Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Heating effects on pyrogenic organic matter mass loss and temperature in a sand matrix in a lab setting from 2022

This dataset contains data associated with the preprint “A laboratory method for simulating the effects of subsequent fires on pyrogenic organic matter at different exposure depths in a sand matrix” (https://doi.org/10.1101/2024.07.30.605814), which has been accepted for publication in the International Journal of Wildland Fire. The dataset was generated to investigate the effects of subsequent fires on preexisting pyrogenic organic matter (PyOM) at different soil depths. Specifically, we designed a laboratory method to simulate soil heating from above, applying realistic heat flux profiles (High, Low, Control) derived from jack pine (Pinus banksiana Lamb.) log burns. Using a cone calorimeter, these profiles were applied to buried jack pine PyOM (produced at 350°C) in a sand matrix pyrocosm to examine PyOM mass loss at different depths (surface, 1 cm, 5 cm). Each treatment (e.g., High heat flux at 1 cm depth) was applied once to five replicates in a pyrocosm.The dataset includes mass loss fraction of PyOM and time-series temperature profiles (measured with type K thermocouples). Additionally, calibration datasets for high and low heat flux profiles are provided, including programmed heat flux profile data and three sets of calibration results. All datasets are in .csv format and were analyzed in R using code found at https://github.com/MengmengLuo/Reburning-pyrogenic-organic-matter-A-laboratory-method-for-dosing-dynamic-heat-fluxes-from-above. This dataset supports research on PyOM transformations during subsequent fires, and methodological advancements in simulating soil heating. It can be used to explore fire-induced PyOM alterations across different fire intensities and soil depths.

54 ENVIRONMENTAL SCIENCES↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83% by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/sq m). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 C, respectively. The boiling process during the entire heating period, as well as the jet-induced mixing process for the first 2 min of the mixing period, was also recorded on video. The unique features of the experimental results are the sustainability of high liquid superheats for long periods and the occurrence of explosive boiling at low heat fluxes (0.86 to 1.1 kW/sq m). For a heat flux of 0.97 kW/sq m, a wall superheat of 17.9 C was attained in 10 min of heating. This superheat was followed by an explosive boiling accompanied by a pressure spike of about 38% of the tank pressure at the inception of boiling. However, at this heat flux the vapor blanketing the heating surface could not be sustained. Steady nucleate boiling continued after the explosive boiling. The jet-induced fluid mixing results were obtained for jet Reynolds numbers of 1900 to 8000 and Weber numbers of 0.2 to 6.5. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number.

Hasan, Mohammad M.↗

A knowledge gap analysis for transient CHF prediction within RELAP5-3D

Here we compare several experimental pool and flow boiling critical heat flux experiments with corresponding computational models developed with RELAP5-3D. Encompassed within this paper are several sensitivity analyses for the boiling heat transfer correlations, critical heat flux (CHF) prediction within RELAP5-3D and the thermal properties of the cladding for experiments in the Transient Reactor Test Loop (TRTL) and Transient Reactor Test (TREAT) facilities. The sensitivity analyses were consistent in determining that there is a large contribution from the critical heat flux multiplier which in this application, accounts for the effects of power transient critical heat flux. Comparison to experimental results of both the TREAT CHF-SERTTA experimental campaign and a University of New Mexico (UNM) pool boiling experimental campaign demonstrate both the under-prediction of transient CHF and nucleate boiling heat transfer. To address the gaps in knowledge regarding the transient heating effect for both boiling heat transfer and CHF prediction, we present an experimental test matrix for the TRTL facility that will isolate the power transient effect under PWR relevant operational conditions. The test matrix will incorporate 6 power pulses with a constant energy deposition and a timescale that spans over several orders of magnitude, including a steady state test with an exponential period of 10 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimating the Soil Temperature Profile from a Single Depth Observation: A Simple Empirical Heatflow Solution

Two data sets of experimental field observations with a range of meteorological conditions are used to investigate the possibility of modeling near-surface soil temperature profiles in a bare soil. It is shown that commonly used heat flow methods that assume a constant ground heat flux can not be used to model the extreme variations in temperature that occur near the surface. This paper proposes a simple approach for modeling the surface soil temperature profiles from a single depth observation. This approach consists of two parts: 1) modeling an instantaneous ground flux profile based on net radiation and the ground heat flux at 5cm depth; 2) using this ground heat flux profile to extrapolate a single temperature observation to a continuous near surface temperature profile. The new model is validated with an independent data set from a different soil and under a range of meteorological conditions.

Holmes, Thomas↗

Heat transfer investigation in the junction region of circular cylinder normal to a flat plate at 90 deg location

External heat-transfer rates were measured on a flat plate in the junction region of a circular cylinder mounted normal to the plate at a location 90 deg from the stagnation point. This configuration simulates the junction of the shroud with gas-turbine vanes. Heat-transfer results are presented for laminar, transition, and turbulent boundary layers for a Mach number of 0.14 with gas temperatures of approximately 750 deg R over a flat plate at room temperature. The measurements were made in air for a unit Reynolds number, Re/cm, range of 11,000 to 58,000. Heat-transfer measurements were conducted in the 70-ft long, 4-in. diameter shock tube. A shock-wave reflection technique was used to produce a flow Mach number of 0.14. Thin-film platinum heat gages were mounted on the flat plate and along the line of the stagnation point of the cylinder to measure the local heat flux in the junction region. The experimental heat-transfer data were correlated with the laminar and turbulent boundary-layer theories for the flat plate. With the cylinder the heat fluxes on the flat plate were greatly increased in the junction region compared to the heat flux for the plate alone.

Nagamatsu, H. T.↗

Three-dimensional boundary element thermal shape sensitivity analysis

A computationally efficient and accurate shape design sensitivity analysis approach for the thermal response of 3D solid objects is presented which utilizes a direct, singular, boundary element analysis formulation. The theoretical formulation for the primary response (the surface temperature and normal heat flux) sensitivities and the secondary response (tangential components of the heat flux, vector, interior point temperature and heat flux vector components) sensitivities are presented. A number of computational issues related to the overall efficiency of implementation of these formulations are discussed. Numerical results are presented to demonstrate the accuracy and efficiency of this approach.

Prasad, K. G.↗

The effects of orbital and climatic variations on Martian surface heat flow

Large changes in the orbital elements of Mars on timescales of 10(exp 4) to 10(exp 6) years will cause widely varying climate, specifically surface temperatures, as a result of varying insolation. These surface temperature oscillations will produce subsurface thermal gradients which contribute to the total surface heat flux. We investigate the thermal behavior of the Martian regolith on orbital timescales and show that this climatological surface heat flux is spatially variable and contributes significantly to the total surface heat flux at many locations. We model the thermal behavior of the Martian regolith by calculating the mean annual surface temperatures for each epoch (spaced 1000 years apart to resolve orbital variations) for the past 200,000 years at a chosen location on the surface. These temperatures are used as a boundary condition for the deeper regolith and subsurface temperature oscillation are then computed. The surface climatological heat flux due to past climate changes can then be found from the temperature gradient between the surface and about 150 m depth (a fraction of the thermal skin depth on these timescales). This method provides a fairly accurate determination of the climatological heat flow component at a point; however, this method is computationally time consuming and cannot be applied to all points on the globe. To map the spatial variations in the surface heat flow we recognize that the subsurface temperature structure will be largely dominated by the most recent surface temperature oscillations. In fact, the climate component of the surface heat flow will be approximately proportional to the magnitude of the most recent surface temperature change. By calculating surface temperatures at all points globally for the present epoch and an appropriate past epoch, and combining these results with a series of more precise calculations described above, we estimate the global distribution of climatological surface heat flow.

Mellon, Michael T.↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Phase and time-resolved measurements of unsteady heat transfer and pressure in a full-stage rotating turbine

This paper presents detailed phase-resolved heat-flux data obtained on rotor blades and a comparison of simultaneously obtained time-resolved heat-flux and static pressure data obtained on the stationary shroud of a Garrett TFE 731-2 HP full-stage rotating turbine. A shock tube is used to generate a short-duration source of heated and pressurized air and platinum thin-film gages are used to obtain heat-flux measurements. Blade results are presented at several selected blade locations. Shroud surface pressure and heat-flux time histories are presented for comparable locations relative to the blade position.

Dunn, M. G.↗

Enlarged Nonclosure of Surface Energy Balance With Increasing Atmospheric Instabilities Linked to Changes in Coherent Structures

The nonclosure of surface energy balance remains an outstanding problem in eddy covariance (EC) measurements of land-surface fluxes of heat, water vapor, and CO 2 . Our data collected from an EC tower over a semiarid sagebrush ecosystem indicate that under unstable atmospheric conditions, the nonclosure becomes increased with increasing instability, consistent with many other studies. It is demonstrated that the increased nonclosure is not caused by the inadequate sampling of large-scale turbulent motions using a 30-min averaging interval, though the scales of turbulent motions dominating sensible and latent heat fluxes become enlarged with increasing instability. Quadrant analysis is then used to reveal that the flux contributions from ejections remain nearly constant with increasing instability, whereas the flux contributions from sweeps are reduced and their time fractions increase. Our results imply that the increased nonclosure of surface energy balance is associated with changes in turbulent structures including their dominant time scales and flux contributions of ejections and sweeps as the atmospheric instability increases, which require further studies using vertically distributed observations and/or large eddy simulations.

54 ENVIRONMENTAL SCIENCES↗

Visualization of R410A Flow Boiling Inside Horizontal Smooth Tubes under Diabatic Conditions

This article presents a novel approach to visualize the flow boiling in round tubes under “diabatic conditions”. In the visualization test section, a 3D printed round tube is placed inside a glass tube with secondary fluid at a higher temperature flowing in the annulus between the two tubes thus providing diabatic conditions. Experimental work was conducted for evaporating R410A flow in a horizontal smooth round tube with the inner diameter of 6.3 mm. Compared to the traditional adiabatic visualization technique, the more realistic evaporative condition is simulated and the developing evaporation process is captured. New insights for the flow behavior at low vapor quality are brought by this diabatic method. The vapor plug occurs at very low vapor quality, and this is attributed to the coalescence of bubbles generated on the heated tube wall. For the intermittent flow, liquid slug triggered by Kelvin–Helmholtz instability affects the nucleation on the tube wall. It brings the fresh liquid to rewet the dry surface and activate the nucleation sites. Finally, heat flux condition affects the heat transfer mechanisms during the flow boiling, and the heat transfer through the nucleate boiling mechanism increases as the heat flux increases.

3D printed↗

Global gyro-kinetic ion temperature gradient and trapped electron mode turbulence modelling in X -point geometry in negative and positive triangularity

Comparative modelling of ion temperature gradient (ITG)/trapped electron mode (TEM) turbulence in negative (NT) and positive (PT) triangularity plasma shapes was done using the nonlinear global full-f gyrokinetic particle code JOREK-GK in the realistic X-point tokamak geometry including the Scrape Off Layer (SOL) for TCV and DIII-D parameters. A comparison of JOREK-GK code with the gyrokinetic codes GS2 and GENE was done using NT/PT triangularity TCV L-modes parameters showing good agreement between codes in linear growth rates and clear beneficial effect of NT as compared to PT. Global non-linear modelling of the ITG/TEM saturated turbulence for realistic DIII-D NT pulses was done and compared with numerically constructed PT equilibrium with the same plasma profiles. Existence of longer correlation length of density fluctuations in PT compared to NT was demonstrated. Stronger and more sheared zonal flows are generated via Reynolds stress in NT compared to PT. These factors are stabilizing for TEM/ITG turbulence in NT and lead to smaller heat fluxes and heat conductivities in NT compared to PT configuration. Weak dependence of plasma confinement on collisionality and plasma rotation was found in modelling of DIII-D NT shots similar to the experiment. The confinement scaling with normalized ion gyro-radius ρ* was estimated both for NT and PT. Bohm-like scaling was obtained in both configurations, however with better confinement for NT compared to PT which could be favourable factor for reactor size machines.

ITG↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Continuous sensor suite measurements of weather, energy, soil and flux at four PumpHouse sites at the East River, Colorado

The purpose of this package is to monitor energy and water fluxes using a comprehensive set of sensors integrated on a tripod set up at 4 locations at the East River watershed in Colorado in the Upper Colorado River Basin as part of the Scientific Focus Area (SFA) research led by the Lawrence Berkeley National Lab (LBNL). This is a continuous sensor suite measurements of weather, energy, soil and flux at four East River pumphouse sites (ER-PHS1, ER-PHS2, ER-PHS3 and ER-PHS4) include: (1) soil CO2 concentration, CO2 flux and heat flux from soil surface; (2) photosynthetic active radiation flux at 1 m; (3) incoming/outcoming short and long wave radiation at 1 m, and user calculated net short and long wave radiation; (4) oxygen concentration and surface infrared temperature; (5) soil volumetric water content, temperature, and electrical conductivity at 10, 30, 60, 115 cm depth 115 cm depth; (6) soil matric potential and temperature at 30 cm depth; (7) incoming short wave radiation at 3 m height; (8) rainfall precipitation; (9) lightning strikes and strike distances; (10) wind direction and speed, maximum wind gust at 3 m; (11) air temperature, vapor pressure and barometric pressure at 3 m; (12) X _axis_level and Y_axis_level_(degree), tilt of the ATMOS 41 sensor; (13) maximum rainfall rate; (14) relative humidity sensor temperature at 3 m; (15) internally calculated vapor pressure deficit at 3 m with vapor pressure, relative humidity and sensor temperature measurements; (16) user calculated vapor pressure.These datasets contain data from Oct 11 2019 to March 20, 2020, and new datasets will be updated on annual basis. Files uploaded in Excel and Word, with copies in csv and pdf format.

54 ENVIRONMENTAL SCIENCES↗

A parameterization of sub-grid topographical effects on solar radiation in the E3SM Land Model (version 1.0): implementation and evaluation over the Tibetan Plateau

Abstract. Topography exerts significant influences on the incoming solar radiation at the land surface. A few stand-alone regional and global atmospheric models have included parameterizations for sub-grid topographic effects on solar radiation. However, nearly all Earth system models (ESMs) that participated in the Coupled Model Intercomparison Project (CMIP6) use a plane-parallel (PP) radiative transfer scheme that assumes that the terrain is flat. In this study, we incorporated a well-validated sub-grid topographic (TOP) parameterization in the Energy Exascale Earth System Model (E3SM) Land Model (ELM) version 1.0 to quantify the effects of sub-grid topography on solar radiation flux, including the shadow effects and multi-scattering between adjacent terrain. We studied the role of sub-grid topography by performing ELM simulations with the PP and TOP schemes over the Tibetan Plateau (TP). Additional ELM simulations were performed at multiple spatial resolutions to investigate the role of spatial scale on sub-grid topographic effects on solar radiation. The Moderate Resolution Imaging Spectroradiometer (MODIS) data was used to compare with the ELM simulations. The results show that topography has non-negligible effects on surface energy budget, snow cover, snow depth, and surface temperature over the TP. The absolute differences in surface energy fluxes for net solar radiation, latent heat flux, and sensible heat flux between TOP and PP exceed 20, 10, and 5 W m−2, respectively. The differences in land surface albedo, snow cover fraction, snow depth, and surface temperature between TOP and PP exceed 0.1, 0.1, 10 cm, and 1 K, respectively. The magnitude of the sub-grid topographic effects is dependent on seasons and elevations and is also sensitive to the spatial scales. Although the sub-grid topographic effects on solar radiation are larger with more spatial details at finer spatial scales, they cannot be simply neglected at coarse spatial scales. When compared to MODIS data, incorporating the sub-grid topographic effects overall reduces the biases of ELM in simulating surface energy balance, snow cover, and surface temperature, especially in the high-elevation and snow-covered regions over the TP. The inclusion of sub-grid topographic effects on solar radiation parameterization in ELM will contribute to advancing our understanding of the role of the surface topography on terrestrial processes over complex terrain.

Hao, Dalei (ORCID:0000000334979774)↗

A Parameterization of Sub-grid Topographical Effects on Solar Radiation in the E3SM Land Model (Version 1.0): Implementation and Evaluation Over the Tibetan Plateau

Topography exerts significant influences on the incoming solar radiation at the land surface. A few stand-alone regional and global atmospheric models have included parameterizations for sub-grid topographic effects on solar radiation. However, nearly all Earth System Models (ESMs) that participated in the Coupled Model Intercomparison Project (CMIP6) use a plane-parallel (PP) radiative transfer scheme that assumes the terrain is flat. In this study, we incorporated a well-validated sub-grid topographic (TOP) parameterization in the Energy Exascale Earth System Model (E3SM) Land Model (ELM) version 1.0 to quantify the effects of sub-grid topography on solar radiation flux, including the shadow effects and multi-scattering between adjacent terrain. The Moderate Resolution Imaging Spectroradiometer (MODIS) data was used to evaluate the performance of ELM. We studied the role of sub-grid topography by performing ELM simulations with the PP and TOP schemes over the Tibetan Plateau (TP). Additional ELM simulations were performed at multiple spatial resolutions to investigate the role of spatial scale on sub-grid topographic effects on solar radiation. When compared to MODIS data, incorporating the sub-grid topographic effects overall reduces the biases of ELM in simulating surface energy balance, snow cover and surface temperature especially in the high-elevation and snow-cover regions over the TP. Topography has non-negligible effects on surface energy budget, snow cover, and surface temperature over the TP. The absolute differences in surface energy fluxes for net solar radiation, latent heat flux, and sensible heat flux between TOP and PP exceed 20 W/m 2 , 10 W/m 2 , and 5 W/m 2 , respectively. The differences in land surface albedo, snow cover fraction, and surface temperature between TOP and PP exceed 0.1, 20%, and 1K, respectively. The magnitude of the sub-grid topographic effects is dependent on seasons and elevations, and is also sensitive to the spatial scales. Although the sub-grid topographic effects on solar radiation are more significant with more spatial details at finer spatial scales, they cannot be simply neglected at coarse spatial scales. The inclusion of sub-grid topographic effects on solar radiation parameterization in ELM will contribute to advancing our understanding of the role of the surface topography on terrestrial processes over complex terrain.

58 GEOSCIENCES↗

Remote estimation of surface moisture over a watershed

The author has identified the following significant results. Contoured analyses of moisture availability, moisture flux, sensible heat flux, thermal inertia, and day and nighttime temperatures over a Missouri watershed for a date in June and in September show that forests and creeks exhibit the highest values of moisture availability, whereas farmlands and villages are relatively dry. The distribution of moisture availability over agricultural districts differs significantly between the two cases. This difference is attributed to a change in the surface's vegetative canopy between June and September, with higher moisture availabilities found in the latter case. Horizontal variations of moisture, however, do indicate some relationship between moisture availability and both local rainfall accumulations and the nature of the terrain.

Kocin, P. J.↗