Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Response of a DRAM to single-ion tracks of different heavy-ion species and stopping powers

Multiple-bit errors caused by single-ion tracks in a 256-kb DRAM fabricated by a bulk process were observed for different ion species and stopping power values. The results demonstrate the utility of this device for the evaluation of ion-beam uniformity and ion-beam-induced charge collection in IC devices. The data indicate that single-ion-induced charge transport results in multiple-bit error clusters due to lateral diffusion of excess minority carriers (electrons). Charge collection occurred from a depth of up to 35 microns from the surface of the device. An apparent charge loss was observed for very heavy ions with a high stopping power (Au at 350 MeV).

Zoutendyk, J. A.↗

Sputtering of ions from Cu and Al by low energy oxygen ion bombardment

The sputtering of Cu(+) and Al(+) ions from copper and aluminum while the target surface is bombarded with low energy oxygen ions (20 to 500 eV), is investigated. Both the ion yield, as a function of oxygen ion energy, and the kinetic energy distribution of the sputtered ions at a given oxygen ion energy are determined.

Eck, T. G.↗

Observations of Reflected Ions and Plasma Turbulence for Satellite Potentials Greater than the Ion Ram Energy

During the TSS-1R mission, the behavior of the ions flowing from the forward hemisphere of the Tethered Satellite System (TSS) satellite was examined as the potential of the satellite was changed from below to above 5 V. The ram energy of the ambient atomic oxygen ions is approximately 5 eV. For satellite potentials less than 5 V, no ions were observed on the ram side of the satellite. When the satellite potential was raised greater than 5 V, ions were observed to be flowing from the forward region of the satellite. In the region sampled, the ion flux was a few percent of the ambient with energies of approximately 5 eV. The temperature of the out-flowing ions was observed to be enhanced, relative to the ambient ionosphere. The net current to the probe package became much more noisy for satellite potentials greater than 5 V as compared with satellite potentials less than 5 V, indicating a more disturbed plasma environment.

Wright, K. H., Jr.↗

Observations of Reflected Ions and Plasma Turbulence for Satellite Potentials Greater Than the Ion Ram Energy

During the TSS-1R mission, the behavior of the ions flowing from the forward hemisphere of the Tethered Satellite System (TSS) satellite was examined as the potential on the satellite was changed from below to above 5 Volts. The ram energy of the ambient atomic oxygen ions is about 5 eV. For satellite potentials less than 5 V, no ions were observed on the ram side of the satellite. When the satellite potential was raised above 5 V, ions were observed to be flowing from the forward region of the satellite. In the region sampled, the ion flux was a few percent of the ambient with energies of about 5 eV. The temperature of the outflowing ions was observed to be enhanced, relative to the ambient ionosphere, and had a maximum in a plane containing the center of the satellite and normal to the geomagnetic field. The net current to the probe package became much more noisy for satellite potentials above 5 V as compared with satellite potentials below 5 V indicating a more disturbed plasma environment.

Wright, K. H., Jr.↗

Computational Model Tracking Primary Electrons, Secondary Electrons, and Ions in the Discharge Chamber of an Ion Engine

Computational modeling of the plasma located in the discharge chamber of an ion engine is an important activity so that the development and design of the next generation of ion engines may be enhanced. In this work a computational tool called XOOPIC is used to model the primary electrons, secondary electrons, and ions inside the discharge chamber. The details of this computational tool are discussed in this paper. Preliminary results from XOOPIC are presented. The results presented include particle number density distributions for the primary electrons, the secondary electrons, and the ions. In addition the total number of a particular particle in the discharge chamber as a function of time, electric potential maps and magnetic field maps are presented. A primary electron number density plot from PRIMA is given in this paper so that the results of XOOPIC can be compared to it. PRIMA is a computer code that the present investigators have used in much of their previous work that provides results that compare well to experimental results. PRIMA only models the primary electrons in the discharge chamber. Modeling ions and secondary electrons, as well as the primary electrons, will greatly increase our ability to predict different characteristics of the plasma discharge used in an ion engine.

Mahalingam, Sudhakar↗

Energetic O+ and H+ Ions in the Plasma Sheet: Implications for the Transport of Ionospheric Ions

The present study statistically examines the characteristics of energetic ions in the plasma sheet using the Geotail/Energetic Particle and Ion Composition data. An emphasis is placed on the O+ ions, and the characteristics of the H+ ions are used as references. The following is a summary of the results. (1) The average O+ energy is lower during solar maximum and higher during solar minimum. A similar tendency is also found for the average H+ energy, but only for geomagnetically active times; (2) The O+ -to -H+ ratios of number and energy densities are several times higher during solar maximum than during solar minimum; (3) The average H+ and O+ energies and the O+ -to -H+ ratios of number and energy densities all increase with geomagnetic activity. The differences among different solar phases not only persist but also increase with increasing geomagnetic activity; (4) Whereas the average H+ energy increases toward Earth, the average O+ energy decreases toward Earth. The average energy increases toward dusk for both the H+ and O+ ions; (5) The O+ -to -H+ ratios of number and energy densities increase toward Earth during all solar phases, but most clearly during solar maximum. These results suggest that the solar illumination enhances the ionospheric outflow more effectively with increasing geomagnetic activity and that a significant portion of the O+ ions is transported directly from the ionosphere to the near ]Earth region rather than through the distant tail.

Ohtani, S.↗

Kuang's Semi-Classical Formalism for Electron Capture Cross-Sections in Ion-Ion Collisions at Approximately to MeV/amu: Application to ENA Modeling

Recent discovery by STEREO A/B of energetic neutral hydrogen is spurring an interest and need for reliable estimates of electron capture cross sections at few MeVs per nucleon as well as for multi-electron ions. Required accuracy in such estimates necessitates detailed and involved quantum-mechanical calculations or expensive numerical simulations. For ENA modeling and similar purposes, a semi-classical approach offers a middle-ground approach. Kuang's semiclassical formalism to calculate electron-capture cross sections for single and multi-electron ions is an elegant and efficient method, but has so far been applied to limited and specific laboratory measurements and at somewhat lower energies. Our goals are to test and extend Kuang s method to all ion-atom and ion-ion collisions relevant to ENA modeling, including multi-electron ions and for K-shell to K-shell transitions.

Barghouty, A. F.↗

Systems and Methods for Ejection of Ions from an Ion Trap

The invention generally relates to systems and methods for ejection of ions from an ion trap. In certain embodiments, systems and methods of the invention sum two different frequency signals into a single summed signal that is applied to an ion trap. In other embodiments, an amplitude of a single frequency signal is modulated as the single frequency signal is being applied to the ion trap. In other embodiments, a first alternating current (AC) signal is applied to an ion trap that varies as a function of time, while a constant radio frequency (RF) signal is applied to the ion trap.

Cooks, Robert Graham↗

Computational Investigation of the Near-Field Plasma Plume in Ion-Ion Propulsion

A two-fluid numerical model of plasma flows was developed to investigate the plume of an ion-ion propulsion system. The densities of positive and negative ions, and the associated values of net charge, electric field, and electric potential were calculated as a function of time throughout the domain. The computational domain was chosen to be large enough (25 thruster diameters downstream of the exit plane) to allow for examining the neutralization of the plume. The resulting plasma electric potential and charge neutrality at the downstream end of the domain are shown and they indicate that it is possible to alternatively accelerate oppositely charged ions without the need for an electron-emitting neutralizer and without facing any electric potential hills that could cause stagnation. However, compared to existing literature on ion-ion plasma thrusters, the results from this simulation predict a longer length-scale for voltage decay.

Sankaran, K.↗

Microchip and wedge ion funnels and planar ion beam analyzers using same

Electrodynamic ion funnels confine, guide, or focus ions in gases using the Dehmelt potential of oscillatory electric field. New funnel designs operating at or close to atmospheric gas pressure are described. Effective ion focusing at such pressures is enabled by fields of extreme amplitude and frequency, allowed in microscopic gaps that have much higher electrical breakdown thresholds in any gas than the macroscopic gaps of present funnels. The new microscopic-gap funnels are useful for interfacing atmospheric-pressure ionization sources to mass spectrometry (MS) and ion mobility separation (IMS) stages including differential IMS or FAIMS, as well as IMS and MS stages in various configurations. In particular, "wedge" funnels comprising two planar surfaces positioned at an angle and wedge funnel traps derived therefrom can compress ion beams in one dimension, producing narrow belt-shaped beams and laterally elongated cuboid packets. This beam profile reduces the ion density and thus space-charge effects, mitigating the adverse impact thereof on the resolving power, measurement accuracy, and dynamic range of MS and IMS analyzers, while a greater overlap with coplanar light or particle beams can benefit spectroscopic methods.

47 OTHER INSTRUMENTATION↗

Extraction Simulations and Emittance Measurements of a Holifield Radioactive Ion Beam Facility Electron Beam Plasma Source for Radioactive Ion Beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

Liu, Yuan↗

Ion Production and Transport in Atmospheric Pressure Ion Source Mass Spectrometers (Final Report)

This document is the final report on a project that focused in the general theme of atmospheric-pressure ion production and transport for mass spectrometry. Within that general theme there were two main projects: the fundamental study of the transport of elemental ions through the vacuum interface of an inductively coupled plasma mass spectrometer (ICPMS), and fundamental studies of the ionization mechanisms in ambient desorption/ionization (ADI) sources for molecular mass spectrometry. In both cases the goal was to generate fundamental understanding of key instrumental processes that would lead to the development of instruments that were more sensitive and more consistent in their performance. The emphasis on consistency derives from the need for instruments that have the same sensitivity, regardless of sample type. In the jargon of analytical chemistry, such instruments are said to be free from matrix effects. In the ICPMS work each stage of ion production and of ion transport from the atmospheric pressure to the high-vacuum mass analyzer was studied. Factors controlling ion transport efficiency and consistency were identified at each stage of pressure reduction. In the ADI work the interactions between an electrospray plume and a fluorescent sample on a surface were examined microscopically. A new mechanism for analyte ion production in desorption electrospray ionization (DESI) was proposed. Optical spectroscopy was used to track the production of reactive species in plasmas used as ADI sources. Experiments with mixed-gas plasmas demonstrated that the addition of a small amount of hydrogen to a helium ADI plasma could boost the sensitivity for some analytes by over an order of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Beam Dynamics Studies of a Multi-Ion Linac Injector for the JLEIC Ion Complex

The electron-ion collider (JLEIC) being proposed at JLab requires a new ion accelerator complex which includes a linac capable of delivering any ion beam from hydrogen to lead to the booster. We are currently developing a linac which consists of several ion sources, a normal conducting (NC) front end, up to 5 MeV/u, and a SC section for energies > 5 MeV/u. This design work is focused on the beam dynamics and electrodynamics studies performed to design efficient and cost-effective accelerating structures for both the NC and SC sections of the linac. Currently, we are considering two separate RFQs for the heavy-ion and light-ion beams including polarized beams, and different types of NC accelerating structures downstream of the RFQ. Quarter-wave and half-wave resonators can be effectively used in the SC section.

Ostroumov, P. N.↗

Anode for sodium-ion and potassium-ion batteries

A first method for fabricating an anode for use in sodium-ion and potassium-ion batteries includes mixing a conductive carbon material having a low surface area, a hard carbon material, and a binder material. A carbon-composite material is thus formed and coated on a conductive substrate. A second method for fabricating an anode for use in sodium-ion and potassium-ion batteries mixes a metal-containing material, a hard carbon material, and binder material. A carbon-composite material is thus formed and coated on a conductive substrate. A third method for fabricating an anode for use in sodium-ion and potassium-ion batteries provides a hard carbon material having a pyrolyzed polymer coating that is mixed with a binder material to form a carbon-composite material, which is coated on a conductive substrate. Descriptions of the anodes and batteries formed by the above-described methods are also provided.

25 ENERGY STORAGE↗

Electrically regenerated ion-exchange technology: Leveraging faradaic reactions and assessing the effect of co-ion sorption

Capacitive deionization (CDI) technologies have the potential to become cost-competitive alternatives to reverse osmosis for the treatment of brackish waters. In this study, we describe our findings on the effect of co-ion sorption and faradaic side reactions on our ion exchange resin functionalized desalination electrodes which passively capture salt and reject it upon charging. This system, which we previously reported on and refer to as electrically regenerated ion exchange (ERI), avoids the use of expensive ion exchange membranes in an effort to save costs. Surprisingly, we find that, compared to a reference CDI system, ERI electrodes capture salt most effectively at low applied voltages (0.5 mg/cm 3 at 0.8 V). Both CDI and ERI systems also seem to suffer from co-ion sorption effects which negatively impact salt adsorption. However, Faradaic side reactions at higher voltages (1 V and 1.2 V) which we track via pH measurements, serve as a detriment to CDI but seem to facilitate the functionality of ERI.

42 ENGINEERING↗

The structural influence of aluminium ions on emission characteristics of Sm{sup 3+} ions in lead aluminium silicate glass system

Graphical abstract: The optical absorption and photoluminescence spectra of Sm ions in PbO-Al{sub 2}O{sub 3}-SiO{sub 2} glasses mixed with different concentrations of Al{sub 2}O{sub 3} have been investigated. From these spectra, the emission probabilities and also fluorescence lifetime principal transition viz., {sup 4}G{sub 5/2} {yields} {sup 6}H{sub 7/2} of Sm{sup 3+} ions of has been evaluated. The analysis of results of these studies has indicated that there is a less radiative trapping and enhanced fluorescence lifetime and high quantum efficiency in the glasses mixed with 8.0 mol% of Al{sub 2}O{sub 3}. Highlights: Black-Right-Pointing-Pointer Glasses of the composition (40 - x)PbO-(5 + x)Al{sub 2}O{sub 3}-54SiO{sub 2}:1.0Sm{sub 2}O{sub 3} with x = 5-10 mol% were prepared. Black-Right-Pointing-Pointer Spectroscopic properties (OA, PL and IR) were investigated. Black-Right-Pointing-Pointer Emission probability, lifetime, branching ratio of {sup 4}G{sub 5/2} {yields} {sup 6}H{sub 7/2} transition of Sm{sup 3+} have been evaluated. Black-Right-Pointing-Pointer Analysis of the results indicated that glass mixed with 8.0 mol% exhibits high luminescence efficiency. -- Abstract: Optical absorption and photoluminescence characteristics of Sm{sup 3+} ions in lead silicate glasses mixed with different concentrations of Al{sub 2}O{sub 3} (5-10 mol%) have been investigated. From these studies, the radiative properties viz., spontaneous emission probability A, the total emission probability, the radiative lifetime {tau}{sub R}, the fluorescent branching ratio {beta} of emission transition of {sup 4}G{sub 5/2} {yields} {sup 6}H{sub 7/2} along with other transitions for Sm{sup 3+} have been evaluated and found to be the highest for the glass mixed with 8.0 mol% of Al{sub 2}O{sub 3}.The IR spectral studies have indicated that Al{sup 3+} ions do participate in the glass network with AlO{sub 4} and AlO{sub 6} structural units and further revealed that the concentration of octahedral aluminium ions induce bonding defects in the glass network. Such bonding defects are assumed to be responsible for low phonon losses in these glasses and lead to higher values of radiative parameters for the glass mixed with 8.0 mol% of Al{sub 2}O{sub 3}.

36 MATERIALS SCIENCE↗

Laser ion source for heavy ion inertial fusion

The proposed heavy ion inertial fusion (HIF) scenarios require ampere class low charge state ion beams of heavy species. A laser ion source (LIS) is recognized as one of the promising candidates of ion beam providers, since it can deliver high brightness heavy ion beams to accelerators. A design of LIS for the HIF depends on the accelerator structure and accelerator complex following the source. In this article, we discuss the specifications and design of an appropriate LIS assuming two major types of the accelerators: radio frequency (RF) high quality factor cavity type and non-resonant induction core type. We believe that a properly designed LIS satisfies the requirements of both types, however some issues need to be verified experimentally.

43 PARTICLE ACCELERATORS↗

High-Capacity Aqueous Storage in Vanadate Cathodes Promoted by the Zn-Ion and Proton Intercalation and Conversion–Intercalation of Vanadyl Ions

Aqueous Zn-ion batteries (AZIBs) are promising alternatives to lithium-ion batteries in stationary storage. However, limited storage capacity and cyclic life impede their large-scale implementation. In this study, we report reversible electrochemical insertion of multi-ions into sodium vanadate (NaV 3 O 8 ) cathode materials for AZIBs, achieving a maximum storage capacity of 450 mAh g –1 at 0.05 A g –1 and a capacity retention of 82% after 500 cycles at 0.4 A g –1 . In addition to Zn 2+ and H + insertion, in situ X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) collectively provide explicit evidence on vanadyl ions (VO 2+ ) conversion–intercalation at the NaV 3 O 8 cathode, showing the deintercalation of VO 2+ from NaV 3 O 8 and the consequent conversion of VO 2+ into V 2 O 5 on charging, and vice versa on discharging. Our study is the first to report on the cation conversion–intercalation mechanism in AZIBs. This reversible multi-ion storage mechanism provides a design principle for developing high-capacity aqueous electrode materials by engaging both the intercalation and conversion of charge carriers.

25 ENERGY STORAGE↗