Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Robust metal-ceramic coaxial cable sensors for distributed temperature monitoring in fossil energy power systems

The project aims to develop a new type of low cost, robust metal-ceramic coaxial cable (MCCC) Fabry-Pérot interferometer (FPI) sensor and demonstrate the capability of cascading a series of FPI sensing points in a single MCCC for real-time distributed monitoring of temperature up to 1000°C. The technical accomplishments of this project include: (i) development of metal and ceramic materials for fabricating the MCCC suitable for use in high temperature (up to 1000oC) fossil fuel, (ii) design, construction and test of single point MCCC-FPI sensors for high temperature measurement at deviation within ±2.7%, (iv) demonstration of the MCCC-FPI sensors for real-time distributed temperature measurement with desired sensitivity, spatial resolution, stability, and response speed that are important to practical applications, and (v) development of a novel MCCC-FPI sensor platform for measuring high frequency dielectric constants for solids and liquids as function of temperature. Single point MCCC-FPI sensors are fabricated based on the FPI parameters, including the relationship between reflector width and reflectance as well as the inter-reflector distance for a FPI, estimated by model calculations. MCCC-FPI sensors have been made using insulators of packed ceramic powders, ceramic tubes, and air or inert gases; outer conductors of various metal tubes; inner conductors of wires of the same metal materials as the tubes used; and reflectors of dense ceramic discs, casted ceramic discs and air gaps. The insulator, conductor and reflector materials are investigated for their thermal, chemical, and structural stabilities under temperatures up to 1000°C in simulated coal-derived syngas. Based on the experimental findings, alumina tube and discs, and stainless steel tube and wire are selected for reflector, insulator and outer and inner conductors, respectively. Air or inert gases are found to be useful for reflectors (in the form of narrow groves) or insulators (in the form of empty chamber cavity between ceramic discs) in construction of MCCC-FPI sensors. Single point MCCC-FPI sensors have been fabricated using stainless steel as conductors, dense α-alumina tubes as dielectric insulators, and two air gaps in the insulator as reflectors. The MCCC-FPI sensor with air gap reflectors has been demonstrated for measuring temperature between 200 and 500°C using microwave as sensing signal in a frequency range of 2 – 8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of a selected resonant peak of the microwave interferogram reflected from the pair of air gap reflectors. The MCCC-FPI sensor exhibited excellent linear temperature-dependence for Δƒ, good accuracy (deviation ±2.7%), and reasonable response speed (<180 s for stabilization). Thermal drifting of the sensing signal was also rather minimal for the MCCC-FPI sensors after operating for more than one week at around 500oC. MCCC-FPI sensors with each containing 2 or 3 pairs of reflectors (i.e. 2 or 3 FPIs in a single cable) have been fabricated and demonstrated for distributed temperature measurement between 250 and 550°C in a microwave frequency range of 3-6 GHz. The measurement is achieved by monitoring the frequency shift of a selected resonant peak of the reflected microwave interferogram, which is obtained by the join-time-domain signal processing method. The results demonstrate that the FPI sensing points in both the three-point and two-point MCCC sensors can measure distributed high temperature with good reproducibility and consistency in multiple runs of measurement tests. The sensor signal displays excellent linear dependence between temperature and the corresponding frequency shift. The 2-point and 3-point MCCC-FPI sensors also exhibit fast response to environmental temperature changes. A three-point MCCC-FPI sensor has been further examined for temperature measurement up to 1000°C for multiple heating-cooling cycles and the results prove that the sensor is suitable for distributed temperature measurement up to 1000°C. MCCC-FPI sensors with more than 4 FPIs point in a single line are made in two structures: the first uses alumina tube as insulation and air gaps as reflectors; and the second uses air chamber as insulation and complete circular alumina discs (2 mm-thick) as reflectors. MCCC-FPIs in neither of the two structures are able to exceed four FPIs in a cable because the reflections from the FPIs are too strong for the microwave to transmit through >4 FPIs over a long distance. Specially shaped alumina discs made by removing parts of the circular discs are found to decrease the microwave reflectance because of reduced reflection areas. However, the smallest reflectance (in terms of percentage of the incident signal) obtained in this work is as high as 7.5%, which is still too large to construct more than 10 FPIs in a single MCCC. Nevertheless, the feasibility of the proposed multipoint MCCC-FPI has been demonstrated using air insulation and 2 mm-thick low-ε r Teflon discs as reflectors on a 2 m-long cable containing 10 FPIs (with reflectance <5% on each FPI). These results indicate that the contrast of dielectric constant between the insulation and reflector has a more significant impact on the reflectance. Thus, future research efforts should also be directed to developing ceramic materials (dense or porous) with low dielectric constant values which, when used as insulation or reflector, can realize large numbers of FPIs in a single cable over a long distance. To assist the development of high temperature dielectric materials, a novel MCCC-FPI sensor platform is developed and successfully demonstrated for measuring high frequency dielectric constants for fluids, packed dielectric solids, and ceramic tube materials and determining ε r dependencies on temperature and chemical composition, etc..

36 MATERIALS SCIENCE↗

Fabry-Perot interferometers as narrow band optical filters.

We have constructed solid Fabry-Perot narrow-band filters that can be used in systems having one arc second or better resolution. Our filters operate at H-alpha, have a three-inch aperture, and typical transmission of 70 per cent. However, the same technology can be applied to construction of filters as narrow as 0.05 A at any wavelength from 4200 to 11000 A.

Title, A. M.↗

Ultraviolet-excimer laser-based incoherent Doppler lidar system

The topics covered include the following: principles of Doppler measurements, laser backscatter, eye safety, demonstration concepts, the wavelength-meter, the interferometer detector, return signal model, and comparison of incoherent and coherent lidars.

Mcdermid, I. Stuart↗

Interferometer applications of VHF radars, part 3.6A

Using a spaced antenna setup of a VHF radar, the spatial distribution of amplitudes and phases of the radar echoes from the troposphere, stratosphere and mesosphere can be measured. Combining in a suitable analysis procedure the complex digital samples from the different receiving antennas is consistent with the radar interferometer method. In addition to the well-known parameters measured with the commonly applied Doppler and drifts methods, i.e., reflectivity and mean fluctuation velocity, the interferometer technique allows to measure the regular spectrum of the returns. This technique, which was first applied with the spaced antenna system of the SOUSY-VHF-Radar in W. Germany, as well as some first examples of results are described here. These comprise the measurements of the horizontal and vertical velocities of the mean flow as well as of turbulence structures, the aspect sensitivity and the tilt of layers from which the baroclinicity can be estimated. Particularly, results of interferometer measurements of the vertical and horizontal phase velocities and wavelengths of gravity waves in the stratosphere are displayed. The latter results are also discussed in terms of the generation and propagation of these waves.

Rottger, J.↗

Quantum-dot-induced phase shift in a pillar microcavity

We perform high-resolution reflection spectroscopy of a quantum dot resonantly coupled to a pillar microcavity. We show the change in reflectivity as the quantum dot is tuned through the cavity resonance and measure the quantum-dot-induced phase shift using an ultrastable interferometer. The macroscopic phase shift we measure could be extended to the study of charged quantum dot pillar microcavity systems, where it could be exploited to realize a high-efficiency spin photon interface for hybrid quantum information schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Michelson Stellar Interferometer Error Budget for Triple Triple-Satellite Configuration

This report presents the results of a study of the instrumentation tolerances for a conventional style Michelson stellar interferometer (MSI). The method used to determine the tolerances was to determine the change, due to the instrument errors, in the measured fringe visibility and phase relative to the ideal values. The ideal values are those values of fringe visibility and phase that would be measured by a perfect MSI and are attributable solely to the object being detected. Once the functional relationship for changes in visibility and phase as a function of various instrument errors is understood it is then possible to set limits on the instrument errors in order to ensure that the measured visibility and phase are different from the ideal values by no more than some specified amount. This was done as part of this study. The limits we obtained are based on a visibility error of no more than 1% and a phase error of no more than 0.063 radians (this comes from 1% of 2(pi) radians). The choice of these 1% limits is supported in the literture. The approach employed in the study involved the use of ASAP (Advanced System Analysis Program) software provided by Breault Research Organization, Inc., in conjunction with parallel analytical calculations. The interferometer accepts object radiation into two separate arms each consisting of an outer mirror, an inner mirror, a delay line (made up of two moveable mirrors and two static mirrors), and a 10:1 afocal reduction telescope. The radiation coming out of both arms is incident on a slit plane which is opaque with two openings (slits). One of the two slits is centered directly under one of the two arms of the interferometer and the other slit is centered directly under the other arm. The slit plane is followed immediately by an ideal combining lens which images the radiation in the fringe plane (also referred to subsequently as the detector plane).

Marathay, Arvind S.↗

THE FIRST VERY LONG BASELINE INTERFEROMETRIC SETI EXPERIMENT

The first Search for Extra-Terrestrial Intelligence (SETI) conducted with very long baseline interferometry (VLBI) is presented. By consideration of the basic principles of interferometry, we show that VLBI is efficient at discriminating between SETI signals and human generated radio frequency interference (RFI). The target for this study was the star Gliese 581, thought to have two planets within its habitable zone. On 2007 June 19, Gliese 581 was observed for 8 hr at 1230-1544 MHz with the Australian Long Baseline Array. The data set was searched for signals appearing on all interferometer baselines above five times the noise limit. A total of 222 potential SETI signals were detected and by using automated data analysis techniques were ruled out as originating from the Gliese 581 system. From our results we place an upper limit of 7 MW Hz{sup -1} on the power output of any isotropic emitter located in the Gliese 581 system within this frequency range. This study shows that VLBI is ideal for targeted SETI including follow-up observations. The techniques presented are equally applicable to next-generation interferometers, such as the long baselines of the Square Kilometre Array.

79 ASTRONOMY AND ASTROPHYSICS↗

SIM-PlanetQuest: Progress Report

SIM-PlanetQuest is a NASA astrophysics mission that is implementing the National Research Counsel's recommended Astrometric Interferometry Mission (AIM) to develop the first, in-space, optical, long-baseline Michelson Stellar Interferometer for performing micro-arcsecond-level astrometry. This level of astrometric precision will enable characterization of planetary systems around nearby stars and enable a number of key investigations in astrophysics including calibration of the cosmological distance scale, stellar and galactic structure and evolution, and dark matter/energy distribution. This paper provides an update on the SIM-PlanetQuest Mission covering the results of the 2005 mission redesign and the recent completion of the last in a series of technology "gates." The SIM-PlanetQuest mission redesign was directed by NASA to recover eroded mass and power margins and to meet specific implementation cost targets. The resulting mission redesign met all redesign objectives with minimal impact to mission science performance. This paper provides the mission redesign objectives and describes the resulting mission and system design including changes in science capability. SIM-PlanetQuest also completed the last of eight major technology development gates that were established in 2001 by NASA, completing the enabling technology development. The technology development program, the last gate, and its significance to the project's flight verification and validation (V&V) approach are briefly described (covered in more detail in a separate paper at this conference). An update on project programmatic status and plans is also provided.

astrometry↗

THE REVISED ORBIT OF THE {delta} Sco SYSTEM

In anticipation of the possible collision between a circumstellar disk and the secondary star in the highly eccentric binary system {delta} Scorpii, high angular resolution interferometric observations have been acquired, aimed at revising the binary parameters. The Navy Prototype Optical Interferometer was used to spatially resolve the binary components in 2000 and over a period between 2005 and 2010. The interferometric observations are used to obtain the angular separations and orientations of the two stellar components at all epochs for which data have been obtained, including 2005 and 2006, for which, based on previous studies, there was some uncertainty as to if the signature of binarity can be clearly detected. The results of this study represent the most complete and accurate coverage of the binary orbit of this system to date and allow for the revised timing of the upcoming periastron passage that will occur in 2011 to be obtained.

79 ASTRONOMY AND ASTROPHYSICS↗

Collinear interferometer with variable delay for carrier-envelope offset frequency measurement

We demonstrate a novel scheme for measuring the carrier-envelope offset frequency in a femtosecond optical frequency comb. Our method is based on a common-path interferometer with a calcite Babinet-Soleil compensator employed to control the delay between the two interfering beams of pulses. The large delay range (up to 8 ps) of our device is sufficient for systems that rely on spectral broadening in microstructured fibers. We show an experimental proof that the stability of a common-path arrangement is superior to that of the standard interferometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

TRUNCATED DISKS IN TW Hya ASSOCIATION MULTIPLE STAR SYSTEMS

We present high angular resolution (down to 0.''3 {approx} 13 AU in diameter) Submillimeter Array observations of the 880 {mu}m (340 GHz) thermal continuum emission from circumstellar dust disks in the nearby HD 98800 and Hen 3-600 multiple star systems. In both cases, the dust emission is resolved and localized around one stellar component-the HD 98800B and Hen 3-600A spectroscopic binaries-with no evidence for circum-system material. Using two-dimensional Monte Carlo radiative transfer calculations, we compare the Submillimeter Array interferometer visibilities and broadband spectral energy distributions with truncated disk models to empirically locate the inner and outer edges of both disks. The HD 98800B disk appears to be aligned with the spectroscopic binary orbit, is internally truncated at a radius of 3.5 AU, and extends to only 10-15 AU from the central stars. The Hen 3-600A disk is slightly larger, with an inner edge at {approx}1 AU and an outer radius of 15-25 AU. These inferred disk structures compare favorably with theoretical predictions of their truncation due to tidal interactions with the stellar companions.

79 ASTRONOMY AND ASTROPHYSICS↗

On the limitations of the concept of space frequency equivalence

A narrow-band correlation interferometer using directive (large) antennas is equivalent to a wideband correlation interferometer employing isotropic (small) antennas. This concept of space frequency equivalence, due to Kock and Stone, is reexamined and is shown to hold exactly only for the mean or expected values of the correlation interferometer outputs. If their variances are considered, the equivalence disappears, with the variance fo the wideband system always equal to or greater than that of the narrow-band system.

Macphie, R. H.↗

Millimeter-wave Imaging Radiometer (MIR) data processing and development of water vapor retrieval algorithms

This document describes the progress of the task of the Millimeter-wave Imaging Radiometer (MIR) data processing and the development of water vapor retrieval algorithms, for the second six-month performing period. Aircraft MIR data from two 1995 field experiments were collected and processed with a revised data processing software. Two revised versions of water vapor retrieval algorithm were developed, one for the execution of retrieval on a supercomputer platform, and one for using pressure as the vertical coordinate. Two implementations of incorporating products from other sensors into the water vapor retrieval system, one from the Special Sensor Microwave Imager (SSM/I), the other from the High-resolution Interferometer Sounder (HIS). Water vapor retrievals were performed for both airborne MIR data and spaceborne SSM/T-2 data, during field experiments of TOGA/COARE, CAMEX-1, and CAMEX-2. The climatology of water vapor during TOGA/COARE was examined by SSM/T-2 soundings and conventional rawinsonde.

Chang, L. Aron↗

In-flight Far-Infrared Performance of the CIRS Instrument on Cassini

The Composite Infrared Spectrometer (CIRS) on-board Cassini consists of two interferometers: a conventional Michelson for the mid-infrared; and a Martin-Puplett type in the far-infrared employing wire grid polarizers to split, recombine and analyze the radiation. The far-IR focal plane (FP1) assembly uses two thermopile detectors to measure the final transmitted and reflected beams at the polarizer-analyzer: if one fails, the interferometer can still operate, albeit with a lower efficiency. The combined effect is for good response from 10 to 300/cm, and declining response to 600/cm. This paper will examine in-flight performance of the far-IR interferometer, including NESR and response. Regular noise spikes, resulting from pickup from other electrical sub-systems has been found on the CIRS interferograms, and the removal of these effects is discussed. The radiometric calibration is described, and then we show how the calibration was applied to science data taken during the Jupiter flyby of December 2000. Finally, we discuss signal-to-noise on the calibrated spectra, emphasizing limitations of the current instrument and the potential for improvement in future missions.

Nixon, Conor A.↗

ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements

ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.

Honne, A.↗

Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

Pugel, Diane↗