Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Full Simulation of CMS for Run-3 and Phase-2

In this contribution we report the status of the CMS Geant4 simulation and the prospects for Run-3 and Phase-2. Firstly, we report about our experience during the start of Run-3 with Geant4 10.7.2, the common software package DD4hep for geometry description, and VecGeom runtime geometry library. In addition, FTFP_BERT_EMM Physics List and CMS configuration for tracking in magnetic field have been utilized. For the first time, for the Grid mass production of Monte-Carlo, this combination of components is used. Further simulation improvements are under development targeting Run-3 such as the switch to the new Geant4 11.1 in production, that provides several features important for the optimization of simulation, for example the new transportation process with built-in multiple scattering, neutron general process, custom tracking manager, G4HepEm sub-library, and others. We will present evaluation of various options, validation results, and the final choice of simulation configuration for 2023 production and beyond. The performance of the CMS full simulation for Run-2 and Run-3 will also be discussed. CMS development plan for the Phase-2 Geant4 based simulation is very ambitious, and it includes a new geometry description, physics, and simulation configurations. The progress on new detector descriptions and full simulation will be presented as well as the R&D in progress to reduce compute capacity needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gravitational waves and galaxies cross-correlations: a forecast on GW biases for future detectors

ABSTRACT Gravitational waves (GWs) have rapidly become important cosmological probes since their first detection in 2015. As the number of detected events continues to rise, upcoming instruments like Einstein Telescope (ET) and Cosmic Explorer (CE) will observe millions of compact binary mergers. These detections, coupled with galaxy surveys by instruments such as the Dark Spectroscopic Energy Instrument (DESI), Euclid, and the Vera Rubin Observatory, will provide unique information on the large-scale structure of the universe by cross-correlating GWs with the distribution of galaxies hosting them. In this paper, we focus on how cross-correlations constrain the clustering bias of GWs emitted by the coalescence of binary black holes (BBHs). This parameter links BBHs to the underlying dark matter distribution, hence informing us how they populate galaxies. Using a multitracer approach, we forecast the precision of these measurements under different survey combinations. Our results indicate that current GW detectors will have limited precision, with measurement errors as high as $\displaystyle \sim 50~{{\ \rm per\ cent}}$. However, third-generation detectors like ET, when cross-correlated with Legacy Survey of Space and Time (LSST) data, can improve clustering bias measurements to within 2.5 per cent. Furthermore, we demonstrate that these cross-correlations can enable a per cent-level measurement of the magnification lensing effect on GWs. Despite this, there is a degeneracy between magnification and evolution biases, which hinders the precision of both. This degeneracy is most effectively addressed by assuming knowledge of one bias or targeting an optimal redshift range of $\displaystyle 1 \lt z \lt 2.5$. Our analysis opens new avenues for studying the distribution of BBHs and testing the nature of gravity through large-scale structure.

Zazzera, Stefano (ORCID:0000000158979221)↗

Zero-Power Wireless Infrared Digitizing Sensors for Large Scale Energy-Smart Farm

This project, funded by ARPA-E and led by Northeastern University, developed zeropower infrared digitizing sensors to optimize irrigation and enhance crop yields. Traditional water stress detection methods are costly and require frequent maintenance, limiting their effectiveness. Our research identified shortwave infrared (SWIR) transmittance as the most reliable indicator of plant water stress and developed plasmonically enhanced micromechanical photoswitches (PMPs) that operate with minimal power. The sensors offer low-cost, large-scale deployment, auto-calibration across different crops, and a 10-year battery life, significantly reducing maintenance costs. The system achieved 4x greater accuracy than conventional soil moisture sensors while ensuring economic feasibility. By enabling precision irrigation, this technology conserves water, enhances crop productivity, and lowers operational costs, making it a scalable solution for sustainable agriculture and global food security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Phase Space Reconstruction from Accelerator Beam Measurements Using Neural Networks and Differentiable Simulations

Characterizing the phase space distribution of particle beams in accelerators is a central part of accelerator understanding and performance optimization. However, conventional reconstruction-based techniques either use simplifying assumptions or require specialized diagnostics to infer high-dimensional (> $2D$) beam properties. In this Letter, we introduce a general-purpose algorithm that combines neural networks with differentiable particle tracking to efficiently reconstruct high-dimensional phase space distributions without using specialized beam diagnostics or beam manipulations. Furthermore, we demonstrate that our algorithm accurately reconstructs detailed 4D phase space distributions with corresponding confidence intervals in both simulation and experiment using a single focusing quadrupole and diagnostic screen. This technique allows for the measurement of multiple correlated phase spaces simultaneously, which will enable simplified 6D phase space distribution reconstructions in the future.

47 OTHER INSTRUMENTATION↗

Linker-Free Magnetite-Decorated Gold Nanoparticles (Fe3O4-Au): Synthesis, Characterization, and Application for Electrochemical Detection of Arsenic (III)

Linker-free magnetite nanoparticles (Fe3O4NPs)-decorated gold nanoparticles (AuNPs) were grown using a new protocol that can be used as a new platform for synthesis of other intact metal–metal oxide nanocomposites without the need for linkers. This minimizes the distance between the metal and metal oxide nanoparticles and ensures the optimum combined effects between the two material interfaces. X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy confirmed the successful synthesis of the Fe3O4-Au nanocomposite, without any change in the magnetite phase. Characterization, using transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy, revealed the composite to consist of AuNPs of 70 ± 10 nm diameter decorated with tiny 10 ± 3 nm diameter Fe3O4NPs in Au:Fe mass ratio of 5:1. The prepared Fe3O4-Au nanocomposite was embedded in ionic liquid (IL) and applied for the modification of glassy carbon electrode (GCE) for the electrochemical detection of As(III) in water. By combining the excellent catalytic properties of the AuNPs with the high adsorption capacity of the tiny Fe3O4NPs towards As(III), as well as the good conductivity of IL, the Fe3O4-Au-IL nanocomposite showed excellent performance in the square wave anodic stripping voltammetry detection of As(III). Under the optimized conditions, a linear range of 1 to 100 μg/L was achieved with a detection limit of 0.22 μg/L (S/N = 3), and no interference from 100-fold higher concentrations of a wide variety of cations and anions found in water. A very low residual standard deviation of 1.16% confirmed the high precision/reproducibility of As(III) analysis and the reliability of the Fe3O4-Au-IL sensing interface. Finally, this proposed sensing interface was successfully applied to analyzing synthetic river and wastewater samples with a 95–101% recovery, demonstrating excellent accuracy, even in complex synthetic river and wastewater samples containing high concentrations of humic acid without any sample pretreatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation, analysis, and application of coated glass targets for the Wendelstein 7-X laser blow-off system

Coated glass targets are a key component of the Wendelstein 7-X laser blow-off system that is used for impurity transport studies. The preparation and analysis of these glass targets as well as their performance is examined in this paper. The glass targets have a high laser damage threshold and are coated via physical vapor deposition with μm thick films. In addition, nm-thin layers of Ti are used as an interface layer for improved ablation efficiency and reduced coating stress. Hence, the metallic or ceramic coating has a lateral homogeneity within 2% and contaminants less than 5%, being optimal for laser ablation processing. With this method, a short (few ms) and well defined pulse of impurities with about 1017 particles can be injected close to the last closed flux surface of Wendelstein 7-X. In particular, a significant amount of atoms with a velocity of about 1 km/s enters the plasma within 1 ms. The atoms are followed by a negligible concentration of slower clusters and macro-particles. This qualifies the use of the targets and applied laser settings for impurity transport studies with the laser blow-off system in Wendelstein 7-X.

47 OTHER INSTRUMENTATION↗

First test results of the trans-impedance amplifier stage of the ultra-fast HPSoC ASIC

Abstract We present the first results from the HPSoC ASIC designed for readout of Ultra-fast Silicon Detectors. The 4-channel ASIC manufactured in 65 nm CMOS by TSMC has been optimized for 50 μm thick AC-LGAD. The evaluation of the analog front end with β-particles impinging on 3 × 3 AC-LGAD arrays (500 μm pitch, 200 × 200 μm 2 metal) confirms a fast output rise time of 600 ps and good timing performance with a jitter of 45 ps. Further calibration experiments and TCT laser studies indicate some gain limitations that are being investigated and are driving the design of the second-generation pre-amplification stages to reach a jitter of 15 ps.

Instruments & Instrumentation↗

A new open‐path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections

Abstract Low‐power, open‐path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open‐path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser‐based, open‐path sensors with the needed sensitivity for trace gases like methane (CH 4 ) and nitrous oxide (N 2 O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N 2 O fluxes. Consequently, measuring background fluxes with laser‐based, open‐path sensors is extremely challenging, particularly for N 2 O and gases with similar high‐precision requirements. We demonstrate a new laser‐based, open‐path N 2 O sensor and a general approach applicable to other gases that minimizes temperature‐related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open‐path N 2 O sensor was tested at a corn ( Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature‐related corrections were 6% of density corrections, reducing EC random errors by 20‐fold compared to previously examined lines. Measured open‐path N 2 O EC fluxes showed excellent agreement with those made with static chambers ( m = 1.0 ± 0.3; r 2 = .96). More generally, we identified absorption lines for CO 2 and CH 4 flux measurements that can reduce the temperature‐related corrections by 10–100 times compared to existing open‐path sensors. The proposed method provides a new direction for future open‐path sensors, facilitating the expansion of accurate EC flux measurements.

47 OTHER INSTRUMENTATION↗

Feasibility Study of Spectrophotometry to Support a Promethium Production Program at ORNL

Optical spectroscopy can be used to optimize analytical measurements for lanthanide elements and provide real-time feedback to help guide production operations. This study evaluates spectrophotometry for the determination of samarium (Sm 3+ ) and neodymium (Nd 3+ ) in aqueous and organic solutions at concentrations relevant to a promethium (Pm) program separation scheme. Detection limits approached 0.5 mM for Nd 3+ and 2 mM for Sm 3+ using Ocean Insight spectrophotometers. Additionally, Sm 3+ detection limits using laser fluorescence spectra for Sm 3+ approached single ppm (mg∙L -1 ) levels. An absorption spectrum containing Nd and Pm is also reported and discussed. This work demonstrates proofof-principle concepts for applying spectrophotometry to online monitoring applications in support of a future Pm production program.

47 OTHER INSTRUMENTATION↗

Vertex finding in neutrino-nucleus interaction: a model architecture comparison

We compare different neural network architectures for machine learning algorithms designed to identify the neutrino interaction vertex position in the MINERvA detector. The architectures developed and optimized by hand are compared with the architectures developed in an automated way using the package “Multi-node Evolutionary Neural Networks for Deep Learning” (MENNDL), developed at Oak Ridge National Laboratory. While the domain-expert hand-tuned network was the best performer, the differences were negligible and the auto-generated networks performed as well. There is always a trade-off between human, and computer resources for network optimization and this work suggests that automated optimization, assuming resources are available, provides a compelling way to save significant expert time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Method for High Resolution Surface Change Detection: Data Collection and Validation of Measurements from UAS at the Nevada National Security Site, Nevada, USA

The use of uncrewed aerial systems (UAS) increases the opportunities for detecting surface changes in remote areas and in challenging terrain. Detecting surface topographic changes offers an important constraint for understanding earthquake damage, groundwater depletion, effects of mining, and other events. For these purposes, changes on the order of 5–10 cm are readily detected, but sometimes it is necessary to detect smaller changes. An example is the surface changes that result from underground explosions, which can be as small as 3 cm. Previous studies that described change detection methodologies were generally not aimed at detecting sub-5-cm changes. Additionally, studies focused on high-fidelity accuracy were either computationally modeled or did not fully provide the necessary examples to highlight the usability of these workflows. Detecting changes at this threshold may be critical in certain applications, such as global security research and monitoring for high-consequence natural hazards, including landslides. Here we provide a detailed description of the methodology we used to detect 2–3 cm changes in an important applied research setting—surface changes related to underground explosions. This methodology improves the accuracy of change detection data collection and analysis through the optimization of pre-field planning, surveying, flight operations, and post-processing the collected data, all of which are critical to obtaining the highest output data resolution possible. We applied this methodology to a field study location, collecting 1.4 Tb of images over the course of 30 flights, and location data for 239 ground control points (GCPs). We independently verified changes with orthoimagery, and found that structure-from-motion, software-reported root mean square errors (RMSEs) for both control and check points underestimated the actual error. We found that 3 cm changes are detectable with this methodology, thereby improving our knowledge of a rock’s response to underground explosions.

47 OTHER INSTRUMENTATION↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

High-Performance/-Precision/-Z(HPPZ) Scintillator Grids via Advanced Electrochemistry. Phase I – Project # 20210572MFR- Mid year review [Slides]

Scintillation grids with improved imaging resolution in time and space, are required for future mission needs at various facilities (pRad user station, LANSCE, DARHT, Scorpius etc). Current technologies use inorganic crystal scintillators, which are positioned within a high-Z scintillator septa. Dense and high-Z materials are optimal for gamma-ray detection making them promising candidates for development of high -performance/-precision/-Z (HPPZ) scintillator grids. The current resolution of standard chemical etching and fabrication processes of high-Z materials is very low, leading to undesired undercutting and ultimately reducing crystal performance efficiency. Goals are to: Perform initial feasibility studies with the aim of producing complex parts for applications with difficult-to-process high-Z material; Use of pulse and pulse-reverse electrochemical methods on additive approaches to produce high-precision Au and Re scintillator grids at a small scale; and, Follow up in Phase II with the delivery of a large-scale scintillator grid of the best material candidate with unprecedented properties for LANL needs determined in Phase I.

36 MATERIALS SCIENCE↗

Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy

Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0–75°), ETRS set temperature (T ETRS , 30–40 °C), ambient temperature (T atm , 18–32 °C), relative humidity (RH, 15–80%), and working distance (d, 0.4–2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of T atm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal T ETRS for EBT detection was 36–37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature (T CS ) of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2–3.0 m, T atm of 15–35 °C, and RH of 5–95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.

47 OTHER INSTRUMENTATION↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

SPND Sensitivity Calculations Using MCNP and Experimental Data from ACRR

The use of the Monte Carlo N-Particle Transport Code (MCNP) to calculate detector sensitivity for Self-Powered Neutron Detectors (SPNDs) in the Annular Core Research Reactor (ACRR) could be a vital tool in the effort to optimize the design of next-generation SPNDs. Next-generation SPND designs, which consider specific materials and geometry, may provide experimenters with capabilities for advanced mixed field dosimetry. These detectors will need to be optimized for configuration, materials, and geometries and the ability to model and iterate must be available in order to decide on the ideal. SPND design. SPNDs were modeled in MCNP which closely resembled the dimensions and location of actual detectors used in the ACRR. Tallies were used to calculate detector sensitivity. Using metrics from a previous report, oscilloscope data from pulses were manipulated in a Matrix Laboratory computing environment (MATLAB) script to calculate experimental detector sensitivity. This report outlines the process in which experimental data from ACRR pulses verified results from tallies in an MCNP ACRR model. The sensitivity values from experiments and MCNP calculations agreed within one standard deviation. Parametric studies were also performed with MCNP to investigate the effects of materials and dimensions of different SPNDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗