Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

International Radiological/Nuclear Training for Emergency Response - Major Public Events Virtual Workshop: Nuclear Security Planning and Operations (Day 3) [Slides]

This module will provide a basic overview of radiological/nuclear search operations, including the application of radiological detection instrumentation and best practices for operational tactics, techniques and procedures. This module will introduce basic radiological/nuclear search operations and include the following: (1) A review of the principles of optimizing detection, (2) An understanding of radiation hazards and alarms, and (3) An examination of nuclear security measures best practices for buildings and stadium complexes, large areas, roadways and parking areas, and pedestrian and vehicle entrance portals.

61 RADIATION PROTECTION AND DOSIMETRY↗

Visualizing Solution Structure at Solid-Liquid Interfaces using Three-Dimensional Fast Force Mapping

Amongst the challenges for a variety of research fields are the visualization of solid-liquid interfaces and understanding how they are affected by the solution conditions such as ion concentrations, pH, ligands, and trace additives, as well as the underlying crystallography and chemistry. Here, in this context, three-dimensional fast force mapping (3D FFM) has emerged as a promising tool for investigating solution structure at interfaces. This capability is based on atomic force microscopy (AFM) and allows the direct visualization of interfacial regions in three spatial dimensions with sub-nanometer resolution. Here we provide a detailed description of the experimental protocol for acquiring 3D FFM data. The main considerations for optimizing the operating parameters depending on the sample and application are discussed. Moreover, the basic methods for data processing and analysis are discussed, including the transformation of the measured instrument observables into tip-sample force maps that can be linked to the local solution structure. Finally, we shed light on some of the outstanding questions related to 3D FFM data interpretation and how this technique can become a central tool in the repertoire of surface science.

Nakouzi, Elias↗

Particle detection by a light-scattering technique

Instrument measures concentration of small particles in aqueous medium in terms of amount of light scattered and degree to which light transmission is attenuated. Sensitivity to small particles is optimized because both scattered and transmitted illumination levels are detected by photodiodes.

Kormanyos, S.↗

A sleep diary and questionnaire study of naturally short sleepers

Whereas most people require more than 6 h of sleep to feel well rested, there appears to be a group of people who can function well on between 3 and 6 h of sleep. The aims of the present study were to compare 12 naturally short (3-6 h) sleepers (9 males 3 females, mean age 39.6 years, SD age 10.1 years) recruited by a media publicity campaign with age, gender and chronotype matched medium length (7-8.5 h) sleepers on various measures. Measurement instruments included diaries and questionnaires to assess sleep duration and timing, as well as questionnaire assessments of sleep pathology, morningness-eveningness, extroversion, neuroticism, pathological daytime sleepiness, subclinical hypomania, optimism, depressive symptoms, exercise, and work habits. Few measures showed reliable differences between naturally short sleepers and controls except the obvious ones related to sleep duration. There was, however, some evidence for subclinical hypomanic symptoms in naturally short sleepers.

NASA Discipline Regulatory Physiology↗

Improved Nuclear Reactor and Shield Mass Model for Space Applications

New technologies are being developed to explore the distant reaches of the solar system. Beyond Mars, solar energy is inadequate to power advanced scientific instruments. One technology that can meet the energy requirements is the space nuclear reactor. The nuclear reactor is used as a heat source for which a heat-to-electricity conversion system is needed. Examples of such conversion systems are the Brayton, Rankine, and Stirling cycles. Since launch cost is proportional to the amount of mass to lift, mass is always a concern in designing spacecraft. Estimations of system masses are an important part in determining the feasibility of a design. I worked under Michael Barrett in the Thermal Energy Conversion Branch of the Power & Electric Propulsion Division. An in-house Closed Cycle Engine Program (CCEP) is used for the design and performance analysis of closed-Brayton-cycle energy conversion systems for space applications. This program also calculates the system mass including the heat source. CCEP uses the subroutine RSMASS, which has been updated to RSMASS-D, to estimate the mass of the reactor. RSMASS was developed in 1986 at Sandia National Laboratories to quickly estimate the mass of multi-megawatt nuclear reactors for space applications. In response to an emphasis for lower power reactors, RSMASS-D was developed in 1997 and is based off of the SP-100 liquid metal cooled reactor. The subroutine calculates the mass of reactor components such as the safety systems, instrumentation and control, radiation shield, structure, reflector, and core. The major improvements in RSMASS-D are that it uses higher fidelity calculations, is easier to use, and automatically optimizes the systems mass. RSMASS-D is accurate within 15% of actual data while RSMASS is only accurate within 50%. My goal this summer was to learn FORTRAN 77 programming language and update the CCEP program with the RSMASS-D model.

Robb, Kevin↗

Satellite Data Simulator Unit: A Multisensor, Multispectral Satellite Simulator Package

Several multisensor simulator packages are being developed by different research groups across the world. Such simulator packages [e.g., COSP , CRTM, ECSIM, RTTO, ISSARS (under development), and SDSU (this article), among others] share overall aims, although some are targeted more on particular satellite programs or specific applications (for research purposes or for operational use) than others. The SDSU or Satellite Data Simulator Unit is a general-purpose simulator composed of Fortran 90 codes and applicable to spaceborne microwave radiometer, radar, and visible/infrared imagers including, but not limited to, the sensors listed in a table. That shows satellite programs particularly suitable for multisensor data analysis: some are single satellite missions carrying two or more instruments, while others are constellations of satellites flying in formation. The TRMM and A-Train are ongoing satellite missions carrying diverse sensors that observe clouds and precipitation, and will be continued or augmented within the decade to come by future multisensor missions such as the GPM and Earth-CARE. The ultimate goals of these present and proposed satellite programs are not restricted to clouds and precipitation but are to better understand their interactions with atmospheric dynamics/chemistry and feedback to climate. The SDSU's applicability is not technically limited to hydrometeor measurements either, but may be extended to air temperature and humidity observations by tuning the SDSU to sounding channels. As such, the SDSU and other multisensor simulators would potentially contribute to a broad area of climate and atmospheric sciences. The SDSU is not optimized to any particular orbital geometry of satellites. The SDSU is applicable not only to low-Earth orbiting platforms as listed in Table 1, but also to geostationary meteorological satellites. Although no geosynchronous satellite carries microwave instruments at present or in the near future, the SDSU would be useful for future geostationary satellites with a microwave radiometer and/or a radar aboard, which could become more feasible as engineering challenges are met. In this short article, the SDSU algorithm architecture and potential applications are reviewed in brief.

Masunaga, Hirohiko↗

The SWIFT Gamma-Ray Burst X-Ray Telescope

The Swift Gamma-Ray Burst Explorer is designed to make prompt multi-wavelength observations of Gamma-Ray Bursts and GRB afterglows. The X-ray Telescope enables Swift to determine GRB positions with a few arcseconds accuracy within 100 seconds of the burst onset. The XRT utilizes a mirror set built for JET-X and an XMM-Newton/ EPIC MOS CCD detector to provide a sensitive broad-band (0.2-10 keV) X-ray imager with an effective area of more than 120 sq cm at 1.5 keV, a field of view of 23.6 x 23.6 arcminutes, and an angular resolution of 18 arcseconds (HPD). The detection sensitivity is 2x10(exp 14) erg/sq cm/s in 10(exp 4) seconds. The instrument provides automated source detection and position reporting within 5 seconds of target acquisition. It can also measure the redshifts of GRBs with Iron line emission or other spectral features. The XRT operates in an auto-exposure mode, adjusting the CCD readout mode automatically to optimize the science return as the source intensity fades. The XRT measures spectra and lightcurves of the GRB afterglow beginning about a minute after the burst and follows each burst for days or weeks. We provide an overview of the X-ray Telescope scientific background from which the systems engineering requirements were derived, with specific emphasis on the design and qualification aspects from conception through to launch. We describe the impact on cleanliness and vacuum requirements for the instrument low energy response and to maintain the high sensitivity to the fading signal of the Gamma-ray Bursts.

Hill, J. E.↗

Optimal Spectral Resolution for Infrared Studies of Solids and Liquids

Due to a legacy originating in the limited capability of early computers, the spectroscopic resolution used in Fourier transform infrared spectroscopy and other systems has largely been implemented using only powers of two for more than 50 years. In this study, we investigate debunking the spectroscopic lore of, e.g., using only 2, 4, 8, or 16 cm −1 resolution and determine the optimal resolution in terms of both (i) a desired signal-to-noise ratio and (ii) efficient use of acquisition time. The study is facilitated by the availability of solids and liquids reference spectral data recorded at 2.0 cm −1 resolution and is based on an examination in the 4000–400 cm −1 range of 61 liquids and 70 solids spectra, with a total analysis of 4237 peaks, each of which was also examined for being singlet/multiplet in nature. Of the 1765 liquid bands examined, only 27 had widths <5 cm −1 . Of the 2472 solid bands examined, only 39 peaks have widths <5 cm −1 . For both the liquid and solid bands, a skewed distribution of peak widths was observed: For liquids, the mean peak width was 24.7 cm −1 but the median peak width was 13.7 cm −1 , and, similarly, for solids, the mean peak width was 22.2 cm −1 but the median peak width was 11.2 cm −1 . While recognizing other studies may differ in scope and limiting the analysis to only room temperature data, we have found that a resolution to resolve 95% of all bands is 5.7 cm −1 for liquids and 5.3 cm −1 for solids; such a resolution would capture the native linewidth (not accounting for instrumental broadening) for 95% of all the solids and liquid bands, respectively. After decades of measuring liquids and solids at 4, 8, or 16 cm −1 resolution, we suggest that, when accounting only for intrinsic linewidths, an optimized resolution of 6.0 cm −1 will capture 91% of all condensed-phase bands, i.e., broadening of only 9% of the narrowest of bands, but yielding a large gain in signal-to-noise with minimal loss of specificity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing Monte Carlo Simulation and an Optimal Machine Learning to Optimize and Model Space Missions

This paper investigates applying artificial intelligence (AI) algorithms to attitude control system of satellites to optimally tune the controller using high performance computing. This methodology is applied to the Virtual Telescope for X-ray Observation mission, which is a precise formation of two separate spacecraft observing multiple objects in the space in the X-ray domain. The mission is divided into phases based on the instrumentation and the mission goal. To reach an stable precise formation robust to stochastic slew and slew rate (i.e., Euler angles and angular velocities) in a minimal constrained time T , consumed energy of the attitude control system, denoted as E, and root-mean-square state error of attitude control system, denoted as e, are minimized. Monte-Carlo simulation is used for the sensitivity analysis of optimization and designing a controller. Deep neural networks (DNN), Gaussian processes (GP), and support vector regression (SVR) learn this optimization as a surrogate model, while their hyperparameters are optimized in a novel approach. THETA supercomputer at Argonne Leadership Computing Facility (ALCF) is used for optimizing the hyperparameters of DNN. The surrogate model meets the requirements of the mission, and it shows a better performance over the optimization and Monte-Carlo. The optimal DNN can satisfy the mission requirements e and T while reducing E for 90% compared to the other given methods.

42 ENGINEERING↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, a LIBS system was designed and assembled at NASA Langley Research Center (LaRC) to enable detection of ultralow concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization of CFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is also presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity.

Surface characterization, Carbon fiber reinforced ↗

Multi-Parameter Aerosol Scattering Sensor

This work relates to the development of sensors that measure specific aerosol properties. These properties are in the form of integrated moment distributions, i.e., total surface area, total mass, etc., or mathematical combinations of these moment distributions. Specifically, the innovation involves two fundamental features: a computational tool to design and optimize such sensors and the embodiment of these sensors in actual practice. The measurement of aerosol properties is a problem of general interest. Applications include, but are not limited to, environmental monitoring, assessment of human respiratory health, fire detection, emission characterization and control, and pollutant monitoring. The objectives for sensor development include increased accuracy and/or dynamic range, the inclusion in a single sensor of the ability to measure multiple aerosol properties, and developing an overall physical package that is rugged, compact, and low in power consumption, so as to enable deployment in harsh or confined field applications, and as distributed sensor networks. Existing instruments for this purpose include scattering photometers, direct-reading mass instruments, Beta absorption devices, differential mobility analyzers, and gravitational samplers. The family of sensors reported here is predicated on the interaction of light and matter; specifically, the scattering of light from distributions of aerosol particles. The particular arrangement of the sensor, e.g. the wavelength(s) of incident radiation, the number and location of optical detectors, etc., can be derived so as to optimize the sensor response to aerosol properties of practical interest. A key feature of the design is the potential embodiment as an extremely compact, integrated microsensor package. This is of fundamental importance, as it enables numerous previously inaccessible applications. The embodiment of these sensors is inherently low maintenance and high reliability by design. The novel and unique features include the underlying computational underpinning that allows the optimization for specific applications, and the physical embodiment that affords the construction of a compact, durable, and reliable integrated package. The advantage appears in the form of increased accuracy relative to existing instruments, and the applications enabled by the physical attributes of the resulting configuration

Greenberg, Paul S.↗

A liquid hydrogen tube moderator arrangement for SNS second target station

Liquid hydrogen filled tubes arranged in a triangular shape surrounded by light-water premoderators were investigated as cold moderators coupled to a neutron production zone of a tungsten target fed by a 1.3 GeV proton beam in a short-pulse mode. A moderator concept optimized for the tube length, premoderator thickness, and target position was found to deliver the highest pulse-integrated neutron brightness suitable to send cold neutron beams for neutron scattering instrumentation geared toward medium resolution and small samples. Reducing the tube diameter from 50 to 10 mm boosts the cold neutron brightness (E < 10 meV) by a factor of 2.25, also with enhancements seen by downsizing the height of cylindrical moderators in earlier studies. Attempts were made to characterize this novel moderator system with regard to pulse shapes, local brightness distribution, and angular distribution of emission at the neutron emission port.

Gallmeier, Franz X. (ORCID:0000000171500764)↗

Photon Doppler velocimetry surface return study for common surface preparations

Photon Doppler velocimetry (PDV) is a ubiquitous diagnostic method in dynamic compression experiments. It typically requires the roughening of the test surface to ensure scattering of the probe light back into the PDV probe at non-normal angles of incidence. Although surface scattering plays an essential role in the quality of PDV data, surface scattering properties for common materials and preparations have not previously been studied with specific relevance to PDV. Here, we present detailed measurements of the bidirectional reflectance distribution function for four different surface preparations (Scotch-Brite hand and drill roughened, ball-rolled, and grit blasted) and four different materials (copper, aluminum, stainless steel, and tantalum). These measurements employ a conventional PDV probe and obtain a diffraction limited angular resolution with 10 pW accuracy and 2.6% repeatability. In addition to scattering data, we employ scattering theory and simulations to accurately emulate the measured data. We also present a straightforward method to derive the average scattering distribution from surface profilometry and observe several qualitative aspects of the scattering data that may help to optimize PDV signals.

42 ENGINEERING↗

Integrated and dynamic multi-spectroscopic in situ imaging of plant metabolism at the level of subcellular compartments. Final Report

The goals of this project was to develop integrated multi-spectral molecular imaging technologies (Raman, fluorescence, and mass spectrometry), that can assess, and image metabolic processes at the cellular and subcellular levels of plant organs. These imaging technologies were developed in the context of computational capabilities that integrated multi-spectral images with genome scale models of metabolism. The integrated molecular imaging technologies were developed in the biological context of autophagy that remodels membrane lipid topologies, which control spatially defined subcellular regions within plant cells and optimizes plant biomass productivity during environmental stresses that can limit biomass productivity.

09 BIOMASS FUELS↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

Abstract—The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Cohesive Deep Drilling Field Strategy for LSST Cosmology

The Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) will image billions of astronomical objects in the wide–fast–deep primary survey and in a set of minisurveys including intensive observations of a group of deep drilling fields (DDFs). The DDFs are a critical piece of three key aspects of the LSST Dark Energy Science Collaboration (DESC) cosmological measurements: they provide a required calibration for photometric redshifts (photo- z ) and weak gravitational lensing (WL) measurements and they directly contribute to cosmological constraints from the most distant Type Ia supernovae (SNe Ia). We present a set of cohesive DDF strategies fulfilling science requirements relevant to DESC and following the guidelines of the Survey Cadence Optimization Committee. We propose a method to estimate the observing strategy parameters and we perform simulations of the corresponding surveys. We define a set of metrics for each science case to assess the performance of the proposed observing strategies. We show that the most promising results are achieved with deep rolling surveys characterized by two sets of fields: ultradeep fields ( z ≲ 1.1) observed at a high cadence with a large number of visits over a limited number of seasons, and deep fields ( z ≲ 0.7), observed with a cadence of ~3 nights for 10 yr. These encouraging results should be confirmed with realistic simulations using the LSST scheduler. A DDF budget of ~8.5% is required to design observing strategies satisfying all the cosmological requirements. A lower DDF budget leads to surveys that either do not fulfill the photo- z /WL requirements or are not optimal for SN Ia cosmology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗