Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Metal-line absorption at Z(sub abs) approximately Z(sub em) from associated galaxies

For a preliminary study of whether C IV absorption at Z(sub abs) approximately Z(sub em) is related to associated galaxy companions, we have collected data from a sample of 10 quasars with 0.15 less than z less than 0.65 for which high-resolution optical and UV spectroscopy is available from the literature, and for which we have deep optical images and limited spectroscopy. We also present new optical spectra for two of our samples. Four of these quasars have associated C IV absorption systems. In thes four fields, there are eight galaxies with M(sub r) less than -19.0 mag within 35 kpc of the quasar (projected distance, assuming they are at the quasar redshift), which may be candidates for the associated C IV absorption. This observed density of galaxies near quasars with associated C IV absorption is significantly greater than that for a control sample of quasars chosen from the literature. This result suggests that galaxies near the quasar line of sight may be linked with associated C IV absorption. None of these quasars show associated Mg II absorption, despite the presence of galaxies very near the line of sight, suggesting a Mg II 'proximity effect,' where ionizing flux from the quasar destroys the Mg(+) from at least the outer parts of the galaxies. Three quasars are located in rich galaxy clusters, but none of these quasars are found to have associated C IV absorption. This suggests that galaxies in rich clusters associated with quasars are less likely to be metal-line absorbers. It is plausible that the extended galaxy halos which may be responsible for the absorptions are stripped from galaxies in these dense environments. While it seems that at Z approximately 0.6 rich clusters do not cause them, associated C IV absorption systems at higher redshift may be explained by associated clusters if there has been evolution in the properties of galaxy halos in dense environments.

Ellingson, E.↗

SHERLOC: Results of the first 350 sols of operations

On February 18th 2021, the Perseverance rover landed in Jezero crater, Mars. This site was chosen because orbiter data analysis provides evidence that the crater hosted a stream-fed lake during the Martian Noachian period. The Octavia Butler landing site is located ~1.9 km east of the remnants of a river delta. Deltaic and lacustrine sediments can preserve biosignatures, making Jezero crater a prime target for Mars sample return science. One of the seven instruments on Perseverance’s science payload is SHERLOC –Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals. SHERLOC combines fluorescence and Raman spectroscopy with microscopic imaging to analyze surface material to better understand the history of the aqueous environments recorded in the rocks of Jezero crater and to search for potential biosignatures. SHERLOC imaging obtains high spatial resolution images of geological targets to identify grain-scale structure and texture. SHERLOC spectroscopy enables high-sensitivity detection, characterization, and spatially resolved correlation of trace organic materials. Native fluorescence emissions from aromatic organic species allow for detection and classification of aromatic organic molecules, whereas Raman scattered photons from molecules allow identification of functional groups of organics, chemicals, and minerals. In the first 300 sols, SHERLOC has analyzed 3 natural surfaces, and 5 abraded rock patches created during the Crater Floor Campaign within Jezero crater. SHERLOC has been able to identify phosphates, amorphous/microcrystalline silicate (AMS), olivine, sulfates, and carbonates in abraded patches in the green zone campaign within Jezero Crater Máaz and Séítah formations. Within these detections we have begun to tell the story of what this crater was like when it was full of liquid water over 3 billion years ago. In each of these samples we have identified fluorescence features that are likely aromatic organics native to the rock interiors. We have identified multiple unique fluorescence signatures, within each of the abraded patches. The organic signatures have either been widely distributed over an extended area, which is probably due to planetary wide dust, or have spatially resolved locations that are collocated with different mineral signatures. Note: Additional information available on attachment.

L. W. Beegle↗

Direct mechanistic connection between acoustic signals and melt pool morphology during laser powder bed fusion

Various nondestructive diagnostic techniques have been proposed for in situ process monitoring of laser powder bed fusion (LPBF), including melt pool pyrometry, whole-layer optical imaging, acoustic emission, atomic emission spectroscopy, high speed melt pool imaging, and thermionic emission. Correlations between these in situ monitoring signals and defect formation have been demonstrated with acoustic signals having been shown to predict pore formation with especially high confidence in recent machine learning studies. Here, in this work, time-resolved acoustic data are collected in both the conduction and keyhole welding regimes of LPBF-processed Ti-6Al-4V alloy. A non-dimensionalized Strouhal number analysis, used in whistle aeroacoustics, is applied to demonstrate that the acoustic signals recorded in the keyhole regimes can be directly associated with the vapor depression morphology. This mechanistic understanding developed from whistle aeroacoustics shows that acoustic monitoring during the LPBF process can provide a direct probe into the vapor depression dynamics and defect occurrence, especially in the keyhole regimes relevant to printing and defect formation.

36 MATERIALS SCIENCE↗

Velocity, Temperature and Density Measurements in Supersonic Jets

Prediction of the flow field properties in supersonic jets using computational fluid dynamics (CFD) codes is challenging when there is a significant temperature difference between the jet core and the ambient air and/or compressibility effects are substantial. A benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Three different convergent-divergent nozzles were investigated with exit Mach numbers of: 1.36, 1.63 and 2.0 at their perfectly expanded conditions. The conditions of the jet were set to obtain a temperature difference of zero between the jet core and the ambient air, and then the temperature difference was progressively increased, at the same jet Mach number. Particle Image Velocimetry (PIV), spontaneous rotational Raman scattering spectroscopy (SRS), Background Oriented Schlieren (BOS) and probe-based measurements were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms gas temperatures and densities in both hot and cold supersonic jet flows. The non-intrusive flow measurements are compared both against probe measurements and against standard Reynolds averaged Navier-Stokes (RANS) predictions of the supersonic jet flow properties.

Raman Spectroscopy↗

The Role of Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology: Proceedings of a Workshop

Quantum concepts hold the potential to enable significant advances in sensing and imaging technologies that could be vital to the study of biological systems. The workshop Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology, held online March 8–10, 2021, was organized to examine the research and development needs to advance biological applications of quantum technology. Hosted by the National Academies of Sciences, Engineering, and Medicine, the event brought together experts working on state-of-the-art, quantum-enabled technologies and scientists who are interested in applying these technologies to biological systems. Through talks, panels, and discussions, the workshop facilitated a better understanding of the current and future biological applications of quantum-enabled technologies in fields such as microbiology, molecular biology, cell biology, plant science, mycology, and many others. The workshop was organized around three main themes. The first, quantum in biology, examined quantum concepts that are hypothesized to be important for life processes and that researchers are working to observe through biological imaging and sensing. The second, quantum for biology, addressed ways to use quantum concepts to enhance technologies for biological imaging and sensing. The third, biology for quantum, offered a wider discussion of how the frontiers of biological imaging and sensing could enable future study using quantum concepts, tools, or technologies. Throughout the workshop, participants identified a wide range of emerging approaches and opportunities at the intersection of quantum physics and biological sensing and imaging. During the workshop, there were some differences in how each speaker defined the term quantum. During one of the panels, Prem Kumar offered thoughts on what phenomena are classical versus quantum, explaining that techniques get progressively more quantum as you move from just having superposition to having superposition with measurement and entanglement. Another explanation from Clarice Aiello delineates the definition into several levels. This includes a base level of “quantum-ness,” which reflects that all matter is made of atoms, and when these particles are isolated they behave based on quantum mechanical principles. A second level is related to quantum coherence, where a single quantum object might be found in a coherent superposition state. A final level, which she described as the quantum-entangled level, involves multiple quantum systems which are entangled among themselves. Overall, the workshop touched on concepts such as superposition, entanglement, and squeezing and their potential implications for communication, computing, and simulation, in addition to the workshop’s main focal area, biological sensing and imaging. At the opening of the workshop, Thorsten Ritz of the University of California, Irvine, identified two questions at the heart of quantum biology: Is the machinery of life quantum mechanical, and can quantum mechanics be used to study the machinery of life in new ways? Participants highlighted systems in which researchers have explored these questions, from the vast array of molecular interactions involved in biological processes such as photosynthesis, to the mechanics involved in cellular functions such as differentiation and aggregation, to the role of oscillating magnetic fields in flight orientation among birds. Sensing and imaging technologies are crucial to biological research; these technologies could both enhance the study of quantum effects and be enhanced by quantum concepts. A critical challenge in biological research is to develop imaging and sensing tools that do not damage or interfere with the often fragile and fleeting systems being studied. Attendees discussed a variety of established and emerging technologies that could enhance noninvasive biological imaging, including single- and two-photon spectroscopy, single-molecule spectroscopy, quantum illumination, ghost imaging, and cryo-electron microscopy. One example came from Marlan Scully who gave a keynote address on the first day of the workshop. Scully emphasized the use of different laser technologies, which exhibit coherence and other quantum properties, in moving toward real-world biological applications, such as the detection of SARS-CoV-2. Both tools and theory will play an important role in advancing quantum biology research and applications. Several participants suggested theorists and experimentalists should work in tandem to understand and model biological processes. While physics often reduces systems to their simplest forms for fundamental insights, participants also noted the value of observing and understanding biological systems in all their “messiness,” capturing both the inner workings of biological systems and the complex interactions that occur within and between organisms. In discussions among participants, several attendees stressed the need to match emerging tools with the right scientific questions. Rather than developing quantum technologies as “a hammer looking for a nail,” participants emphasized a focus on exploring the problems these technologies are best suited to address. For example, it is important to consider the size of the phenomenon being studied, the timescales that are important in answering the scientific question, and other relevant considerations. Every tool along the spectrum from classical to quantum involves its own set of trade-offs. For example, Ted Laurence of the Lawrence Livermore National Laboratory said that quantum measurements, such as single photon counting, fluorescence transitions, and lasers, can take longer to produce the same results as classical measurements. These quantum measurements, however, do not require calibration and can enable new research questions to be answered. Prem Kumar, Northwestern University, noted that, despite their promise, quantum approaches should not be used simply for the sake of using quantum, especially in situations where classical approaches better meet the needs of the researcher. Understanding and applying quantum concepts could enable advances in a wide range of application areas including energy, synthetic biology, medicine, and sustainability. For example, Michelle O’Malley, University of California, Santa Barbara, described how improved noninvasive imaging approaches could help capture the complex interactions and functions involved in the breakdown of organic matter by microbial communities and lead to new technologies for capturing valuable products from plant waste. Several other participants discussed needs in tracking the movement of metabolites and molecules in microbial communities for insights into nutrient cycling in environments such as soil. Margaret Ahmad, Sorbonne University, discussed potential opportunities to leverage the magnetic properties of cryptochromes to advance new treatment approaches for diseases such as COVID-19 and cancer. Looking toward the future development of the field, participants discussed challenges to advancing quantum biology that arise from disciplinary disconnects between physicists and biologists. The siloing of academic research disciplines represents a significant barrier to progress. Disconnects in terminology, motivations and priorities, and structural barriers to collaborative work underscore the need for concerted efforts to bridge these divides. Attendees and speakers offered suggestions for resolving these divergences, establishing a shared language, moving the field forward, and fostering meaningful feedback between disciplines. Overall, participants stressed a need for balance, open communication, collaboration, unity, and clear dialogue on trade-offs between quantum and classical approaches. Keiko Torii, The University of Texas at Austin, said that the best collaborations happen when the project provides mutual advantages that can show off everyone’s talents, each team finds the work interesting, and partners develop a camaraderie to pursue new knowledge. To enable near- and long-term opportunities in this space, participants suggested that exploratory, high-risk funding could improve existing instrumentation to explore quantum enhancement collaboratively. They also emphasized the need for collaboration between quantum physicists and sensing/imaging scientists, which could be advanced through a dedicated quantum biology investigator program. People, even more than technology, will be crucial to the future of quantum biology. Participants explored training, education, and workforce needs to further develop this burgeoning field and cultivate the next generation of scientists. While many programs are still in their nascent stages, participants highlighted examples of approaches and programs being developed at various types of institutions to engage students and professional scientists in quantum biology research. Several participants stressed the need for an inclusive approach, spanning disciplines as well as communities to foster a diverse field fueled by the intellectual contributions of a wide range of people, including historically under-resourced schools and students. To increase awareness and excitement about quantum physics and related areas of biology, attendees suggested capitalizing on the “buzz” around quantum. Several participants emphasized the need to start early, introducing students to quantum concepts and their appealing “weirdness” in K–12 education. Engaging students early—before they become entrenched in traditional disciplinary siloes as typically happens in graduate school—could help to galvanize interest in the area and foster a generation of scientists with the interdisciplinary mindset and skills needed to advance this interdisciplinary field. While these efforts could be advanced at many levels and across multiple sectors, several participants suggested a national quantum biology center could be a valuable hub to coordinate and support quantum biology education and workforce development across academia, industry, and government.

59 BASIC BIOLOGICAL SCIENCES↗

Multispectral Microimager for Astrobiology

A primary goal of the astrobiology program is the search for fossil records. The astrobiology exploration strategy calls for the location and return of samples indicative of environments conducive to life, and that best capture and preserve biomarkers. Successfully returning samples from environments conducive to life requires two primary capabilities: (1) in situ mapping of the mineralogy in order to determine whether the desired minerals are present; and (2) nondestructive screening of samples for additional in-situ testing and/or selection for return to laboratories for more in-depth examination. Two of the most powerful identification techniques are micro-imaging and visible/infrared spectroscopy. The design and test results are presented from a compact rugged instrument that combines micro-imaging and spectroscopic capability to provide in-situ analysis, mapping, and sample screening capabilities. Accurate reflectance spectra should be a measure of reflectance as a function of wavelength only. Other compact multispectral microimagers use separate LEDs (light-emitting diodes) for each wavelength and therefore vary the angles of illumination when changing wavelengths. When observing a specularly-reflecting sample, this produces grossly inaccurate spectra due to the variation in the angle of illumination. An advanced design and test results are presented for a multispectral microimager which demonstrates two key advances relative to previous LED-based microimagers: (i) acquisition of actual reflectance spectra in which the flux is a function of wavelength only, rather than a function of both wavelength and illumination geometry; and (ii) increase in the number of spectral bands to eight bands covering a spectral range of 468 to 975 nm.

microimager↗

Thermal Structure and Dynamics of Saturn's Northern Springtime Disturbance

This article combined several infrared datasets to study the vertical properties of Saturn's northern springtime storm. Spectroscopic observations of Saturn's northern hemisphere at 0.5 and 2.5 / cm spectral resolution were provided by the Cassini Composite Infrared Spectrometer (CIRS, 17). These were supplemented with narrow-band filtered imaging from the ESO Very Large Telescope VISIR instrument (16) to provide a global spatial context for the Cassini spectroscopy. Finally, nightside imaging from the Cassini Visual and Infrared Mapping Spectrometer (VIMS, 22) provided a glimpse of the undulating cloud activity in the eastern branch of the disturbance. Each of these datasets, and the methods used to reduce and analyse them, will be described in detail below. Spatial maps of atmospheric temperatures, aerosol opacity and gaseous distributions are derived from infrared spectroscopy using a suite of radiative transfer and optimal estimation retrieval tools developed at the University of Oxford, known collectively as Nemesis (23). Synthetic spectra created from a reference atmospheric model for Saturn and appropriate sources of spectroscopic line data (6, 24) are convolved with the instrument function for each dataset. Atmospheric properties are then iteratively adjusted until the measurements are accurately reproduced with physically-realistic temperatures, compositions and cloud opacities.

Fletcher, Leigh N.↗

Tip-Enhanced Raman Nanospectroscopy of Smooth Spherical Gold Nanoparticles

We record nanoscale-resolved chemical images of thiobenzonitrile (TBN)-functionalized smooth gold nanospheres on silicon via tip-enhanced Raman (TER) nano-spectroscopy. The recorded images trace the nascence of the familiar doughnut-shaped scattering profile of nanoparticles on silicon at its origin (the particle surface), which appears as a horseshoe-shaped scattering pattern under our experimental conditions. The local optical field maps are in agreement with their simulated finite-difference time-domain analogues. Analysis of the recorded spectra with the aid of ab initio molecular dynamics-based Raman spectral simulations further suggests that optical rectification and molecular charging take place throughout the course of atomic force microscopy-based TER nanoscale chemical imaging.

Bhattarai, Ashish↗

Combined spectroscopic imaging STM and ARPES study of different gaps measured in the cuprate phase diagram

A comparative study of the gaps measured in two techniques, angle-resolved photoelectron spectroscopy and spectroscopic imaging scanning tunneling microscopy, is presented herein. In particular the study focuses on the more overdoped region of the cuprate phase diagram in the superconducting state. While the total densities of states measured in the two techniques agree very well, it is shown that the peak in the density of states, Δ DOS , is consistently displaced to higher energies relative to the maximal superconducting gap, Δ 0 , determined in photoemission. The difference between the two gaps is more evident for the less doped samples reflecting increased normalization of bands. This observation will clearly influence the boundaries in the phase diagrams of the cuprates defined by these two techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lessons for WFIRST CGI from Ground-Based High-Contrast Systems

The Coronagraph Instrument (CGI) for NASA’s Wide Field Infrared Survey Telescope (WFIRST) will constitute a dramatic step forward for high-contrast imaging, integral field spectroscopy, and polarimetry of exoplanets and circumstellar disks, aiming to improve upon the sensitivity of current ground-based direct imaging facilities by 2–3 orders of magnitude. Furthermore, CGI will serve as a pathfinder for future exo-Earth imaging and characterization missions by demonstrating wavefront control, coronagraphy, and spectral retrieval in a new contrast regime, and by validating instrument and telescope models at unprecedented levels of precision. To achieve this jump in performance, it is critical to draw on the experience of ground-based high-contrast facilities. We discuss several areas of relevant commonalities, including: wavefront control, post-processing of integral field unit data, and calibration and observing strategies.

Xuan, Wenhao↗

A temperature profile diagnostic for radiation waves on OMEGA-60

Predicting and matching radiation wave propagation with computational models has proven difficult. Information provided by experiments studying radiation flow has been limited when only radiation breakout is measured. We have developed the COAX (co-axial) diagnostic platform to provide spatial temperature profiles of a radiation wave through low density foams as a more detailed constraint for simulations. COAX uses a standard, laser-driven OMEGA-60 halfraum to drive radiation down a titanium-laden silicon oxide foam. Point-projection X-ray absorption spectroscopy perpendicular to the radiation flow measures the spatial profile of titanium ionization. The spectroscopic measurement utilizes a broadband capsule backlighter. Imaging and streak spectroscopy are used to characterize the size and spectrum of this source. Radiography provides an additional constraint by capturing the developing shock as the radiation flow becomes subsonic. The DANTE diagnostic is used to measure the halfraum temperature. Here, we provide a spectroscopic analysis of COAX data to determine temperature, and we describe experimental sources of uncertainty. The temperature is obtained by comparison to multi-temperature synthetic spectra post-processed from radiation-hydrodynamics simulations. Quantitative comparison between data and synthetic spectra generated from temperature profiles at relevant simulation times enable determination of a peak temperature of 114 ± 8 eV at 265 ± 22.4 μm from the halfraum. This represents an improvement over the temperature uncertainties of previous radiation flow experiments. Further refinements to the spectroscopic analysis could achieve ±4 eV. The combination between space-resolved spectroscopy and radiography enables us to determine the distance from the halfraum of both the radiation front and the shock front at the time of measurement. For the example shown in this paper the radiation front position is 600–630 μm at 3.43 ± 0.16 ns and the shock front position is 633 μm at 3.3 ± 0.24 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hyperspectral imaging of exciton confinement within a moiré unit cell with a subnanometer electron probe

Electronic and optical excitations in two-dimensional systems are distinctly sensitive to the presence of a moiré superlattice. Here we used cryogenic transmission electron microscopy and spectroscopy to simultaneously image the structural reconstruction and associated localization of the lowest-energy intralayer exciton in a rotationally aligned WS 2 -WSe 2 moiré superlattice. In conjunction with optical spectroscopy and ab initio calculations, we determined that the exciton center-of-mass wave function is confined to a radius of approximately 2 nanometers around the highest-energy stacking site in the moiré unit cell. Our results provide direct evidence that atomic reconstructions lead to the strongly confining moiré potentials and that engineering strain at the nanoscale will enable new types of excitonic lattices.

36 MATERIALS SCIENCE↗

High-Rate Data-Capture for an Airborne Lidar System

A high-rate data system was required to capture the data for an airborne lidar system. A data system was developed that achieved up to 22 million (64-bit) events per second sustained data rate (1408 million bits per second), as well as short bursts (less than 4 s) at higher rates. All hardware used for the system was off the shelf, but carefully selected to achieve these rates. The system was used to capture laser fire, single-photon detection, and GPS data for the Slope Imaging Multi-polarization Photo-counting Lidar (SIMPL). However, the system has applications for other laser altimeter systems (waveform-recording), mass spectroscopy, xray radiometry imaging, high-background- rate ranging lidar, and other similar areas where very high-speed data capture is needed. The data capture software was used for the SIMPL instrument that employs a micropulse, single-photon ranging measurement approach and has 16 data channels. The detected single photons are from two sources those reflected from the target and solar background photons. The instrument is non-gated, so background photons are acquired for a range window of 13 km and can comprise many times the number of target photons. The highest background rate occurs when the atmosphere is clear, the Sun is high, and the target is a highly reflective surface such as snow. Under these conditions, the total data rate for the 16 channels combined is expected to be approximately 22 million events per second. For each photon detection event, the data capture software reads the relative time of receipt, with respect to a one-per-second absolute time pulse from a GPS receiver, from an event timer card with 0.1-ns precision, and records that information to a RAID (Redundant Array of Independent Disks) storage device. The relative time of laser pulse firings must also be read and recorded with the same precision. Each of the four event timer cards handles the throughput from four of the channels. For each detection event, a flag is recorded that indicates the source channel. To accommodate the expected maximum count rate and also handle the other extreme of very low rates occurring during nighttime operations, the software requests a set amount of data from each of the event timer cards and buffers the data. The software notes if any of the cards did not return all the data requested and then accommodates that lower rate. The data is buffered to minimize the I/O overhead of writing the data to storage. Care was taken to optimize the reads from the cards, the speed of the I/O bus, and RAID configuration.

Valett, Susan↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Nearly degenerate two-color impulsive coherent Raman hyperspectral imaging

Impulsive stimulated Raman scattering (ISRS) is a robust technique for studying low frequency (<300 cm –1 ) Raman vibrational modes, but ISRS has faced difficulty in translation to an imaging modality. A primary challenge is the separation of the pump and probe pulses. Here we introduce and demonstrate a simple strategy for ISRS spectroscopy and hyperspectral imaging that uses complementary steep edge spectral filters to separate the probe beam detection from the pump and enables simple ISRS microscopy with a single-color ultrafast laser source. ISRS spectra are obtained that span from the fingerprint region down to <50 cm –1 vibrational modes. Furthermore, hyperspectral imaging and polarization-dependent Raman spectra are also demonstrated.

47 OTHER INSTRUMENTATION↗