Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Photophysical and Time‐resolved Infrared Properties of Long‐Lived Rhenium(I) 4,5‐Diazafluorene Tricarbonyl Chromophores

This report investigates the synthesis, structural characterization, fundamental molecular photophysics, electrochemistry, UV-Vis spectroelectrochemistry, and time-resolved infrared spectroscopic properties of eight [fac-Re(dafR)(CO) 3 L] 0/+ complexes, where R=ethyl [(dedaf); 1, 3, 5, 7] or H [(dafH); 2, 4, 6, 8] and L=Cl− (1, 2), imidazole [(Im); 3, 4], 4-ethylpyridine [(4-Etpy); 5, 6], or pyridine [(py); 7, 8]. Universally, 1–8 yield higher energy photoluminescence (PL) emission bands and higher PL quantum yields (up to 53 %) than the classic 2,2’-bipyridine (bpy) and 1,10-phenanthroline (phen) ligated Re(I) tricarbonyl complexes. The excited state lifetimes of 1–8 lie between those corresponding to the bpy and phen derivatives, ranging from 120 and 1300 ns at room temperature. Combinations of reductive UV-Vis spectroelectrochemistry, transient absorption spectroscopy, and time-resolved infrared spectroscopy consistently assigned the lowest excited states in 1–8 being of metal-to-ligand charge transfer (MLCT) character. These new ReI MLCT chromophores follow classic energy gap law behavior and possess the characteristics necessary for serving as valuable photosensitizers suitable to energize excited state electron and energy transfer photochemistry.

Charge transfer↗

Structure and Dynamics of Imidazolium in an Ionic Liquid-PEGDA Iongel via IR, 2D-IR, and NMR Spectroscopy

Fourier transform infrared (FTIR) absorption spectroscopy, ultrafast two-dimensional infrared (2D-IR) spectroscopy, nuclear magnetic resonance (NMR) spectroscopy, and density functional theory (DFT) calculations show that, in iongels composed of 1-ethyl-3-methylimidazolium bis(trifluoromethyl\-sulfonyl)imide ([C 2 C 1 Im][Tf 2 N]}) and cross-linked poly(ethylene glycol)diacrylate (cl-PEGDA), imidazolium cations solvate PEGDA chains in tight and loose complexes. H/D isotope substitution at the 2-position of the imidazolium ring simplifies the CH-stretching vibrational bands. Tight complexes are characterized by stronger, directional hydrogen bonding interactions between the 2-position of the imidazolium ring and the ethereal oxygens. The loose complexes resemble bulk ionic liquid (IL) non-specifically perturbed by the PEGDA chains.

ionic liquids, carbon dioxide, cross-linked PEGDA,↗

Strategy for Extending the Stability of Bio‐oil‐Derived Phenolic Oligomers by Mild Hydrotreatment with Ionic‐Liquid‐Stabilized Nanoparticles

Abstract The development of catalytic transformations and processes is essential to utilize bio‐oil and lignin derivatives. Metal nanoparticles (M‐NPs) stabilized in ionic liquids (ILs) are promising for the catalytic hydrotreatment of bio‐oil because the properties of the catalyst system can be customized by combining the appropriate IL and metal nanoparticles. Herein, we demonstrate an experimental approach to stabilize lignin‐derived phenolics isolated from bio‐oil with ruthenium NPs stabilized by an ionic copolymer in 1‐ethyl‐3‐methylimidazolium acetate ([C 2 C 1 Im][OAc]). The mild hydrotreatment of phenolic oligomers (POs) was performed with the synthesized M‐NP catalyst at 100 °C for 6 h. Hydrotreatment of the POs resulted in enhanced thermal stability of the POs by as much as a factor of three, as determined by the aging index and by reducing reactive functionalities, which was also confirmed by NMR spectroscopy and GC analysis. The results support our hypothesis that M‐NPs stabilized in ILs can effectively stabilize POs under mild conditions, which could be applicable to any lignin‐derived phenolic.

Kim, Kwang Ho↗

Enhancing CO 2 Transport Across a PEEK‐Ionene Membrane and Water‐Lean Solvent Interface

Abstract Efficient direct air capture (DAC) of CO 2 will require strategies to deal with the relatively low concentration in the atmosphere. One such strategy is to employ the combination of a CO 2 ‐selective membrane coupled with a CO 2 capture solvent acting as a draw solution. Here, the interactions between a leading water‐lean carbon‐capture solvent, a polyether ether ketone (PEEK)‐ionene membrane, CO 2 , and combinations were probed using advanced NMR techniques coupled with advanced simulations. We identify the speciation and dynamics of the solvent, membrane, and CO 2 , presenting spectroscopic evidence of CO 2 diffusion through benzylic regions within the PEEK‐ionene membrane, not spaces in the ionic lattice as expected. Our results demonstrate that water‐lean capture solvents provide a thermodynamic and kinetic funnel to draw CO 2 from the air through the membrane and into the bulk solvent, thus enhancing the performance of the membrane. The reaction between the carbon‐capture solvent and CO 2 produces carbamic acid, disrupting interactions between the imidazolium (Im + ) cations and the bistriflimide anions within the PEEK‐ionene membrane, thereby creating structural changes through which CO 2 can diffuse more readily. Consequently, this restructuring results in CO 2 diffusion at the interface that is faster than CO 2 diffusion in the bulk carbon‐capture solvent.

Walter, Eric D.↗

Validation of (not-historical) large-event near-fault ground-motion simulations for use in civil engineering applications

Ground-motion simulations generated from physics-based wave propagation models are gaining increasing interest in the engineering community for their potential to inform the performance-based design and assessment of infrastructure residing in active seismic areas. A key prerequisite before the ground-motion simulations can be used with confidence for application in engineering domains is their comprehensive and rigorous investigation and validation. This article provides a four-step methodology and acceptance criteria to assess the reliability of simulated ground motions of not historical events, which includes (1) the selection of a population of real records consistent with the simulated scenarios, (2) the comparison of the distribution of Intensity Measures (IMs) from the simulated records, real records, and Ground-Motion Prediction Equations (GMPEs), (3) the comparison of the distribution of simple proxies for building response, and (4) the comparison of the distribution of Engineering Demand Parameters (EDPs) for a realistic model of a structure. Specific focus is laid on near-field ground motions (<10km) from large earthquakes (M w 7), for which the database of real records for potential use in engineering applications is severely limited. The methodology is demonstrated through comparison of (2490) near-field synthetic records with 5 Hz resolution generated from the Pitarka et al (2019) kinematic rupture model with a population of (38) pulse-like near-field real records from multiple events and, when applicable, with NGA-W2 GMPEs. Lastly, the proposed procedure provides an effective method for informing and advancing the science needed to generate realistic ground-motion simulations, and for building confidence in their use in engineering domains.

42 ENGINEERING↗

Identification of Hip BMD Loss and Fracture Risk Markers Through Population-Based Serum Proteomics: HIP BMD LOSS & FRACTURE RISK MARKERS BY POPULATION-BASED SERUM PROTEOMICS

Accelerated bone loss significantly increases the risk of osteoporosis and fracture. The mechanisms underlying bone loss remain incompletely understood, and there are few available biomarkers. We utilized a novel proteomics approach to identify serum peptides and proteins associated with bone loss in 1967 older men who were randomly chosen from the Osteoporotic Fracture in Men Study (MrOS study) (age ≥ 65 yrs). Men had 2-3 measures of femoral neck BMD over an average follow-up of 4.6 years. Change in BMD was estimated and then categorized into three groups: maintained BMD (n=453), expected loss (n=1185) and accelerated loss (n=237). A liquid chromatography–ion mobility separation-mass spectrometry (LC-IMS-MS) proteomics platform was used to identify and quantify peptides from serum proteins. The whole cohort was randomly divided into discovery (N= 960) and validation (N= 915) sub-cohorts. Linear regression models and a random forest approach were used to discover differentially abundant individual peptides and a proteomic signature that distinguished individuals with accelerated bone loss from those who maintained BMD. Network analyses were performed using the MetaCore knowledgebase. We identified 12 peptides that were associated with BMD loss in both discovery (P< 0.1 FDR) and replication sub-cohorts (P<0.05). Those 12 peptides mapped to the following proteins: ALS, LYVE1, RNAS1, C2, ICOSL, C163A, C7, HEMO, CD14, CERU, CRAC1 and CD59. Meta-analysis of peptidesassociated with bone loss identified 6 additional proteins including GRP78, IGF-2, SHBG, ENPP2, IBP2 and IBP6. We also identified a proteomic signature that was predictive of BMD loss with a discriminative value similar to serum bone marker carboxy-terminal collagen crosslink peptide (CTX). Interestingly, combining the proteomic signature with CTX significantly improved the ability to discriminate men with accelerated loss. In summary, we have identified potential new biomarkers for bone loss that provide a more in depth understanding of its pathophysiology.

59 BASIC BIOLOGICAL SCIENCES↗

Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sulfur isotope analysis of microcrystalline iron sulfides using secondary ion mass spectrometry imaging: Extracting local paleo-environmental information from modern and ancient sediments

Rationale: Sulfur isotope ratio measurements of bulk sulfide from marine sediments have often been used to reconstruct environmental conditions associated with their formation. In situ microscale spot analyses by secondary ion mass spectrometry (SIMS) and laser ablation multiple-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) have been utilized for the same purpose. However, these techniques are often not suitable for studying small (≤10 μm) grains or for detecting intra-grain variability. Methods: In this work, we present a method for the physical extraction (using lithium polytungstate heavy liquid) and subsequent sulfur isotope analysis (using SIMS; CAMECA IMS 7f-GEO) of microcrystalline iron sulfides. SIMS sulfur isotope ratio measurements were made via Cs + bombardment of raster squares with sides of 20–130 μm, using an electron multiplier (EM) detector to collect counts of 32 S - and 34 S - for each pixel (128 × 128 pixel grids) for between 20 and 960 cycles. Results: The extraction procedure did not discernibly alter pyrite grain-size distributions. The apparent inter-grain variability in 34 S/ 32 S in 1–4 μm-sized pyrite and marcasite fragments from isotopically homogeneous hydrothermal crystals was ~ ±2‰ (1σ), comparable with the standard error of the mean for individual measurements (≤ ±2‰, 1σ). In contrast, grain-specific 34 S/ 32 S ratios in modern and ancient sedimentary pyrites and marcasites can have inter- and intra-grain variability >60‰. The distributions of intra-sample isotopic variability are consistent with bulk 34 S/ 32 S values. Conclusions: SIMS analyses of isolated iron sulfide grains yielded distributions that are isotopically representative of bulk 34 S/ 32 S values. Populations of iron sulfide grains from sedimentary samples record the evolution of the S-isotopic composition of pore water sulfide in their S-isotopic compositions. These data allow past local environmental conditions to be inferred.

59 BASIC BIOLOGICAL SCIENCES↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of δ 13 C analyses of individual foraminifer ( Orbulina universa ) shells by secondary ion mass spectrometry and gas source mass spectrometry

Rationale: The use of secondary ion mass spectrometry (SIMS) to perform micrometer-scale in situ carbon isotope (δ 13 C) analyses of shells of marine microfossils called planktic foraminifers holds promise to explore calcification and ecological processes. The potential of this technique, however, cannot be realized without comparison to traditional whole-shell δ 13 C values measured by gas source mass spectrometry (GSMS). Methods: Paired SIMS and GSMS δ 13 C values measured from final chamber fragments of the same shell of the planktic foraminifer Orbulina universa are compared. The SIMS–GSMS δ 13 C differences (Δ 13 C SIMS-GSMS ) were determined via paired analysis of hydrogen peroxide-cleaned fragments of modern cultured specimens and of fossil specimens from deep-sea sediments that were either untreated, sonicated, and cleaned with hydrogen peroxide or vacuum roasted. After treatment, fragments were analyzed by a CAMECA IMS 1280 SIMS instrument and either a ThermoScientific MAT-253 or a Fisons Optima isotope ratio mass spectrometer (GSMS). Results: Paired analyses of cleaned fragments of cultured specimens (n = 7) yield no SIMS–GSMS δ 13 C difference. However, paired analyses of untreated (n = 18) and cleaned (n = 12) fragments of fossil shells yield average Δ 13 C SIMS-GSMS values of 0.8‰ and 0.6‰ (±0.2‰, 2 SE), respectively, while vacuum roasting of fossil shell fragments (n = 11) removes the SIMS–GSMS δ 13 C difference. Conclusions: The noted Δ 13 C SIMS-GSMS values are most likely due to matrix effects causing sample–standard mismatch for SIMS analyses but may also be a combination of other factors such as SIMS measurement of chemically bound water. The volume of material analyzed via SIMS is ~10 5 times smaller than that analyzed by GSMS; hence, the extent to which these Δ 13 C SIMS-GSMS values represent differences in analyte or instrument factors remains unclear.

58 GEOSCIENCES↗

Ion Mobility Separations of Isomers based upon Long Path Length Structures for Lossless Ion Manipulations Combined with Mass Spectrometry

Mass spectrometry (MS)-based multi-omic measurements, including proteomics, metabolomics, lipidomics, and glycomics, are increasingly transforming our ability to characterize and understand biological systems, but, presently have limitations due to the chemical diversity and range of abundances of biomolecules in complex samples. Advances addressing these challenges increasingly are based upon the ability to quickly separate, react and otherwise manipulate sample components for analysis by MS. Here we report on a new approach using Structures for Lossless Ion Manipulations (SLIM) to enable long serpentine path ion mobility spectrometry (IMS) separations followed by MS analyses. This approach provides previously unachieved mobility biomolecule isomer separations for biomolecular species, in conjunction with more effective ion utilization, and producing a basis for the improved characterization of very small samples.

Environmental Molecular Sciences Laboratory↗

Search for anomalous couplings in the W tb vertex from the measurement of double differential angular decay rates of single top quarks produced in the t-channel with the ATLAS detector

The electroweak production and subsequent decay of single top quarks is determined by the properties of the Wtb vertex. This vertex can be described by the complex parameters of an effective Lagrangian. An analysis of angular distributions of the decay products of single top quarks produced in the t -channel constrains these parameters simultaneously. The analysis described in this paper uses 4.6 fb -1 of proton-proton collision data at √s=7 TeV collected with the ATLAS detector at the LHC. Two parameters are measured simultaneously in this analysis. The fraction f 1 of decays containing transversely polarised W bosons is measured to be 0.37 ± 0.07 (stat.⊕syst.). The phase δ - between amplitudes for transversely and longitudinally polarised W bosons recoiling against left-handed b-quarks is measured to be -0.014π ± 0.036π (stat.⊕syst.). The correlation in the measurement of these parameters is 0.15. These values result in two-dimensional limits at the 95% confidence level on the ratio of the complex coupling parameters g R and V L , yielding Re[g R /V L ] ϵ [-0.36, 0.10] and Im[g R /V L ] ϵ [-0.17, 0.23] with a correlation of 0.11. We find the results are in good agreement with the predictions of the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the strong-coupling region of SU( N ) Seiberg-Witten theory

We consider the Seiberg-Witten solution of pure N = 2 gauge theory in four dimensions, with gauge group SU(N). A simple exact series expansion for the dependence of the 2(N – 1) Seiberg-Witten periods a I (u), a DI (u) on the N – 1 Coulomb-branch moduli un is obtained around the Z 2N -symmetric point of the Coulomb branch, where all u n vanish. This generalizes earlier results for N = 2 in terms of hypergeometric functions, and for N = 3 in terms of Appell functions. Using these and other analytical results, combined with numerical computations, we explore the global structure of the Kähler potential K = 1/2Σ I Im(a¯ I a DI ), which is single valued on the Coulomb branch. Evidence is presented that K is a convex function, with a unique minimum at the Z 2N -symmetric point. Finally, we explore candidate walls of marginal stability in the vicinity of this point, and their relation to the surface of vanishing Kähler potential.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of the Wtb vertex from the measurement of triple-differential angular decay rates of single top quarks produced in the t -channel at $ \sqrt{s}=8 $ TeV with the ATLAS detector

The electroweak production and subsequent decay of single top quarks in the t-channel is determined by the properties of the Wtb vertex, which can be described by the complex parameters of an effective Lagrangian. We use an analysis of a triple-differential decay rate in t-channel production to simultaneously determine five generalised helicity fractions and phases, as well as the polarisation of the produced top quark. The complex parameters are then constrained. This analysis is based on 20.2 fb -1 of proton-proton collision data at a centre-of-mass energy of 8 TeV collected with the ATLAS detector at the LHC. The fraction of decays containing transversely polarised W bosons is measured to be f 1 = 0.30 ± 0.05. The phase between amplitudes for transversely and longitudinally polarised W bosons recoiling against left-handed b-quarks is measured to be δ - = 0.002π + 0.017π + 0.016π , giving no indication of CP violation. The fractions of longitudinal or transverse W bosons accompanied by right-handed b-quarks are also constrained. Based on these measurements, limits are placed at 95% CL on the ratio of the complex coupling parameters Re [g R /V L ϵ [-0.12, 0.17] and Im [g R /V L ϵ [-0.07, 0.06]. Constraints are also placed on the ratios |V R /V L | and |g L /V L |. Additionally, the polarisation of single top quarks in the t-channel is constrained to be P > 0.72 (95% CL). None of the above measurements make assumptions about the value of any of the other parameters or couplings and all of them are in agreement with the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scientific aspects of hydraulic engineering in the Extreme North

Information relative to participation of the B. E. Vedeneev All-Russian Scientific-Research Institute of Hydraulic Engineering (VNIIG im. B. E. Vedeneeva) in the solution of problems of scientific verification of the design, construction, and operation of water-development works in regions of the Extreme North are presented. Basic characteristics of changes in the technical condition of high rock-and-earthfill dams, and the conditions under which their safety is ensured for long-term service in these regions are examined.

42 ENGINEERING↗

Optical Properties and Electronic Characteristics of Cerium in the Condensed State

The results of investigating optical properties of metallic cerium in the liquid and solid fi lm state are presented. Optical constants were measured by the ellipsometric Beattie method in the range of 0.42–2.6 μm at ambient temperature. Based on the measured refractive indices and the absorption coefficients, spectra of light conductivity σ, reflectivity R, and characteristic loss function Im ε{sup –1} were calculated. Based on experimental measurements in the IR region, electronic characteristics of liquid cerium and its polycrystalline film and their correlation with electrical conductivity have been determined.

36 MATERIALS SCIENCE↗

SDAT implementation for the analysis of radioxenon β–γ coincidence spectra

The Standard Deconvolution Analysis Tool (SDAT) was developed for analysis of radioxenon β-γ coincidence spectra measured as part of the International Monitoring System (IMS) as defined in the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The SDAT software analyzes each β-γ coincidence spectrum by fitting library vectors of each radionuclide of interest: 131mXe, 133mXe, 133Xe, and 135Xe. Detector background and radon are incorporated as optional components of the sample solution. Results are reported in mBq m-3. A new graphical user interface has been developed to facilitate ease of use and improve the data visualization. Automated energy vs. channel calibration algorithms were developed and implemented based on 137Cs β-γ coincidence spectra. Details on the user tool and testing are included.

Biegalski, S.↗

Engineering Upgrades to the Radionuclide Aerosol Sampler/Analyzer for the CTBT International Monitoring System

The Radionuclide Aerosol Sampler/Analyzer (RASA) is an automated aerosol collection and analysis system designed by Pacific Northwest National Laboratory in the 1990’s and is deployed in several locations around the world as part of the International Monitoring System (IMS) required under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The utility of such an automated system is the reduction of human intervention and the production of perfectly uniform results. However, maintainability and down time issues threaten this utility, even for systems with over 90% data availability. Engineering upgrades to the RASA are currently being pursued to address these issues, as well as Fukushima lessons learned. Current work includes a new automation control unit, and other potential improvements such as alternative detector cooling and sampling options are under review. This paper presents the current state of upgrades and improvements under investigation

Forrester, Joel B.↗