Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Impact of moderate pump–Stokes chirp on femtosecond coherent anti-Stokes Raman scattering spectra

The effects of inducing moderate chirp in the pump and Stokes beams in chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering (CARS) spectroscopy are discussed. This is an important issue for measurements in high-pressure systems where the CARS beams must be transmitted through glass of significant thickness to reach the probe volume of interest. The effects were investigated both experimentally, by inserting disks of SF-11 glass into the pump and Stokes beam paths, and theoretically, by incorporating pulse chirp into our time-dependent density matrix (TDDM) simulations. Experimentally, we found that inducing moderate pump and Stokes chirp produced significant spectral narrowing of the nonresonant four-wave mixing contribution to the CARS signal, and this allowed us to control the resonant excitation bandwidth to eliminate interferences from neighboring species. The temperature measurement accuracy and precision were essentially unchanged with respect to the unchirped pump and Stokes case. The effect of moderate pump and Stokes chirp on the narrowing of the Raman excitation efficiency envelope was investigated by solving the full set of TDDM through direct numerical integration. The numerical efficiency of the solutions was enhanced dramatically by developing a parallel version of the TDDM code. The calculated Raman excitation efficiency profile was incorporated in our phenomenological spectral fitting codes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Trend Shifts Induced by Method of Concentration for Trace Metals in Seawater: Automated Online Preconcentration vs Borohydride Reductive Coprecipitation of Nearshore Seawater Samples for Analysis of Ni, Cu, Zn, Cd, and Pb via ICP-MS

This research compares performance, reproducibility, and detection limits of ambient seawater analysis for trace metals using both borohydride reductive co-precipitation and an automated chelation column (seaFAST™ 2) co-preconcentration for matrix interferent elimination on total and dissolved grab samples in nearshore to marine waters, over a broad concentration range, prior to ICP-MS injection. A move to an online preconcentration method both minimizes sample preparation, and eliminates correction errors when accounting for trace impurities in precipitated samples, induced via reagents. The reproducability of the online preconcentration method described, coupled with low blanks and method detection limits (MDLs), demonstrates an effective move to an automated procedure using ethylenediaminetriacetic and iminodiacetate acid chelation exchange resin and multi-analyte determination via ICP-MS for total and dissolved Ni, Cu, Zn, Cd, and Pb in marine water samples. Average CASS-5 recoveries using the online preconcentration method (n=9) were 109±7%, 104±5%, 103±7%, 101±3%, and 86±8% respectively. The MDLs obtained from the automated method for Ni, Cu, Zn, Cd and Pb were 3.3, 1.8, 13.5, 4, and 10 times lower, respectively, than for the Borohydride method. There were statistically significant differences between the methods for CASS-5 recoveries of Ni, Cu, Zn (p < 0.0001), and Pb (p = 0.0024). Comparison of methods gave high concordance (rC = 0.90) between methods for total and dissolved Ni, Cu, Zn, and Pb, and total Cd.

seaFAST, borohydride, seawater, Ethylenediaminetet↗

Surface analysis insight note: X‐ray photoelectron spectroscopy analysis of battery electrodes—Challenges with nickel–manganese–cobalt and Li examples using an Al Kα x‐ray source

X‐ray photoelectron spectroscopy (XPS) has become a highly important tool for the analysis of battery materials and components. However, both anecdotal and detailed analysis of selected parts of the literature indicate that many reports of XPS on battery electrodes have significant analysis or data flaws. In this paper, we highlight several of the common challenges that analysts face when using XPS for battery materials, pointing to recent literature that addresses many of the critical issues associated with sample preparation as well as data collection and analysis. A common error for battery materials (and other materials) involves ignoring peak overlaps and interferences. Specifically, when a “minor” peak associated with a component in relatively high concentration overlaps or contributes to the primary peak (or one recommended for quantitative analysis) from a different element in the material. Overlap issues apply to many battery electrodes composed of many elements with complex photoelectron peak structures, as well as those involving peaks with seemingly simpler spectral envelopes such as Li and F. Examples of issues associated with battery systems are highlighted by a discussion of challenges associated with XPS analysis of Li and nickel–manganese–cobalt (NMC) electrodes in battery systems. Lithium analysis has challenges associated with the preparation and an often‐unrecognized peak overlap with F. In our laboratory and in the literature, NMC electrodes are often examined and new XPS users do not always recognize interference of the Auger signal from F KLL (in or on the electrode) with Ni 2p photoelectron spectrum when generated with Al Kα X‐rays. The use of simulated spectra involving both F and NiO demonstrates the extent of F Auger contributions to the Ni 2p signal strength as a function of the F/Ni atom ratio in the material and suggests spectra information that can be used to identify how significant effects will be on the resultant spectra. Our analysis demonstrates that in many cases overlap issues are significant for real electrode materials.

25 ENERGY STORAGE↗

Ultrabroadband Spacetime Nanoscopy of Terahertz Polaritons in a van der Waals Cavity

Guiding, storing, and processing light at the nanoscale hinges on understanding how polaritons — hybrid quasiparticles of light and matter — propagate and interfere in both space and time. This work introduces a synchrotron-based technique, SYnchrotron SpaceTimE Mapping (SYSTEM), which captures real-time evolution of polariton wave packets with ∼10 nm spatial and sub-100 fs temporal resolution across an ultrabroadband 5–50 THz range. Here, SYSTEM directly visualizes the creation, interference, and decay of multiple high-quality Fabry-Pérot phonon polariton cavity modes in an α-MoO 3 microcavity. These real-space, real-time observations reveal wave-packet dynamics and cavity resonances with record-high quality factors (Q ≈ 100) in the single-digit terahertz regime near 9 THz. SYSTEM thus offers a powerful and broadly applicable platform for probing and engineering ultraslow, deeply subwavelength polaritons, opening new avenues for tailoring light–matter interactions and advancing next-generation THz nanophotonic technologies.

36 MATERIALS SCIENCE↗

The Bactrian effect: multiple resonances and light Dirac dark matter

The possibility of light dark matter (DM) annihilating through a dark photon (DP) which kinetically mixes (KM) with the Standard Model (SM) hypercharge field is a very attractive scenario. For DM in the interesting mass range below ~1 GeV, it is well known that bounds from the CMB provide a very strong model building constraint forcing the DM annihilation cross section to be roughly 3 orders of magnitude below that needed to reproduce the observed relic density. Under most circumstances this removes the possibility of an s-wave annihilation process for DM in this mass range as would be the case, e.g., if the DM were a Dirac fermion. In an extra-dimensional setup explored previously, it was found that the s-channel exchange of multiple gauge bosons could simultaneously encompass a suppressed annihilation cross section during the CMB era while also producing a sufficiently large annihilation rate during freeze-out to recover the DM relic density. In this paper, we analyze more globally the necessary requirements for this mechanism to work successfully and then realize them within the context of a simple model with two ‘dark’ gauge bosons having masses of a similar magnitude and whose contributions to the annihilation amplitude destructively interfere. We show that if the DM mass threshold lies appropriately in the saddle region of this destructive interference between the two resonance humps it then becomes possible to satisfy these requirements simultaneously provided several ancillary conditions are met. The multiple constraints on the parameter space of this setup are then explored in detail to identify the phenomenologically successful regions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for W' $\to $ tb decays in the lepton + jets final state in pp collisions at $\sqrt{s}$ = 8 TeV

Results are presented from a search for the production of a heavy gauge boson W' decaying into a top and a bottom quark, using a data set collected by the CMS experiment at sqrt(s) = 8 TeV and corresponding to an integrated luminosity of 19.5 inverse femtobarns. Various models of W'-boson production are studied by allowing for an arbitrary combination of left- and right-handed couplings. The analysis is based on the detection of events with a lepton (e, mu), jets, and missing transverse energy in the final state. No evidence for W'-boson production is found and 95% confidence level upper limits on the production cross section times branching fraction are obtained. For W' bosons with purely right-handed couplings, and for those with left-handed couplings assuming no interference effects, the observed 95% confidence level limit is M(W') > 2.05 TeV. For W' bosons with purely left-handed couplings, including interference effects, the observed 95% confidence level limit is M(W') > 1.84 TeV. The results presented in this paper are the most stringent limits published to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the CP structure of the top quark Yukawa at the future muon collider

We study the top-Higgs coupling with a CP violating phase ξ at a future multi-TeV muon collider. We focus on processes that are directly sensitive to the top quark Yukawa coupling: $t$$\overline{t}$$h$, $tbhμν$, and $t$$\overline{t}$$h$$v$$\overline{v}$ with $h$ → $b$$\overline{b}$ and semileptonic top decays. At different energies, different processes dominate the cross section, providing complementary information. At and above an energy of $\mathcal{O}$(10) TeV, vector boson fusion processes dominate. As we show, in the Standard Model there is destructive interference in the vector boson fusion processes $t$$\overline{t}$$h$$v$$\overline{v}$ and $tbhμν$ between the top quark Yukawa and Higgs-gauge boson couplings. A CP-violating phase changes this interference, and the cross section measurement is very sensitive to the size of the CP-violating angle. Although we find that the cross sections are measured to $\mathcal{O}$(50%) statistical uncertainty at 1σ, a 10 and 30 TeV muon collider can bound the CP-violating angle |ξ| ≲ 9.0° and |ξ| ≲ 5.4°, respectively. However, cross section measurements are insensitive to the sign of the CP-violating angle. To determine that the coupling is truly CP violating, observables sensitive to CP-violation must be measured. We find in the $t$$\overline{t}$$h$ process the azimuthal angle between the $t$ + $\overline{t}$ plane and the initial state muon+Higgs plane shows good discrimination for ξ = ±0.1π.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing CP violation in e + e - production of the Higgs boson and toponia

We study the CP violation in the Higgs boson and toponia production process at the ILC where the toponia are produced near the threshold. With the approximation that the production vertex of the Higgs boson and toponia is contact, and neglecting the P-wave toponia, we analytically calculated the density matrix for the production and decay of the toponia. Under these assumptions, the production spectrum of the toponia is solely determined by the spin quantum number, therefore the toponia can be either singlet or triplet. We find that the production rate of the singlet toponium is highly suppressed, and behaves just like the production of a P-wave toponia. In the case of the triplet toponium, three completely independent CP observables, namely azimuthal angles of lepton and antilepton in the toponium rest-frame as well as their sum, are predicted based on our analytical results, and checked by using the tree-level event generator. The non-trivial correlations come from the longitudinal-transverse interferences for the azimuthal angles of leptons, and the transverse-transverse interference for their sum. These three observables are well defined at the ILC, where the rest frame of the toponium can be reconstructed directly. Furthermore, the QCD-strong corrections, which are important near the threshold region, are also studied with the approximation of spin-independent QCD-Coulomb potential. While the total cross section is enhanced, the spin correlations predicted in this paper are not affected.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin correlations and new physics in τ -lepton decays at the LHC

We use spin correlations to constrain anomalous τ -lepton couplings at the LHC including its anomalous magnetic moment, electric dipole moment and weak dipole moments. Single spin correlations are ideal to probe interference terms between the SM and new dipole-type couplings as they are not suppressed by the τ -lepton mass. Double spin asymmetries give rise to T -odd correlations useful to probe CP violation purely within the new physics amplitudes, as their appearance from interference with the SM is suppressed by m τ . We compare our constraints to those obtained earlier on the basis of deviations from the Drell-Yan cross-section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Review of Global Radioxenon Background Research and Issues

Among the most important problems for the world-wide nuclear explosion monitoring is the interference of naturally occurring and man-made radionuclides. The International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) frequently detects these interferences using sensitive radionuclide measurement equipment. We commonly refer to the presence of radionuclides that are relevant to the CTBT but do not originate from a nuclear explosion as “background”. Backgrounds are highest near the sources but are known to have regional and global effects on the IMS. This review paper summarizes much of the relevant work in the area of background and discusses issues of interest for nuclear explosion detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Acylation as a successful derivatization strategy for the analysis of pinacolyl alcohol in a glycerol-rich matrix by GC-MS: application during an OPCW Proficiency Test

A derivatization protocol based on the acylation of pinacolyl alcohol (PA), an important marker for the nerve agent soman, is presented. The procedure provides a convenient means of detecting, by gas chromatography-mass spectrometry (GC-MS), PA when present at a low concentration in a complex glycerol/alcohol-rich matrix. While there are only two reports describing the specific analysis of PA in matrices at low concentrations, the protocol described herein represents the first of its kind in the analysis of PA in a highly reactive matrix. Two alternative paths for the protocol’s execution are presented. The first involves the direct derivatization of the PA with either acetyl or benzoyl chloride; both reactions yield ester products with significantly different retention times than those of the interferences of the reactive glycerol-rich matrix and in areas of the GC-chromatogram featuring lower levels of matrix interferences. A second procedure involved an initial diethyl ether/aqueous extraction of the matrix; while the extraction was found to substantially remove many of the hydrophilic matrix components and improve the overall derivatization, it also led to some loss of PA available for the derivatization. Both protocols were applied to the successful derivatization and analysis of PA by GC-MS when present at a 5 μg.mL -1 concentration in a glycerol-rich matrix sample administered during the 48th Proficiency Test administered by the Organisation for the Prohibition of Chemical Weapons (OPCW).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and implementation of dynamic I/O control scheme for large scale distributed file systems

In this paper, we have analyzed the input/output (I/O) activities of Cori, which is a high-performance computing system at the National Energy Research Scientific Computing Center at Lawrence Berkeley National Laboratory. Our analysis results indicate that most users do not adjust storage configurations but rather use the default settings. In addition, owing to the interference from many applications running simultaneously, the performance varies based on the system status. To configure file systems autonomously in complex environments, we developed DCA-IO, a dynamic distributed file system configuration adjustment algorithm that utilizes the system log information to adjust storage configurations automatically. Our scheme aims to improve the application performance and avoid interference from other applications without user intervention. Moreover, DCA-IO uses the existing system logs and does not require code modifications, an additional library, or user intervention. To demonstrate the effectiveness of DCA-IO, we performed experiments using I/O kernels of real applications in both an isolated small-sized Lustre environment and Cori. Our experimental results shows that our scheme can improve the performance of HPC applications by up to 263% with the default Lustre configuration.

97 MATHEMATICS AND COMPUTING↗

Rapid determination of 210 Po in water samples

A new rapid method for the determination of 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that can be used for emergency response or routine water analyses. If a radiological dispersive device (RDD) event or a radiological attack associated with drinking water supplies occurs, there will be an urgent need for rapid analyses of water samples, including drinking water, ground water and other water effluents. Current analytical methods for the assay of 210 Po in water samples have typically involved spontaneous auto-deposition of 210 Po onto silver or other metal disks followed by counting by alpha spectrometry. The auto-deposition times range from 90 minutes to 24 hours or more, at times with yields that may be less than desirable. If sample interferences are present, decreased yields and degraded alpha spectrums can occur due to unpredictable thickening in the deposited layer. Separation methods have focused on the use of Sr Resin, often in combination with 210 Pb analysis. A new rapid method for 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that utilizes a rapid calcium phosphate co-precipitation method, separation using DGA Resin (N,N,N,N-tetraoctyldiglycolamide extractant-coated resin, Eichrom Technologies or Triskem-International), followed by rapid microprecipitation of 210 Po using bismuth phosphate for counting by alpha spectrometry. This new method can be performed quickly with excellent removal of interferences, high chemical yields and very good alpha peak resolution, eliminating any potential problems with the alpha source preparation for emergency or routine samples. A rapid sequential separation method to separate 210 Po and actinide isotopes was also developed. This new approach, rapid separation with DGA Resin plus microprecipitation for alpha source preparation, is a significant advance in radiochemistry for the rapid determination of 210 Po.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison of irradiated foil measurements with activation calculations and HPGe simulations

Theoretical activation calculations for Fe, Ni, and stainless steel foils were compared against irradiated foil measurements from a critical assembly. Calculated/experiment values spanning 0.62-1.31 showed that the restricted approach used here is insufficient for experiment planning, with the collapsed cross-section being the primary source of error. The effect of decay time on gamma-ray spectroscopy measurement reliability was investigated using a Monte Carlo HPGe detector model. Simulations showed no correlation with decay time, absent interferences. Specific interferences for Fe-59 (Ni) and Co-60 (stainless steel) activation product ratios suggested optimal measurement windows having respective decay times of 9-11 days and 4-7 days.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anticoincidence analysis for radioxenon detection

A number of beta-gamma coincidence detectors have been deployed for monitoring nuclear explosions. When 133Xe is present in a sample it causes interference in the calculation of the metastable isotopes. Therefore, an alternative method for activity quantification is to analyze the anticoincidence spectrum of the plastic detector to decrease interference from 133Xe. Simulated and experimental measurements were tested. The results show that the anticoincidence analysis produces more accurate results when quantifying the activity of 131mXe but is sometimes limited by the background increasing the minimum detectable activity.

Sivels, Ciara B.↗

The LLNL rabbit: determination of trace element levels in polyethylene

Rabbit facilities are systems that pneumatically transport a sample carrier (known as a rabbit) to and from a radiation source. However, trace impurities in the polyethylene (PE) rabbit may interfere with measurements of short-lived isotopes. Activated impurities with short half-lives as 28 Al interfere with the fission product γ-ray, therefore the rabbit cannot be measured immediately. Neutron activation analysis was performed on various PE samples obtained from different manufacturers and the highest quality PE was used to fabricate a high-purity PE rabbit. Here, the impurities identified in the PE study were 27 Al, 48 Ca, 37 Cl, 50 Cr, 65 Cu, 127 I, 26 Mg, 55 Mn, and 30 Si.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

The Effect of Annealing Time on Microstructure and AC Corrosion Behavior of X80 Steel in Simulated Solution of Alkaline Soil

The alternating current (AC) corrosion behavior of X80 steels annealed for different times was investigated in an alkaline soil simulation solution by electrochemical measurement, immersion test and surface analysis technology. The results show that with or without AC interference, the steels annealed for various times have different corrosion resistance. The anticorrosion resistance of steel improves with an increase in annealing time. AC interference results in the evolution of the main cathodic reaction, and facilitates the corrosion of the steels. The steel annealed for 20 min presents a more severe corrosion degree with distinct pits. The corrosion behavior of the steels annealed for different times with AC application is closely related to the microstructure. A decrease in pearlite reduces the number of galvanic corrosion cells, decreasing the corrosion rate of steel. And the grain increase is beneficial for improving the corrosion resistance of the annealed steel.

36 MATERIALS SCIENCE↗