Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Zirkonkarbid ermöglicht verkokungsresistente Methan‐Trockenreformierung auf Nickel‐Zirkon‐Katalysatoren

Abstract Graphitische Ablagerungen lösen sich in Ni 0 ‐Nanopartikeln auf, um rezyklierte CH 4 ‐Adsorptionsstellen und oberflächennahe/gelöste C‐Atome bereitzustellen, die zur Ni 0 /ZrO 2 ‐Grenzfläche wandern und eine lokale Zr x C y ‐Bildung induzieren. Die daraus resultierenden sauerstoffarmen karbidischen Phasengrenzflächen unterstützen die Kinetik der CO 2 ‐Aktivierung zu CO(g). Dieser Grenzflächen‐Karbid‐Mechanismus ermöglicht einen verstärkten Übertritt von Kohlenstoff auf den ZrO 2 ‐Träger und stellt einen alternativen Weg der Katalysatorregeneration im Vergleich zum umgekehrten Sauerstoffübertritt auf Ni/CeZr x O y ‐Katalysatoren dar. Er ist daher eher auf Trägern mit begrenzter Sauerstoffspeicher‐ bzw. Austausch‐Kinetik, aber signifikanter karbothermischer Reduzierbarkeit, wahrscheinlich.

Haug, Leander↗

Modifikation eines Cu‐Pd‐Schaufelrad‐Metall‐Organischen Gerüsts für die selektive CO 2 ‐Elektroreduktion

Abstract Die Optimierung der Bindungsenergie zwischen dem Intermediat und dem aktiven Zentrum ist ein entscheidender Faktor, um die katalytische Produktselektivität und Aktivität bei der elektrochemischen Kohlendioxidreduktion (CO 2 RR) zu steuern. Es ist bekannt, dass Kupferatome als aktive Zentren CO 2 zu Kohlenwasserstoffen und Sauerstoffverbindungen reduzieren, jedoch unter schlechter Produktselektivität leiden, da mehrere Intermediate nur moderate Bindungsenergien aufweisen. Hier berichten wir über eine Ionenaustauschstrategie zur Konstruktion von Cu−Pd‐Schaufelrad‐Dimeren innerhalb von Cu‐basierten metallorganischen Gerüsten (MOFs), [Cu 3‐x Pdx(BTC) 2 ] (BTC=1,3,5‐Benzoltricarbonsäure), ohne die strukturellen Eigenschaften des MOFs zu verändern. Im Vergleich zum reinen Cu‐MOF ([Cu 3 (BTC) 2 ], HKUST‐1) verlagert der Cu−Pd‐MOF die Produkte der CO 2 ‐Elektroreduktion von einer Vielzahl chemischer Spezies hin zu einer selektiven CO‐Erzeugung. Eine in situ‐Röntgenabsorptions‐Feinstrukturanalyse der Oxidationsstufe des Katalysators und der lokalen Geometrie, kombiniert mit theoretischen Berechnungen, zeigt, dass die Einfügung von Pd in die Knotenpunkte der Cu‐Schaufelradstruktur des MOFs die Adsorption des Schlüsselintermediats COOH* am Cu‐Zentrum fördert. Dies ermöglicht CO‐selektive katalytische Mechanismen und verbessert somit unser Verständnis über das Zusammenspiel von Struktur und Aktivität bei der elektrochemischen CO 2 ‐Reduktion unter Verwendung molekularer Katalysatoren.

Zhang, Ruirui↗

A Boosted Critical Temperature of 166 K in Superconducting D 3 S Synthesized from Elemental Sulfur and Hydrogen

The discovery of superconductivity in H 3 S at 203 K marked an advance towards room-temperature superconductivity and demonstrated the potential of H-dominated compounds to possess a high critical temperature (T c ). There have been numerous reports of the H-S system over the last five years, but important questions remain unanswered. It is crucial to verify whether the Tc was determined correctly for samples prepared from compressed H 2 S, since they are inevitably contaminated with H-depleted byproducts. Here, we prepare stoichiometric H 3 S by direct in situ synthesis from elemental S and excess H 2 . The Im$_\bar{3}$ m phase of D 3 S samples exhibits a T c significantly higher than previously reported values (ca. 150 K), reaching a maximum T c of 166 K at 157 GPa. Furthermore, we confirm that the sharp decrease in T c below 150 GPa is accompanied by continuous rhombohedral structural distortions and demonstrate that the Cccm phase is nonmetallic, with molecular H 2 units in the crystal structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New perspective on iron-ligand vibrations of oxyheme complexes.

We report our studies of the vibrational dynamics of iron for three imidazole-ligated oxyheme derivatives that mimic the active sites of histidine-ligated heme proteins complexed with dioxygen. The experimental vibrational data are obtained from nuclear resonance vibrational spectroscopy (NRVS) measurements conducted on both powder samples and oriented single crystals, and which includes several in-plane (ip) and out-of-plane (oop) measurements. Vibrational spectral assignments have been made through a combination of the oriented sample spectra and predictions based on density functional theory (DFT) calculations. The two Fe-O{sub 2} modes that have been previously observed by resonance Raman spectroscopy in heme proteins are clearly shown to be very strongly mixed and are not simply either a bending or stretching mode. In addition, a third Fe-O{sub 2} mode, not previously reported, has been identified. The long-sought Fe-Im stretch, not observed in resonance Raman spectra, has been identified and compared with the frequencies observed for the analogous CO and NO species. The studies also suggest that the in-plane iron motion is anisotropic and is controlled by the orientation of the Fe-O{sub 2} group and not sensitive to the in-plane Fe-N{sub p} bonds and/or imidazole orientations.

59 BASIC BIOLOGICAL SCIENCES↗

Scaling the SIESTA Magnetohydrodynamics Equilibrium Code

We report the results of a scaling effort that increases both the speed and resolution of the SIESTA magnetohydrodynamic equilibrium code. SIESTA is capable of computing three-dimensional plasma equilibria with magnetic islands at high spatial resolutions for toroidally confined plasmas. Starting with a small-scale parallel im- plementation, we identified scale-dependent bottlenecks of the code and developed scalable alternatives for each performance-significant functionality, cumulatively increasing the runtime speed and scalability with the number of processors. The net outcome is an improvement in speed by over ten-fold, utilizing a few thousand processors, en- abling SIESTA to simulate high spatial-resolution scenarios in under an hour for the first time.

Seal, Sudip K↗

Photophysical and Time‐resolved Infrared Properties of Long‐Lived Rhenium(I) 4,5‐Diazafluorene Tricarbonyl Chromophores

This report investigates the synthesis, structural characterization, fundamental molecular photophysics, electrochemistry, UV-Vis spectroelectrochemistry, and time-resolved infrared spectroscopic properties of eight [fac-Re(dafR)(CO) 3 L] 0/+ complexes, where R=ethyl [(dedaf); 1, 3, 5, 7] or H [(dafH); 2, 4, 6, 8] and L=Cl− (1, 2), imidazole [(Im); 3, 4], 4-ethylpyridine [(4-Etpy); 5, 6], or pyridine [(py); 7, 8]. Universally, 1–8 yield higher energy photoluminescence (PL) emission bands and higher PL quantum yields (up to 53 %) than the classic 2,2’-bipyridine (bpy) and 1,10-phenanthroline (phen) ligated Re(I) tricarbonyl complexes. The excited state lifetimes of 1–8 lie between those corresponding to the bpy and phen derivatives, ranging from 120 and 1300 ns at room temperature. Combinations of reductive UV-Vis spectroelectrochemistry, transient absorption spectroscopy, and time-resolved infrared spectroscopy consistently assigned the lowest excited states in 1–8 being of metal-to-ligand charge transfer (MLCT) character. These new ReI MLCT chromophores follow classic energy gap law behavior and possess the characteristics necessary for serving as valuable photosensitizers suitable to energize excited state electron and energy transfer photochemistry.

Charge transfer↗

Structure and Dynamics of Imidazolium in an Ionic Liquid-PEGDA Iongel via IR, 2D-IR, and NMR Spectroscopy

Fourier transform infrared (FTIR) absorption spectroscopy, ultrafast two-dimensional infrared (2D-IR) spectroscopy, nuclear magnetic resonance (NMR) spectroscopy, and density functional theory (DFT) calculations show that, in iongels composed of 1-ethyl-3-methylimidazolium bis(trifluoromethyl\-sulfonyl)imide ([C 2 C 1 Im][Tf 2 N]}) and cross-linked poly(ethylene glycol)diacrylate (cl-PEGDA), imidazolium cations solvate PEGDA chains in tight and loose complexes. H/D isotope substitution at the 2-position of the imidazolium ring simplifies the CH-stretching vibrational bands. Tight complexes are characterized by stronger, directional hydrogen bonding interactions between the 2-position of the imidazolium ring and the ethereal oxygens. The loose complexes resemble bulk ionic liquid (IL) non-specifically perturbed by the PEGDA chains.

ionic liquids, carbon dioxide, cross-linked PEGDA,↗

Strategy for Extending the Stability of Bio‐oil‐Derived Phenolic Oligomers by Mild Hydrotreatment with Ionic‐Liquid‐Stabilized Nanoparticles

Abstract The development of catalytic transformations and processes is essential to utilize bio‐oil and lignin derivatives. Metal nanoparticles (M‐NPs) stabilized in ionic liquids (ILs) are promising for the catalytic hydrotreatment of bio‐oil because the properties of the catalyst system can be customized by combining the appropriate IL and metal nanoparticles. Herein, we demonstrate an experimental approach to stabilize lignin‐derived phenolics isolated from bio‐oil with ruthenium NPs stabilized by an ionic copolymer in 1‐ethyl‐3‐methylimidazolium acetate ([C 2 C 1 Im][OAc]). The mild hydrotreatment of phenolic oligomers (POs) was performed with the synthesized M‐NP catalyst at 100 °C for 6 h. Hydrotreatment of the POs resulted in enhanced thermal stability of the POs by as much as a factor of three, as determined by the aging index and by reducing reactive functionalities, which was also confirmed by NMR spectroscopy and GC analysis. The results support our hypothesis that M‐NPs stabilized in ILs can effectively stabilize POs under mild conditions, which could be applicable to any lignin‐derived phenolic.

Kim, Kwang Ho↗

Enhancing CO 2 Transport Across a PEEK‐Ionene Membrane and Water‐Lean Solvent Interface

Abstract Efficient direct air capture (DAC) of CO 2 will require strategies to deal with the relatively low concentration in the atmosphere. One such strategy is to employ the combination of a CO 2 ‐selective membrane coupled with a CO 2 capture solvent acting as a draw solution. Here, the interactions between a leading water‐lean carbon‐capture solvent, a polyether ether ketone (PEEK)‐ionene membrane, CO 2 , and combinations were probed using advanced NMR techniques coupled with advanced simulations. We identify the speciation and dynamics of the solvent, membrane, and CO 2 , presenting spectroscopic evidence of CO 2 diffusion through benzylic regions within the PEEK‐ionene membrane, not spaces in the ionic lattice as expected. Our results demonstrate that water‐lean capture solvents provide a thermodynamic and kinetic funnel to draw CO 2 from the air through the membrane and into the bulk solvent, thus enhancing the performance of the membrane. The reaction between the carbon‐capture solvent and CO 2 produces carbamic acid, disrupting interactions between the imidazolium (Im + ) cations and the bistriflimide anions within the PEEK‐ionene membrane, thereby creating structural changes through which CO 2 can diffuse more readily. Consequently, this restructuring results in CO 2 diffusion at the interface that is faster than CO 2 diffusion in the bulk carbon‐capture solvent.

Walter, Eric D.↗

Validation of (not-historical) large-event near-fault ground-motion simulations for use in civil engineering applications

Ground-motion simulations generated from physics-based wave propagation models are gaining increasing interest in the engineering community for their potential to inform the performance-based design and assessment of infrastructure residing in active seismic areas. A key prerequisite before the ground-motion simulations can be used with confidence for application in engineering domains is their comprehensive and rigorous investigation and validation. This article provides a four-step methodology and acceptance criteria to assess the reliability of simulated ground motions of not historical events, which includes (1) the selection of a population of real records consistent with the simulated scenarios, (2) the comparison of the distribution of Intensity Measures (IMs) from the simulated records, real records, and Ground-Motion Prediction Equations (GMPEs), (3) the comparison of the distribution of simple proxies for building response, and (4) the comparison of the distribution of Engineering Demand Parameters (EDPs) for a realistic model of a structure. Specific focus is laid on near-field ground motions (<10km) from large earthquakes (M w 7), for which the database of real records for potential use in engineering applications is severely limited. The methodology is demonstrated through comparison of (2490) near-field synthetic records with 5 Hz resolution generated from the Pitarka et al (2019) kinematic rupture model with a population of (38) pulse-like near-field real records from multiple events and, when applicable, with NGA-W2 GMPEs. Lastly, the proposed procedure provides an effective method for informing and advancing the science needed to generate realistic ground-motion simulations, and for building confidence in their use in engineering domains.

42 ENGINEERING↗

Identification of Hip BMD Loss and Fracture Risk Markers Through Population-Based Serum Proteomics: HIP BMD LOSS & FRACTURE RISK MARKERS BY POPULATION-BASED SERUM PROTEOMICS

Accelerated bone loss significantly increases the risk of osteoporosis and fracture. The mechanisms underlying bone loss remain incompletely understood, and there are few available biomarkers. We utilized a novel proteomics approach to identify serum peptides and proteins associated with bone loss in 1967 older men who were randomly chosen from the Osteoporotic Fracture in Men Study (MrOS study) (age ≥ 65 yrs). Men had 2-3 measures of femoral neck BMD over an average follow-up of 4.6 years. Change in BMD was estimated and then categorized into three groups: maintained BMD (n=453), expected loss (n=1185) and accelerated loss (n=237). A liquid chromatography–ion mobility separation-mass spectrometry (LC-IMS-MS) proteomics platform was used to identify and quantify peptides from serum proteins. The whole cohort was randomly divided into discovery (N= 960) and validation (N= 915) sub-cohorts. Linear regression models and a random forest approach were used to discover differentially abundant individual peptides and a proteomic signature that distinguished individuals with accelerated bone loss from those who maintained BMD. Network analyses were performed using the MetaCore knowledgebase. We identified 12 peptides that were associated with BMD loss in both discovery (P< 0.1 FDR) and replication sub-cohorts (P<0.05). Those 12 peptides mapped to the following proteins: ALS, LYVE1, RNAS1, C2, ICOSL, C163A, C7, HEMO, CD14, CERU, CRAC1 and CD59. Meta-analysis of peptidesassociated with bone loss identified 6 additional proteins including GRP78, IGF-2, SHBG, ENPP2, IBP2 and IBP6. We also identified a proteomic signature that was predictive of BMD loss with a discriminative value similar to serum bone marker carboxy-terminal collagen crosslink peptide (CTX). Interestingly, combining the proteomic signature with CTX significantly improved the ability to discriminate men with accelerated loss. In summary, we have identified potential new biomarkers for bone loss that provide a more in depth understanding of its pathophysiology.

59 BASIC BIOLOGICAL SCIENCES↗

Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sulfur isotope analysis of microcrystalline iron sulfides using secondary ion mass spectrometry imaging: Extracting local paleo-environmental information from modern and ancient sediments

Rationale: Sulfur isotope ratio measurements of bulk sulfide from marine sediments have often been used to reconstruct environmental conditions associated with their formation. In situ microscale spot analyses by secondary ion mass spectrometry (SIMS) and laser ablation multiple-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) have been utilized for the same purpose. However, these techniques are often not suitable for studying small (≤10 μm) grains or for detecting intra-grain variability. Methods: In this work, we present a method for the physical extraction (using lithium polytungstate heavy liquid) and subsequent sulfur isotope analysis (using SIMS; CAMECA IMS 7f-GEO) of microcrystalline iron sulfides. SIMS sulfur isotope ratio measurements were made via Cs + bombardment of raster squares with sides of 20–130 μm, using an electron multiplier (EM) detector to collect counts of 32 S - and 34 S - for each pixel (128 × 128 pixel grids) for between 20 and 960 cycles. Results: The extraction procedure did not discernibly alter pyrite grain-size distributions. The apparent inter-grain variability in 34 S/ 32 S in 1–4 μm-sized pyrite and marcasite fragments from isotopically homogeneous hydrothermal crystals was ~ ±2‰ (1σ), comparable with the standard error of the mean for individual measurements (≤ ±2‰, 1σ). In contrast, grain-specific 34 S/ 32 S ratios in modern and ancient sedimentary pyrites and marcasites can have inter- and intra-grain variability >60‰. The distributions of intra-sample isotopic variability are consistent with bulk 34 S/ 32 S values. Conclusions: SIMS analyses of isolated iron sulfide grains yielded distributions that are isotopically representative of bulk 34 S/ 32 S values. Populations of iron sulfide grains from sedimentary samples record the evolution of the S-isotopic composition of pore water sulfide in their S-isotopic compositions. These data allow past local environmental conditions to be inferred.

59 BASIC BIOLOGICAL SCIENCES↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of δ 13 C analyses of individual foraminifer ( Orbulina universa ) shells by secondary ion mass spectrometry and gas source mass spectrometry

Rationale: The use of secondary ion mass spectrometry (SIMS) to perform micrometer-scale in situ carbon isotope (δ 13 C) analyses of shells of marine microfossils called planktic foraminifers holds promise to explore calcification and ecological processes. The potential of this technique, however, cannot be realized without comparison to traditional whole-shell δ 13 C values measured by gas source mass spectrometry (GSMS). Methods: Paired SIMS and GSMS δ 13 C values measured from final chamber fragments of the same shell of the planktic foraminifer Orbulina universa are compared. The SIMS–GSMS δ 13 C differences (Δ 13 C SIMS-GSMS ) were determined via paired analysis of hydrogen peroxide-cleaned fragments of modern cultured specimens and of fossil specimens from deep-sea sediments that were either untreated, sonicated, and cleaned with hydrogen peroxide or vacuum roasted. After treatment, fragments were analyzed by a CAMECA IMS 1280 SIMS instrument and either a ThermoScientific MAT-253 or a Fisons Optima isotope ratio mass spectrometer (GSMS). Results: Paired analyses of cleaned fragments of cultured specimens (n = 7) yield no SIMS–GSMS δ 13 C difference. However, paired analyses of untreated (n = 18) and cleaned (n = 12) fragments of fossil shells yield average Δ 13 C SIMS-GSMS values of 0.8‰ and 0.6‰ (±0.2‰, 2 SE), respectively, while vacuum roasting of fossil shell fragments (n = 11) removes the SIMS–GSMS δ 13 C difference. Conclusions: The noted Δ 13 C SIMS-GSMS values are most likely due to matrix effects causing sample–standard mismatch for SIMS analyses but may also be a combination of other factors such as SIMS measurement of chemically bound water. The volume of material analyzed via SIMS is ~10 5 times smaller than that analyzed by GSMS; hence, the extent to which these Δ 13 C SIMS-GSMS values represent differences in analyte or instrument factors remains unclear.

58 GEOSCIENCES↗

Ion Mobility Separations of Isomers based upon Long Path Length Structures for Lossless Ion Manipulations Combined with Mass Spectrometry

Mass spectrometry (MS)-based multi-omic measurements, including proteomics, metabolomics, lipidomics, and glycomics, are increasingly transforming our ability to characterize and understand biological systems, but, presently have limitations due to the chemical diversity and range of abundances of biomolecules in complex samples. Advances addressing these challenges increasingly are based upon the ability to quickly separate, react and otherwise manipulate sample components for analysis by MS. Here we report on a new approach using Structures for Lossless Ion Manipulations (SLIM) to enable long serpentine path ion mobility spectrometry (IMS) separations followed by MS analyses. This approach provides previously unachieved mobility biomolecule isomer separations for biomolecular species, in conjunction with more effective ion utilization, and producing a basis for the improved characterization of very small samples.

Environmental Molecular Sciences Laboratory↗

Search for anomalous couplings in the W tb vertex from the measurement of double differential angular decay rates of single top quarks produced in the t-channel with the ATLAS detector

The electroweak production and subsequent decay of single top quarks is determined by the properties of the Wtb vertex. This vertex can be described by the complex parameters of an effective Lagrangian. An analysis of angular distributions of the decay products of single top quarks produced in the t -channel constrains these parameters simultaneously. The analysis described in this paper uses 4.6 fb -1 of proton-proton collision data at √s=7 TeV collected with the ATLAS detector at the LHC. Two parameters are measured simultaneously in this analysis. The fraction f 1 of decays containing transversely polarised W bosons is measured to be 0.37 ± 0.07 (stat.⊕syst.). The phase δ - between amplitudes for transversely and longitudinally polarised W bosons recoiling against left-handed b-quarks is measured to be -0.014π ± 0.036π (stat.⊕syst.). The correlation in the measurement of these parameters is 0.15. These values result in two-dimensional limits at the 95% confidence level on the ratio of the complex coupling parameters g R and V L , yielding Re[g R /V L ] ϵ [-0.36, 0.10] and Im[g R /V L ] ϵ [-0.17, 0.23] with a correlation of 0.11. We find the results are in good agreement with the predictions of the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the strong-coupling region of SU( N ) Seiberg-Witten theory

We consider the Seiberg-Witten solution of pure N = 2 gauge theory in four dimensions, with gauge group SU(N). A simple exact series expansion for the dependence of the 2(N – 1) Seiberg-Witten periods a I (u), a DI (u) on the N – 1 Coulomb-branch moduli un is obtained around the Z 2N -symmetric point of the Coulomb branch, where all u n vanish. This generalizes earlier results for N = 2 in terms of hypergeometric functions, and for N = 3 in terms of Appell functions. Using these and other analytical results, combined with numerical computations, we explore the global structure of the Kähler potential K = 1/2Σ I Im(a¯ I a DI ), which is single valued on the Coulomb branch. Evidence is presented that K is a convex function, with a unique minimum at the Z 2N -symmetric point. Finally, we explore candidate walls of marginal stability in the vicinity of this point, and their relation to the surface of vanishing Kähler potential.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗