Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Automated piezoresponse force microscopy domain tracking during fast thermally stimulated phase transition in CuInP 2 S 6

Real-time tracking of dynamic nanoscale processes such as phase transitions by scanning probe microscopy is a challenging task, typically requiring extensive and laborious human supervision. Smart strategies to track specific regions of interest (ROI) in the system during such transformations in a fast and automated manner are necessary to study the evolution of the microscopic changes in such dynamic systems. In this work, we realize automated ROI tracking in piezoresponse force microscopy during a fast (≈0.8 °C s –1 ) thermally stimulated ferroelectric-to-paraelectric phase transition in CuInP 2 S 6 . We use a combination of fast (1 frame per second) sparse scanning with compressed sensing image reconstruction and real-time offset correction via phase cross correlation. The applied methodology enables in situ fast and automated functional nanoscale characterization of a certain ROI during external stimulation that generates sample drift and changes local functionality.

36 MATERIALS SCIENCE↗

A nanoscale gigahertz source realized with Josephson scanning tunneling microscopy

Using the AC Josephson effect in the superconductor-vacuum-superconductor tunnel junction of a scanning tunneling microscope (STM), we demonstrate the generation of GHz radiation. With the macroscopic STM tip acting as a λ/4-monopole antenna, we first show that the atomic scale Josephson junction in the STM is sensitive to its frequency-dependent environmental impedance in the GHz regime. Further, enhancing Cooper pair tunneling via excitations of the tip eigenmodes, we are able to generate high-frequency radiation. We find that for vanadium junctions, the enhanced photon emission can be tuned from about 25 GHz to 200 GHz and that large photon flux in excess of 10{sup 20 }cm{sup −2} s{sup −1} is reached in the tunnel junction. These findings demonstrate that the atomic scale Josephson junction in an STM can be employed as a full spectroscopic tool for GHz frequencies on the atomic scale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulating realistic imaging conditions for in situ liquid microscopy

In situ transmission electron microscopy enables the imaging of biological cells, macromolecular protein complexes, nanoparticles, and other systems in a near-native environment. In order to improve interpretation of image contrast features and also predict ideal imaging conditions ahead of time, new virtual electron microscopic techniques are needed. A technique for virtual fluid-stage high-angle annular dark-field scanning transmission electron microscopy with the multislice method is presented that enables the virtual imaging of model fluid-stage systems composed of millions of atoms. The virtual technique is exemplified by simulating images of PbS nanoparticles under different imaging conditions and the results agree with previous experimental findings. General insight is obtained on the influence of the effects of fluid path length, membrane thickness, nanoparticle position, defocus and other microscope parameters on attainable image quality.

Atomistic model↗

Thermal and structural stability of single- and multi-walled carbon nanotubes up to 1800 °C in Argon studied by Raman spectroscopy and transmission electron microscopy

Graphical abstract: Display Omitted Highlights: ► Structural stability of carbon nanotubes up to 1800 °C in Argon (∼0.05 MPa). ► Thorough TEM and Raman spectroscopy of as received and heat treated CNTs. ► Analyses on the extent of structural changes during high temperature exposure. ► Discussion on safe upper temperature limit for practical use of SWCNTs and MWCNTs. -- Abstract: Effect of high temperature exposure (up to 1800 °C) on morphology of single- and multi-walled carbon nanotubes in Argon atmosphere has been studied using Raman spectroscopy and transmission electron microscopy. Although, as received nanotubes contained irregular graphene layers and other structural defects, microscopic observations revealed that heat treatment in Argon reduced the defect density and helped proper alignment of graphene layers. Raman spectra of as received and heat treated nanotubes strongly reinforced the microscopic observations. While, D-band to G-band intensity ratio in Raman spectra of 1800 °C heat treated multiwalled nanotubes reduced by ∼43% over as received one, this ratio for heat treated singlewalled nanotubes was ∼27% lower than that of the untreated specimen. Present study suggested that although, multiwalled nanotubes were structurally stable up to 1800 °C in an inert atmosphere having only a few nano-scale defects, singlewalled nanotubes suffered considerable damage at 1800 °C due to much thinner dimension than the former.

36 MATERIALS SCIENCE↗

Helium Ion Microscopy

Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.

Belianinov, Alex↗

Practical spatial resolution of electron energy loss spectroscopy in aberration corrected scanning transmission elecron microscopy.

The resolution of electron energy loss spectroscopy (EELS) is limited by delocalization of inelastic electron scattering rather than probe size in an aberration corrected scanning transmission electron microscope (STEM). In this study, we present an experimental quantification of EELS spatial resolution using chemically modulated 2 x (LaMnO{sub 3})/2 x (SrTiO{sub 3}) and 2 x (SrVO{sub 3})/2 x (SrTiO{sub 3}) superlattices by measuring the full width at half maxima (FWHM) of integrated Ti M{sub 2,3}, Ti L{sub 2,3}, V L{sub 2,3}, Mn L{sub 2,3}, La N{sub 4,5}, La N{sub 2,3} La M{sub 4,5} and Sr L{sub 3} edges over the superlattices. The EELS signals recorded using large collection angles are peaked at atomic columns. The FWHM of the EELS profile, obtained by curve-fitting, reveals a systematic trend with the energy loss for the Ti, V, and Mn edges. However, the experimental FWHM of the Sr and La edges deviates significantly from the observed experimental tendency. Spatial resolution of aberration corrected STEM/EELS measured for Ti M{sub 2,3}, Ti L{sub 2,3}, V L{sub 2,3}, Mn L{sub 2,3}, La N{sub 4,5}, La N{sub 2,3} La M{sub 4,5} and Sr L{sub 3} edges using oxide superlattices. EELS signals recorded using large collection angles are peaked at atomic columns. The FWHM of the EELS profiles agrees with Egerton's empirical delocalization model for Ti, V, and Mn edges in thin samples. The FWHM of the Sr and La edges is larger than the model's prediction because of scattering by heavy atomic columns.

99 GENERAL AND MISCELLANEOUS↗

Time-Resolved X-Ray Microscopy for Materials Science

X-ray microscopy has been an indispensable tool to image nanoscale properties for materials research. One of its recent advances is extending microscopic studies to the time domain to visualize the dynamics of nanoscale phenomena. Large-scale X-ray facilities have been the powerhouse of time-resolved X-ray microscopy. Their upgrades, including a significant reduction of the X-ray emittance at storage rings (SRs) and fully coherent ultrashort X-ray pulses at free-electron lasers (FELs), will lead to new developments in instrumentation and will open new scientific opportunities for X-ray imaging of nanoscale dynamics with the simultaneous attainment of unprecedentedly high spatial and temporal resolutions. As a result, this review presents recent progress in and the outlook for time-resolved X-ray microscopy in the context of ultrafast nanoscale imaging and its applications to condensed matter physics and materials science.

36 MATERIALS SCIENCE↗

Epi-detected quadruple-modal nonlinear optical microscopy for label-free imaging of the tooth

We present an epi-detected quadruple-modal nonlinear optical microscopic imaging technique (i.e., coherent anti-Stokes Raman scattering (CARS), second-harmonic generation (SHG), third-harmonic generation (THG), and two-photon excited fluorescence (TPEF)) based on a picosecond (ps) laser-pumped optical parametric oscillator system for label-free imaging of the tooth. We demonstrate that high contrast ps-CARS images covering both the fingerprint (500–1800 cm{sup −1}) and high-wavenumber (2500–3800 cm{sup −1}) regions can be acquired to uncover the distributions of mineral and organic biomaterials in the tooth, while high quality TPEF, SHG, and THG images of the tooth can also be acquired under ps laser excitation without damaging the samples. The quadruple-modal nonlinear microscopic images (CARS/SHG/THG/TPEF) acquired provide better understanding of morphological structures and biochemical/biomolecular distributions in the dentin, enamel, and the dentin-enamel junction of the tooth without labeling, facilitating optical diagnosis and characterization of the tooth in dentistry.

60 APPLIED LIFE SCIENCES↗

Smart align -- A new tool for robust non-rigid registration of scanning microscope data

Many microscopic investigations of materials may benefit from the recording of multiple successive images. This can include techniques common to several types of microscopy such as frame averaging to improve signal-to-noise ratios (SNR) or time series to study dynamic processes or more specific applications. In the scanning transmission electron microscope, this might include focal series for optical sectioning or aberration measurement, beam damage studies or camera-length series to study the effects of strain; whilst in the scanning tunnelling microscope, this might include bias voltage series to probe local electronic structure. Whatever the application, such investigations must begin with the careful alignment of these data stacks, an operation that is not always trivial. In addition, the presence of low-frequency scanning distortions can introduce intra-image shifts to the data. Here, we describe an improved automated method of performing non-rigid registration customised for the challenges unique to scanned microscope data specifically addressing the issues of low-SNR data, images containing a large proportion of crystalline material and/or local features of interest such as dislocations or edges. Careful attention has been paid to artefact testing of the non-rigid registration method used, and the importance of this registration for the quantitative interpretation of feature intensities and positions is evaluated.

36 MATERIALS SCIENCE↗

Scanning tunneling microscopy for ultracold atoms

We propose a versatile experimental probe for cold atomic gases analogous to the scanning tunneling microscope (STM) in condensed matter. This probe uses the coherent coupling of a single particle to the system. Depending on the measurement sequence, our probe allows us to obtain either the local density and spatial density correlations, with a resolution on the nanometer scale, or the single particle correlation function in real time. We discuss applications of this scheme to the various possible phases for a two dimensional Hubbard system of fermions in an optical lattice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the local conductivity of Cu films using temperature-assisted agglomerated Cu nanostructures

We investigate the structural and electrical properties of Cu film and reveal their changes as a function of post-annealing temperature. Thermal annealing of a Cu film on a dielectric substrate can improve its crystallinity; however, high-temperature annealing also leads to a morphological transformation that hinders the precise measurement of electrical properties. The enhanced crystallinity of the Cu films is verified with x-ray diffraction as the annealing temperature increases. To examine the electrical properties of the Cu film after the dewetting processes, which promotes the formation of voids and agglomerations, we utilize both conventional micro four-point probe method as well as an advanced four-point probe scanning tunneling microscopy (4P-STM) technique to measure the conductance and evolution of the microscopic structural properties. We could eliminate a deceptive effect of voids with 4P-STM technique, and disclosed a significantly reduced resistivity (1.88 ± 0.07 µΩ∙cm) of Cu nanostructure after post-annealing at 700 °C. We unveiled impact of crystallinity and imperfections of Cu nanostructure, and discussed the critical role of the twin grain boundaries of single-crystalline Cu (1 1 1) on an Al 2 O 3 substrate. We anticipate that understanding the evolution of the structures and the enhanced electrical properties of the post-annealed Cu nanostructures would be important for nanoscale devices where Cu is used as an interconnecting material and could provide a new route to control the plasmonic applications.

36 MATERIALS SCIENCE↗

CHAMP (Camera, Handlens, and Microscope Probe)

CHAMP (Camera, Handlens And Microscope Probe)is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As a robotic arm-mounted imager, CHAMP supports stereo imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision rangefinding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. CHAMP was originally developed through the Mars Instrument Development Program (MIDP) in support of robotic field investigations, but may also find application in new areas such as robotic in-orbit servicing and maintenance operations associated with spacecraft and human operations. We overview CHAMP'S instrument performance and basic design considerations below.

robotic field investigations↗

High-Resolution Mosaic Imaging with Multifocal, Multiphoton Photon-Counting Microscopy

High-resolution mosaic imaging is performed for the first time to our knowledge with a multifocal, multiphoton, photon-counting imaging system. We present a novel design consisting of a home-built femtosecond Yb-doped KGdWO{sub 4} laser with an optical multiplexer, which is coupled with a commercial Olympus IX-71 microscope frame. Photon counting is performed using single-element detectors and an inexpensive electronic demultiplexer and counters.

47 OTHER INSTRUMENTATION↗

In situ transmission electron microscopy study on the crystallization of GeTe binary alloy

Microstructural properties of GeTe thin films were investigated by an in situ heating method within a high voltage electron microscope (HVEM). The results confirm that the transformation from an amorphous state to a fcc crystalline state yields a GeTe binary alloy with a ring-shaped amorphous structure. The fcc structured GeTe transforms into a GeTe orthorhombic structure during the experiment. The crystallization behavior of the GeTe orthorhombic structure in the HVEM is quite different from thermal crystallization. Our observation of real-time structural change confirms that the relaxed amorphous structure participates in the crystallization process in the electron beam irradiation condition.

36 MATERIALS SCIENCE↗

Reactive sputter deposition of alumina films on magnesium alloy by double cathode glow-discharge plasma technique

In order to overcome the problem of the corrosion resistance of AZ31 magnesium alloy, the nanocrystalline Al{sub 2}O{sub 3} film was deposited on AZ31 magnesium alloy by double cathode glow-discharge plasma technique. The microstructure, chemical composition and elemental chemical state of the sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film were analyzed by means of scanning electron microscopy equipped with an energy dispersive spectroscope, X-ray diffraction), transmission electron microscope and X-ray photoelectron spectroscopy. The results indicated that the sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film consisted of single {theta}-Al{sub 2}O{sub 3} phase with average grain size about 60 nm. The hardness and the elastic modulus of the as-deposited nanocrystalline Al{sub 2}O{sub 3} film were about 17.21 GPa and 217 GPa measured by nanoindentation instrument, respectively. The corrosion behavior of the sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film in 3.5%NaCl solution was investigated by potentiodynamic polarization and electrochemical impedance spectroscopy. The amount of porosity for the sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film calculated by two electrochemical methods was equal to 0.0086% and 0.168%, respectively. The sputter-deposited nanocrystalline Al{sub 2}O{sub 3} film exhibited excellent corrosion resistance, which was attributed to its dense enough structure to prevent magnesium alloy from corrosion in aggressive solutions.

36 MATERIALS SCIENCE↗

Aberration corrected scanning transmission electron microscopy and electron energy loss spectroscopy studies of epitaxial Fe/MgO/(001)Ge heterostructures

Aberration correction in the scanning transmission electron microscope combined with electron energy loss spectroscopy allows simultaneous mapping of the structure, the chemistry and even the electronic properties of materials in one single experiment with spatial resolutions of the order of one Angstrom. Here the authors will apply these techniques to the characterization of epitaxial Fe/MgO/(001)Ge and interfaces with possible applications for tunneling junctions, and the authors will show that epitaxial MgO films can be grown on a (001)Ge substrates by molecular beam epitaxy and how it is possible to map the chemistry of interfaces with atomic resolution. Epitaxial growth of insulator oxides on semiconductors constitutes a key issue within the field of electronics, and a considerably large effort has been devoted to harness the growth of high-k oxides on Si. Ge, due to its high electronic and hole mobility, is a very interesting alternative as a potential substrate for future high performance complementary metal-oxide-semiconductor field-effect transistors. However, a major issue is to avoid the high resistivity at the source and drain contacts ensuing from the pinning of the Fermi level at the valence-band maximum. It has been suggested that this problem could be fixed by depositing a thin insulating tunneling barrier between the Ge substrate and the metal contacts. In this case, single crystal epitaxy would represent an additional benefit, since it would lead to a reduction of interfacial defects and improved performance of the tunneling barrier. MgO has been suggested to fulfill such requisites. Furthermore, MgO has been demonstrated to be a good substrate for epitaxial growth of transition metals thin films, such as Fe and Co, thus avoiding the potential problem of chemical reactivity with Ge. In such a scenario, epitaxial deposition of high quality MgO films on Ge substrates is highly desirable. But in addition, successful epitaxial growth of MgO on a semiconductor would also constitute a plus for applications in spintronics, since the injection of a spin polarized current from a ferromagnetic electrode to a non-magnetic semiconductor requires the presence of a potential barrier. MgO represents a convenient choice because the symmetry filtering properties at the interface with transition metals would allow an efficient spin filtering effect. For this approach to succeed, a suitable semiconducting substrate where MgO can be grown epitaxially must be found. And again, while GaAs and Si have been investigated for such role, Ge has not received much attention so far. In this study the authors report on the atomic resolution characterization of high quality interfaces in Fe/MgO/(001)Ge heterostructures. The study of the defects, the inhomogeneities and the interface structure of such junctions is a must to pave the way toward future applications. For this aim, the combination of scanning transmission electron microscopy (STEM) and electron energy loss spectroscopy (EELS) is a most useful tool, since it allows these features to be probed with atomic resolution. Spherical aberration correction in the STEM allows for increased contrast, allowing even single atoms to be detected both in imaging and spectroscopy.

36 MATERIALS SCIENCE↗

Identification of modes of fracture in a 2618-T6 aluminum alloy using stereophotogrammetry

The identification and the development of a quantification technique of the modes of fracture in fatigue fracture surfaces of a 2618-T6 aluminum alloy were developed during this research. Fatigue tests at room and high temperature (230 Degree-Sign C) were carried out to be able to compare the microscopic fractographic features developed by this material under these testing conditions. The overall observations by scanning electron microscopy (SEM) of the fracture surfaces showed a mixture of transgranular and ductile intergranular fracture. The ductile intergranular fracture contribution appears to be more significant at room temperature than at 230 Degree-Sign C. A quantitative methodology was developed to identify and to measure the contribution of these microscopic fractographic features. The technique consisted of a combination of stereophotogrammetry and image analysis. Stereo-pairs were randomly taken along the crack paths and were then analyzed using the profile module of MeX software. The analysis involved the 3-D surface reconstruction, the trace of primary profile lines in both vertical and horizontal directions within the stereo-pair area, the measurements of the contribution of the modes of fracture in each profile, and finally, the calculation of the average contribution in each stereo-pair. The technique results confirmed a higher contribution of ductile intergranular fracture at room temperature than at 230 Degree-Sign C. Moreover, there was no indication of a direct relationship between this contribution and the strain amplitudes range applied during the fatigue testing. - Highlights: Black-Right-Pointing-Pointer Stereophotogrammetry and image analysis as a measuring tool of modes of fracture in fatigue fracture surfaces. Black-Right-Pointing-Pointer A mixture of ductile intergranular and transgranular fracture was identified at room temperature and 230 Degree-Sign C testing. Black-Right-Pointing-Pointer Development of a quantitative methodology to obtain the percentage of modes of fracture within the fracture surface.

36 MATERIALS SCIENCE↗

CHAMP - Camera, Handlens, and Microscope Probe

CHAMP (Camera, Handlens And Microscope Probe) is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As an arm-mounted imager, CHAMP supports stereo-imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision range-finding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. Currently designed with a filter wheel with 4 different filters, so that color and black and white images can be obtained over the entire Field-of-View, future designs will increase the number of filter positions to include 8 different filters. Finally, CHAMP incorporates controlled white and UV illumination so that images can be obtained regardless of sun position, and any potential fluorescent species can be identified so the most astrobiologically interesting samples can be identified.

Mungas, G. S.↗