Multiscale investigation of thermomechanical and compositional developments in Ni alloy 718 under laser processing

Laser processing has been widely employed in various applications due to its exceptional spatial resolution. However, the rapid temperature gradients generated in localized areas present significant challenges for experimental characterization using conventional instruments. To characterize Ni alloy 718 during laser processing, we employed in-situ synchrotron X-ray diffraction with a high-speed detector, a method particularly well-suited for probing processes with high temporal and spatial resolution. Through a series of in-situ experiments, we investigated the local variations in the evolution of microstructures and thermomechanical behaviors within a keyhole mode melt pool. The in situ macroscopic thermomechanical behaviors were quantified using an empirical model derived from diffraction patterns, with experimental results showing reasonable agreement with finite element analysis. Various laser parameters were tested to assess their influences on the residual strains in the melt pools. The results revealed that the residual strain in the keyhole mode melt pool is relatively insensitive to variations in the parameters and is smaller than that in the melt pool created under conduction mode laser scanning. Additionally, we analyzed the shapes of individual diffraction spots, providing insights into the plastic behaviors and compositional developments in the resolidified alloy. The analysis confirmed that compositional variations in a dendritic microstructure manifest as asymmetric broadening of the diffraction spots.

Ni alloy 718↗

Evaluation of light collection from highly scattering media using wavelength-shifting fibers

Opaque scintillators are designed to have a short scattering length such that scintillation photons are probabilistically confined to a small region of space about their origin. The benefit of this feature is that information on the interaction event topology can be recorded with greater fidelity than in traditional highly transparent media with sensors at large distances from the light production region. Opaque scintillator detectors rely on wavelength-shifting fibers to extract the scintillation light; however, the efficiency of light collection has not yet been directly measured in experiment. We measured the efficiency of light collection as a function of the optical parameters of an opaque liquid and the distance from the origin of the light to the fiber. We use the experimental data to validate a Monte Carlo model of light transport and collection and discuss a simple diffusion model that reproduces the results of Monte Carlo simulation with high fidelity. Furthermore, this combination of validated models has the potential for use in predictions of performance in various designs of future opaque scintillator detectors such as LiquidO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Device response principles and the impact on energy resolution of epitaxial quantum dot scintillators with monolithic photodetector integration

Abstract Epitaxial quantum dot (QD) scintillator crystals with picosecond-scale timing and high light yield have been created for medical imaging, high energy physics and national security applications. Monolithic photodetector (PD) integration enables the sensing of photons generated within the waveguiding crystal and allows a wide range of scintillator-photodetector coupling geometries. Until recently, these doubly novel devices have suffered from complex, high variance responses to monoenergetic sources which significantly reduces their precision and accuracy. The principles governing the overall device response have now been discerned and embodied by an expression derived within a geometrical optics framework which considers optical properties, surface roughness and photodetector coupling geometry. Response variation due to these factors was sufficiently reduced to obtain material-related energy resolution values of 2.4% with alpha particles. These findings place energy resolution alongside luminescence timescale, photon yield, and radiation hardness as outstanding properties of these engineered materials.

36 MATERIALS SCIENCE↗

Angular scattering of protons through ultrathin graphene foils: Application for time-of-flight instrumentation

Space plasma instruments often rely on ultrathin carbon foils for incident ion detection, time-of-flight (TOF) mass spectrometry, and ionization of energetic neutral atoms. Angular scattering and energy loss of ions or neutral atoms in the foil can degrade instrument performance, including sensitivity and mass resolution; thus, there is an ongoing effort to manufacture thinner foils. Using new 3-layer graphene foils manufactured at the Los Alamos National Laboratory, we demonstrate that these are the thinnest foils reported to date and discuss future testing required for application in space instrumentation. We characterize the angular scattering distribution for 3–30 keV protons through the foils, which is used as a proxy for the foil thickness. We show that these foils are ~2.5–4.5 times thinner than the state-of-the-art carbon foils and ~1.6 times thinner than other graphene foils described in the literature. We find that the inverse relationship between angular scattering and energy no longer holds, reaffirming that this may indicate a new domain of beam–foil interactions for ultrathin (few-layer) graphene foils.

47 OTHER INSTRUMENTATION↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

Cosmic Muon Veto for the mini-ICAL detector at IICHEP, Madurai

A 51-kiloton magnetised Iron Calorimeter (ICAL) detector, using Resistive Plate Chambers (RPCs) as active detector elements, aims to study atmospheric neutrinos. A prototype - 1/600 of the weight of ICAL, called mini-ICAL was installed in the INO transit campus at Madurai. A modest proof-of-principle cosmic muon veto detector of about 1 m × 1 m × 0.3 m dimensions was setup a few years ago, using scintillator paddles. The measured cosmic muon veto efficiency of 99.98% and simulation studies of muon-induced background events in the ICAL detector surrounded by an efficient veto detector were promising. This led to the idea of constructing a bigger cosmic muon veto around the mini-ICAL detector. Details of the design and construction of the detector including the electronics, trigger and DAQ systems planned will be briefly presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory

FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operation of a robotic telescope for such a purpose and their implementation within the FRAM system.

Optics↗

First results from a multiplexed and massive instrument with sub-electron noise Skipper-CCDs

Here, we present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, 1.35 Mpix sensors, from a new foundry, are glued into a Multi-Chip Module (MCM) printed circuit board on a ceramic substrate which has 16 sensors each. The instrument, that can hold up-to 16 MCMs, a total of 256 Skipper-CCD sensors (called a Super-Module with ≈ 130 grams of active mass and 346 Mpix), is part of the R&D effort of the OSCURA experiment which will have ≈ 94 super-modules. Experimental results with 10 MCMs and 160 Skipper-CCDs sensors are presented in this paper. This is already the largest ever built instrument with single electron sensitivity CCDs using nondestructive readout, both, in terms of active mass and number of channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a strip-shaped X-ray mapping system for 9-cell superconducting cavities

Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, in this study, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excitation of Bloch Surface Waves in Zero-Admittance Multilayers for High-Sensitivity Sensor Applications

The growing need for classical as well as quantum optical sensing places increasingly stringent requirements upon the desired characteristics of the engendered fields. Specifically, achieving superior field enhancement plays a critical role in applications ranging from chem-bio sensing, Raman and infrared spectroscopies to ion trapping and qubit control in emerging quantum-information science. Due to their low optical losses and ability to exhibit resonant field enhancements, all dielectric multilayers are emerging as an optical material system not only useful to classical photonics and sensing but also of potential to be integrated with quantum materials and quantum sensing. The recently introduced concept of zero-admittance layers [1] within dielectric multilayer materials, enables the creation and control of resonant fields orders of magnitude larger than the exciting field. Here, invoking the zero-admittance concept, we design, fabricate, and characterize an all-dielectric nonabsorbing stack and demonstrate the engendered huge field enhancement. Describing the fields in terms of Bloch surface waves, we connect the surface field to the semiperiodicity in the dielectric domains of the stack. As a specific application of the resonant field, we propose and demonstrate refractive-index sensing for the detection of trace amounts of an analyte. The results include a quantification of the sensitivity of the device with respect to the profile of the exciting field. The experimental results are shown to be in good agreement with theoretical calculations.

47 OTHER INSTRUMENTATION↗

Uniform field in microwave cavities through the use of effective magnetic walls

Wire medium (WM) resonators have emerged as a promising realization for plasma haloscopes—devices designed to detect axions, a potential component of dark matter. Key factors influencing the detection probability include cavity volume, resonance quality factor, and form factor. While the form factor has been explored for resonant frequency tuning, its optimization for axion detection remains unexplored. Here, in this work, we present an approach to significantly enhancing the form factor of WM plasma haloscopes. By shifting the metal walls of the resonator by a quarter wavelength, we effectively convert an electric wall boundary condition into a magnetic wall one, allowing for an almost uniform mode. Theoretical analysis and numerical simulations confirm that this modification improves the electric field profile and boosts the form factor, while also slightly enhancing the quality factor. We validate these findings through experimental results from two prototype resonators: one with a standard geometry and another with a quarter-wave air gap between the WM and the walls. Additionally, our method provides a simple way to control the field profile within WM cavities, which can be explored for further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Timing Properties for an Event Driven with Access and Reset Decoder Readout Architecture for a Pixel Array

The large number of data generating sources (data channels) on a single chip requires appropriate techniques to manage a readout from these channels. One of the main methods is sharing a medium of transmission, which requires arbitration to avoid collisions or deadlocks. Existing solutions face several problems such as a dead time, unintended prioritization or metastability. That is why we decided to create a new readout architecture named EDWARD i.e., Event Driven with Access and Reset Decoder. The EDWARD architecture gets rid of the earlier mentioned problems and mitigates the other ones. However, due to the use of logic circuits outside a standard cell library, which are hard to characterize, we were challenged to perform an additional transient analysis to validate the architecture. Here we show a methodology and the results of the simulations. Based on the results obtained we can confirm the functional correctness of the system and plan the optimization of operating conditions in order to achieve better performance. Our goal is to use the EDWARD architecture in the future radiation detectors to be built at Brookhaven National Laboratory.

47 OTHER INSTRUMENTATION↗

Demonstrating Safeguards Applications of DRiFT Gas Detector Capabilities [Slides]

DRiFT, a Detector Response Function Toolkit, post-processes MCNP output to model detector response. Three primary components: scintillator (focus of FY 21 TED work), gas detectors (focus of this FY), and semiconductor detectors. Capability to model scintillator detectors has previously been demonstrated.

47 OTHER INSTRUMENTATION↗

FNCL Enhancements Implementation (FY25 Annual Report)

The FNCL investigations team at Lawrence Livermore National Laboratory (LLNL) has completed research and development of hardware, signal processing, and analysis tools to enhance the measurement capabilities of both the current CAEN SyS VeryFuel Fast Neutron Collar (FNCL) instrument and a next-generation FNCL prototype. The team successfully built and commissioned the LLNL Demonstrator System: a fully integrated, three-panel detector system featuring higher segmentation, plastic scintillators (EJ-276D), Silicon Photomultipliers (SiPMs), no high-voltage requirement, a reduced electronic footprint, and the LLNL-developed Gaussian Mixture Model Pulse Shape Discrimination (GMM-PSD) signal processing. An extensive experimental campaign was conducted at LLNL’s Inherently Safe Subcritical Assembly (ISSA) facility using both the baseline FNCL and the LLNL Demonstrator. The campaign results validated system performance, calibration stability, and the effectiveness of advanced signal processing and analysis algorithms in a relevant environment.

and physical protection↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗