Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Evanescent wave decomposition in a novel resonator comprising unmagnetized and magnetized plasma layers

A 4 Multiplication-Sign 4 transfer matrix method has been applied to study the decomposition of any elliptically polarized wave in a magnetized resonator. When the incident elliptically polarized wave passes through the structure, it is orthogonally decomposed into two circular polarizations at two resonance frequencies. Without changing the structure of the resonator, the positions of the resonant frequencies of the right- and left-handed circularly polarized waves can be modulated by changing the external magnetized field. The results show that the proposed magnetized structure can be used to design a novel resonator, which can be applied in the decomposition of polarized electromagnetic waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic and Resonant Properties of Fe–Bi Films

Film structures in the Fe–Bi system have been studied experimentally. The magnetic state of the two-layer structures is shown by electron magnetic resonance to be dependent on the order of depositing magnetic and nonmagnetic layers. The three-layer structures demonstrate the effect of the exchange bias, the value of which is dependent on the bismuth interlayer thickness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated microchip incorporating atomic magnetometer and microfluidic channel for NMR and MRI

An integral microfluidic device includes an alkali vapor cell and microfluidic channel, which can be used to detect magnetism for nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Small magnetic fields in the vicinity of the vapor cell can be measured by optically polarizing and probing the spin precession in the small magnetic field. This can then be used to detect the magnetic field of in encoded analyte in the adjacent microfluidic channel. The magnetism in the microfluidic channel can be modulated by applying an appropriate series of radio or audio frequency pulses upstream from the microfluidic chip (the remote detection modality) to yield a sensitive means of detecting NMR and MRI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Sequences for Hyperpolarized Solids

Hyperpolarization is one of the approaches to enhance Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) signal by increasing the population difference between the nuclear spin states. Imaging hyperpolarized solids opens up extensive possibilities, yet is challenging to perform. The highly populated state is normally not replenishable to the initial polarization level by spin-lattice relaxation, which regular MRI sequences rely on. This makes it necessary to carefully “budget” the polarization to optimize the image quality. In this paper, we present a theoretical framework to address such challenge under the assumption of either variable flip angles or a constant flip angle. In addition, we analyze the gradient arrangement to perform fast imaging to overcome intrinsic short decoherence in solids. Hyperpolarized diamonds imaging is demonstrated as a prototypical platform to test the theory.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic Mesocellular Foam Functionalized by Curcumin for Potential Multifunctional Therapeutics

The study investigates curcumin/SPIONs hybridized mesocellular foam type silica for potential dual purpose of drug delivery (curcumin) and magnetic resonance imaging. Magnetization capability and curcumin release was assessed for different structured silica such as spherical silica (Q-10), Si-MCM-41, Si-SBA-16, mesocellular foam (MSU-Foam), Si-KIT-6, ULPFDU-12, and silicalite. The phase, textural, and morphological variation was systematically scrutinized using various physico-chemical techniques. Ten weight percent SPIONs loading was found to generate magnetically active SPIONs in the following order: Q-10 (1.44 emu/g) > SBA-16 (0.80 emu/g) > MSU-Foam (0.24 emu/g) > Si-MCM-41 (0.07 emu/g) > Si-KIT-6 (0.07 emu/g) > silicalite (0.08 emu/g), respectively. The iron oxide dispersion, specific surface area, and porosity play a major role in various structured silicas. MSU-Foam with wormhole structure showed highest specific surface area occupation of SPIONs (73%). The presence of interconnected porosity of foam tends to generate external agglomeration of SPIONs (7–18 nm) at the pore surface contributing to expansion of pore sizes from 16.4 to 40.2 nm. The SPIONs over spherical micron-sized silica Q-10 showed the formation of large nanoclusters (10–25 nm). Thirty to 390 μg/ml of curcumin was loaded over silica and SPIONs/silica structured hybrid, and drug release was studied at pH 5.6 for 72 h. SPIONs/MSU-Foam with less magnetization showed the highest cumulative curcumin release (53.2%), while Q-10 spherical silica with high magnetization property showed less cumulative release of curcumin (12%).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A magnetic gradient induced force in NMR restricted diffusion experiments

We predict that the phase cancellation of a precessing magnetisation field carried by a diffusing species in a bounded geometry under certain nuclear magnetic resonance pulsed magnetic field gradient sequences results in a small force over typically micrometre length scales. Our calculations reveal that the total magnetisation energy in a pore under the influence of a pulsed gradient will be distance-dependent thus resulting in a force acting on the boundary. It is shown that this effect of the magnetisation of diffusing particles will appear as either an attractive or repulsive force depending on the geometry of the pore and magnetic properties of the material. A detailed analysis is performed for the case of a pulsed gradient spin-echo experiment on parallel planes. It is shown that the force decays exponentially in terms of the spin-spin relaxation. The proof is based on classical electrodynamics. An application of this effect to soft matter is suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conceptual design of HTS magnets for fusion nuclear science facility

Second-generation high temperature superconductors (HTS) are available for producing >20 T at the magnet bore compared to 13–16 T for lower temperature superconducting (LTS) toroidal field magnets proposed in recent fusion energy systems studies (FESS) of Fusion Nuclear Science Facility (FNSF). HTS may enable higher fusion power density and smaller device size. High current density cables of multi-layered REBCO tapes have achieved >10 kA at 4–20 K operation in short sample tests for fusion. High current density cables are required for engineering design of FNSF to allow space for interior plasma components. High current density HTS magnets are particularly attractive in reducing the size of a fusion device, beneficial for compact tokamaks, due to their space constraints. Successful HTS magnet development may enable the design of smaller and cheaper fusion pilot plants with a mission of demonstrating net electricity. It may also offer significant cost and performance advantages in non-fusion applicants such as nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Furthermore, we developed HTS magnet design concepts for a compact FNSF radial build in order to define the coil size, winding pack mechanical loading and engineering requirements. Partnering with vendors in the US, PPPL is also testing high current cable prototypes aiming at enabling low cost cable technology toward 100 A/mm 2 engineering current density over the winding pack desired in high field model coil development for compact fusion pilot plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation between mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which could aid in individualizing therapy, particularly for patients at risk for liver injury after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevention of disuse osteoporosis: Effect of sodium fluoride during five weeks of bed rest

An attempt was made to modify factors which promote disuse osteoporosis and thereby prevent it from occurring. Since fluoride is currently used to enhance bone formation in the treatment of low turnover osteoporosis, it was hypothesized that if the fluoride ion was available over a long period of time that it would slow the demonstrated loss of calcium by inhibiting bone resorption and enhancing bone formation. This study was used to determine whether oral medication with sodium F will modify or prevent 5 weeks of bed rest induced disuse osteoporosis, to determine the longitudinal effects of 5 weeks of bed rest on PTH, CT and calcitriol, to measure muscle volume changes and metabolic activity by magnetic resonance imaging and magnetic resonance spectroscopy during prolonged bed rest, to measure changes in peak muscle strength and fatigability, and to measure bone turnover in bone biopsies. Subjects were studied during 1 week of equilibration, 4 weeks of control ambulation, 5 weeks of bed rest, and 1 week of reambulation.

Schneider, Victor S.↗

Making Superconducting Welds between Superconducting Wires

A technique for making superconducting joints between wires made of dissimilar superconducting metals has been devised. The technique is especially suitable for fabrication of superconducting circuits needed to support persistent electric currents in electromagnets in diverse cryogenic applications. Examples of such electromagnets include those in nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) systems and in superconducting quantum interference devices (SQUIDs). Sometimes, it is desirable to fabricate different parts of a persistent-current-supporting superconducting loop from different metals. For example, a sensory coil in a SQUID might be made of Pb, a Pb/Sn alloy, or a Cu wire plated with Pb/Sn, while the connections to the sensory coil might be made via Nb or Nb/Ti wires. Conventional wire-bonding techniques, including resistance spot welding and pressed contact, are not workable because of large differences between the hardnesses and melting temperatures of the different metals. The present technique is not subject to this limitation. The present technique involves the use (1) of a cheap, miniature, easy-to-operate, capacitor-discharging welding apparatus that has an Nb or Nb/Ti tip and operates with a continuous local flow of gaseous helium and (2) preparation of a joint in a special spark-discharge welding geometry. In a typical application, a piece of Nb foil about 25 m thick is rolled to form a tube, into which is inserted a wire that one seeks to weld to the tube (see figure). The tube can be slightly crimped for mechanical stability. Then a spark weld is made by use of the aforementioned apparatus with energy and time settings chosen to melt a small section of the niobium foil. The energy setting corresponds to the setting of a voltage to which the capacitor is charged. In an experiment, the technique was used to weld an Nb foil to a copper wire coated with a Pb/Sn soft solder, which is superconducting. The joint was evaluated as part of a persistent-current circuit having an inductance of 1 mH. A current was induced in a loop, and no attenuation of the current after a time interval 1,000 s was discernible in a measurement having a fractional accuracy of 10(exp -4): This observation supports the conclusion that the weld had an electrical resistance <10(exp -10) omega.

Penanen, Konstantin I.↗

Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytic description of atomic interaction at ultracold temperatures. II. Scattering around a magnetic Feshbach resonance

Starting from a multichannel quantum-defect theory, we derive analytic descriptions of a magnetic Feshbach resonance in an arbitrary partial wave l and the atomic interactions around it. An analytic formula, applicable to both broad and narrow resonances of arbitrary l, is presented for ultracold atomic scattering around a Feshbach resonance. Other related issues addressed include (a) the parametrization of a magnetic Feshbach resonance of arbitrary l, (b) rigorous definitions of ''broad'' and ''narrow'' resonances of arbitrary l and their different scattering characteristics, and (c) the tuning of the effective range and the generalized effective range by a magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetically tunable resonator

Provided is a process for manufacturing magnetically tunable nano-resonators. The nano-resonators comprise nanoparticles of a crystalline magnetic material embedded into cavities of a substrate.

Blick, Robert↗

RTOG Sarcoma Radiation Oncologists Reach Consensus on Gross Tumor Volume and Clinical Target Volume on Computed Tomographic Images for Preoperative Radiotherapy of Primary Soft Tissue Sarcoma of Extremity in Radiation Therapy Oncology Group Studies

Objective: To develop a Radiation Therapy Oncology Group (RTOG) atlas delineating gross tumor volume (GTV) and clinical target volume (CTV) to be used for preoperative radiotherapy of primary extremity soft tissue sarcoma (STS). Methods and Materials: A consensus meeting was held during the RTOG meeting in January 2010 to reach agreement about GTV and CTV delineation on computed tomography (CT) images for preoperative radiotherapy of high-grade large extremity STS. Data were presented to address the local extension of STS. Extensive discussion ensued to develop optimal criteria for GTV and CTV delineation on CT images. Results: A consensus was reached on appropriate CT-based GTV and CTV. The GTV is gross tumor defined by T1 contrast-enhanced magnetic resonance images. Fusion of magnetic resonance and images is recommended to delineate the GTV. The CTV for high-grade large STS typically includes the GTV plus 3-cm margins in the longitudinal directions. If this causes the field to extend beyond the compartment, the field can be shortened to include the end of a compartment. The radial margin from the lesion should be 1.5 cm, including any portion of the tumor not confined by an intact fascial barrier, bone, or skin surface. Conclusion: The consensus on GTV and CTV for preoperative radiotherapy of high-grade large extremity STS is available as web-based images and in a descriptive format through the RTOG. This is expected to improve target volume consistency and allow for rigorous evaluation of the benefits and risks of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis, in vitro assays, molecular docking, theoretical ADMET prediction, and evaluation of 4-methoxy-phenylthiazole-2-amine derivatives as acetylcholinesterase inhibitors

Based on the cholinergic hypothesis of the reported compound, N-(4-(4-methoxy-phenyl)thiazol-2-yl)-3-(pyrrolidin-1-yl)propionamide, which had a good inhibitory activity to acetylcholinesterase (AChE), the new 4-methoxy-phenylthiazole-2-amine derivatives as AChE inhibitors (AChEIs) have been designed and synthesized in this study. Their chemical structures were confirmed by proton nuclear magnetic resonance, carbon-13 nuclear magnetic resonance, mass spectrometry, and infrared. Furthermore, their inhibitory activities against AChE in vitro were also tested by Ellman spectrophotometry, and the inhibitory activity test results showed that most of the compounds of 4-methoxy-phenylthiazole-2-amine derivatives had a certain AChE inhibitory activity in vitro, and the IC{sub 50} (half-maximal inhibitory concentration) value of compound 5g was 5.84 μmol/L, which was higher than that of the reference compound, rivastigmine. Moreover, it had almost no inhibitory effect on butyrylcholinesterase. In addition, compound 5g was subjected to enzyme inhibition kinetics experiments, and the result of Lineweaver–Burk’s V{sup −1}–[S]{sup −1} double-reciprocal plot showed that the acting type of compound 5g was mixed inhibition type. Furthermore, the AChE inhibitory activity mechanism of compound 5g was explored by the conformational analysis and molecular docking, which was based on the principle of the four-point pharmacophore model necessary for AChE inhibition. Finally, in silico molecular property and ADMET (absorption, distribution, metabolism, excretion, and toxicity) of the synthesized compounds were predicted by using Molinspiration and PreADMET online servers, respectively. It can be concluded that the lead AChEI compound 5g presented satisfactory drug-like characteristics and ADME properties.

60 APPLIED LIFE SCIENCES↗

SU-C-204-05: Magnetic Resonance-Induced Adaptive Response to Orthovoltage Radiation Therapy in FSa and SA-NH Mouse Tumor Cell Lines

Purpose: To assess the effect of pre-treatment Magnetic Resonance Imaging (MRI) on cell survival following orthovoltage radiation therapy. Methods: This in vitro study examined the survival of FSa cells (extracted from methylcholanthrene-induced fibrosarcoma in the flank of a C3H female mouse) and SA-NH cells (derived from a spontaneously arising murine sarcoma tumor) having undergone an MRI scan prior to radiation exposure. Cell cultures were kept at 37 C, in a humidified environment with 5% CO2, and were grown to confluence prior to the start of the experiment. Each cell culture underwent two, 25 minute MRIs spaced 24 hours apart using a standard brain imaging protocol. The cultures were exposed to a 2 Gy dose of radiation beginning 15 minutes after the end of each MRI scan. Irradiations were performed by a Philips RT250 X-ray generator at 250 kVp and 15 mA. All MR imaging was performed on a 1.5 T Philips Achieva scanner using a head and neck vasculature coil. Results: Cells given an MRI scan prior to radiation exhibited an increase in mean surviving fraction of 10.8% and 9.6% in FSa and SA-NH cells, respectively. The difference was found to be statistically significant in both cell types by a student two-tailed t test with P = 0.011 and P < 0.001 for FSa and SA-NH, respectively. Conclusion: MRI may cause an increase in radio-resistance in FSa and SA-NH cells. If this biological effect is found to be consistent across other cell types and voltage ranges, these results could help inform treatment planning by improving our understanding of the joint effects of MRI and ionizing radiation. This work was supported in part under NIH grant numbers T32 EB002103, NCI R01-CA 132998, DOE Low Dose Program/Project Grant DE-413 SC0001271. DJ Grdina is a paid consultant to Pinnacle Biologics. DJ Grdina and JS Murley are minority equity partners in Pinnacle Oncology LLC.

60 APPLIED LIFE SCIENCES↗

Optical and magneto-optical properties of one-dimensional magnetized coupled resonator plasma photonic crystals

In this paper, the optical and magneto-optical properties of one-dimensional magnetized coupled resonator plasma photonic crystals have been investigated. We use transfer matrix method to solve our magnetized coupled resonator plasma photonic crystals consist of dielectric and magnetized plasma layers. The results of the change in the optical and magneto-optical properties of structure as a result of the alteration in the structural properties such as thickness, plasma frequency and collision frequency, plasma filling factor, number of resonators and dielectric constant of dielectric layers and external magnetic field have been reported. The main feature of this structure is a good magneto-optical rotation that takes place at the defect modes and the edge of photonic band gap of our proposed optical magnetized plasma waveguide. Our outcomes demonstrate the potential applications of the device for tunable and adjustable filters or reflectors and active magneto-optic in microwave devices under structural parameter and external magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy

Purpose: The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. Methods and Materials: A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dose metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Results: Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: −0.1 to 0.2%) for D{sub 95%}; 0.0% (−0.7 to 0.6%) for D{sub 5%}; and −0.2% (−1.0 to 0.2%) for D{sub max}. MRCT plans showed no significant changes in monitor units (−0.4%) compared to CT plans. Organs at risk (OARs) had average D{sub max} differences of 0.0 Gy (−2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Conclusions: Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗