Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Real-Time Parameter Estimation in the Frequency Domain

A method for real-time estimation of parameters in a linear dynamic state-space model was developed and studied. The application is aircraft dynamic model parameter estimation from measured data in flight. Equation error in the frequency domain was used with a recursive Fourier transform for the real-time data analysis. Linear and nonlinear simulation examples and flight test data from the F-18 High Alpha Research Vehicle were used to demonstrate that the technique produces accurate model parameter estimates with appropriate error bounds. Parameter estimates converged in less than one cycle of the dominant dynamic mode, using no a priori information, with control surface inputs measured in flight during ordinary piloted maneuvers. The real-time parameter estimation method has low computational requirements and could be implemented

Morelli, Eugene A.↗

Search and rescue satellite (SARSAT) error analysis of the 406 MHz system

A computer simulation investigated conditions encountered by the SARSAT 406 MHz system. Three and four parameter emergency transmitter (ET) location solutions were determined. Latitude and longitude, a frequency bias, and in the four-parameters solutions, a linear frequency drift term were estimated. Earth gravity, frequency drift, and measurement noise are the major error contributors to the ET position. Time-tag ET height and velocity errors, although significant are not routinely present. In the four-parameter solutions the drift error is eliminated; however, the sensitivity to measurement noise increases. Using the four-parameter pass solutions, the 406 MHz oscillator specifications can be relaxed and still satisfy the 5 km positioning requirement. Since a linear oscillator drift is removed in the four-parameter solution, only the measurement noise over 10-15 min is important.

Yionoulis, S. M.↗

Non-linear dynamics of a spur gear pair

The backlash nonlinearity excited primarily by transmission error between spur gear pairs is studied for both external and internal excitations. The digital simulation technique and the method of harmonic balance are used to develop steady state solutions for the internal sinuosidal excitations. The analytic predictions agreed well with available experimental data. Digital simulation is used to observe that at the chaotic and subharmonic resonances may exist in a gear pair depending on the mean or design load, mean to alternating force ratio, damping, and backlash.

Kahraman, A.↗

General Protocol for the Accurate Prediction of Molecular 13 C/ 1 H NMR Chemical Shifts via Machine Learning Augmented DFT

An accurate prediction of NMR chemical shifts at affordable computational cost is very important for different types of structural assignments in experimental studies. Density functional theory (DFT) and gauge-including atomic orbital (GIAO) are two of the most popular computational methods for NMR calculation, yet they often fail to resolve ambiguities in structural assignments. In this work, we present a new method that uses machine learning (ML) techniques (DFT + ML) that significantly increases the accuracy of 13 C/ 1 H NMR chemical shift prediction for a variety of organic molecules. The input of the generalizable DFT + ML model contains two critical parts: one is a vector providing insights into chemical environments, which can be evaluated without knowing the exact geometry of the molecule; the other one is the DFT-calculated isotropic shielding constant. The DFT + ML model was trained with a data set containing 476 13 C and 270 1 H experimental chemical shifts. For the DFT methods used here, the root mean square deviations (RMSDs) for the errors between predicted and experimental 13 C/ 1 H chemical shifts can be as small as 2.10/0.18 ppm, which is much lower than those from simple DFT (5.54/0.25 ppm), or DFT + linear regression (LR) (4.77/0.23 ppm) approaches. It also has a smaller maximum absolute error than two previously proposed NMR-predicting ML models. The robustness of the DFT + ML model is tested on two classes of organic molecules (TIC10 and hyacinthacines), where the correct isomers were unambiguously assigned to the experimental ones. Overall, the DFT + ML model shows promise for structural assignments in a variety of systems, including stereoisomers, that are often challenging to determine experimentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-linear dynamic compensation system

A non-linear dynamic compensation subsystem is added in the feedback loop of a high precision optical mirror positioning control system to smoothly alter the control system response bandwidth from a relatively wide response bandwidth optimized for speed of control system response to a bandwidth sufficiently narrow to reduce position errors resulting from the quantization noise inherent in the inductosyn used to measure mirror position. The non-linear dynamic compensation system includes a limiter for limiting the error signal within preselected limits, a compensator for modifying the limiter output to achieve the reduced bandwidth response, and an adder for combining the modified error signal with the difference between the limited and unlimited error signals. The adder output is applied to control system motor so that the system response is optimized for accuracy when the error signal is within the preselected limits, optimized for speed of response when the error signal is substantially beyond the preselected limits and smoothly varied therebetween as the error signal approaches the preselected limits.

Lin, Yu-Hwan↗

Effects of electron viscosity on resonant layer responses to non-axisymmetric magnetic perturbations

The resonant field penetration to magnetic islands is the central MHD mechanism of non-axisymmetric plasma responses in a tokamak such as disruptive locking or favorable ELM stabilization. The resonant field penetration can be induced by any non-ideal processes as manifested in the delicate balance under the generalized Ohm's law. Here, we show that the viscous effects by electrons are not ignorable in the field penetration unlike previous presumption, even if the electron viscosity is as small as the square root of its mass compared to the ions. It is clear that its effects become only bigger if the electron viscosity becomes anomalously large. The work strictly follows the three-field model in the linear regime targeting the prediction of the onset of the field penetration and successfully extending it with electron viscosity and identifying new regimes. The results also indicate that the error field thresholds become more strongly dependent on plasma density than ones predicted in the linear regimes without the electron viscosity, which is consistent with experimental observations and thus a significant implication.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-FG-BRA-06: Electromagnetic Beacon Insertion in Lung Cancer Patients and Resultant Surrogacy Errors for Dynamic MLC Tumour Tracking

Purpose: To assess endo-bronchial electromagnetic beacon insertion and to quantify the geometric accuracy of using beacons as a surrogate for tumour motion in real-time multileaf collimator (MLC) tracking of lung tumours. Methods: The LIGHT SABR trial is a world-first clinical trial in which the MLC leaves move with lung tumours in real time on a standard linear accelerator. Tracking is performed based on implanted electromagnetic beacons (CalypsoTM, Varian Medical Systems, USA) as a surrogate for tumour motion. Five patients have been treated and have each had three beacons implanted endo-bronchially under fluoroscopic guidance. The centre of mass (C.O.M) has been used to adapt the MLC in real-time. The geometric error in using the beacon C.O.M as a surrogate for tumour motion was measured by measuring the tumour and beacon C.O.M in all phases of the respiratory cycle of a 4DCT. The surrogacy error was defined as the difference in beacon and tumour C.O.M relative to the reference phase (maximum exhale). Results: All five patients have had three beacons successfully implanted with no migration between simulation and end of treatment. Beacon placement relative to tumour C.O.M varied from 14 to 74 mm and in one patient spanned two lobes. Surrogacy error was measured in each patient on the simulation 4DCT and ranged from 0 to 3 mm. Surrogacy error as measured on 4DCT was subject to artefacts in mid-ventilation phases. Surrogacy error was a function of breathing phase and was typically larger at maximum inhale. Conclusion: Beacon placement and thus surrogacy error is a major component of geometric uncertainty in MLC tracking of lung tumours. Surrogacy error must be measured on each patient and incorporated into margin calculation. Reduction of surrogacy error is limited by airway anatomy, however should be taken into consideration when performing beacon insertion and planning. This research is funded by Varian Medical Systems via a collaborative research agreement.

60 APPLIED LIFE SCIENCES↗

The linear model and experimentally observed resonant field amplification in tokamaks and reversed field pinches

A review is given of the experimentally observed effects related to the resonant field amplification (RFA) and the Resistive Wall Mode (RWM) instability in tokamaks and reversed field pinches (RFPs). This includes the feedback rotation of RWM in RFX-mod RFP, dependence of the RWM growth rate on the plasma-wall separation observed in JT-60U, appearance of the slowly growing RWM precursors in JT-60U and similar phenomena in other devices. The experimental results are compared with theoretical predictions based on the model comprising the Maxwell equations, Ohm's law for the conducting wall, the boundary conditions and assumption of linear plasma response to the external magnetic perturbations. The model describes the plasma reaction to the error field as essentially depending on two factors: the plasma proximity to the RWM stability threshold and the natural rotation frequency of the plasma mode. The linear response means that these characteristics are determined by the plasma equilibrium parameters only. It is shown that the mentioned effects in different devices under different conditions can be described on a common basis with only assumption that the plasma behaves as a linear system. To extend the range of the model validation, some predictions are derived with proposals for experimental studies of the RFA dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Practical robustness measures in multivariable control system analysis

The robustness of the stability of multivariable linear time invariant feedback control systems with respect to model uncertainty is considered using frequency domain criteria. Available robustness tests are unified under a common framework based on the nature and structure of model errors. These results are derived using a multivariable version of Nyquist's stability theorem in which the minimum singular value of the return difference transfer matrix is shown to be the multivariable generalization of the distance to the critical point on a single input, single output Nyquist diagram. Using the return difference transfer matrix, a very general robustness theorem is presented from which all of the robustness tests dealing with specific model errors may be derived. The robustness tests that explicitly utilized model error structure are able to guarantee feedback system stability in the face of model errors of larger magnitude than those robustness tests that do not. The robustness of linear quadratic Gaussian control systems are analyzed.

Lehtomaki, N. A.↗

Multi-Physics Surrogate Modeling with Dimensionality Reduction

This summary provides a new algorithm to construct surrogate models for multi-physics, nonlinear, high dimensional models which typically suffer from the curse of dimensionality. To deal with the high computational cost and difficult error estimation, we employ recent advances in reduced order modeling (ROM) techniques to do an error-preserving reduction for the number of influential model parameters, followed by a conventional surrogate construction process. To implement ROM for a multiphysics model, a range finding algorithm (RFA) is used to identify a linear transformation in which the number of influential parameters can be minimized and the errors resulting from the non-influential parameters can be upper-bounded. The proposed algorithm is applied to the MAMMOTH coupled code system developed at the Idaho National Laboratory. In particular, we investigate the reducibility of Rattlesnake and BISON codes and their multi-physics coupling. The most important result of this work is that the reduction obtained with coupled physics is more significant than that with individual physics models. This summary explores the application of ROM techniques on multi-physics coupling codes system. Concise methodology is provided and selected numerical results are provided to show that coupling system provides additional reduction at interfaces. Future work could be invested to determine the optimum surrogate model format. (authors)

97 MATHEMATICS AND COMPUTING↗

Perturbative Stability and Error-Correction Thresholds of Quantum Codes

Topologically ordered phases are stable to local perturbations, and topological quantum error-correcting codes enjoy thresholds to local errors. We connect the two notions of stability by constructing classical statistical mechanics models for decoding general Calderbank-Shor-Steane codes and classical linear codes. Our construction encodes correction success probabilities under uncorrelated bit-flip and phase-flip errors, and simultaneously describes a generalized ℤ 2 lattice-gauge theory with quenched disorder. We observe that the clean limit of the latter is precisely the discretized imaginary-time path integral of the corresponding quantum code Hamiltonian when the errors are turned into a perturbative 𝑋 or 𝑍 magnetic field. Motivated by error-correction considerations, we define general order parameters for all such generalized ℤ 2 lattice-gauge theories, and show that they are generally lower bounded by success probabilities of error correction. For CSS codes satisfying the low-density parity-check condition and with a sufficiently large code distance, we prove the existence of a low-temperature ordered phase of the corresponding lattice-gauge theories, particularly for those lacking Euclidean spatial locality and/or when there is a nonzero code rate. We further argue that these results provide evidence for stable phases in the corresponding perturbed quantum Hamiltonians, obtained in the limit of continuous imaginary time. To do so, we distinguish space- and timelike defects in the lattice-gauge theory. A high free-energy cost of spacelike defects corresponds to a successful “memory experiment” and suppresses the energy splitting among the ground states, while a high free-energy cost of timelike defects corresponds to a successful “stability experiment” and points to a nonzero gap to local excitations.

quantum error correction↗

Dual-rail encoding with superconducting cavities

The design of quantum hardware that reduces and mitigates errors is essential for practical quantum error correction (QEC) and useful quantum computation. To this end, we introduce the circuit-Quantum Electrodynamics (QED) dual-rail qubit in which our physical qubit is encoded in the single-photon subspace, { | 01 〉 , | 10 〉 } , of two superconducting microwave cavities. The dominant photon loss errors can be detected and converted into erasure errors, which are in general much easier to correct. In contrast to linear optics, a circuit-QED implementation of the dual-rail code offers unique capabilities. Using just one additional transmon ancilla per dual-rail qubit, we describe how to perform a gate-based set of universal operations that includes state preparation, logical readout, and parametrizable single and two-qubit gates. Moreover, first-order hardware errors in the cavities and the transmon can be detected and converted to erasure errors in all operations, leaving background Pauli errors that are orders of magnitude smaller. Hence, the dual-rail cavity qubit exhibits a favorable hierarchy of error rates and is expected to perform well below the relevant QEC thresholds with today’s coherence times.

97 MATHEMATICS AND COMPUTING↗

Calibrating ground‐based microwave radiometers: Uncertainty and drifts

Abstract The quality of microwave radiometer (MWR) calibrations, including both the absolute radiometric accuracy and the spectral consistency, determines the accuracy of geophysical retrievals. The Microwave Radiometer Calibration Experiment (MiRaCalE) was conducted to evaluate the performance of MWR calibration techniques, especially of the so‐called Tipping Curve Calibrations (TCC) and Liquid Nitrogen Calibrations (LN2cal), by repeatedly calibrating a fourth‐generation Humidity and Temperature Profiler (HATPRO‐G4) that measures downwelling radiance between 20 GHz and 60 GHz. MiRaCalE revealed two major points to improve MWR calibrations: (i) the necessary repetition frequency for MWR calibration techniques to correct drifts, which ensures stable long‐term measurements; and (ii) the spectral consistency of control measurements of a well known reference is useful to estimate calibration accuracy. Besides, we determined the accuracy of the HATPRO's liquid nitrogen‐cooled blackbody's temperature. TCCs and LN2cals were found to agree within 0.5 K when observing the liquid nitrogen‐cooled blackbody with a physical temperature of 77 K. This agreement of two different calibration techniques suggests that the brightness temperature of the LN2 cooled blackbody is accurate within at least 0.5 K, which is a significant reduction of the uncertainties that have been assumed to vary between 0.6 K and 1.5 K when calibrating the HATPRO‐G4. The error propagation of both techniques was found to behave almost linearly, leading to maximum uncertainties of 0.7 K when observing a scene that is associated with a brightness temperature of 15 K.

Küchler, N.↗

Two-body potential model based on cosine series expansion for ionic materials

There is a method to construct a two-body potential model for ionic materials with a Fourier series basis and we examine it. For this method, the coefficients of cosine basis functions are uniquely determined by solving simultaneous linear equations to minimize the sum of weighted mean square errors in energy, force and stress, where first-principles calculation results are used as the reference data. As a validation test of the method, potential models for magnesium oxide are constructed. The mean square errors appropriately converge with respect to the truncation of the cosine series. This result mathematically indicates that the constructed potential model is sufficiently close to the one that is achieved with the non-truncated Fourier series and demonstrates that this potential virtually provides minimum error from the reference data within the two-body representation. The constructed potential models work appropriately in both molecular statics and dynamics simulations, especially if a two-step correction to revise errors expected in the reference data is performed, and the models clearly outperform two existing Buckingham potential models that were tested. Moreover, the good agreement over a broad range of energies and forces with first-principles calculations should enable the prediction of materials behavior away from equilibrium conditions, such as a system under irradiation.

36 MATERIALS SCIENCE↗

A robust fourth-order finite-difference discretization for the strongly anisotropic transport equation in magnetized plasmas

We propose a second-order temporally implicit, fourth-order-accurate spatial discretization scheme for the strongly anisotropic heat transport equation characteristic of hot, fusion-grade plasmas. Following Du Toit et al. (2018), the scheme transforms mixed-derivative diffusion fluxes (which are responsible for the lack of a discrete maximum principle) into nonlinear advective fluxes, amenable to nonlinear-solver-friendly monotonicity-preserving limiters. The scheme enables accurate multi-dimensional heat transport simulations with up to seven orders of magnitude of heat-transport-coefficient anisotropies with low cross-field numerical error pollution and excellent algorithmic performance, with the number of linear iterations scaling very weakly with grid resolution and grid anisotropy, and scaling with the square-root of the implicit timestep. We propose a multigrid preconditioning strategy based on a lower-order approximation that renders the scheme efficient and scalable under grid refinement. Several numerical tests are presented that display the expected spatial convergence rates and strong algorithmic performance, including fully nonlinear magnetohydrodynamics simulations of kink instabilities in a Bennett pinch in 2D helical geometry and of ITER in 3D toroidal geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precise Lamb Shift Measurements in Hydrogen-Like Heavy Ions--Status and Perspectives

The precise determination of the energy of the Lyman {alpha}1 and {alpha}2 lines in hydrogen-like heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. For the first time, a calorimetric low-temperature detector was applied in an experiment to precisely determine the transition energy of the Lyman lines of lead ions {sup 207}pb{sup 81+} at the Experimental Storage Ring (ESR) at GSI. The detectors consist of silicon thermistors, provided by the NASA/Goddard Space Flight Center, and Pb or Sn absorbers to obtain high quantum efficiency in the energy range of 40-80 keV, where the Doppler-shifted Lyman lines are located. The measured energy of the Lyman {alpha}1 line, E(Ly-{alpha}1, {sup 207}Pb{sup 81+}) = (77937{+-}12{sub stat}{+-}23{sub syst}) eV, agrees within errors with theoretical predictions. The systematic error is mainly due to uncertainties in the non-linear energy calibration of the detectors as well as the relative position of detector and gas-jet target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning based unfolding of x-ray spectra from filter stack spectrometer data

We demonstrate the application of neural networks to perform x-ray spectra unfolding from data collected by filter stack spectrometers. A filter stack spectrometer consists of a series of filter-detector pairs, where the detectors behind each filter measure the energy deposition through each layer as photo-stimulated luminescence (PSL). The network is trained on synthetic data, assuming x-rays of energies < 1 MeV and of two different distribution functions (Maxwellian and Gaussian) and the corresponding measured PSL values obtained from five different filter stack spectrometer designs. Predicted unfolds of single distributions are near identical reproductions of the ground truth spectra, with differences in the values lower than 20% at the higher energy end in some cases. The neural network has also demonstrated robustness to experimental measurement errors of < 5% and some capability of performing unfolds for linear combinations of the two distributions without previous training. The network can perform unfolds at rates > 1 Hz, ideal for application to some high-repetition-rate systems.

47 OTHER INSTRUMENTATION↗