Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Validation of a DIXON-based fat quantification technique for the measurement of visceral fat using a CT-based reference standard

Purpose: The purpose of the study is to determine whether a novel semi-automated DIXON-based fat quantification algorithm can reliably quantify visceral fat using a CT-based reference standard. Methods: This was an IRB-approved retrospective cohort study of 27 subjects who underwent abdominopelvic CT within 7 days of proton density fat fraction (PDFF) mapping on a 1.5T MRI. Cross-sectional visceral fat area per slice (cm{sup 2}) was measured in blinded fashion in each modality at intervertebral disc levels from T12 to L4. CT estimates were obtained using a previously published semi-automated computational image processing system that sums pixels with attenuation − 205 to − 51 HU. MR estimates were obtained using two novel semi-automated DIXON-based fat quantification algorithms that measure visceral fat area by spatially regularizing non-uniform fat-only signal intensity or de-speckling PDFF 2D images and summing pixels with PDFF ≥ 50%. Pearson’s correlations and Bland–Altman analyses were performed. Results: Visceral fat area per slice ranged from 9.2 to 429.8 cm{sup 2} for MR and from 1.6 to 405.5 cm{sup 2} for CT. There was a strong correlation between CT and MR methods in measured visceral fat area across all studied vertebral body levels (r = 0.97; n = 101 observations); the least (r = 0.93) correlation was at T12. Bland–Altman analysis revealed a bias of 31.7 cm{sup 2} (95% CI [− 27.1]–90.4 cm{sup 2}), indicating modestly higher visceral fat assessed by MR. Conclusion: MR- and CT-based visceral fat quantification are highly correlated and have good cross-modality reliability, indicating that visceral fat quantification by either method can yield a stable and reliable biomarker.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early response evaluation of neoadjuvant therapy with PET/MRI to predict resectability in patients with adenocarcinoma of the esophagogastric junction

Study design and purpose: Positron emission tomography (PET)/magnetic resonance imaging (MRI) is a new modality that has showed promising results for various clinical indications. Currently, evaluation of neoadjuvant therapy (NT) among patients with adenocarcinoma of the esophagogastric junction has primarily been reserved for PET/computed tomography. Our aim was to evaluate if early response evaluation by PET/MRI is a feasible method to predict resectability. Methods and materials: Patients with untreated adenocarcinoma of the esophagogastric junction (Siewert types I/II) and fit for NT with no contraindications for PET/MRI were considered eligible. A baseline scan was performed prior to NT induction and an evaluation scan 3 weeks later. For histopathological response evaluation, the Mandard tumor regression grade score was applied. Response on PET/MRI was evaluated with Response Evaluation Criteria in Solid Tumors (RECIST 1.1), and change in ADC and SUV{sub max} values. Results: Twenty-eight patients were enrolled, and 22 completed both scans and proceeded to final analyses. Seventeen patients were found resectable versus five who were found unresectable. PET/MRI response evaluation had a sensitivity 94%, specificity 80%, and AUC = 0.95 when predicting resectability in patients with adenocarcinoma of the esophagogastric junction. No association with histopathological response (tumor regression grade) was found nor was RECIST correlated with resectability. Conclusion: Response evaluation using PET/MRI was a feasible method to predict resectability in patients with adenocarcinoma of the esophagogastric junction in this pilot study. However, larger studies are warranted to justify the use of the modality for this indication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodality imaging of small bowel neoplasms

Although the small intestine accounts for over 90% of the surface area of the alimentary tract, tumors of the small intestine represent less than 5% of all gastrointestinal tract neoplasms. Common small bowel tumors typically are well evaluated with cross-sectional imaging modalities such as CT and MR, but accurate identification and differentiation can be challenging. Differentiating normal bowel from abnormal tumor depends on imaging modality and the particular technique. While endoscopic evaluation is typically more sensitive for the detection of intraluminal tumors that can be reached, CT and MR, as well as select nuclear medicine studies, remain superior for evaluating extraluminal neoplasms. Understanding the imaging characteristics of typical benign and malignant small bowel tumors is critical, because of overlapping features and associated secondary complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI of cervical cancer with a surgical perspective: staging, prognostic implications and pitfalls

Learning objectives: Magnetic resonance imaging (MRI) of the pelvis is the most reliable imaging modality for staging, treatment planning, and follow-up of cervical cancer; and its findings may now be incorporated into the International Federation of Gynecology and Obstetrics Federation (FIGO) 2018 clinical staging of cervical cancer. It is imperative that radiologists are familiar with the imaging appearance of the different stages of cervical cancer as well as the post-treatment changes and imaging pitfalls given the respective clinical manifestations, treatment regimens, and prognosis of an accurate diagnosis. In addition to the different stages of cervical cancer, we address the imaging techniques for diagnosis, staging and treatment implications as well as the changes of the new FIGO staging system. Background: The use of MRI to diagnose and stage cervical cancer is steadily increasing and the new FIGO stagi ng system, previously based on clinical examination, now allows the staging or change of staging based on the imaging findings. MRI can evaluate the extent of disease because of its excellent contrast resolution for pelvic tissues and organs, high accuracy and detailed elaboration of the cervical/uterovaginal anatomy. Content: Relevant anatomy, including normal MRI appearance of the cervix, parametria and pelvic ligaments; different stages of cervical cancer on MRI with prognostic and therapeutic implications; MRI sequences, other imaging modalities used in the staging and follow-up, treatment of different stages and the appearance of the cervix and cervical cancer post-treatment. Since clinical implications and therapeutic strategies for cervical cancer treatment vary tremendously according to degree of tumor extension, familiarity with relevant MRI techniques and findings is essential for radiologists. Summary: It is important that radiologists interpreting pelvic MRI are aware with the different stages of cervical cancer to provide useful information regarding treatment and prognosis. Pitfalls regarding the interpretation of tumor extension can interfere with an accurate diagnosis and have significant therapeutic implications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mucinous rectal cancer: concepts and imaging challenges

Rectal adenocarcinoma with mucinous components is an uncommon type of rectal cancer with two distinct histologic subtypes: mucinous adenocarcinoma and signet-ring cell carcinoma. Mucin can also be identified as pattern of response after neoadjuvant treatment. On imaging modalities, mucin typically demonstrates high signal intensity on T2-weighted images, low attenuation on computed tomography, and may be negative on 18-fluorodeoxyglucose positron emission tomography. After neoadjuvant CRT, cellular and acellular mucin share similar imaging features, and differentiating them is currently the main challenge faced by radiologists. Radiologists should be aware of pros, cons, and limitations of each imaging modality in the primary staging and restaging to avoid misinterpretation of the radiological findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A prospective feasibility study evaluating the role of multimodality imaging and liquid biopsy for response assessment in locally advanced rectal carcinoma

Purpose: Colorectal cancer is a commonly encountered disease that poses several diagnostic and therapeutic challenges. The inherent heterogeneity of tumor biology and propensity to relapse despite “curative” resection pose significant challenges with regard to response assessment. Although MR imaging already plays a key role in primary staging of patients with rectal carcinoma, its reliability in restaging after neoadjuvant therapy is debatable (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). Therefore, there is significant interest in developing additional methods which may improve diagnostic accuracy. This study aims to evaluate the role of multimodality imaging and liquid biopsy in therapeutic response assessment. Methods: Seventeen patients were enrolled into the study over a span of 24 months. All underwent hybrid PET-MRI and CT-perfusion (CT-P), prior to and following neoadjuvant therapy for locally advanced rectal carcinoma. Twelve of the 17 patients also underwent liquid biopsy, which consisted of blood sampling and analysis of circulating tumor cells (CTCs) and extracellular vesicles (EVs), including cell fragments and microparticles (MPs), using the Cell Search System (Menarini Silicon Biosystems). SUV, DWI, and ADC were calculated during PET-MRI, and several parameters were evaluated during CT-perfusion, including average perfusion, blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), contrast extraction efficiency (E), and K-trans (K). Changes observed pre- and post-neoadjuvant therapy in each modality were compared to tumor response at histopathology using a modified Ryan tumor regression grading system. Results: Of the 17 patients included in the study, 14 were classified as non-responders, and 3 were classified as responders as determined by the modified Ryan Tumor Regression Grade (TRG) scoring system (Van der broek et al. in Dis Colon Rectum 60(3):274–283, 2017). When combined, blood markers and CT-P parameters (mean transit time (MTT), K-trans, and permeability-surface area product (PS)) produced the strongest models (p < 0.01). PET (SUV measurement) combined with CT-P-derived K-trans produced a marginally significant (p = 0.057) model for predicting response. MRI-derived ADC value did not provide a significant model for response prediction. Conclusion: A model of CT-P parameters plus liquid biopsy more accurately predicts tumor response than PET-MRI, CT-P alone, or liquid biopsy alone. These results suggest that in the evaluation of treatment response, liquid biopsy could provide additional information to functional imaging modalities such as CT-P and should therefore be explored further in a trial with larger sample size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Opportunities and Challenges in the Design and Analysis of Biomass Supply Chains

The biomass supply chain is one of the most critical elements of large-scale bioenergy production and in many cases a key barrier for procuring initial funding for new developments on specific energy crops. Most productions rely on complex transforming chains linked to feed and food markets. The term 'supply chain' covers various aspects from cultivation and harvesting of the biomass, to treatment, transportation, and storage. After energy conversion, the product must be delivered to final consumption, whether it is in the form of electricity, heat, or more tangible products, such as pellets and biofuels. Effective supply chains are of utmost importance for bioenergy production, as biomass tends to possess challenging seasonal production cycles and low mass, energy and bulk densities. Additionally, the demand for final products is often also dispersed, further complicating the supply chain. The goal of this paper is to introduce key components of biomass supply chains, examples of related modeling applications, and if/how they address aspects related to environmental metrics and management. The paper will introduce a concept of integrated supply systems for sustainable biomass trade and the factors influencing the bioenergy supply chain landscape, including models that can be used to investigate the factors. Our paper will also cover various aspects of transportation logistics, ranging from alternative modal and multi-modal alternatives to introduction of support tools for transportation analysis. Lastly, gaps and challenges in supply chain research are identified and used to outline research recommendations for the future direction in this area of study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dynamic Computed Tomography Angiography: Role in the Evaluation of Popliteal Artery Entrapment Syndrome

This study reviews our experience with dynamic computed tomographic angiography (CTA) as an imaging modality in the evaluation of popliteal artery entrapment syndrome (PAES). Eight patients with surgically proven PAES were included in this study. Dynamic CTA studies performed with the feet in neutral and plantar flexed positions were reviewed for the detailed anatomy of the region and to define the location and extent of the stenosis, occlusions and collateral circulation. These findings were compared with intraoperative observations. CTA provided adequate angiographic and anatomic information required to arrive at the diagnosis and make a surgical decision. Thirteen limbs were affected in eight patients. There was popliteal artery occlusion in four limbs, stenosis at rest that was accentuated on stress imaging in two limbs, and patent popliteal artery with marked stenosis on stress imaging in seven limbs. Long-segment stenosis was seen in functional entrapment compared to short-segment stenosis in anatomic PAES. Anteroposterior compression of the popliteal artery in anatomic PAES unlike the side-to-side compression in functional PAES was a unique observation in this study. The CTA and surgical characterisation and classification of PAES matched in all the patients, except for misinterpretation of compressing fibrous bands as accessory slips of muscles in three limbs. In conclusion, dynamic CTA is a robust diagnostic tool that provides clinically relevant information and serves as a rapidly performed and easily available 'one-stop-shop' imaging modality in the management of PAES.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent 'pores' in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance

PurposeThis study was designed to compare the accuracy of targeting and the radiation dose of bone biopsies performed either under fluoroscopic guidance using a cone-beam CT with real-time 3D image fusion software (FP-CBCT-guidance) or under conventional computed tomography guidance (CT-guidance).MethodsSixty-eight consecutive patients with a bone lesion were prospectively included. The bone biopsies were scheduled under FP-CBCT-guidance or under CT-guidance according to operating room availability. Thirty-four patients underwent a bone biopsy under FP-CBCT and 34 under CT-guidance. We prospectively compared the two guidance modalities for their technical success, accuracy, puncture time, and pathological success rate. Patient and physician radiation doses also were compared.ResultsAll biopsies were technically successful, with both guidance modalities. Accuracy was significantly better using FP-CBCT-guidance (3 and 5 mm respectively: p = 0.003). There was no significant difference in puncture time (32 and 31 min respectively, p = 0.51) nor in pathological results (88 and 88 % of pathological success respectively, p = 1). Patient radiation doses were significantly lower with FP-CBCT (45 vs. 136 mSv, p < 0.0001). The percentage of operators who received a dose higher than 0.001 mSv (dosimeter detection dose threshold) was lower with FP-CBCT than CT-guidance (27 vs. 59 %, p = 0.01).ConclusionsFP-CBCT-guidance for bone biopsy is accurate and reduces patient and operator radiation doses compared with CT-guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hemorrhagic Complications of Percutaneous Cryoablation for Renal Tumors: Results from a 7-year Prospective Study

PurposeCryoablation of renal tumors is assumed to have a higher risk of hemorrhagic complications compared to other ablative modalities. Our purpose was to establish the exact risk and to identify hemorrhagic risk factors.Materials and MethodsThis IRB approved, 7-year prospective study included 261 renal cryoablations. Procedures were under conscious sedation and CT guidance. Pre- and postablation CT was obtained, and hemorrhagic complications were CTCAE tabulated. Age, gender, tumor size, histology, and probes number were tested based on averages or proportions using their exact permutation distribution. “High-risk” subgroups (those exceeding the thresholds of all variables) were tested for each variable alone, and for all combinations of variable threshold values. We compared the subgroup with the best PPV using one variable, with the subgroup with the best PPV using all variables (McNemmar test).ResultsThe hemorrhagic complication rate was 3.5 %. Four patients required transfusions, two required emergent angiograms, one required both a transfusion and angiogram, and two required bladder irrigation for outlet obstruction. Perirenal space hemorrhage was more clinically significant than elsewhere. Univariate risks were tumor size >2 cm, number of probes >2, and malignant histology (P = 0.005, 0.002, and 0.033, respectively). Multivariate analysis showed that patients >55 years with malignant tumors >2 cm requiring 2 or more probes yielded the highest PPV (7.5 %).ConclusionsAlthough older patients (>55 years old) with larger (>2 cm), malignant tumors have an increased risk of hemorrhagic complications, the low PPV does not support the routine use of embolization. Percutaneous cryoablation has a 3.5 % risk of significant hemorrhage, similar to that reported for other types of renal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolotherapy for Neuroendocrine Tumor Liver Metastases: Prognostic Factors for Hepatic Progression-Free Survival and Overall Survival

PurposeThe purpose of the study was to evaluate prognostic factors for survival outcomes following embolotherapy for neuroendocrine tumor (NET) liver metastases.Materials and MethodsThis was a multicenter retrospective study of 155 patients (60 years mean age, 57 % male) with NET liver metastases from pancreas (n = 71), gut (n = 68), lung (n = 8), or other/unknown (n = 8) primary sites treated with conventional transarterial chemoembolization (TACE, n = 50), transarterial radioembolization (TARE, n = 64), or transarterial embolization (TAE, n = 41) between 2004 and 2015. Patient-, tumor-, and treatment-related factors were evaluated for prognostic effect on hepatic progression-free survival (HPFS) and overall survival (OS) using unadjusted and propensity score-weighted univariate and multivariate Cox proportional hazards models.ResultsMedian HPFS and OS were 18.5 and 125.1 months for G1 (n = 75), 12.2 and 33.9 months for G2 (n = 60), and 4.9 and 9.3 months for G3 tumors (n = 20), respectively (p < 0.05). Tumor burden >50 % hepatic volume demonstrated 5.5- and 26.8-month shorter median HPFS and OS, respectively, versus burden ≤50 % (p < 0.05). There were no significant differences in HPFS or OS between gut or pancreas primaries. In multivariate HPFS analysis, there were no significant differences among embolotherapy modalities. In multivariate OS analysis, TARE had a higher hazard ratio than TACE (unadjusted Cox model: HR 2.1, p = 0.02; propensity score adjusted model: HR 1.8, p = 0.11), while TAE did not differ significantly from TACE.ConclusionHigher tumor grade and tumor burden prognosticated shorter HPFS and OS. TARE had a higher hazard ratio for OS than TACE. There were no significant differences in HPFS among embolotherapy modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Efficacy of Transarterial Radioembolization Combined with Chemoembolization for Bilobar Hepatocellular Carcinoma: A Single-Center Retrospective Study

BackgroundRadioembolization induced liver disease (REILD) is a possible sequela of transarterial radioembolization (TARE), particularly in cases of whole-liver treatment. To mitigate this problem, the safety and efficacy of combined transarterial chemoembolization (TACE) and TARE were evaluated for patients with bilobar hepatocellular carcinoma (HCC).Materials and MethodsNineteen patients (mean age 60 years; range 27–82 years) treated for HCC between June 2012 and September 2014 were included in the analysis. Each patient was treated with combined TARE and TACE for bilobar HCC, with or without portal vein thrombosis. The hepatic lobe with large HCC was treated with TARE, and the other lobe with small HCC(s) was treated with TACE. Laboratory and clinical data were investigated to determine REILD occurrence. Survival data were analyzed to compare the treatment efficacy of alternative treatment modalities, including TACE and sequential TARE.ResultsAll patients underwent TARE for a dominant tumor in one lobe and TACE for small nodule(s) in the other lobe of the liver. The mean yttrium-90 microspheres used in TARE were 2.8 GBq (range; 1.0-3.5 GBq), and the mean doses of doxorubicin and iodized oil were 24.5 mg and 5.2 mL, respectively, for TACE. No statistical differences were noted between laboratory data measured before and after treatment, and no procedure-related major clinical complications occurred. The median time-to-progression of patients was 10.0 months, and the median overall survival was 27.3 months.ConclusionCombined radioembolization and chemoembolization appears to be a safe and effective treatment modality for bilobar HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A General Framework for Monitoring Image Acquisition Workflow in the Radiology Environment: Timeliness for Acute Stroke CT Imaging

Many facets of an image acquisition workflow leave a digital footprint, making workflow analysis amenable to an informatics-based solution. This paper describes a detailed framework for analyzing workflow and uses acute stroke response timeliness in CT as a practical demonstration. We review methods for accessing the digital footprints resulting from common technologist/device interactions. This overview lays a foundation for obtaining data for workflow analysis. We demonstrate the method by analyzing CT imaging efficiency in the setting of acute stroke. We successfully used digital footprints of CT technologists to analyze their workflow. We presented an overview of other digital footprints including but not limited to contrast administration, patient positioning, billing, reformat creation, and scheduling. A framework for analyzing image acquisition workflow was presented. This framework is transferable to any modality, as the key steps of image acquisition, image reconstruction, image post processing, and image transfer to PACS are common to any imaging modality in diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring urban typologies using comprehensive analysis of transportation dynamics

Abstract As urban areas continue to expand and develop, categorizing cities into typologies offers a valuable framework for understanding metropolitan dynamics and fostering inter-city collaboration. However, existing typologies related to urban mobility have limitations, failing to consider cities within a single large urban region and often overlooking crucial dimensions such as trip demand and traffic flow. In this paper, we introduce a transportation-focused characterization for cities within a large urban region, specifically the San Francisco Bay Area, California. We incorporate over 40 metrics across five transportation dimensions: trip demand, road network, multi-modal network, traffic flow, and land use. Specifically, for the trip demand dimension, we include metrics capturing residents’ trip characteristics, such as mode share, intra-city trips, and inter-city trips. Additionally, we analyze the purpose of trips entering the city to gain a deeper understanding of incoming trip patterns. In the traffic flow dimension, we examine metrics like vehicle miles traveled, delay, and congestion to assess the traffic conditions on the street network. These, combined with other dimensions, provide a comprehensive view of a city’s transportation dynamics. Using unsupervised machine learning clustering methods, we identified eight distinct typologies for the Bay Area: Live Work Cities; Job and Activity Magnet Cities; Anchor Cities; Multi-modal Cities; Hyper-connected Cities; Low-density Residential Cities; Medium-density Residential Cities; and Mixed-use Residential Cities. Our findings show that many clusters are strongly influenced by trip demand and traffic flow metrics. Finally, we examine the practicality of this typology and its potential to guide collaborative transportation management strategies. The typologies provide a foundation for dialogue among Bay Area cities, focusing on evaluating shared characteristics and leveraging successes or challenges to develop unified strategies for transportation management.

Kuncheria, Anu↗

Microstructure and Mechanical Behavior of Heat-Treated and Thermomechanically Processed TA15 Ti Alloy Composites

For TA15 Ti alloy, which has been widely used to form key load-bearing components in aeronautic and space fields, particular performances and corresponding microstructures are demanded due to various service environments. By applying single-phase field heat treatment, single-phase + two-phase field heat treatments, forging (α + β phase zone) combined with high-temperature aging and dual heat treatment, four types of microstructures, namely the fully lamellar microstructure, basket weave microstructure, two-phase composite microstructure and tri-modal microstructure, were obtained, respectively. And after conducting mechanical property tests for these microstructures, it was found that enhancing the lamellar thickness in the fully lamellar microstructures, reducing the content of equiaxed α phase to about 20% or increasing the content of lamellar phase in the two-phase composite microstructures and controlling the content of equiaxed α phase within 20% in the tri-modal microstructure were beneficial for performance improving. In addition, two-phase and three-phase composite microstructures possessed excellent comprehensive mechanical properties, and fully lamellar microstructures had the highest fracture toughness.

36 MATERIALS SCIENCE↗

Advances in Multimodal Characterization of Structural Materials

The myriad detectors and instruments now available for materials characterization provide researchers with an ever-growing suite of tools to probe material behavior. Progress in the development of instrumentation and workflows that enable the collection, and leverage the potential, of various data modalities have provided novel insights into material behavior. Using data across multiple length scales, or performing complementary analyses of in situ and ex situ data, can help reveal a more complete picture of dynamic processes or material structure. However, the accurate combination, or fusion, of these disparate data modalities presents new challenges. Differences in resolution, as well as the varying length scales at which physical phenomena are exploited to generate these data, necessitate novel approaches to accurately interpret and combine these data. Furthermore, the papers within this special topic focus on the collection and fusion of multimodal data to better understand structural materials. From new frameworks and workflows for data segmentation and analysis, process monitoring, enhancing simulations, or interrogating mechanical response, these papers reveal the potential benefits of utilizing multimodal data.

36 MATERIALS SCIENCE↗