Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Linac-based extracranial radiosurgery with Elekta volumetric modulated arc therapy and an anatomy-based treatment planning system: Feasibility and initial experience

We reported our initial experience in using Elekta volumetric modulated arc therapy (VMAT) and an anatomy-based treatment planning system (TPS) for single high-dose radiosurgery (SRS-VMAT) of liver metastases. This study included a cohort of 12 patients treated with a 26-Gy single fraction. Single-arc VMAT plans were generated with Ergo++ TPS. The prescription isodose surface (IDS) was selected to fulfill the 2 following criteria: 95% of planning target volume (PTV) reached 100% of the prescription dose and 99% of PTV reached a minimum of 90% of prescription dose. A 1-mm multileaf collimator (MLC) block margin was added around the PTV. For a comparison of dose distributions with literature data, several conformity indexes (conformity index [CI], conformation number [CN], and gradient index [GI]) were calculated. Treatment efficiency and pretreatment dosimetric verification were assessed. Early clinical data were also reported. Our results reported that target and organ-at-risk objectives were met for all patients. Mean and maximum doses to PTVs were on average 112.9% and 121.5% of prescribed dose, respectively. A very high degree of dose conformity was obtained, with CI, CN, and GI average values equal to 1.29, 0.80, and 3.63, respectively. The beam-on-time was on average 9.3 minutes, i.e., 0.36 min/Gy. The mean number of monitor units was 3162, i.e., 121.6 MU/Gy. Pretreatment verification (3%-3 mm) showed an optimal agreement with calculated values; mean γ value was 0.27 and 98.2% of measured points resulted with γ < 1. With a median follow-up of 16 months complete response was observed in 12/14 (86%) lesions; partial response was observed in 2/14 (14%) lesions. No radiation-induced liver disease (RILD) was observed in any patients as well no duodenal ulceration or esophagitis or gastric hemorrhage. In conclusion, this analysis demonstrated the feasibility and the appropriateness of high-dose single-fraction SRS-VMAT in liver metastases performed with Elekta VMAT and Ergo++ TPS. Preliminary clinical outcomes showed a high rate of local control and minimum incidence of acute toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

At the limit of polychromatic microdiffraction

With a high-energy 3rd generation source like the Advanced Photon Source (APS), it is possible to push the performance of polychromatic microdiffraction far beyond current levels and to approach the intrinsic limit of the technique based on sample damage and the diffraction limit of X-rays. We describe ongoing efforts to improve the spatial, temporal and momentum transfer resolution of polychromatic microdiffraction on beamline 34-ID-E at the APS. The goal of this effort is to provide high-resolution images of 3D crystal structures over sufficient volumes and with sufficient detail to clarify the underlying physics of inhomogeneous structure and evolution on mesoscopic length scales. The performance of a high-speed amorphous Si area detector system and the ongoing development of advanced focusing optics will be described and discussed in light of the ultimate limits set by the physics of X-rays and materials, and in light of opportunities to field specialized insertion devices and optics for polychromatic microdiffraction.

36 MATERIALS SCIENCE↗

EPICS controlled sample mounting robots at the GM/CA CAT.

GM/CA CAT at Sector 23 of the advanced photon source (APS) is an NIH funded facility for crystallographic structure determination of biological macromolecules by X-ray diffraction [R.F. Fischetti, et al., GM/CA canted undulator beamlines for protein crystallography, Acta Crystallogr. A 61 (2005) C139]. The facility consists of three beamlines; two based on canted undulators and one on a bending magnet. The scientific and technical goals of the CAT emphasize streamlined, efficient throughput for a variety of sample types, sizes and qualities, representing the cutting edge of structural biology research. For this purpose all three beamlines are equipped with the ALS-style robots [C.W.Cork, et al. Status of the BCSB automated sample mounting and alignment system for macromolecular crystallography at the Advanced Light Source, SRI-2003, San-Francisco, CA, USA, August 25-29, 2003] for an automated mounting of cryo-protected macromolecular crystals. This report summarizes software and technical solutions implemented with the first of the three operational robots at beamline 23-ID-B. The automounter's Dewar can hold up to 72 or 96 samples residing in six Rigaku ACTOR magazines or ALS-style pucks, respectively. Mounting of a crystal takes approximately 2 s, during which time the temperature of the crystal is maintained near that of liquid nitrogen.

43 PARTICLE ACCELERATORS↗

Opticsconcept for apair of undulatorbeamlines for MX

We describe a concept for X-ray optics to feed a pair of macromolecular crystallography (MX) beamlines, which view canted undulator radiation sources in the same storage ring straight section. It can be deployed at NSLS-II and at other low-emittance third-generation synchrotron radiation sources where canted undulators are permitted, and makes the most of these sources and beamline floor space, even when the horizontal angle between the two canted undulator emissions is as little as 1-2 mrad. The concept adopts the beam-separation principles employed at the 23-ID (GM/CA-CAT) beamlines at the Advanced Photon Source (APS), wherein tandem horizontally deflecting mirrors separate one undulator beam from the other, following monochromatization by a double-crystal monochromator. The scheme described here would, in contrast, deliver the two tunable monochromatic undulator beams to separate endstations that address rather different and somewhat complementary purposes, with further beam conditioning imposed as required. A downstream micro-focusing beamline would employ dual-stage focusing for work at the micron scale and, unique to this design, switch to single-stage focusing for larger beams. On the other hand, the upstream, more highly automated beamline would only employ single-stage focusing.

43 PARTICLE ACCELERATORS↗

First demonstration of the fast-to-slow corrector current shift in the NSLS-II storage ring

In order to realize the full benefits of the high brightness and ultra-small beam sizes of NSLS-II, it is essential that the photon beams are exceedingly stable. In the circumstances of implementing local bumps, changing ID gaps, and long term drifting, the fast orbit feedback (FOFB) requires shifting the fast corrector strengths to the slow correctors to prevent the fast corrector saturation and to make the beam orbit stable in the sub-micron level. As the result, a reliable and precise technique of fast-to-slow corrector strength shift has been developed and tested at NSLS-II. This technique is based on the fast corrector response to the slow corrector change when the FOFB is on. In this article, the shift technique is described and the result of proof-of-principle experiment carried out at NSLS-II is presented. The maximum fast corrector current was reduced from greater than 0.45 A to less than 0.04 A with the orbit perturbation within ±1 μm.

43 PARTICLE ACCELERATORS↗

First experimental demonstration of time-resolved X-ray measurements with next-generation fast-timing MCP-PMT

We report the first successful time-resolved X-ray measurements at the APS 10-ID-B beamline by coupling ultrafast scintillators with photodetectors. Multiple scintillator and sensor pairs (LYSO, plastic scintillator, dynode PMTs, MCP-PMT), as well as a standalone detector (diamond), were tested to demonstrate the time-resolved measurements using hard X-rays at energies of 20 keV and above. The experimental results show that a number of choices exist for time-resolved high-energy X-ray beam measurement. Notably, by gating the photocathode, the Argonne fabricated fast-timing microchannel plate photomultiplier and LYSO crystal pair achieved fast signal detection with a rise time of 6 ns and a decay time of 33 ns. Furthermore, these experiments pave the way towards ultrafast imaging technologies using hard X-rays for many applications.

36 MATERIALS SCIENCE↗

Ultrafast inorganic scintillator-based front imager for Gigahertz Hard X-ray imaging

State-of-the art X-ray imaging cameras using silicon sensors for X-ray detection have demonstrated a frame-rate of 10 MHz and excellent performance for X-ray energies below 20 keV. We proposed a pixelated ultrafast inorganic scintillator-based front imager for GHz hard X-ray imaging. Here, the proposed imager is featured with a total absorption for hard X-ray photons, and provides sub-ns scintillation pulse width crucial for X-ray bunches of a few ns spacing foreseen at the proposed MaRIE facility. We measured temporal response of a dozen ultrafast and fast inorganic scintillators at the 10-ID-B site of the Advanced Photon Source (APS) of ANL. Crystal's response to hybrid X-ray beam of 30 keV, consisting of singlet bunches of 50 ps width and septuplet bunches of 27 ps width with 2.83 ns bunch spacing, was measured. Ultrafast inorganic scintillators, such as BaF 2 :Y and ZnO:Ga, show clearly resolved X-ray bunches for septuplets, as well as no degradation of amplitude for continuous eight septuplets, providing a proof of principle for the ultrafast inorganic scintillator-based total absorption front imager for the proposed MaRIE project.

47 OTHER INSTRUMENTATION↗

Requirements and R&D for detectors at the future Electron–Ion Collider

The Electron–Ion Collider’s (EIC’s) ability to collide high-energy electron beams with high-energy ion beams will provide access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unique access to the spatial and spin structure of gluons and sea-quarks in the proton and light nuclei. The EIC will be an unprecedented collider with luminosities 2–3 orders of magnitude higher than previous e + p colliders over a very wide range of center-of-mass energies, from 20 to 140 GeV, while accommodating highly polarized electron and nucleon beams. Equally demanding are the requirements for the detector(s) that will be needed to carry out the physics program: hermetic coverage in tracking, calorimetry and particle ID within a wide pseudorapidity range, substantial angular and momentum acceptance in the hadron-going direction, as well as high quality hadronic calorimetry among others. Finally, this paper gives a brief overview of the detector requirements, current general-purpose detector concepts, and the ongoing EIC detector R&D efforts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ATLAS ITk Strip detector system for the Phase-II LHC upgrade

In the view of the luminosity increase foreseen by the High-Luminosity Large Hadron Collider program at CERN, the ATLAS experiment initiated an R&D program to replace its complete inner detector (ID) system. The new Inner Tracker (ITk) system, anticipated to be installed by 2028, will be a new all-silicon based tracker including Strip and Pixel detector technologies. The new detector is designed to meet the requirements of operating under a harsh environment namely, high radiation levels, increased pile-up and data rates while decrease the material budget and maintain or even improve the performance. The Strip project has advanced in several areas the last years while facing challenges moving from pre-production to production. Here, this manuscript gives an overview of the ITk Strip system and describes the advancements and challenges to date.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Fate of MAb targeted Cd125mTe/ZnS nanoparaticles in vivo

Nanoparticles (NP) have potential as carriers for drugs and radioisotopes. Quantitative measures of NP biodistribution in vivo are needed to determine the effectiveness of these carriers. We have used a model system of radiolabeled quantum dots to document the competition between efficient vascular targeting and interaction of the NP with the reticuloendothelial (RE) system. We have prepared (125m)Te-labeled CdTe NP that are capped with ZnS. Te-125m has a half-life and decay characteristics very similar to those for (125)I. The synthesized particles are stable in aqueous solution and are derivatized with mercaptoacetic acid and then conjugated with specific antibody. To evaluate specific targeting, we used the monoclonal antibody MAb 201B that binds to murine thrombomodulin expressed in the lumen of lung blood vessels. The MAb-targeted NP were tested for targeting performance in vivo using single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging, tissue autoradiography and standard organ biodistribution techniques. Biodistribution was also determined in mice that had been depleted of phagocytic cells by use of clodronate-loaded liposomes. Cd(125m)Te/ZnS NP coupled with MAb 201B retained radioisotope and antibody activity and accumulated in lung (>400% injected dose [ID]/g) within 1 h of intravenous injection. Control antibody-coupled NP did not accumulate in lung (<10% ID/g) but accumulated in liver and spleen. Images from microSPECT/CT and autoradiography studies of the targeted NP document this specific uptake and demonstrate uniform distribution in lung with minor accumulation in liver and spleen. Within a few hours, a large fraction of lung-targeted NP redistributed to spleen and liver or was excreted. We hypothesized that NP attract phagocytic cells that engulfed and removed them from circulation. This was confirmed by comparing biodistribution of targeted NP in normal mice versus those depleted of phagocytic cells. In mice treated with clodronate liposomes, accumulation of NP in liver was reduced by fivefold, while accumulation in lung at 1 h was enhanced by approximately 50%. By 24 h, loss of the targeted NP from lung was inhibited by several-fold, while accumulation in liver and spleen remained constant. Thus, the treated mice had a much larger accumulation and retention of the NP at the target site and a decrease in dose to other organs except spleen. Nanoparticles composed of CdTe, labeled with (125m)Te and capped with ZnS, can be targeted with MAb to sites in the lumen of lung vasculature. In clodronate-treated mice, which have a temporary depletion of phagocytic cells, accumulation in liver was reduced dramatically, whereas that in spleen was not. The targeting to lung was several-fold more efficient in clodronate-treated mice due to larger initial accumulation and better retention of the MAb-targeted NP at that site. This model system indicates that targeting of NP preparations is a competition between the effectiveness of the targeting agent and the natural tendency for RE uptake of the particles. Temporary inhibition of the RE system may enhance the usefulness of NP for drug and radioisotope delivery.

59 BASIC BIOLOGICAL SCIENCES↗

The large-volume high-pressure facility at GSECARS: A 'Swiss-army-knife' approach to synchrotron-based experimental studies

A number of new techniques have been developed at the large-volume press (LVP) high-pressure facility at the GeoSoilEnviroCARS (GSECARS) sector of the advanced photon source (APS). This article describes the 10 MN (1000 T) and 2.5 MN (250 T) hydraulic presses in the insertion device (ID) and bending magnet (BM) beamlines, respectively, with several apparatus and various diffraction and imaging techniques developed since the inception of the facility. Several Kawai-type high-pressure modules, whose second-stage anvils range from 10 mm to 25.4 mm in edge lengths, are used in the hydraulic presses, with pressure (P) and temperature (T) capabilities up to 30 GPa and 3000 K. A DIA-type apparatus can be compressed in both presses for studies requiring large sample volumes. A deformation DIA (D-DIA) has been developed to allow controlled deformation studies on both crystalline and glass materials, using monochromatic diffraction and imaging, up to 20 GPa and 1800 K. A high-pressure tomography apparatus is available for conducting tomography studies at high P and T, with a typical spatial resolution of a few micrometers. Toroidal anvil modules provide large 2{theta} angles for studies of non-crystalline materials, and a new large D-DIA module is under construction for double-stage megabar pressure generation as well as deformation on large samples with the capability of acoustic emission detection. The flexible design of the monochromator at the BM beamline makes it feasible to switch between monochromatic and white-beam mode during an experiment, ideal for monochromatic imaging studies (e.g., high-P tomography) with energy-dispersive diffraction for pressure measurements. A new angle-dispersive diffraction technique has been developed for high P-T crystallography studies, where a solid-state detector is step-scanned, thereby collecting a large number of angle-dispersive spectra over a wide range of photon energies recorded in the multi-channel analyzer. An ultrasonic interferometer is available and has been used in several high-pressure modules for acoustic velocity measurements. These unique features allow world-wide users to select the best experimental techniques for tackling a wide range of problems relevant to earth and planetary science, materials science, physics, and chemistry. Scientific highlights are provided and future improvements and prospects are discussed.

43 PARTICLE ACCELERATORS↗

Hydrodynamics and Load Shedding Behavior of a Variable-Geometry Oscillating Surge Wave Energy Converter (OSWEC)

In order to improve their long-term viability, wave energy converters (WECs) need to be able to shed loads when a threshold wave condition is exceeded. As shown by Tom et al. (2016) [1], provision of adjustable flaps within the body of an oscillating surge wave energy converter (OSWEC) allows wave energy to pass through the device. A control system may then be able to open and close the flaps when waves approaching the device exceed preset thresholds. The variable-geometry OSWEC (VG-OSWEC) concept studied in this paper is a bottom-hinged, rectangular wave paddle with five flaps of elliptical cross-section embedded into the face of the paddle. System ID tests were conducted on this VG-OSWEC device at a 1:14 scale in a wave basin. Free decay tests showed that the damping was distinctly nonlinear when the flaps were fully open, and the natural frequency increased by 40% when compared with the flaps in a fully closed configuration. Tests with regular wave conditions were used to develop the response amplitude operator for the rotational motion about the hinge. These response amplitude operator results when compared with numerical simulations run using WEC-Sim/WAMIT and ANSYS AQWA, show strong agreement with the flap open and closed conditions. The regular-wave condition measurements also show that the wave excitation moment about the hinge was reduced by up to 60% when the flaps were fully open. The experiments serve to demonstrate the potential of the variable geometry design to shed loads and survive harsh ocean environments.

load shedding↗

Comparing three novel endpoints for developmental osteotoxicity in the embryonic stem cell test

Birth defects belong to the most serious side effects of pharmaceutical compounds or environmental chemicals. In vivo, teratogens most often affect the normal development of bones, causing growth retardation, limb defects or craniofacial malformations. The embryonic stem cell test (EST) is one of the most promising models that allow the in vitro prediction of embryotoxicity, with one of its endpoints being bone tissue development. The present study was designed to describe three novel inexpensive endpoints to assess developmental osteotoxicity using the model compounds penicillin G (non-teratogenic), 5-fluorouracil (strong teratogen) and all-trans retinoic acid (bone teratogen). These three endpoints were: quantification of matrix incorporated calcium by (1) morphometric analysis and (2) measurement of calcium levels as well as (3) activity of alkaline phosphatase, an enzyme involved in matrix calcification. To evaluate our data, we have compared the concentration curves and resulting ID{sub 50}s of the new endpoints with mRNA expression for osteocalcin. Osteocalcin is an exclusive marker found only in mineralized tissues, is regulated upon compound treatment and reliably predicts the potential of a chemical entity acting as a bone teratogen. By comparing the new endpoints to quantitative expression of osteocalcin, which we previously identified as suitable to detect developmental osteotoxicity, we were ultimately able to illustrate IMAGE analysis and Ca{sup 2+} deposition assays as two reliable novel endpoints for the EST. This is of particular importance for routine industrial assessment of novel compounds as these two new endpoints may substitute previously used molecular read-out methods, which are often costly and time-consuming.

60 APPLIED LIFE SCIENCES↗

Neurotoxicity of developmental hypothyroxinemia and hypothyroidism in rats: Impairments of long-term potentiation are mediated by phosphatidylinositol 3-kinase signaling pathway

Neurotoxicity of iodine deficiency-induced hypothyroidism during developmental period results in serious impairments of brain function, such as learning and memory. These impairments are largely irreversible, and the underlying mechanisms remain unclear. In addition to hypothyroidism, iodine deficiency may cause hypothyroxinemia, a relatively subtle form of thyroid hormone deficiency. Neurotoxicity of developmental hypothyroxinemia also potentially impairs learning and memory. However, more direct evidence of the associations between developmental hypothyroxinemia and impairments of learning and memory should be provided, and the underlying mechanisms remain to be elucidated. Thus, in the present study, we investigated the effects of developmental hypothyroxinemia and hypothyroidism on long-term potentiation (LTP), a widely accepted cellular model of learning and memory, in the hippocampal CA1 region. The activation of the phosphatidylinositol 3-kinase (PI3K) signaling pathway – a pathway closely associated with synaptic plasticity and learning and memory – was also investigated. Wistar rats were treated with iodine deficient diet or methimazole (MMZ) to induce developmental hypothyroxinemia or hypothyroidism. The results showed that developmental hypothyroxinemia caused by mild iodine deficiency and developmental hypothyroidism caused by severe iodine deficiency or MMZ significantly reduced the field-excitatory postsynaptic potential (f-EPSP) slope and the population spike (PS) amplitude. Decreased activation of the PI3K signaling pathway was also observed in rats subjected to developmental hypothyroxinemia or hypothyroidism. Our results may support the hypothesis that neurotoxicity of both developmental hypothyroxinemia and hypothyroidism causes damages to learning and memory. Our results also suggest that decreased activation of the PI3K signaling pathway may contribute to impairments of LTP caused by neurotoxicity of both developmental hypothyroxinemia and hypothyroidism. - Highlights: • Neurotoxicity of developmental hypothyroxinemia impaired LTP. • Decreased activation of PI3K signaling contributed to LTP impairments. • The recovery of TH after the developmental period did not prevent LTP impairments. • ID diet successfully induced neurotoxicity of developmental hypothyroxinemia.

60 APPLIED LIFE SCIENCES↗

Embryotoxic and pharmacologic potency ranking of six azoles in the rat whole embryo culture by morphological and transcriptomic analysis

Differential gene expression analysis in the rat whole embryo culture (WEC) assay provides mechanistic insight into the embryotoxicity of test compounds. In our study, we hypothesized that comparative analysis of the transcriptomes of rat embryos exposed to six azoles (flusilazole, triadimefon, ketoconazole, miconazole, difenoconazole and prothioconazole) could lead to a better mechanism-based understanding of their embryotoxicity and pharmacological action. For evaluating embryotoxicity, we applied the total morphological scoring system (TMS) in embryos exposed for 48 h. The compounds tested showed embryotoxicity in a dose-response fashion. Functional analysis of differential gene expression after 4 h exposure at the ID{sub 10} (effective dose for 10% decreased TMS), revealed the sterol biosynthesis pathway and embryonic development genes, dominated by genes in the retinoic acid (RA) pathway, albeit in a differential way. Flusilazole, ketoconazole and triadimefon were the most potent compounds affecting the RA pathway, while in terms of regulation of sterol function, difenoconazole and ketoconazole showed the most pronounced effects. Dose-dependent analysis of the effects of flusilazole revealed that the RA pathway related genes were already differentially expressed at low dose levels while the sterol pathway showed strong regulation at higher embryotoxic doses, suggesting that this pathway is less predictive for the observed embryotoxicity. A similar analysis at the 24-hour time point indicated an additional time-dependent difference in the aforementioned pathways regulated by flusilazole. In summary, the rat WEC assay in combination with transcriptomics could add a mechanistic insight into the embryotoxic potency ranking and pharmacological mode of action of the tested compounds. - Highlights: • Embryonic exposure to azoles revealed concentration-dependent malformations. • Transcriptomics could enhance the mechanistic knowledge of embryotoxicants. • Retinoic acid gene set identifies early embryotoxic responses to azoles. • Toxic versus pharmacologic potency determines functional efficacy.

60 APPLIED LIFE SCIENCES↗

The Chlamydomonas genome project: a decade on

The green alga Chlamydomonas reinhardtii is a popular unicellular organism for studying photosynthesis, cilia biogenesis, and micronutrient homeostasis. Ten years since its genome project was initiated an iterative process of improvements to the genome and gene predictions has propelled this organism to the forefront of the omics era. Housed at Phytozome, the plant genomics portal of the Joint Genome Institute (JGI), the most up-to-date genomic data include a genome arranged on chromosomes and high-quality gene models with alternative splice forms supported by an abundance of whole transcriptome sequencing (RNA-Seq) data. Here, we present here the past, present, and future of Chlamydomonas genomics. Specifically, we detail progress on genome assembly and gene model refinement, discuss resources for gene annotations, functional predictions, and locus ID mapping between versions and, importantly, outline a standardized framework for naming genes.

59 BASIC BIOLOGICAL SCIENCES↗

The coat protein of Alternanthera mosaic virus is the elicitor of a temperature-sensitive systemic necrosis in Nicotiana benthamiana, and interacts with a host boron transporter protein

Different isolates of Alternanthera mosaic virus (AltMV; Potexvirus), including four infectious clones derived from AltMV-SP, induce distinct systemic symptoms in Nicotiana benthamiana. Virus accumulation was enhanced at 15 °C compared to 25 °C; severe clone AltMV 3-7 induced systemic necrosis (SN) and plant death at 15 °C. No interaction with potexvirus resistance gene Rx was detected, although SN was ablated by silencing of SGT1, as for other cases of potexvirus-induced necrosis. Substitution of AltMV 3-7 coat protein (CP{sub SP}) with that from AltMV-Po (CP{sub Po}) eliminated SN at 15 °C, and ameliorated symptoms in Alternanthera dentata and soybean. Substitution of only two residues from CP{sub Po} [either MN(13,14)ID or LA(76,77)IS] efficiently ablated SN in N. benthamiana. CP{sub SP} but not CP{sub Po} interacted with Arabidopsis boron transporter protein AtBOR1 by yeast two-hybrid assay; N. benthamiana homolog NbBOR1 interacted more strongly with CP{sub SP} than CP{sub Po} in bimolecular fluorescence complementation, and may affect recognition of CP as an elicitor of SN. - Highlights: • Alternanthera mosaic virus CP is an elicitor of systemic necrosis in N. benthamiana. • Virus-induced systemic necrosis is enhanced at 15 °C compared to 25 °C. • Induction of systemic necrosis is dependent on as few as two CP amino acid residues. • These residues are at subunit interfaces within the same turn of the virion helix. • Inducer/non-inducer CPs interact differentially with a boron transporter protein.

60 APPLIED LIFE SCIENCES↗

Far-Field High-Energy Diffraction Microscopy: A Non-Destructive Tool for Characterizing the Microstructure and Micromechanical State of Polycrystalline Materials

A suite of non-destructive, three-dimensional X-ray microscopy techniques have recently been developed and used to characterize the microstructures of polycrystalline materials. These techniques utilize high-energy synchrotron radiation and include near-field and far-field diffraction microscopy (NF- and FF-HEDM, respectively) and absorption tomography. Several compatible sample environments have also been developed, enabling a wide range of 3D studies of material evolution. In this article, the FF-HEDM technique is described in detail, including its implementation at the 1-ID beamline of the Advanced Photon Source. Examples of how the information obtained from FF-HEDM can be used to deepen our understanding of structure-property-processing relationships in selected materials are presented.

36 MATERIALS SCIENCE↗