Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Missing data in multi-omics integration: Recent advances through artificial intelligence

Biological systems function through complex interactions between various ‘omics (biomolecules), and a more complete understanding of these systems is only possible through an integrated, multi-omic perspective. This has presented the need for the development of integration approaches that are able to capture the complex, often non-linear, interactions that define these biological systems and are adapted to the challenges of combining the heterogenous data across ‘omic views. A principal challenge to multi-omic integration is missing data because all biomolecules are not measured in all samples. Due to either cost, instrument sensitivity, or other experimental factors, data for a biological sample may be missing for one or more ‘omic techologies. Recent methodological developments in artificial intelligence and statistical learning have greatly facilitated the analyses of multi-omics data, however many of these techniques assume access to completely observed data. A subset of these methods incorporate mechanisms for handling partially observed samples, and these methods are the focus of this review. We describe recently developed approaches, noting their primary use cases and highlighting each method's approach to handling missing data. We additionally provide an overview of the more traditional missing data workflows and their limitations; and we discuss potential avenues for further developments as well as how the missing data issue and its current solutions may generalize beyond the multi-omics context.

97 MATHEMATICS AND COMPUTING↗

Analysis of Near-Field Magnetic Responses on ZrTe 5 through Cryogenic Magneto-THz Nano-Imaging

One manifestation of light-Weyl fermion interaction is the emergence of chiral magnetic effects under magnetic fields. Probing real space magnetic responses at terahertz (THz) scales is challenging but highly desired, as the local responses are less affected by the topologically trivial inhomogeneity that is ubiquitous in spatially averaged measurements. Here, we implement a cryogenic THz microscopy instrument under a magnetic field environment—a task only recently achieved. We explore the technical approach of this system and characterize the magnetic field’s influence on our AFM operation by statistical noise analysis. We find evidence for local near-field spatial variations in the topological semimetal ZrTe 5 up to a 5-Tesla magnetic field and obtain near-field THz spectra to discuss their implications for future studies on the chiral magnetic effect.

36 MATERIALS SCIENCE↗

Deep Spectroscopy with DESI for Photometric Redshift Training and Calibration

Deep spectroscopic samples can improve photometric redshift (photo-z) estimates and reduce uncertainties on redshift distributions. Such improvements can increase the cosmological constraining power of large imaging-based experiments such as the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) and mitigate what may be a limiting systematic effect. We present results from the “DESI-Deep pilot” program, which was designed to assess the capability of the Dark Energy Spectroscopic Instrument (DESI) on the 4m Mayall telescope to measure redshifts of galaxies as faint as expected lensing samples for early LSST data (m i ≤ 24.5). We find that DESI is remarkably efficient at this task, with redshift success rates comparable to the results of observations from 10 m class telescopes with only ∼2 × longer integration time (rather than ∼8 × longer as would be expected from aperture-area scaling), while simultaneously achieving ∼30 times larger multiplexing. We also find that the signal-to-noise ratio of the spectra scales as expected for background-limited observations even for the longest exposure times (∼7 hr) and faintest targets in the program. These results demonstrate that DESI could provide the definitive redshift sample for the early years of LSST with a modest investment of observing time. Based upon the results of this program, we provide updated predictions for the time required to collect benchmark samples for photo-z training and calibration using a variety of spectroscopic facilities. Finally, we describe a potential “DESI-Deep” survey designed to train and calibrate photo-z’s for imaging experiments, and provide forecasts of its impact on cosmological inference.

Dey, Biprateep [University of Toronto; University ↗

AMICE2 measurements of lab-generated and ambient aerosols at BNL from 2025-07-21 to 2025-08-22

From July 21 through August 22, 2025 the Absorption Measurement Inter-Comparison Experiment phase 2 (AMICE2) was conducted at Brookhaven National Laboratory. The experiment included concurrent operation of several filter-based instruments and in situ instruments sampling from a common sample line. The common sample line provided all instruments with either lab-generated aerosols composed of external mixtures of nigrosin, cabojet, and ammonium sulfate, or with ambient aerosol drawn through an external stack. This data set contains measurements from the CAPS PMssa instrument taken as a reference instrument at 532 nm and against which the effectiveness of the filter corrections may be assessed. It also contains attenuation coefficients from all filter-based instruments and filter transmittances in order to permit correction for filter loading, and the SSA and COA to permit corrections for aerosol darkness. Finally, two sets of multiplicative corrections are provided for the AE-33, TAP, and MA-350 instruments: the first one, Corr1, corrects for filter amplification factor and loading, the second one, Corr2, corrects for the aerosol darkness in terms of the natural log of COA.

Aerosol Extinction↗

Effects of Coatings on Water Intrusion and Strain Gauge Durability in Submerged Fatigue Conditions: Preprint

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand the combined effects of moisture intrusion and mechanical fatigue on marine energy structures, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Measuring strain is critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions was not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure, strains, and strain gauge failure modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite fatigue testing↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 3 - Raw Data

Sequence 3: Tower Wake Measure (P) Sequence 3 used a downwind, rigid turbine with a 3.4° cone angle. The wind speeds for this sequence corresponded to subcritical [7 m/s], transitional [15 m/s], and supercritical [20 m/s] Reynolds number regimes for the circular cross-section tower. The yaw angle and blade tip pitch angles were selected to traverse the probe tip across the tower wake, while keeping the probe axis approximately parallel to the tunnel centerline. The rotor was parked with the instrumented blade at 180° azimuth. Blade and probe pressure measurements were collected.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 6 - Raw Data

Sequence 6: Shroud Wake Measure (P) This test sequence used a downwind, rigid turbine with a 3.4° cone angle. The wind speeds for this sequence corresponded to subcritical [7 m/s], transitional [15 m/s], and supercritical [20 m/s] Reynolds number regimes for the circular cross-section tower. The yaw angle and blade tip pitch angles were selected to traverse the probe tip across the tower wake while keeping the probe axis approximately parallel to the tunnel centerline. The rotor was parked with the instrumented blade at 180° azimuth. Blade and probe pressure measurements were collected. An airfoil-shaped aluminum shroud was placed on the tower below the 34% span five-hole probe. It extended below the 91% span five-hole probe. The turntable angle was adjusted to position the shroud at various angles relative to the flow.

17 WIND ENERGY↗

CHESS 2025: Leaf Area Index (LAI) for meadow, shrub, tree, and understory vegetation

This dataset contains Leaf Area Index (LAI) measurements made as part of the Colorado Headwaters Ecological Spectroscopy Study (CHESS) during June and July of 2025. Data were collected in the Upper Gunnison Basin, Colorado, across three study domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). Field observations of LAI were collected within 72 hours of airborne data collection by the National Ecological Observatory Network’s Aerial Observation Platform (NEON AOP). The NEON AOP collected waveform LiDAR (Light Detection and Ranging) and imaging spectrometer data in 426 spectral bands from the visible to shortwave infrared. LAI measurements were collected using the LICOR LAI-2200C Plant Canopy Analyzer following protocols outlined in the instrument manual (LI-COR 2019). Sampling targeted four distinct vegetation types: meadows, shrubs, trees, and aspen forest understory. We have archived data separately by site type because different field methods were used for each. At meadow sites, measurements were made at the four corners of 1m x 1m plots, with the instrument moving inward toward the center of the plot. At shrub sites, we measured the canopies of individual shrubs. At tree sites, we made measurements within a 10m x 10m subplot centered around a focal tree, with 30 observations taken on a regular grid. At aspen understory sites, we measured overstory trees following the tree protocol and understory herbaceous vegetation following the meadow protocol. All measurements included above-canopy (A) and below-canopy (B) readings, with specific protocols for scattering correction measurements in direct-sun conditions. Data were processed using the R package `rlai` (Worsham 2025). This package includes functions to calculate LAI, gap fraction, apparent clumping factor (Ω), scattering correction, and other canopy metrics. Package contents: Full file descriptions appear in ‘flmd.csv’. Files named according to the convention ‘lai_*_summary_data_cleaned.csv’ contain summary values of LAI, apparent clumping factor (Ωapp), and scattering correction factors for each site. These are the analysis-ready products that most data users will work with. Files named ‘lai_*_metadata_cleaned.csv’ contain additional site-level observations made during field collection. We have also archived intermediate and supplementary data for users who wish to check our processing approach or apply alternative methods. ‘raw_lai_2200C.zip’ contains the raw files as read from the LI-COR instrument, with no processing applied, in TXT format. The zip archive contains subdirectories by site type, which are further subdivided by sampling area. Filenames correspond to the sampling site number. ‘intermediate_results.zip’ contains detailed output from the processing routines, in JSON format. The zip archive contains subdirectories by site type; filenames correspond to the sampling site number. ‘scattering_correction_logs.zip’ contains logfiles from the implementation of Kobayashi et al.'s (2013) scattering correction algorithm. The logfiles report values of several parameters at each iteration of the algorithm, as the model converges toward a stable solution. They are intended for users who want to verify scattering correction performance. The zip archive contains subdirectories by site type; filenames correspond to the sampling site number. ‘spot_checks.csv’ reports LAI and other values for a small number of files processed with LI-COR FV2200 software (LI-COR 2013) using the same control parameters as in our R-based approach. Additional metadata are provided in a data dictionary describing column names and definitions (dd.csv), and in a file-level metadata file (flmd.csv). All zip files can be expanded with common archive utilities. TXT, CSV, and JSON files can be ingested into R or Python computing environments or read in common text editor utilities. Geospatial information: Geospatial data for mapping measurement site locations are in the files CHESS_polygons_lai_UTM.geojson, CHESS_polygons_shrub_UTM.geojson, and CHESS_polygons_meadow_UTM.geojson in the companion geospatial package for the 2025 CHESS campaign, ‘CHESS 2025: Location data for field observations and sampling’ (Henderson et al., 2026). CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. * Todorov and Worsham are co–first authors.

2018 NEON and 2025 CHESS Campaigns↗

Single-Crystal Diffuse Neutron Scattering Study of the Dipole-Octupole Quantum Spin-Ice Candidate Ce 2⁢ Zr 2 ⁢O 7 : No Apparent Octupolar Correlations Above 𝑇 = 0.05 K

The insulating magnetic pyrochlore Ce 2 ⁢Zr 2 ⁢O 7 has gained attention as a quantum spin-ice candidate with dipole-octupole character that arises from the crystal-electric-field ground-state doublet for the Ce 3+ Kramers ion. This dipole-octupole character permits both spin-ice phases based on magnetic dipoles and those based on more-exotic octupoles. This work reports low-temperature neutron diffraction measurements on single-crystal Ce 2 ⁢Zr 2⁢ O 7 with 𝑄 coverage both at low 𝑄, where the magnetic form factor for dipoles is near maximal, and at high 𝑄, covering the region where the magnetic form factor for Ce 3+ octupoles is near maximal. This study was motivated by recent powder neutron diffraction studies of other Ce-based dipole-octupole pyrochlores, Ce 2 ⁢Sn 2 ⁢O 7 and Ce 2 ⁢Hf 2 ⁢O 7 , which each showed temperature-dependent diffuse diffraction at high 𝑄, interpreted as arising from octupolar correlations. Our measurements use an optimized single-crystal diffuse scattering instrument that allows us to screen against strong Bragg scattering from Ce 2 ⁢Zr 2 ⁢O 7 . The temperature-difference neutron diffraction reveals a low-𝑄 peak consistent with dipolar spin-ice correlations reported in previous work, and an alternation between positive and negative net intensity at higher 𝑄. These features are consistent with our numerical-linked-cluster calculations using pseudospin interaction parameters previously reported for Ce 2 ⁢Zr 2⁢ O 7 , Ce 2 ⁢Sn 2 ⁢O 7 , and Ce 2 ⁢Hf 2 ⁢O 7 . Importantly, neither the measured data nor any of the NLC calculations show evidence for increased scattering at high 𝑄 resulting from octupolar correlations. We conclude that at the lowest attainable temperature for our measurements (𝑇 = 0.05 K), scattering from octupolar correlations in Ce 2 ⁢Zr 2 ⁢O 7 is not present in the neutron diffraction signal on the level of our observation threshold of around 0.1% of the low-𝑄 dipole scattering. We compare these results to those obtained earlier on powder Ce 2 ⁢Sn 2 ⁢O 7 and Ce 2⁢ Hf 2⁢ O 7 , and to low-energy inelastic neutron scattering from single-crystal Ce 2 ⁢Zr 2 ⁢O 7 .

36 MATERIALS SCIENCE↗

Spitzer IRAC Photometry of JWST Calibration Stars

We present infrared photometry of all 36 potential JWST calibrators for which there is archival Spitzer IRAC data. This photometry can then be used to inform the stellar models necessary to provide absolute calibration for all JWST instruments. We describe in detail the steps necessary to measure IRAC photometry from archive retrieval to photometric corrections. To validate our photometry, we examine the distribution of uncertainties from all detections in all four IRAC channels as well as compare the photometry and its uncertainties to those from models, ALLWISE, and the literature. Seventy-five percent of our detections have standard deviations per star of all observations within each channel of less than 3%. The median standard deviations are 1.2%, 1.3%, 1.1%, and 1.9% in [3.6]–[8.0], respectively. We find less than 8% standard deviations in differences of our photometry with ALLWISE and excellent agreement with literature values (less than 3% difference), lending credence to our measured fluxes. JWST is poised to do groundbreaking science, and accurate calibration and cross-calibration with other missions will be part of the underpinnings of that science.

47 OTHER INSTRUMENTATION↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

Improvement of Quantification in Non-Destructive Characterization of Radioactive Waste Packages -Introduction to the Ideas of a Currently Started Project - 20197

For the characterization of radioactive waste packages (e.g. 200-L drums) with inhomogeneous activity and density distributions preferably non-destructive methods like segmented gamma scanning and transmission measurements are applied. While the first is used for identification of the radioactive inventory, both are necessary for a reliable activity quantification. Although at nuclear facilities, segmented gamma scanner are state-of-the-art and are mostly equipped with a vertically moveable transmission source the combining of this data and further a-priori information improving accuracy in data estimation giving realistic, reliable and traceable uncertainty estimations are improvable. This challenge is tackled by a R and D project funded by the German Federal Ministry of Education and Research (BMBF). The boundary conditions for this project are (i) taking into account the typical instrumentation available at nuclear facilities, (ii) minimize the overall measurement time and (iii) combining data from emission and transmission measurements by Bayesian methods. For the R and D project, being still in its initial stage, the basic ideas, the data used for evaluation and the result of a preliminary investigation demonstrating the proof of principle are presented. Additionally, some first aspects on spatial resolution in emission and transmission measurements are addressed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Speed of Sound Measurements of Binary Mixtures of Difluoromethane (R-32) with 2,3,3,3-Tetrafluoropropene (R-1234yf) or trans-1,3,3,3-Tetrafluoropropene (R-1234ze(E)) Refrigerants

In this article, sound speed data measured using a dual-path pulse-echo instrument are reported for binary mixtures of difluoromethane (R-32) with 2,3,3,3-tetrafluoropropene (R-1234yf) or trans-1,3,3,3-tetrafluoropropene (R-1234ze(E)). The sound speed is reported at two compositions for each binary mixture of approximately (0.33/67) and (0.67/0.33) mole fraction at temperatures between 230 K and 345 K. Data are reported from pressures slightly above the bubble point to 12 MPa for R-32/1234yf mixtures to avoid potential polymerization reactions and to 53 MPa for the R-32/1234ze(E) mixtures. The mean uncertainty of the sound speed data are less than 0.1% of the measured value where uncertainties at individual state points range from 0.04% to 0.5% of the measured value as the conditions approach the mixture critical region. The reported data are compared to available Helmholtz-energy-explicit EOS included in REFPROP and all systems studied have average absolute deviations greater than 2%. The comparisons show that further adjustments to the mixture models are needed to provide a reasonable representation of the data within its experimental uncertainty.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Clustering of high-redshift quasars with DESI DR2

We present clustering measurements for high-redshift quasars using data from the Dark Energy Spectroscopic Instrument Data Release 2. Our sample consists of quasars with $2.0 < z < 3.5$ in the luminosity range $M_{1450} \leq -19.94$ mag. We measure the mean quasar bias $b_Q(\bar{z} = 2.48) = 3.61 \pm 0.01$ for the full sample of $\sim 715,000$ quasars and quantify the redshift evolution of quasar bias by dividing the sample into four equal redshift bins. There is strong evolution of the quasar bias with redshift that is well fit by the function $b_Q(z) = a [(1 + z)^2 - 6.565] + b$ with $a=0.230 \pm 0.007$ and $b=2.394 \pm 0.035$, and this fit is also a good match to lower redshift measurements in the literature. This bias evolution is consistent with a characteristic halo mass of $\bar{M}_{\mathrm{h}} \sim 10^{12}\,\mathrm{M_\odot}$ that does not vary significantly with redshift. The inferred duty cycles for quasars in our sample are $f_{\mathrm{duty}} \sim 10^{-2}$, staying mostly constant over redshifts. We investigate the luminosity dependence of quasar clustering by dividing each of our four redshift bins into three luminosity bins. The size of our quasar sample permits the first statistically significant measurement of the luminosity dependence of quasar bias at these redshifts. We measure weak dependence of quasar bias on luminosity at fixed redshift, inconsistent with no dependence, but weaker than predicted by a model in which quasar luminosity is tightly correlated with halo mass. These clustering measurements provide a stringent test for models of active black hole light curves and the black hole-halo connection at high redshift.

Charles, M. [Ohio State U.; Chicago U., KICP] (ORC↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗