Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Assessing the Role of Volumetric Modulated Arc Therapy (VMAT) Relative to IMRT and Helical Tomotherapy in the Management of Localized, Locally Advanced, and Post-Operative Prostate Cancer

Purpose: To quantify differences in treatment delivery efficiency and dosimetry between step-and-shoot intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT) for prostate treatment. Methods and Materials: Twenty-five prostate cancer patients were selected retrospectively for this planning study. Treatment plans were generated for: prostate alone (n = 5), prostate + seminal vesicles (n = 5), prostate + seminal vesicles + pelvic lymph nodes (n = 5), prostate bed (n = 5), and prostate bed + pelvic lymph nodes (n = 5). Target coverage, dose homogeneity, integral dose, monitor units (MU), and sparing of organs at risk (OAR) were compared across techniques. Time required to deliver each plan was measured. Results: The dosimetric quality of IMRT, VMAT, and HT plans were comparable for target coverage (planning target volume V95%, clinical target volume V100% all >98.7%) and sparing of organs at risk (OAR) for all treatment groups. Although HT resulted in a slightly higher integral dose and mean doses to the OAR, it yielded a lower maximum dose to all OAR examined. VMAT resulted in reductions in treatment times over IMRT (mean = 75%) and HT (mean = 70%). VMAT required 15-38% fewer monitor units than IMRT over all treatment volumes, with the reduction per fraction ranging from 100-423 MU from the smallest to largest volumes. Conclusions: VMAT improves efficiency of delivery for equivalent dosimetric quality as IMRT and HT across various prostate cancer treatment volumes in the intact and postoperative settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Versus Single-Arc Intensity-Modulated Arc Therapy: A Collaborative Dosimetric Comparison Between Two Institutions

Purpose: Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. Methods and Materials: Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. Results: For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. Conclusions: Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Calculated Skin Doses in Postmastectomy Helical Tomotherapy

Purpose: To verify the accuracy of calculated skin doses in helical tomotherapy for postmastectomy radiation therapy (PMRT). Methods and Materials: In vivo thermoluminescent dosimeters (TLDs) were used to measure the skin dose at multiple points in each of 14 patients throughout the course of treatment on a TomoTherapy Hi.Art II system, for a total of 420 TLD measurements. Five patients were evaluated near the location of the mastectomy scar, whereas 9 patients were evaluated throughout the treatment volume. The measured dose at each location was compared with calculations from the treatment planning system. Results: The mean difference and standard error of the mean difference between measurement and calculation for the scar measurements was -1.8% {+-} 0.2% (standard deviation [SD], 4.3%; range, -11.1% to 10.6%). The mean difference and standard error of the mean difference between measurement and calculation for measurements throughout the treatment volume was -3.0% {+-} 0.4% (SD, 4.7%; range, -18.4% to 12.6%). The mean difference and standard error of the mean difference between measurement and calculation for all measurements was -2.1% {+-} 0.2% (standard deviation, 4.5%: range, -18.4% to 12.6%). The mean difference between measured and calculated TLD doses was statistically significant at two standard deviations of the mean, but was not clinically significant (i.e., was <5%). However, 23% of the measured TLD doses differed from the calculated TLD doses by more than 5%. Conclusions: The mean of the measured TLD doses agreed with TomoTherapy calculated TLD doses within our clinical criterion of 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Helical Tomotherapy in Stereotactic Body Radiation Therapy for Centrally Located Early Stage Non-Small-Cell Lung Cancer or Lung Metastases

Purpose: To investigate the ability of helical tomotherapy (HT) to spare critical organs immediately adjacent to the tumor target in stereotactic body radiation therapy (SBRT) for centrally located lung lesions. Methods and Materials: HT SBRT plans for 10 patients with centrally located lesions or lesions immediately adjacent to a critical structure were generated. A total of 70 Gy in 10 fractions was prescribed to the planning target volume (PTV) to satisfy a target volume coverage of {>=}95% PTV receiving 70 Gy and an established set of dose constraints for the organs at risk (OARs). Quality assurance (QA) of the HT plans was performed with both ion chamber and film measurements. Results: The PTV coverage criteria was met with 95% of the PTV receiving 70.68 {+-} 0.33 Gy for all cases even though the OARs immediately adjacent to the PTV ranged from 0.38 to 0.85 cm away. The mean lung dose (MLD), and V{sub 20} were 7.15 {+-} 1.44 Gy, and 11.93 {+-} 3.24 % for the total lung, respectively. The dose parameters of MLD, V{sub 5}, V{sub 10}, and V{sub 20} for the contralateral lung were significantly lower than those for the ipsilateral lung (p < 0.05). An average dose fall off from the PTV periphery to the edge of the immediately adjacent OAR was 47.6% over an average distance of 4.87 mm. Comparison of calculated and measured doses with the ion chamber showed an average of 1.85% point dose error, whereas an average mean gamma and the area with a gamma larger than 1 of 0.20 and 0.94% were observed, respectively. Conclusion: HT allows the sparing of critical structures immediately adjacent to the tumor target, thus making SBRT for these centrally located lesions feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Encouraging Early Clinical Outcomes With Helical Tomotherapy-Based Image-Guided Intensity-Modulated Radiation Therapy for Residual, Recurrent, and/or Progressive Benign/Low-Grade Intracranial Tumors: A Comprehensive Evaluation

Purpose: To report early clinical outcomes of helical tomotherapy (HT)-based image-guided intensity-modulated radiation therapy (IMRT) in brain tumors of varying shape, size, and location. Materials and Methods: Patients with residual, recurrent, and/or progressive low-grade intracranial and skull-base tumors were treated on a prospective protocol of HT-based IMRT and followed clinicoradiologically. Standardized metrics were used for plan evaluation and outcome analysis. Results: Twenty-seven patients with 30 lesions were treated to a median radiotherapy dose of 54 Gy in 30 fractions. All HT plans resulted in excellent target volume coverage with steep dose-gradients. The mean (standard deviation) dose homogeneity index and conformity index was 0.07 (0.05) and 0.71 (0.08) respectively. At first response assessment, 20 of 30 lesions were stable, whereas 9 showed partial regression. One patient with a recurrent clival chordoma though neurologically stable showed imaging-defined progression, whereas another patient with stable disease on serial imaging had sustained neurologic worsening. With a median follow-up of 19 months (interquartile range, 11-26 months), the 2-year clinicoradiological progression-free survival and overall survival was 93.3% and 100% respectively. Conclusions: Careful selection of radiotherapy technique is warranted for benign/low-grade brain tumors to achieve durable local control with minimum long-term morbidity. Large or complex-shaped tumors benefit most from IMRT. Our early clinical experience of HT-based IMRT for brain tumors has been encouraging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Voxel-Based Dose Reconstruction for Total Body Irradiation With Helical TomoTherapy

Purpose: We have developed a megavoltage CT (MVCT)-based dose reconstruction strategy for total body irradiation (TBI) with helical TomoTherapy (HT) using a deformable registration model to account for the patient's interfraction changes. The proposed technique serves as an efficient tool for delivered dose verification and, potentially, plan adaptation. Methods and Materials: Four patients with acute myelogenous leukemia treated with TBI using HT were selected for this study. The prescription was 12 Gy, 2 Gy/fraction, twice per day, given at least 6 h apart. The original plan achieved coverage of 80% of the clinical target volume (CTV) by the 12 Gy isodose surface. MVCTs were acquired prior to each treatment. Regions of interest were contoured on each MVCT. The dose for each fraction was calculated based on the MVCT using the HT planned adaptive station. B-spline deformable registration was conducted to establish voxel-to-voxel correspondence between the MVCT and the planning CT. The resultant deformation vector was employed to map the reconstructed dose from each fraction to the same point as the plan dose, and a voxel-to-voxel summed dose from all six fractions was obtained. The reconstructed dose distribution and its dosimetric parameters were compared with those of the original treatment plan. Results: While changes in CTV contours occurred in all patients, the reconstructed dose distribution showed that the dose-volume histogram for CTV coverage was close (<1.5%) to that of the original plan. For sensitive structures, the differences between the reconstructed and the planned doses were less than 3.0%. Conclusion: Voxel-based dose reconstruction strategy that takes into account interfraction anatomical changes using MVCTs is a powerful tool for treatment verification of the delivered doses. This proposed technique can also be applied to adaptive TBI therapy using HT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Do We Need Daily Image-Guided Radiotherapy by Megavoltage Computed Tomography in Head and Neck Helical Tomotherapy? The Actual Delivered Dose to the Spinal Cord

Purpose: To quantify the actual delivered dose to the cervical spinal cord with different image-guided radiotherapy (IGRT) approaches during head and neck (HN) cancer helical tomotherapy. Methods and Materials: Twenty HN patients (HNpts) treated with bilateral nodal irradiation were analyzed. Daily megavoltage computed tomography MVCT) scans were performed for setup purposes. The maximum dose on the planning CT scan (plan-Dmax) and the magnitude and localization of the actual delivered Dmax (a-Dmax) were analyzed for four scenarios: daily image-guided radiotherapy (dIGRT), twice weekly IGRT (2 Multiplication-Sign WkIGRT), once weekly IGRT (1 Multiplication-Sign WkIGRT), and no IGRT at all (non-IGRT). The spinal cord was recontoured on 236 MVCTs for each scenario (total, 944 fractions), and the delivered dose was recalculated for each fraction (fx) separately. Results: Fifty-one percent of the analyzed fx for dIGRT, 56% of the analyzed fx for the 2 Multiplication-Sign WkIGRT, 62% of the analyzed fx for the 1 Multiplication-Sign WkIGRT, and 63% of the analyzed fx for the non-IGRT scenarios received a higher a-Dmax than the plan-Dmax. The median increase of dose in these fx was 3.3% more for dIGRT, 5.8% more for 2 Multiplication-Sign WkIGRT, 10.0% more for 1 Multiplication-Sign WkIGRT, and 9.5% more for non-IGRT than the plan-Dmax. The median spinal cord volumes receiving a higher dose than the plan-Dmax were 0.02 cm{sup 3} for dIGRT, 0.11 cm{sup 3} for 2 Multiplication-Sign WkIGRT, 0.31 cm{sup 3} for 1 Multiplication-Sign WkIGRT, and 0.22 cm{sup 3} for non-IGRT. Differences between the dIGRT and all other scenarios were statistically significant (p < 0.05). Conclusions: Compared to the Dmax of the initial plan, daily IGRT had the smallest increase in dose. Furthermore, daily IGRT had the lowest proportion of fractions and the smallest volumes affected by a dose that was higher than the planned dose. For patients treated with doses close to the tolerance dose of the spinal cord, we recommend daily IGRT. For all other cases, twice weekly IGRT is sufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study

Purpose: We investigated whether treatment-planning system (TPS)-calculated dose accurately reflects skin dose received for patients receiving adjuvant breast radiotherapy (RT) with standard three-dimensional conformal RT (3D-CRT) or skin-sparing helical tomotherapy (HT). Methods and Materials: Fifty patients enrolled in a randomized controlled trial investigating acute skin toxicity from adjuvant breast RT with 3D-CRT compared to skin-sparing HT, where a 5-mm strip of ipsilateral breast skin was spared. Thermoluminescent dosimetry or optically stimulated luminescence measurements were made in multiple locations and were compared to TPS-calculated doses. Skin dosimetric parameters and acute skin toxicity were recorded in these patients. Results: With HT there was a significant correlation between calculated and measured dose in the medial and lateral ipsilateral breast (r = 0.67, P<.001; r = 0.44, P=.03, respectively) and the medial and central contralateral breast (r = 0.73, P<.001; r = 0.88, P<.001, respectively). With 3D-CRT there was a significant correlation in the medial and lateral ipsilateral breast (r = 0.45, P=.03; r = 0.68, P<.001, respectively); the medial and central contralateral breast (r = 0.62, P=.001; r = 0.86, P<.001, respectively); and the mid neck (r = 0.42, P=.04, respectively). On average, HT-calculated dose overestimated the measured dose by 14%; 3D-CRT underestimated the dose by 0.4%. There was a borderline association between highest measured skin dose and moist desquamation (P=.05). Skin-sparing HT had greater skin homogeneity (homogeneity index of 1.39 vs 1.65, respectively; P=.005) than 3D-CRT plans. HT plans had a lower skin{sub V50} (1.4% vs 5.9%, respectively; P=.001) but higher skin{sub V40} and skin{sub V30} (71.7% vs 64.0%, P=.02; and 99.0% vs 93.8%, P=.001, respectively) than 3D-CRT plans. Conclusion: The 3D-CRT TPS more accurately reflected skin dose than the HT TPS, which tended to overestimate dose received by 14% in patients receiving adjuvant breast RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy for Whole-Brain Irradiation With Integrated Boost to Multiple Brain Metastases: Evaluation of Dose Distribution Characteristics and Comparison With Alternative Techniques

Purpose: To quantitatively evaluate dose distribution characteristics achieved with helical tomotherapy (HT) for whole-brain irradiation (WBRT) with integrated boost (IB) to multiple brain metastases in comparison with alternative techniques. Methods and Materials: Dose distributions for 23 patients with 81 metastases treated with WBRT (30 Gy/10 fractions) and IB (50 Gy) were analyzed. The median number of metastases per patient (N{sub mets}) was 3 (range, 2-8). Mean values of the composite planning target volume of all metastases per patient (PTV{sub mets}) and of the individual metastasis planning target volume (PTV{sub ind} {sub met}) were 8.7 ± 8.9 cm{sup 3} (range, 1.3-35.5 cm{sup 3}) and 2.5 ± 4.5 cm{sup 3} (range, 0.19-24.7 cm{sup 3}), respectively. Dose distributions in PTV{sub mets} and PTV{sub ind} {sub met} were evaluated with respect to dose conformity (conformation number [CN], RTOG conformity index [PITV]), target coverage (TC), and homogeneity (homogeneity index [HI], ratio of maximum dose to prescription dose [MDPD]). The dependence of dose conformity on target size and N{sub mets} was investigated. The dose distribution characteristics were benchmarked against alternative irradiation techniques identified in a systematic literature review. Results: Mean ± standard deviation of dose distribution characteristics derived for PTV{sub mets} amounted to CN = 0.790 ± 0.101, PITV = 1.161 ± 0.154, TC = 0.95 ± 0.01, HI = 0.142 ± 0.022, and MDPD = 1.147 ± 0.029, respectively, demonstrating high dose conformity with acceptable homogeneity. Corresponding numbers for PTV{sub ind} {sub met} were CN = 0.708 ± 0.128, PITV = 1.174 ± 0.237, TC = 0.90 ± 0.10, HI = 0.140 ± 0.027, and MDPD = 1.129 ± 0.030, respectively. The target size had a statistically significant influence on dose conformity to PTV{sub mets} (CN = 0.737 for PTV{sub mets} ≤4.32 cm{sup 3} vs CN = 0.848 for PTV{sub mets} >4.32 cm{sup 3}, P=.006), in contrast to N{sub mets}. The achieved dose conformity to PTV{sub mets}, assessed by both CN and PITV, was in all investigated volume strata well within the best quartile of the values reported for alternative irradiation techniques. Conclusions: HT is a well-suited technique to deliver WBRT with IB to multiple brain metastases, yielding high-quality dose distributions. A multi-institutional prospective randomized phase 2 clinical trial to exploit efficacy and safety of the treatment concept is currently under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peripheral Dose Heterogeneity Due to the Thread Effect in Total Marrow Irradiation With Helical Tomotherapy

Purpose: To report potential dose heterogeneity leading to underdosing at different skeletal sites in total marrow irradiation (TMI) with helical tomotherapy due to the thread effect and provide possible solutions to reduce this effect. Methods and Materials: Nine cases were divided into 2 groups based on patient size, defined as maximum left-to-right arm distance (mLRD): small mLRD (≤47 cm) and large mLRD (>47 cm). TMI treatment planning was conducted by varying the pitch and modulation factor while a jaw size (5 cm) was kept fixed. Ripple amplitude, defined as the peak-to-trough dose relative to the average dose due to the thread effect, and the dose–volume histogram (DVH) parameters for 9 cases with various mLRD was analyzed in different skeletal regions at off-axis (eg, bones of the arm or femur), at the central axis (eg, vertebrae), and planning target volume (PTV), defined as the entire skeleton plus 1-cm margin. Results: Average ripple amplitude for a pitch of 0.430, known as one of the magic pitches that reduce thread effect, was 9.2% at 20 cm off-axis. No significant differences in DVH parameters of PTV, vertebrae, or femur were observed between small and large mLRD groups for a pitch of ≤0.287. Conversely, in the bones of the arm, average differences in the volume receiving 95% and 107% dose (V95 and V107, respectively) between large and small mLRD groups were 4.2% (P=.016) and 16% (P=.016), respectively. Strong correlations were found between mLRD and ripple amplitude (rs=.965), mLRD and V95 (rs=−.742), and mLRD and V107 (rs=.870) of bones of the arm. Conclusions: Thread effect significantly influences DVH parameters in the bones of the arm for large mLRD patients. By implementing a favorable pitch value and adjusting arm position, peripheral dose heterogeneity could be reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-institutional Feasibility Study of a Fast Patient Localization Method in Total Marrow Irradiation With Helical Tomotherapy: A Global Health Initiative by the International Consortium of Total Marrow Irradiation

Purpose: To develop, characterize, and implement a fast patient localization method for total marrow irradiation. Methods and Materials: Topographic images were acquired using megavoltage computed tomography (MVCT) detector data by delivering static orthogonal beams while the couch traversed through the gantry. Geometric and detector response corrections were performed to generate a megavoltage topogram (MVtopo). We also generated kilovoltage topograms (kVtopo) from the projection data of 3-dimensional CT images to reproduce the same geometry as helical tomotherapy. The MVtopo imaging dose and the optimal image acquisition parameters were investigated. A multi-institutional phantom study was performed to verify the image registration uncertainty. Forty-five MVtopo images were acquired and analyzed with in-house image registration software. Results: The smallest jaw size (front and backup jaws of 0) provided the best image contrast and longitudinal resolution. Couch velocity did not affect the image quality or geometric accuracy. The MVtopo dose was less than the MVCT dose. The image registration uncertainty from the multi-institutional study was within 2.8 mm. In patient localization, the differences in calculated couch shift between the registration with MVtopo-kVtopo and MVCT-kVCT images in lateral, cranial–caudal, and vertical directions were 2.2 ± 1.7 mm, 2.6 ± 1.4 mm, and 2.7 ± 1.1 mm, respectively. The imaging time in MVtopo acquisition at the couch speed of 3 cm/s was <1 minute, compared with ≥15 minutes in MVCT for all patients. Conclusion: Whole-body MVtopo imaging could be an effective alternative to time-consuming MVCT for total marrow irradiation patient localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast Megavoltage Computed Tomography: A Rapid Imaging Method for Total Body or Marrow Irradiation in Helical Tomotherapy

Purpose: Megavoltage computed tomographic (MVCT) imaging has been widely used for the 3-dimensional (3-D) setup of patients treated with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, the result of slow couch speeds of approximately 1 mm/s, which can be difficult for the patient to tolerate. We sought to develop an MVCT imaging method allowing faster couch speeds and to assess its accuracy for image guidance for HT. Methods and Materials: Three cadavers were scanned 4 times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm with a penalty term of total variation and with a conventional filtered back projection (FBP) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors from the 2 reconstruction algorithms were compared. This fast MVCT imaging was tested in 3 cases of total marrow irradiation as a clinical trial. Results: The 3-D registration errors of the MVCT images reconstructed with the IR algorithm were smaller than the errors of images reconstructed with the FBP algorithm at fast couch speeds (2, 3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, faster MVCT (3 mm/s couch speed) scanning reduced the imaging time and still generated images useful for anatomic registration. Conclusions: Fast MVCT with the IR algorithm is clinically feasible for large 3-D target localization, which may reduce the overall time for the treatment procedure. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area. Automated integration of this imaging is at least needed to further assess its clinical benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unique microporous NbO-type Co{sup II}/Zn{sup II} MOFs from double helical chains: Sorption and luminescent properties

Under solvothermal conditions, the reactions of Co{sup II}/Zn{sup II} ions with bent ligand 3-(pyridin-4-yl)-5-(pyrazin-2-yl)-1H-1,2,4-triazole (4-Hpzpt) afford two compounds {[M(4-pzpt)_2] guest}{sub n} (guest=H{sub 2}O, M=Co{sup II} (1), Zn{sup II} (2)). Both compounds are the thermally and hydrolytically robust 4-connected 3D NbO framework, which formed by double helical chains to give rise to 1D hollow nanochannel with uncoordinated nitrogens completely exposed on the pore surface. Compound 1 exhibits improved N{sub 2}, CO{sub 2} and H{sub 2} uptake capacities, while compound 2 displays the strong luminescent emission with obvious red shift. - Graphical abstract: Two 2-fold interpenetrated NbO-type MOFs with 1D nanochannel were synthesized. Compound 1 exhibits improved N{sub 2}, CO{sub 2} and H{sub 2} uptake capacities, while compound 2 displays the strong fluorescent emission with obvious red shift. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The inhibiting effect of dislocation helices on the stress-induced orientation of S' precipitates in Al–Cu–Mg alloy

The phenomenon of restrained stress-induced preferential orientation of S′ precipitates is investigated using a single-crystal of Al–1.23Cu–0.43 Mg alloy. Al–1.23Cu–0.43 Mg single-crystal specimens are subjected to stress aging, and the microstructure is analyzed by transmission electron microscopy (TEM). It is found that the stress-induced preferential orientation of S′ precipitates is restrained owing to the dislocations produced by a higher stress. The effect of dislocations on the oriented precipitates depends on the total length of the intersection lines for precipitate habit planes and dislocation glide planes. This investigation not only provides important insight into solving the anisotropy problem attributed to precipitation strengthening, but also offers a benchmark for choosing the appropriate stress range in manufacturing of Al–Cu–Mg alloys. - Highlights: • Single crystals of an Al–Cu–Mg alloy were prepared for the investigations. • A phenomenon of restrained stress-induced preferential orientation of S′ precipitates was found. • The influence of dislocation helices on precipitation during stress-aging was studied. • Difference of orientation degree of S′ precipitates and θ′ precipitates was explained. • A basis for choosing the appropriate stress range in manufacturing of Al–Cu–Mg alloys is provided.

36 MATERIALS SCIENCE↗

Helical Tomotherapy for Radiotherapy in Esophageal Cancer: A Preferred Plan With Better Conformal Target Coverage and More Homogeneous Dose Distribution

We compare different radiotherapy techniques-helical tomotherapy (tomotherapy), step-and-shoot IMRT (IMRT), and 3-dimensional conformal radiotherapy (3DCRT)-for patients with mid-distal esophageal carcinoma on the basis of dosimetric analysis. Six patients with locally advanced mid-distal esophageal carcinoma were treated with neoadjuvant chemoradiation followed by surgery. Radiotherapy included 50 Gy to gross planning target volume (PTV) and 45 Gy to elective PTV in 25 fractions. Tomotherapy, IMRT, and 3DCRT plans were generated. Dose-volume histograms (DVHs), homogeneity index (HI), volumes of lung receiving more than 10, 15, or 20 Gy (V{sub 10}, V{sub 15}, V{sub 20}), and volumes of heart receiving more than 30 or 45 Gy (V{sub 30}, V{sub 45}) were determined. Statistical analysis was performed by paired t-tests. By isodose distributions and DVHs, tomotherapy plans showed sharper dose gradients, more conformal coverage, and better HI for both gross and elective PTVs compared with IMRT or 3DCRT plans. Mean V{sub 20} of lung was significantly reduced in tomotherapy plans. However, tomotherapy and IMRT plans resulted in larger V{sub 10} of lung compared to 3DCRT plans. The heart was significantly spared in tomotherapy and IMRT plans compared to 3DCRT plans in terms of V{sub 30} and V{sub 45}. We conclude that tomotherapy plans are superior in terms of target conformity, dose homogeneity, and V{sub 20} of lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Application of Helical Tomotherapy in Whole Skull Palliative Radiotherapy

Helical tomotherapy (HT) is a radiation planning/delivery platform that combines inversely planned IMRT with on-board megavoltage imaging. A unique HT radiotherapy whole skull brain sparing technique is described in a patient with metastatic prostate cancer. An inverse HT plan and an accompanying back-up conventional lateral 6-MV parallel opposed pair (POP) plan with corresponding isodose distributions and dose-volume histograms (DVH) were created and assessed prior to initiation of therapy. Plans conforming to the planning treatment volume (PTV) with significant sparing of brain, optic nerve, and eye were created. Dose heterogeneity to the PTV target was slightly higher in the HT plan compared to the back-up POP plan. Conformal sparing of brain, optic nerve, and eye was achieved by the HT plan. Similar lens and brain stem/spinal cord doses were seen with both plans. Prospective clinical evaluation with relevant end points (quality of life, symptom relief) are required to confirm the potential benefits of highly conformal therapies applied to palliative situations such as this case.

61 RADIATION PROTECTION AND DOSIMETRY↗

Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical Tomotherapy

The purpose of this study was to demonstrate the potential utility of megavoltage fan-beam computed tomography (MV-FBCT) for treatment planning in a patient undergoing helical tomotherapy for nasopharyngeal carcinoma in the presence of extensive dental artifact. A 28-year-old female with locally advanced nasopharyngeal carcinoma presented for radiation therapy. Due to the extensiveness of the dental artifact present in the oral cavity kV-CT scan acquired at simulation, which made treatment planning impossible on tomotherapy planning system, MV-FBCT imaging was obtained using the HI-ART tomotherapy treatment machine, with the patient in the treatment position, and this information was registered with her original kV-CT scan for the purposes of structure delineation, dose calculation, and treatment planning. To validate the feasibility of the MV-FBCT-generated treatment plan, an electron density CT phantom (model 465, Gammex Inc., Middleton, WI) was scanned using MV-FBCT to obtain CT number to density table. Additionally, both a 'cheese' phantom (which came with the tomotherapy treatment machine) with 2 inserted ion chambers and a generic phantom called Quasar phantom (Modus Medical Devices Inc., London, ON, Canada) with one inserted chamber were used to confirm dosimetric accuracy. The MV-FBCT could be used to clearly visualize anatomy in the region of the dental artifact and provide sufficient soft-tissue contrast to assist in the delineation of normal tissue structures and fat planes. With the elimination of the dental artifact, the MV-FBCT images allowed more accurate dose calculation by the tomotherapy system. It was confirmed that the phantom material density was determined correctly by the tomotherapy MV-FBCT number to density table. The ion chamber measurements agreed with the calculations from the MV-FBCT generated phantom plan within 2%. MV-FBCT may be useful in radiation treatment planning for nasopharyngeal cancer patients in the setting of extensive dental artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗