treatment planning systems (TPS) that use the superposition principle of individual seed dose distributions to calculate the total dose distribution. However, dose distributions for brachytherapy treatments using high-Z shields or having significant material heterogeneities are not currently well modeled using conventional TPS. The purpose of this study is to establish a new treatment planning technique (Tufts technique) that could be applied in some clinical situations where the conventional approach is not acceptable and dose distributions present cylindrical symmetry. Dose distributions from complex brachytherapy source configurations determined with Monte Carlo methods were used as input data. These source distributions included the 2 and 3 cm diameter Valencia skin applicators from Nucletron, 4-8 cm diameter AccuBoost peripheral breast brachytherapy applicators from Advanced Radiation Therapy, and a 16 mm COMS-based eye plaque using {sup 103}Pd, {sup 125}I, and {sup 131}Cs seeds. Radial dose functions and 2D anisotropy functions were obtained by positioning the coordinate system origin along the dose distribution cylindrical axis of symmetry. Origin:tissue distance and active length were chosen to minimize TPS interpolation errors. Dosimetry parameters were entered into the PINNACLE TPS, and dose distributions were subsequently calculated and compared to the original Monte Carlo-derived dose distributions. The new planning technique was able to reproduce brachytherapy dose distributions for all three applicator types, producing dosimetric agreement typically within 2% when compared with Monte Carlo-derived dose distributions. Agreement between Monte Carlo-derived and planned dose distributions improved as the spatial resolution of the fitted dosimetry parameters improved. For agreement within 5% throughout the clinical volume, spatial resolution of dosimetry parameter data {<=}0.1 cm was required, and the virtual brachytherapy source data set included over 5000 data points. On the other hand, the lack of consideration for applicator heterogeneity effect caused conventional dose overestimates exceeding an order of magnitude in regions of clinical interest. This approach is rationalized by the improved dose estimates. In conclusion, a new technique was developed to incorporate complex Monte Carlo-based brachytherapy dose distributions into conventional TPS. These results are generalizable to other brachytherapy source types and other TPS.

61 RADIATION PROTECTION AND DOSIMETRY↗