Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Tests of high current hollow cathodes for ion engines

The development of high power, high thrust ion engines requires the development of long life hollow cathodes capable of producing emission currents of hundreds of amperes. This paper describes results obtained through the extended testing of two 12.7 mm diameter hollow cathodes at high emission currents. The first cathode, operated on xenon for a total of 170 hours at an emission current of 100 A, sustained very little damage except for an increase in the cathode orifice diameter, from 0.953 to 1.71 mm. The second cathode was operated on xenon at 150 A emission current continuously for 24 hours, and for over 1000 hours at 100 A on argon with essentially no change in the cathode operating characteristics. Operation of this cathode was terminated due to severe erosion of several discharge chamber components located downstream of the cathode. The erosion of these components occurred despite operation at discharge voltages less than 24 volts, and poses a serious challenge to the sucessful implementation of multi-hundred ampere cathodes and high thrust ion engines.

Brophy, John R.↗

Scanning ion sensitive probe for plasma profile measurements in the boundary of the Alcator C-Mod tokamak

A new Ion Sensitive Probe head has been created for the outer-midplane scanning probe system on the Alcator C-Mod tokamak. The new probe head contains three elements: an ion sensitive probe to measure ion temperature and plasma potential, a Langmuir probe to measure electron temperature, density, and floating potential, and a second Langmuir probe to measure ion saturation current and the density fluctuations arising from ''blob'' events. The ion sensitive probe current is normalized to this measurement to reduced deleterious effects of the strong fluctuations. Design of the high heat flux probe (>100 MW/m{sup 2}) and initial results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Currents between tethered electrodes in a magnetized laboratory plasma

Laboratory experiments on important plasma physics issues of electrodynamic tethers were performed. These included current propagation, formation of wave wings, limits of current collection, nonlinear effects and instabilities, charging phenomena, and characteristics of transmission lines in plasmas. The experiments were conducted in a large afterglow plasma. The current system was established with a small electron-emitting hot cathode tethered to an electron-collecting anode, both movable across the magnetic field and energized by potential difference up to V approx.=100 T(sub e). The total current density in space and time was obtained from complete measurements of the perturbed magnetic field. The fast spacecraft motion was reproduced in the laboratory by moving the tethered electrodes in small increments, applying delayed current pulses, and reconstructing the net field by a linear superposition of locally emitted wavelets. With this technique, the small-amplitude dc current pattern is shown to form whistler wings at each electrode instead of the generally accepted Alfven wings. For the beam electrode, the whistler wing separates from the field-aligned beam which carries no net current. Large amplitude return currents to a stationary anode generate current-driven microinstabilities, parallel electric fields, ion depletions, current disruptions and time-varying electrode charging. At appropriately high potentials and neutral densities, excess neutrals are ionized near the anode. The anode sheath emits high-frequency electron transit-time oscillations at the sheath-plasma resonance. The beam generates Langmuir turbulence, ion sound turbulence, electron heating, space charge fields, and Hall currents. An insulated, perfectly conducting transmission line embedded in the plasma becomes lossy due to excitation of whistler waves and magnetic field diffusion effects. The implications of the laboratory observations on electrodynamic tethers in space are discussed.

Stenzel, R. L.↗

Current collector clad with lithium ion conducting solid electrolyte

An article for forming an electrochemical device is disclosed. The article comprises a metallic current collector clad with an ion conducting solid-electrolyte material such that intimate contact between the current collector and the ion conducting solid-electrolyte material is made. A lithium metal anode can be formed in situ between the current collector clad and the ion conducting solid-electrolyte material from lithium ions contained within a cathode material that is placed in contact with the ion conducting solid-electrolyte material. A bipolar electrochemical cell can be constructed from the article.

Sakamoto, Jeffrey↗

Design and characterization of Ion sources for CHIP-TRAP

At Central Michigan University, we are developing a high-precision Penning trap mass spectrometer (CHIP-TRAP) for precise mass measurements with stable and long-lived isotopes. Ions will be produced using external ion sources and then transported to the Penning trap at low energy using electrostatic ion optics. Ion sources that will be utilized with CHIP-TRAP include a laser ablation ion source (LAS) that has already been commissioned, and a low current Penning ion trap (PIT) source that is currently being developed. The LAS enables ion production from solid targets via ablation and ionization with a high-powered laser pulse. The PIT source is a novel Penning ionization gauge (PIG) type source, consisting of a 0.55 T NdFeB ring magnet, cylindrical Penning trap, and low current thermal electron emitter that enables ion production via electron impact ionization of gaseous samples. For both ion sources, small bunches of ~100 – 1000 ions can be produced from a minimal sample of source material. Finally, the ion bunches are then transported along the CHIP-TRAP beamline, where time-of-flight mass filtering can be performed before they are captured in the CHIP-TRAP Penning traps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of a RF-Driven Ion Source for a Neutron Generator Used For Associated Particle Imaging

We present recent work on a prototype compact neutron generator for associated particle imaging (API). API uses alpha particles that are produced simultaneously with neutrons in the deuterium-tritium (2D(3T,n)4 alpha) fusion reaction to determine the direction of the neutrons upon exiting the reaction. This method determines the spatial position of each neutron interaction and requires the neutrons to be generated from a small spot in order to achieve high spatial resolution. The ion source for API is designed to produce a focused ion beam with a beam spot diameter of 1-mm or less on the target. We use an axial type neutron generator with a predicted neutron yield of 108 n/s for a 50 muA D/T ion beam current accelerated to 80 kV. The generator utilizes a RF planar spiral antenna at 13.56 MHz to create a highly efficient inductively-coupled plasma at the ion source. Experimental results show that beams with an atomic ion fraction of over 80percent can be obtained while utilizing only 100 watts of RF power in the ion source. A single acceleration gap with a secondary electron suppression electrode is used in the tube. Experimental results, such as the current density, atomic ion fraction, electron temperature, and electron density, from ion source testing will be discussed.

43 PARTICLE ACCELERATORS↗

Carbon Ion Radiotherapy At Gunma University: Currently Indicated Cancer And Estimation Of Need

Carbon ion radiotherapy for the first patient at Gunma University Heavy Ion Medical Center (GHMC) was initiated in March of 2010. The major specifications of the facility were determined based on the experience of clinical treatments at National Institute of Radiological Sciences (NIRS). The currently indicated sites of cancer treatment at GHMC are lung, prostate, head and neck, liver, rectum, bone and soft tissue. In order to evaluate the potential need for treatment in the region including Gunma prefecture and the adjacent 4 prefectures, an estimation model was constructed based on the Japanese cancer registration system, regular structure surveys by the Cancer Societies, and published articles on each cancer type. Carbon ion RT was potentially indicated for 8,085 patients and realistically for 1,527 patients, corresponding to 10% and 2% of the newly diagnosed cancer patients in the region. Prostate cancer (541 patients) followed by lung cancer (436 patients), and liver cancer (313 patients) were the most commonly diagnosed cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superhard Nanocrystalline Homometallic Stainless Steel on Steel for Seamless Coatings

The objective of this work is to deposit nanocrystalline stainless steel onto steel substrates (homometallic) for enhanced wear and corrosion resistance. Homometallic coatings provide superior adhesion, and it has been shown that ultrafine-grained materials exhibit the increased hardness and decreased permeability desired for protective coatings. Nanocrystals will be produced by controlling nucleation and growth and use of an ion beam during deposition by e-beam evaporation or sputtering. Phase I is depositing 31 6L nanocrystalline stainless steel onto 31 6L stainless steel substrates. These coatings exhibit hardnesses comparable to those normally obtained for ceramic coatings such ZrO2, and possess the superior adhesion of seamless, homometallic coatings. Hardening the surface with a similar material also enhances adhesion, by avoiding problems associated with thermal and lattice mismatch. So far we have deposited nanocrystalline homometallic 316L stainless steel coatings by varying the ions and the current density of the ion beams. For all deposition conditions we have produced smooth, uniform, superhard coatings. All coatings exhibit hardness of at least 200% harder than that of bulk materials. Our measurements indicate that there is a direct relationship between nanohardness and the current density of the ion beam. Stress measurements indicate that stress in the films is increasingly proportional to current density of the ion beam. TEM, XPS, and XRD results indicate that the coated layers consist of FCC structure nanocrystallites with a dimension of about 10 to 20 nm. The Ni and Mo concentration of these coating are lower than those of bulk 316L but the concentration of Cr is higher.

Tobin, Eric J.↗

The Role of Magnetic Reconnection in Energizing Protons and Heavier Ions at the Heliospheric Current Sheet

During near-Sun crossings of the heliospheric current sheet (HCS), Parker Solar Probe (PSP) observed populations of high-energy protons and heavier ions, indicating possible energization by magnetic reconnection up to 10 s–100 s keV nucleon −1 . Here we study ion acceleration by magnetic reconnection at the HCS. To estimate ion energization, we solve the Parker transport equation coupled to a large-scale 2D MHD reconnection simulation. We find that multiple ion species develop power-law distributions with both spectral index and high-energy cutoff E max consistent with in situ data. By accounting for the injection physics determined by kinetic simulations, we confirm that the charge-to-mass ratio scales as E max ∝ (Q/M) α with α ∼ 0.8–1.1, approximately consistent with PSP measurements in the broader range α ∼ 0.6–1.7. In the limit where ions are injected at the same energy per nucleon, α can be as low as ∼0.3. These findings further support the role of magnetic reconnection in producing high-energy heavy ions at the HCS.

Murtas, Giulia [West Virginia Univ., Morgantown, W↗

Multi-antenna RF Ion Source at a High RF Power Level

A multi-antenna radio-frequency ion source with a Faraday shield is newly tested at a high RF power level in a large area negative ion source of 1/5th scale of the Large Helical Device-NNBI ion source. Inductively coupled dense hydrogen plasmas were generated uniformly over an area of 25x25 cm{sup 2} at an RF input power up to 300 kW for a 10 ms pulse duration. A large negative plasma potential for the non-Faraday shielded antenna was remarkably reduced by introducing a Faraday shield. The positive ion saturation current density measured by Langmuir probe reached 148 mA/cm{sup 2} at 174 kW around the center of the plasma. The optimal hydrogen filling pressure ranged around 0.13 Pa- 0.4 Pa for the positive ions. Ion beam extraction with a single hole ({phi} 0.5 cm) extractor has been studied systematically. A maximum H{sup -} ion beam current density of 1.6 mA/cm{sup 2} was obtained preliminarily. It was confirmed that the plasma profile was controllable by both the number and configuration of the antennas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MEASUREMENT AND CALCULATION OF ABSOLUTE SINGLE AND MULTIPLE CHARGE EXCHANGE CROSS SECTIONS FOR Fe {sup q} {sup +} IONS IMPACTING H{sub 2}O

Charge exchange (CE) plays a fundamental role in the collisions of solar- and stellar-wind ions with lunar and planetary exospheres, comets, and circumstellar clouds. Reported herein are absolute cross sections for single, double, triple, and quadruple CE of Fe {sup q} {sup +} (q = 5-13) ions with H{sub 2}O at a collision energy of 7q keV. One measured value of the pentuple CE is also given for Fe {sup 9} {sup +} ions. An electron cyclotron resonance ion source is used to provide currents of the highly charged Fe ions. Absolute data are derived from knowledge of the target gas pressure, target path length, and incident and charge-exchanged ion currents. Experimental cross sections are compared with new results of the n-electron classical trajectory Monte Carlo approximation. The radiative and non-radiative cascades following electron transfers are approximated using scaled hydrogenic transition probabilities and scaled Auger rates. Also given are estimates of cross sections for single capture, and multiple capture followed by autoionization, as derived from the extended overbarrier model. These estimates are based on new theoretical calculations of the vertical ionization potentials of H{sub 2}O up to H{sub 2}O{sup 10+}.

74 ATOMIC AND MOLECULAR PHYSICS↗

A close-coupling multi-antenna type radio frequency driven ion source

A newly close coupling multi-antenna type radio frequency driven ion source is tested for the purpose of essentially improving plasma coupling on the basis of our old type ion source, which reuses a NNBI (negative ion source for neutral beam injection) ion source used in 1/5th scale of the Large Helical Device NNBI. The ion source and the antenna structure are described, and the efficient plasma production in terms of the positive ion saturation current (the current density) is studied. The source is made of a metal-walled plasma chamber which is desirable from the point of view of the structural toughness for fusion and industrial application, etc. At around 160 kW of rf input power, the ion saturation current density successfully reaches the 5 A/cm{sup 2} level with a gas pressure of 0.6-2 Pa in hydrogen for 10 ms pulse duration. The rf power efficiency of the plasma production with a close coupling configuration of the antenna is improved substantially compared to that with the previous antenna unit in the old type ion source. The power efficiency is assessed as competing with that of other types of sources.

43 PARTICLE ACCELERATORS↗

Thin Current Sheets of Sub-Ion Scales Observed by MAVEN in the Martian Magnetotail

Current sheets (CSs) play a crucial role in the storage and conversion of magnetic energy in planetary magnetotails. Using high‐resolution magnetic field data from MAVEN spacecraft, we report the existence of super thin current sheets (STCSs) in the Martian magnetotail. The typical half‐thickness of the STCSs is ~5 km, and it is much less than the gyroradius of thermal protons (ρp). The STCSs are embedded into a thicker sheet with L ≥ ρp forming a multiscale current configuration. The formation of STCS does not depend on ion composition, but it is controlled by the small value of the normal component of the magnetic field at the neutral plane (BN). A number of the observed multiscale CSs are located in the parametric map close to the tearing‐unstable domain, and thus, the inner STCS can provide an additional free energy to excite ion tearing mode in the Martian magnetotail.

Martian↗

Lower hybrid drift instability at the inner edge of the ring current

Excitation of electrostatic waves around and above the lower hybrid frequency at the inner edge of the ring current is investigated. The model consists of cold plasmaspheric ions; hot, dilute, inhomogeneous ring current ions; and cold charge neutralizing electrons. It is shown that in the presence of a sufficiently large density gradient the coupling of the lower hybrid with the drift cyclotron harmonic mode destabilizes the plasma. Unstable interactions also occur at higher cyclotron harmonics when the lower hybrid is replaced by an ion Bernstein mode. Additional power at frequencies above the lower hybrid frequency is attributed to the thermal enhancement by the hot ring current ions, which increases with their density gradient. Particle simulations are conducted, and comparison to AMPTE data is discussed.

Roth, I.↗

"Ion" B-Dot and Faraday Cup Results Located Inside The Cathode Knob Of The Self Magnetic Pinch (Smp) Diode (A New Diagnostic For Diode Behavior?)

This paper describes our effort to measure the back-streaming ions emitted from the target x-ray convertor and thus estimate the ion contribution to the A-K gap bipolar current flow. Knowing the ion contribution is quite important in order to calculate the expected x-ray dose and compare it with the actual measurements. Our plans were first to measure the total ion current using B-dot monitors, Rogowski coils, and Faraday cups and then to utilize filtered Faraday cups and time of flight techniques to identify and measure the various ionic species. The kinetic energy (velocities) of the ions should help evaluate the actual voltage applied at the anode-cathode (A-K) gap. LSP simulations found that the most prominent ions are protons and carbon single plus (C+). For an 8-MV A-K voltage, the estimated proton current back-streaming through an 1 cm in diameter hollow cathode tip was on the average 3 kA and the carbon current 0.7 kA. Since only a small fraction of the ions will make it through the cylindrical aperture, the corresponding total currents were calculated to be respectively 25kA for proton and 7 kA for carbon ions, a quite substantial contribution to the total bipolar beam current. Hence, approximately only 10% of the total back-streaming ionic currents could make it through the hollow cathode tip aperture. Unfortunately the diagnostic cables connecting the Faraday cup and the B-dot monitors to the screen room scopes experienced a large amount of charge pick-up that obliterated our effort to directly measure those relatively small currents. However, we succeeded in measuring those currents indirectly with activation techniques [Contribution of the back-streaming ions to the self-magnetic pinch (SMP) diode Current., M. G. Mazarakis, M. G. Mazarakis, M. E. Cuneo, S. D. Fournier, M. D. Johnston, M. L. Kiefer, J. J. Leckbee, D. S. Nielsen, B.V.Oliver, M. E. Sceiford, S. C. Simpson, T. J. Renk, C. L. Ruiz, T. J. Webb, and D. Ziska. Subitted for publication.]. In the following sections we present some typical cable pick-up results and also our efforts to verify that the observed “current” scope traces were indeed not ion currents but instead cable charge pic-up. Interestingly enough we also discovered that the appearance of those “currents” are in synchronism with the A-K gap impedance variation (decrease) and the MITL sheath current re-trapping. Hence those B-dots or Faraday cups could be utilized as diode behavior diagnostics.

Mazarakis, Michael G.↗

Energization of Ions in near-Earth current sheet disruptions

In this study we examine observations made by AMPTE/CCE of energetic ion bursts during seven substorm periods when the satellite was located near the neutral sheet, and CCE observed the disruption cross-tail current in situ. We compare ion observations to analytic calculations of particle acceleration. We find that the acceleration region size, which we assume to be essentially the current disruption region, to be on the order of 1 R(sub E). Events exhibiting weak acceleration had either relatively small acceleration regions (apparently associated with pseudobreakup activity on the ground) or relatively small changes in the local magnetic field (suggesting that the magnitude of the local current disruption region was limited). These results add additional support for the view that the particle bursts observed during turbulent current sheet disruptions are due to inductive acceleration of ions.

Taktakishvili, A.↗

Forty years of surface plasma source development

The cesiation effect, a significant enhancement of negative ion emission from a gas discharge with decrease of co-extracted electron current below negative ion current, was observed for the first time on July 1, 1971 by placing into the discharge a compound with 1 mg of cesium. Subsequent developments of surface plasma sources (SPS) for highly efficient negative ion production caused by the interaction of plasma particles with electrodes on which the adsorbed cesium reduced the surface work function are described. In the last 40 years, the intensity of negative ion beams has increased by cesiation up to 10{sup 4} times from 3 mA to tens of amperes. Here, the main attention is concentrated on earlier SPS developments because recent results are well known and widely available.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Can we estimate plasma density in ICP driver through electrical parameters in RF circuit?

To avoid regular maintenance, invasive plasma diagnostics with probes are not included in the inductively coupled plasma (ICP) based ITER Neutral Beam (NB) source design. Even non-invasive probes like optical emission spectroscopic diagnostics are also not included in the present ITER NB design due to overall system design and interface issues. As a result, negative ion beam current through the extraction system in the ITER NB negative ion source is the only measurement which indicates plasma condition inside the ion source. However, beam current not only depends on the plasma condition near the extraction region but also on the perveance condition of the ion extractor system and negative ion stripping. Nevertheless, inductively coupled plasma production region (RF driver region) is placed at distance (∼ 30cm) from the extraction region. Due to that, some uncertainties are expected to be involved if one tries to link beam current with plasma properties inside the RF driver. Plasma characterization in source RF driver region is utmost necessary to maintain the optimum condition for source operation. In this paper, a method of plasma density estimation is described, based on density dependent plasma load calculation.

43 PARTICLE ACCELERATORS↗