Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Modeling the Ionosphere-Thermosphere Response to a Geomagnetic Storm Using Physics-based Magnetospheric Energy Input: OpenGGCM-CTIM Results

The magnetosphere is a major source of energy for the Earth's ionosphere and thermosphere (IT) system. Current IT models drive the upper atmosphere using empirically calculated magnetospheric energy input. Thus, they do not sufficiently capture the storm-time dynamics, particularly at high latitudes. To improve the prediction capability of IT models, a physics-based magnetospheric input is necessary. Here, we use the Open Global General Circulation Model (OpenGGCM) coupled with the Coupled Thermosphere Ionosphere Model (CTIM). OpenGGCM calculates a three-dimensional global magnetosphere and a two-dimensional high-latitude ionosphere by solving resistive magnetohydrodynamic (MHD) equations with solar wind input. CTIM calculates a global thermosphere and a high-latitude ionosphere in three dimensions using realistic magnetospheric inputs from the OpenGGCM. We investigate whether the coupled model improves the storm-time IT responses by simulating a geomagnetic storm that is preceded by a strong solar wind pressure front on August 24, 2005. We compare the OpenGGCM-CTIM results with low-earth-orbit satellite observations and with the model results of Coupled Thermosphere-Ionosphere-Plasmasphere electrodynamics (CTIPe). CTIPe is an up-to-date version of CTIM that incorporates more IT dynamics such as a low-latitude ionosphere and a plasmasphere, but uses empirical magnetospheric input. OpenGGCMCTIM reproduces localized neutral density peaks at approx. 400 km altitude in the high-latitude dayside regions in agreement with in situ observations during the pressure shock and the early phase of the storm. Although CTIPe is in some sense a much superior model than CTIM, it misses these localized enhancements. Unlike the CTIPe empirical input models, OpenGGCM-CTIM more faithfully produces localized increases of both auroral precipitation and ionospheric electric fields near the high-latitude dayside region after the pressure shock and after the storm onset, which in turn effectively heats the thermosphere and causes the neutral density increase at 400 km altitude.

Connor, Hyunju K.↗

Total Temperature Measurements Using a Rearward Facing Probe in Supercooled Liquid Droplet and Ice Crystal Clouds

Engine Icing Performance loss: rollback, surge, flameout, and even internal engine damagePartial melting and refreeze of ice inside engine core (Mason et al., 2006). Ingestion of ice crystals and aggregates, mixed-phase droplets, or supercooled liquid dropletsNeed to better understand the conditions and properties that lead to engine icing.Simulation and analysis (physical and computational, and modeling)Test facilities (PSL, NRC, ...). Thermal and computational models and analysisProbesMultiple probes (aerothermal probes and ice cloud characterization probes and techniques). Total temperatureTraditional total temperature probes (vented forward facing)Heated total temperature probes (Goodyear). Rearward facing (developmental). Total temperature relevance. Thermal interaction between the icing cloud and air flow impinging particles contribute to kinetic heating effect (Gent et al., 2000). Measurement considerations Temperature sensor accuracy. Incomplete recovery of total temperature. Thermal surfaces (sources and sinks). Flow effects (viscous losses). Debris contamination, including icing and ice ingestion.

Agui, Juan H.↗

Aqueous Alteration

A secondary process whereby liquid water modified the nature of anhydrous primary nebular components. In general, this process induced decomposition and changed the structures and compositions of primary minerals and formed secondary minerals in their place. This process occurred in the early history of meteorite parent bodies that contained water ice. The most effective heat source is considered to be the decay of short-lived radioactive nuclide such as Aluminium-26, but other causes have been suggested. The degree of aqueous alteration of meteorites is categorized as type 1 (most altered) to type 3 (least altered), according to mineralogy and petrology.

Kebukawa, Yoko↗

Modeling Electrolytic Conversion of Metabolic CO2 and Optimizing a Macrofluidic Electrochemical Reactor for Advanced Closed Loop Life Support Systems

The International Space Station (ISS) is currently equipped with a complex, heavy, and power consuming system that recovers approximately 50% of O2 from metabolic CO2. Future long duration missions will require a sustainable and highly efficient system capable of yielding a minimum of 75% O2 recovery. A Macrofluidic Electrochemical Reactor (MFECR) technology development effort is currently underway at NASA Marshall Space Flight Center (MSFC) to significantly increase current O2 recovery efficiency and reduce complexity of the system. This paper presents a comprehensive multi-physic 3D model developed at MSFC on CO2 conversion to O2 and C2H4 at standard conditions via MFECR. The 3D spatial domain of the model is a replica of the actual MFECR’s 3D drawing generated for the MFECR fabrication and operated to recover O2 from CO2 yielding C2H4 as byproduct. Electrochemical (EC) physics that includes EC multicomponent reaction mechanisms, mass transport, and current density distributions is coupled in the model with all the other physics phenomena involved in the process, such as free and porous fluid flow, multicomponent mass transfer, heat transfer, and DC electrical current generation along with Joule heating effect. The authors plan to use experimental results to validate this comprehensive and rigorous model and build a reliable simulator that will not only assist the authors on the MFECR design but also optimize its operation.

Dominguez, Jesus A.↗

Modeling Electrolytic O2 Recovery from Metabolic CO2 for Advanced Closed Loop Life Support Systems in Extraterrestrial Human Missions

The International Space Station (ISS) is currently equipped with a complex, heavy, and power consuming system that recovers approximately 50% of O2 from metabolic CO2. Future long duration human missions to the Moon and Mars will necessitate a sustainable and highly efficient metabolic oxygen recovery system capable of yielding a minimum of 75% O2 recovery. A Macrofluidic Electrochemical Reactor (MFECR) technology development effort is currently underway at NASA Marshall Space Flight Center (MSFC) to significantly increase current metabolic O2 recovery efficiency, expand mission sustainability, and reduce complexity of the system. The novel design combines CO2 conversion to O2 along with C2H4 as byproduct and water electrolysis (currently conducted in two separate units) into a single compact unit that runs at standard conditions and is theoretically capable of generating O2 with a theoretical maximum metabolic CO2 conversion of 73% while consuming less than metabolic water. This paper presents a comprehensive multi-physic 3D model developed at MSFC on CO2 conversion to O2 and C2H4 at standard conditions via MFECR. The 3D spatial domain of the model is a replica of the actual MFECR’s 3D drawing generated for the MFECR fabrication and operated to recover O2 from CO2 yielding C2H4 as byproduct. Electrochemical (EC) physics that includes EC multicomponent reaction mechanisms, mass transport, and electrical current density distributions is coupled in the model with all the other physics phenomena involved in the MFECR’s process, such as two-phase flow, free and porous fluid regimes, multicomponent mass transfer, heat transfer, and DC electrical current generation along with Joule heating effect. The EC reaction sections of the MFECR consists of two porous gas diffusion electrodes (GDE) and an electrolyte serpentine channel sandwiched in the middle. The CO2 feeds the cathode serpentine channel and part of the O2 product is fed back to the anode serpentine chamber. An alkaline solution feeds the electrolyte serpentine chamber wetting the GDEs of both, the anode and cathode allowing the OH- ionic transport between them. The EC reactions in the cathode’s GDE yield C2H4 from CO2 and H2 from water while the EC reaction in the anode’s GDE yields O2. The authors will present in this paper the validation of the model using experimental data and the utilization of the validated model in building a reliable simulator that will not only assist the authors on the MFECR design but also the optimization of its operation in the ISS and future spatial human missions.

Jesus A Dominguez↗

Follow-on studies using the Voyager spacecraft thermal model

The 42-year-old Voyager mission, now named the Voyager Interstellar Mission (VIM) is operating long beyond its design life. In 2012, Voyager 1 crossed the heliopause into interstellar space and Voyager 2 made the same transit in November 2018. Due to declining power output from the Radioisotope Thermoelectric Generators (RTGs) the Science and Flight Operations teams continue to make difficult choices in terms of managing both the power and thermal margins to preserve critical science observations and maintain the health of the two spacecraft. A previous paper, “Creating a Voyager Thermal Model 39 Years Into the Flight Mission, Along With Model Correlation and Application” described how a thermal model of these 1977 spacecraft was developed and correlated without many design artifacts and with limited temperature telemetry. This paper describes how the thermal model has been used to establish an Allowable Flight Temperature (AFT) limit for hydrazine propellant in the propulsion subsystem to minimize the risk of freezing. Voyager 2 temperatures have already descended to this limit in the vicinity of the Roll thruster propellant lines. The Flight Operations team has investigated several ways of detecting propellant freezing based on analysis and trending of thruster performance telemetry. In addition, the Voyager thermal model is being used to predict the spacecraft response to possible changes in power state. These changes could involve turning off outboard science instruments and/or their heaters to increase power margin and hence power dissipation inside the spacecraft bus (i.e. in Bay 7, where the power regulation electronics are located). Changes might also be made to turn on or off other loads inside the bus to more effectively heat the coldest propellant lines.

Medina, Enrique↗

Follow-on studies using the Voyager spacecraft thermal model

The 42-year-old Voyager mission, now named the Voyager Interstellar Mission (VIM) is operating long beyond its design life. In 2012, Voyager 1 crossed the heliopause into interstellar space and Voyager 2 made the same transit in November 2018. Due to declining power output from the Radioisotope Thermoelectric Generators (RTGs) the Science and Flight Operations teams continue to make difficult choices in terms of managing both the power and thermal margins to preserve critical science observations and maintain the health of the two spacecraft. A previous paper, “Creating a Voyager Thermal Model 39 Years Into the Flight Mission, Along With Model Correlation and Application” described how a thermal model of these 1977 spacecraft was developed and correlated without many design artifacts and with limited temperature telemetry. This paper describes how the thermal model has been used to establish an Allowable Flight Temperature (AFT) limit for hydrazine propellant in the propulsion subsystem to minimize the risk of freezing. Voyager 2 temperatures have already descended to this limit in the vicinity of the Roll thruster propellant lines. The Flight Operations team has investigated several ways of detecting propellant freezing based on analysis and trending of thruster performance telemetry. In addition, the Voyager thermal model is being used to predict the spacecraft response to possible changes in power state. These changes could involve turning off outboard science instruments and/or their heaters to increase power margin and hence power dissipation inside the spacecraft bus (i.e. in Bay 7, where the power regulation electronics are located). Changes might also be made to turn on or off other loads inside the bus to more effectively heat the coldest propellant lines. Many of these changes have been or will be tested first on Voyager 1 which has more power margin and does not have the power matrix commanding issues experienced on Voyager 2. Ultimately this assessment may assist the Voyager project in making decisions on the order in which science instruments are permanently turned off.

Medina, Enrique↗

Comprehensive 3D Multiphysics Model on Electrochemical Recovery of O 2 from Metabolic CO 2 at the International Space Station (ISS)

The International Space Station (ISS) is presently equipped with an elaborate, heavy, and high-power consuming system that recovers approximately 50% of O 2 from metabolic CO 2 as part of the atmospheric revitalization (AR) at the ISS habitat. Future long-duration missions will require a sustainable and efficient system capable of yielding a minimum of 75% O 2 recovery to reach the self-sufficiency required for long space missions beyond earth’s low orbit. A Macrofluidic Electrochemical Reactor (MFECR) technology development effort is currently underway at NASA Marshall Space Flight Center (MSFC) to not only increase significantly current O 2 recovery efficiency, improving self-sufficiency on AR at the ISS habitat and future long missions, but also reduce the complexity of the system. The authors have developed and deployed a comprehensive 3D multiphysics model that thoroughly replicates the actual configuration and fluid/material domains of the MFECR. The coupled physics in this multiphysics model include multicomponent-multiphase electrochemical-driven reactions, non-ideal mass transport mechanism, free and porous flow, heat transfer, CO 2 solubility on alkaline electrolyte, water condensation on porous medium, and DC electrical current generation along with Joule heating effect. This model is aimed to conduct quantitive benchmark on three different MFECR’s layouts, one without serpentine paths (plain) and two with serpentines leading to four and twelve paths respectively. Once experimental data is generated via a test matrix of 200 tests, the model will be validated to conduct MFECR’s process optimization and revalidate the quantitive benchmark on three different MFECR’s layouts.

Jesus A. Dominguez↗

Highly Thermally Conductive Hybrid Carbon Fiber Polymer Composite for Radiator Application

Carbon fiber (CF) reinforced polymer composites have been used for aerospace structures because they have low mass, high specific strength, high specific stiffness, and low life-cycle maintenance compared to aluminum alloys. However, due to their relatively low thermal conductivity, pristine CF polymer composites fail to provide effective heat flow for certain applications such as heat exchange systems and radiators. The technology described in this paper provides novel CF polymer composites that possess high thermal conductivity by incorporating pyrolytic graphite sheets (PGS). The thermal conductivities of novel hybrid PGS/CF polymer composites were measured to be about 10 to 30 times higher than that of pristine CF polymer composite, and about two times higher than that of aluminum alloy 6061. This new material with sufficient thermal conductivity is applicable to composite radiators of heat exchange systems.

Thermal Conductivity↗

Assessment of lumen degradation and remaining useful life of LEDs using particle filter

With the development of light-emitting diode (LED) technology, light emitting diodes system is becoming a popular light source in daily life and industry area. It has shown that Led from same factory and work under same working condition, may have significantly different behavior. Therefore, it is very important to learn the fail mechanisms, especially in the case of safety critical and harsh environment application. This paper focus on a prognostic health management (PHM) method based on the measurement of forward voltage and forward current of bare LED under harsh environment. In this paper, experiment has been done with ten samples. Ten pristine bare LEDs have been tested at 85°C while simultaneously being subjected to 85% humid environment. Pulse width modulation (PWM) control method has been employed to drive the bare LED in order to reduce the heat effect caused by forward current and high frequency (300HZ) data acquisition has been used to measure the peak forward voltage and forward current. Test to failure (lumen drops to 70 percent) data has been measured to study the effects of high temperature and humid environment loadings on the bare LED. Also, solid state cooling method with peltier cooler has been used to control the temperature of LED in the integrating sphere when take the measurement of lumen flux. The shift of forward voltage forward current curve and lumen degradation has been recorded to help build the fail model and predicted the remaining useful life. In this method, particle filter has been employed to predict the remaining useful life (RUL) of the bare LED and give us a whole picture how Led system fails. Result shows that predication of remaining useful life of Led, made by the particle filter model works under reasonable limit, and hence this method can be employed to predict the failure of Led caused by thermal and humid stress under harsh environment.

42 ENGINEERING↗

Multi-Physics Analysis of the Fermilab Booster RF Cavity

After about 40 years of operation the RF accelerating cavities in Fermilab Booster need an upgrade to improve their reliability and to increase the repetition rate in order to support a future experimental program. An increase in the repetitio n rate from 7 to 15 Hz entails increasing the power dissipation in the RF cavities, their ferrite loaded tuners, and HOM dampers. The increased duty factor requires careful modelling for the RF heating effects in the cavity. A multi-physic analysis invest igating both the RF and thermal properties of Booster cavity under various operating conditions is presented in this paper.

43 PARTICLE ACCELERATORS↗

Annihilation Signatures of Hidden Sector Dark Matter Within Early-Forming Microhalos

If the dark matter is part of a hidden sector with only very feeble couplings to the Standard Model, the lightest particle in the hidden sector will generically be long-lived and could come to dominate the energy density of the universe prior to the onset of nucleosynthesis. During this early matter-dominated era, density perturbations will grow more quickly than otherwise predicted, leading to a large abundance of sub-earth-mass dark matter microhalos. Since the dark matter does not couple directly to the Standard Model, the minimum halo mass is much smaller than expected for weakly interacting dark matter, and the smallest halos could form during the radiation-dominated era. In this paper, we calculate the evolution of density perturbations within the context of such hidden sector models and use a series of $N$-body simulations to determine the outcome of nonlinear collapse during radiation domination. The resulting microhalos are extremely dense, which leads to very high rates of dark matter annihilation and to large indirect detection signals that resemble those ordinarily predicted for decaying dark matter. We find that the Fermi Collaboration's measurement of the high-latitude gamma-ray background rules out a wide range of parameter space within this class of models. The scenarios that are most difficult to constrain are those that feature a very long early matter-dominated era; if microhalos form prior to the decay of the unstable hidden sector matter, the destruction of these microhalos effectively heats the dark matter, suppressing the later formation of microhalos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Assessment of High-Efficiency Refrigerated Display Cases with Low-GWP Refrigerants: Preprint

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas (GHG) reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison was to assess the energy performance of two high efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513a, respectively. Performance of these display cases were compared to a baseline fixture using HFC (R-134a) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores, and small supermarkets. The high efficiency cases were equipped with energy efficient lighting, improved panel insulation, high efficiency evaporator and condenser fan motors, and high effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions. However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining target product temperature, the energy efficient fixtures containing R-290 and R-513a consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134a refrigerant. The daily energy consumption of the R-290, R-513a, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

High power l-band fast phase shifter

Following successful testing of a concept prototype of a waveguide-based high power phase shifter, a design of a fast, high power device has been developed. The shifter uses two magnetically biased blocks of Yttrium Iron Garnet (YIG) positioned along the side walls of a rectangular waveguide. The cross-section of the waveguide is chosen to suppress unwanted RF modes that could otherwise compromise performance of the phase shifter. Static bias field in the YIG blocks is created by employing permanent magnets. Low inductance coils in the same magnetic circuit excite fast component of the bias field. Design of the device ensures effective heat extraction from the YIG blocks and penetration of the fast magnetic field inside the waveguide with minimum delay. This paper summarizes main steps in this development and gives brief description of the system.

43 PARTICLE ACCELERATORS↗

High performance compact magnetic spectrometers for energetic ion and electron measurement in ultra intense short pulse laser solid interactions

Ultra intense short pulse lasers incident on solid targets can generate relativistic electrons that then accelerate energetic protons and ions. These fast electrons and ions can effectively heat the solid target, beyond the region of direct laser interaction, and are vital to realizing the fast ignition concept. To study these energetic ions and electrons produced from the laser-target interactions, we have developed a range of spectrometers that can cover a large energy range (from less than 0.1 MeV to above 100 MeV). They are physically compact and feature high performance and low cost. We will present the basic design of these spectrometers and their test results from recent laser experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the LCLS Laser Heater and its impact on the x-ray FEL Performance

The very bright electron beam required for an x-ray free-electron laser (FEL), such as the Linac Coherent Light Source (LCLS), is susceptible to a microbunching instability in the magnetic bunch compressors, prior to the FEL undulator. The uncorrelated electron energy spread in the LCLS can be increased by an order of magnitude to provide strong Landau damping against the instability without degrading the FEL performance. To this end, a 'laser-heater' system has been installed in the LCLS injector, which modulates the energy of a 135-MeV electron bunch with an IR laser beam in a short undulator, enclosed within a four-dipole chicane. In this paper, we report detailed measurements of laser heater-induced energy spread, including the unexpected self-heating phenomenon when the laser energy is very low. We discuss the suppression of the microbunching instability with the laser heater and its impact on the x-ray FEL performance. We also present the analysis of these experimental results and develop a three-dimensional longitudinal space charge model to explain the self-heating effect.

43 PARTICLE ACCELERATORS↗

Effect of Solution Heating Rate on Quasi-static and Dynamic Mechanical Properties of Al-Mg-Si-Cu Alloy

The effect of solution heating rate on quasi-static and dynamic mechanical properties of Al-Mg-Si-Cu alloy in bake hardening state was investigated through mechanical properties, microstructure and fracture morphology characterization in the present study. The results show that solution heating rate has a strong influence on microstructure, quasi-static and dynamic mechanical properties. As solution heating rate rises, the grain microstructure transforms from the elongated grains to equiaxed grains and the fraction of low-angle grain boundaries (LAGBs) also decreases. Moreover, the equivalent average grain size first decreases, and then increases. The relationship between solution heating rate and mechanical property is monotonic, not depending on strain rate. As solution heating rate rises, the yield strength, ultimate tensile strength and elongation decrease. In contrast to quasi-static loading, dynamic loading always tends to improve strengths and elongation. In addition, compared with the quasi-static tensile specimens, the dynamic tensile specimens possess a larger number of dislocations. Regardless of strain rate and solution heating rate, all the tensile specimens exhibit the ductile fracture mode. As solution rate rises, the dimples decrease and become shallow gradually. The dimples in dynamic fracture zone are larger and deeper than those in the quasi-static fracture zone.

36 MATERIALS SCIENCE↗