A novel system for measurement of the transverse electron momentum distribution from photocathodes

The transverse momentum of electrons produced by a photocathode contributes significantly to the performance of several different types of accelerator-based light sources, such as Free Electron Lasers, as well as systems designed for ultrafast electron diffraction and dynamic transmission electron microscopy. Minimization of the transverse emittance from photocathodes is the subject of intensive research, and therefore measurement of this parameter is of great importance. Here, we describe a simple system that offers real time measurements of transverse emittance and can be easily integrated into the photocathode fabrication process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near infrared laser annealing of CdTe and in-situ measurement of the evolution of structural and optical properties

The high performance of polycrystalline CdTe thin film solar cells is enabled by annealing in the presence of Cl. This process is typically carried out for tens of minutes resulting in reduction of defect states within the bandgap among other beneficial effects. In this work, we investigate laser annealing as a means of rapidly annealing CdTe using a continuous wave sub-bandgap 1064 nm laser. The partial transmission of the beam allows us to monitor the annealing process in-situ and in real time. We find that optoelectronic and structural changes occur through two distinct kinetic processes resulting in the removal of deep defects and twinned regions, respectively. A multilayer optical model including surface roughness is used to interpret both the in-situ transmission as well as ex-situ reflectivity measurements. These experiments demonstrate beneficial material changes resulting from sub-bandgap laser-driven CdCl{sub 2} treatment of CdTe in minutes, which is an important step towards accelerating the processing of the CdTe absorber layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron and hole drift mobility measurements on methylammonium lead iodide perovskite solar cells

We report nanosecond domain time-of-flight measurements of electron and hole photocarriers in methylammonium lead iodide perovskite solar cells. The mobilities ranged from 0.06 to 1.4 cm{sup 2}/Vs at room temperature, but there is little systematic difference between the two carriers. We also find that the drift mobilities are dispersive (time-dependent). The dispersion parameters are in the range of 0.4–0.7, and they imply that terahertz domain mobilities will be much larger than nanosecond domain mobilities. The temperature-dependences of the dispersion parameters are consistent with confinement of electron and hole transport to fractal-like spatial networks within nanoseconds of their photogeneration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-color spatial and temporal temperature measurements using a streaked soft x-ray imager

A dual-channel streaked soft x-ray imager has been designed and used on high energy-density physics experiments at the National Ignition Facility. This streaked imager creates two images of the same x-ray source using two slit apertures and a single shallow angle reflection from a nickel mirror. Thin filters are used to create narrow band pass images at 510 eV and 360 eV. When measuring a Planckian spectrum, the brightness ratio of the two images can be translated into a color-temperature, provided that the spectral sensitivity of the two images is well known. To reduce uncertainty and remove spectral features in the streak camera photocathode from this photon energy range, a thin 100 nm CsI on 50 nm Al streak camera photocathode was implemented. Provided that the spectral shape is well-known, then uncertainties on the spectral sensitivity limits the accuracy of the temperature measurement to approximately 4.5% at 100 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements

Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D{sub 2} molecules and the He ash which will be produced by deuterium-tritium fusion. To study He exhaust, an in situ Penning gauge system is being developed at UW-Madison that is optimized for good pressure and high spectroscopic sensitivity. Three different anode geometries have been studied regarding their vacuum electrostatic fields, light output, and ion current. The light output of the two new anode configurations are at least one order of magnitude above the currently available designs, hence improving the spectroscopic sensitivity at similar total neutral pressure resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the WFIP2 updates to the HRRR model using scanning Doppler lidar measurements in the complex terrain of the Columbia River Basin

The wind-energy (WE) industry relies on numerical weather prediction (NWP) forecast models as foundational or base models for many purposes, including wind-resource assessment and wind-power forecasting. During the Second Wind Forecast Improvement Project (WFIP2) in the Columbia River Basin of Oregon and Washington, a significant effort was made to improve NWP forecasts through focused model development, to include experimental refinements to the High Resolution Rapid Refresh (HRRR) model physics and horizontal grid spacing. In this study, the performance of an experimental version of HRRR that includes these refinements is tested against a control version, which corresponds to that of the operational HRRR run by National Oceanic and Atmospheric Administration/National Centers for Environmental Protection at the outset of WFIP2. Furthermore, the effects of horizontal grid resolution were also tested by comparing wind forecasts from the HRRR (with 3-km grid spacing) with those from a finer-resolution HRRR nest with 750-m grid spacing. Model forecasts are validated against accurate wind-profile measurements by three scanning, pulsed Doppler lidars at sites separated by a total distance of 71 km. Model skill and improvements in model skill, attributable to physics refinements and improved horizontal grid resolution, varied by season, by site, and during periods of atmospheric phenomena relevant to WE. In general, model errors were the largest below 150 m above ground level (AGL). Experimental HRRR refinements tended to reduce the mean absolute error (MAE) and other error metrics for many conditions, but degradation in skill (increased MAE) was noted below 150 m AGL at the two lowest-elevation sites at night. Finer resolution was found to produce the most significant reductions in the error metrics.

17 WIND ENERGY↗

Land-based wind plant wake characterization using dual-Doppler radar measurements at AWAKEN

Wind plant wakes have been shown to persist for tens of kilometers downstream in offshore environments, reducing the power output of neighboring plants, but their behavior on land remains relatively unexplored through observation. This study capitalizes on the unique and extensive field data collected for the American WAKE ExperimeNt (AWAKEN) project underway in northern Oklahoma. X-band dual-Doppler radars deployed at this site measure wind speed and direction at 25-m and 2-min resolution within a 30-km range, capturing the interactions between three neighboring wind plants. These measurements show that the wake of one wind plant extends at least 15 km downstream under easterly wind and stable atmospheric conditions. Though the wake wind speed increases within the first 10 km, it plateaus at 90% of the freestream wind speed. The spanwise velocity distribution within the wake initially shows the clear signature of the wind plant layout, which is smoothed as it propagates downstream, indicating spanwise momentum transfer is a key mechanism in wind plant wake development and recovery. These findings have important implications for wind plant siting decisions and resource assessments, and provide insights into atmospheric interactions at the wind plant scale.

17 WIND ENERGY↗

Effectively classically correlated state of a measured system and a bosonic measurement apparatus

We consider a multilevel system coupled to a bosonic measurement apparatus. We derive exact expressions for the time-dependent expectation values of a large class of physically relevant observables that depend on degrees of freedom of both systems. We find that, for this class, though the two systems become entangled as a result of their interaction, they appear classically correlated for long enough times. The unique corresponding time-dependent separable state is determined explicitly. To better understand the physical parameters that control the time scale of this effective disentanglement process, we study a one-dimensional measurement apparatus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Centrality dependence of proton and antiproton spectra in Pb+Pb collisions at 40A GeV and 158A GeV measured at the CERN Super Proton Synchrotron

The yields of (anti)protons were measured by the NA49 Collaboration in centrality-selected Pb + Pb collisions at 40A and 158A GeV. Particle identification was obtained in the laboratory momentum range from 5 to 63 GeV/c by measuring the energy loss dE/dx in the time projection chamber detector gas. The corresponding rapidity coverage extends 1.6 units from midrapidity into the forward hemisphere. Transverse-mass spectra, the rapidity dependences of the average transverse mass, and rapidity density distributions were studied as a function of collision centrality. The values of the average transverse mass as well as the midrapidity yields of protons normalized to the number of wounded nucleons show only modest centrality dependences. In contrast, the shape of the rapidity distribution changes significantly with collision centrality, especially at 40A GeV. The experimental results are compared to calculations of the hadron-string dynamics and the ultrarelativistic quantum-molecular-dynamics transport models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the {sup 157}Gd(n,{gamma}) reaction with the DANCE {gamma} calorimeter array

The {sup 157}Gd(n,{gamma}) reaction was measured with the DANCE {gamma} calorimeter (consisting of 160 BaF{sub 2} scintillation detectors) at the Los Alamos Neutron Science Center. The multiplicity distributions of the {gamma} decay were used to determine the resonance spins up to E{sub n}=300 eV. The {gamma}-ray energy spectra for different multiplicities were measured for the s-wave resonances. The shapes of these spectra were compared with simulations based on the use of the DICEBOX statistical model code. Simulations showed that the scissors mode is required not only for the ground-state transitions but also for transitions between excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurements on stable nuclides in the rare-earth region with the Penning-trap mass spectrometer TRIGA-TRAP

The masses of 15 stable nuclides in the rare-earth region have been measured with the Penning-trap mass spectrometer TRIGA-TRAP. This is the first series of absolute mass measurements linking these nuclides to the atomic-mass standard {sup 12}C. Previously, nuclear reaction studies almost exclusively determined the literature values of these masses in the Atomic-Mass Evaluation. The TRIGA-TRAP results show deviations on the order of 3-4 standard deviations from the latest published values of the Atomic-Mass Evaluation 2003 for some cases. However, the binding-energy differences that are important for nuclear structure studies have been confirmed and improved. The new masses are discussed in the context of valence proton-neutron interactions using double differences of binding energies, {delta}V{sub pn}(Z,N).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Mass Difference between t and t Quarks

We present a direct measurement of the mass difference between t and t quarks using tt candidate events in the lepton+jets channel, collected with the CDF II detector at Fermilab's 1.96 TeV Tevatron pp Collider. We make an event by event estimate of the mass difference to construct templates for top quark pair signal events and background events. The resulting mass difference distribution of data is compared to templates of signals and background using a maximum likelihood fit. From a sample corresponding to an integrated luminosity of 5.6 fb{sup -1}, we measure a mass difference, {Delta}M{sub top}=M{sub t}-M{sub t}=-3.3{+-}1.4(stat){+-}1.0(syst) GeV/c{sup 2}, approximately 2 standard deviations away from the CPT hypothesis of zero mass difference.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Ionic Conductivity and Electrode Polarization at Low Temperatures on 8YSZ by a DC Technique

Measurement of ionic conductivity and electrode polarization resistance on a 8YSZ sample with platinum paste electrodes was conducted using a DC method with high input impedance meters over a temperature range from 119°C to 589°C. Over the entire temperature range, the meter resistance was much larger than the sample resistance including the polarization resistance. At lower temperatures, a faraday cage was used to minimize noise. The measured polarization resistance was also verified using electrochemical impedance spectroscopy. Ionic conductivity of 8YSZ exhibited Arrhenius behavior with an activation energy of ~1.1 eV, in good agreement with the literature. In the low current regime, electrode kinetics could be described by the linearized form of the Butler-Volmer equation. At higher current densities, electrode kinetics exhibited Tafel behavior. The polarization resistance exhibited Arrhenius behavior with the activation energy ranging between 1.05 and 1.27 eV. The present work shows that electrode polarizations can be investigated using a DC method. The approach may allow study of different electrodes in various atmospheres using one sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Science and Measurement Requirements for a Plant Physiology and Functional Types Mission: Measuring the Composition, Function and Health of Global Land and Coastal Ocean Ecosystems

This slide presentation reviews the proposed Plant Physiology and Functional Types (PPFT) Mission. The National Academy of Sciences Decadal Survey, placed a critical priority on a Mission to observe distribution and changes in ecosystem functions. The PPFT satellite mission provides the essential measurements needed to assess drivers of change in biodiversity and ecosystem services that affect human welfare. The presentation reviews the science questions that the mission will be designed to answer, the science rationale, the science measurements, the mission concept, the planned instrumentation, the calibration method, and key signal to noise ratios and uniformity requirements.

science measurements↗

The Recommendations for Linear Measurement Techniques on the Measurements of Nonlinear System Parameters of a Joint.

In the study of the dynamics of nonlinear systems, experimental measurements often convolute the response of the nonlinearity of interest and the effects of the experimental setup. To reduce the influence of the experimental setup on the deduction of the parameters of the nonlinearity, the response of a mechanical joint is investigated under various experimental setups. These experiments first focus on quantifying how support structures and measurement techniques affect the natural frequency and damping of a linear system. The results indicate that support structures created from bungees have negligible influence on the system in terms of frequency and damping ratio variations. The study then focuses on the effects of the excitation technique on the response for a linear system. The findings suggest that thinner stingers should not be used, because under the high force requirements the stinger bending modes are excited adding unwanted torsional coupling. The optimal configuration for testing the linear system is then applied to a nonlinear system in order to assess the robustness of the test configuration. Finally, recommendations are made for conducting experiments on nonlinear systems using conventional/linear testing techniques.

36 MATERIALS SCIENCE↗

Seven years of aerosol scattering hygroscopic growth measurements from SGP: Factors influencing water uptake: Aerosol Scattering Hygroscopic Growth

Long-term measurements of changes in the aerosol scattering coefficient hygroscopic growth at the U.S. Department of Energy Southern Great Plains site provide information on the seasonal as well as size and chemical dependence of aerosol hygroscopic growth. Annual average sub 10 um fRH values (the ratio of aerosol scattering at 85%/40% RH) were 1.75 and 1.87 for the gamma and kappa fit algorithms, respectively. The study found higher growth rates in the winter and spring seasons that correlated with high aerosol nitrate mass fraction. FRH, exhibited strong, but differing correlations with the scattering Ångström exponent and backscatter fraction, two optical size-dependent parameters. The aerosol organic fraction had a strong influence, with fRH decreasing with increases in the organic mass fraction and absorption Ångström exponent and increasing with the aerosol single scatter albedo. Uncertainty analysis if the fit algorithms revealed high uncertainty at low scattering coefficients and slight increases in uncertainty at high RH and fit parameters values.

Jefferson, A.↗

Machine Learning Methods for Connection RTT and Loss Rate Estimation Using MPI Measurements Under Random Losses

Scientific computations are expected to be increasingly distributed across wide-area networks, and Message Passing Interface (MPI) has been shown to scale to support their communications over long distances. Application-level measurements of MPI operations reflect the connection Round-Trip Time (RTT) and loss rate, and machine learning methods have been previously developed to estimate them under deterministic periodic losses. In this paper, we consider more complex, random losses with unform, Poisson and Gaussian distributions. We study five disparate machine leaning methods, with linear and non-linear, and smooth and non-smooth properties, to estimate RTT and loss rate over 10Gbps connections with 0-366ms RTT. The diversity and complexity of these estimators combined with the randomness of losses and TCP’s non-linear response together rule out the selection of a single best among them; instead, we fuse them to retain their design diversity. Overall, the results show that accurate estimates can be generated at low loss rates but become inaccurate at loss rates 10% and higher, thereby illustrating both their strengths and limitations.