Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Fast Modular Reactor (FMR): Overview and Conceptual Design Work

The conceptual design of the FMR including the experimental and numerical verifications will lead to: Cost estimation of the FMR based on the conceptual design results and guidelines of advanced reactor construction. Submittal of the pre-application licensing plan to the NRC for review and feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Amendment to Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on History Preservation Concerning Management of the Historic Properties of Los Alamos National Laboratory, Los Alamos, New Mexico (AGREEMENT)

The Field Office has a cultural resources program manager. The LANL Management and Operating Contractor has a staff of cultural resource specialists who meet the qualifications set forth in the Secretary of the Interior's Standards and Guidelines for Professional Qualifications (36 CFR Part 61), or work under the supervision of individuals who meet these qualifications. Any future Management and Operating Contractor will have a staff of Secretary of the Interior-qualified cultural resource specialists.

99 GENERAL AND MISCELLANEOUS↗

VERAIn Programmer's Manual

This document provides information needed by developers who will be working in the VERAIn source code. It provides a high-level overview of input design, as well as guidelines for adding new inputs.

97 MATHEMATICS AND COMPUTING↗

Multi-Variable Parametric Analysis of Prototype Building Energy Performance Using Current and Future Weather Scenarios For Data-Driven Market Transformation Support

This project aimed to develop a public building simulation data set that may be used to inform building code development and guidelines for building innovation. The data set consists of several common building types and many representative locations across the United States. A parametric design of building properties was developed to create a range of building energy models that represent common building design decisions with a particular focus on fenestration options. The US Department of Energy prototype building energy models were altered according to a parametric building design and simulated using both current weather data and future weather estimates derived from global climate models. The resulting data set allows for pertinent exploration of building design parameters, including fenestration, within different environments across the United States in the broader context of climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2021

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2021. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 Version 4.1 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

The Role of Grain Boundary Structure and Chemistry in Materials Failure

The objective of this project was to reveal how we can design materials with a tunable mechanical behavior through interface engineering. To do so we focused on understanding slip transmission across internal surfaces and how it relates to the strength and chemistry of the internal surface. In doing so we followed an interdisciplinary approach that employed theory, experiments and molecular dynamic (MD) simulations. Our guideline was that interfaces are characterized by their own mechanically induced interface parameter. New dislocation-grain boundary interaction mechanisms were revealed and the strengthening effects of non-traditional interfaces. We began studying simple grain boundaries in Fe systems, and then moved on to newly explored systems such as graphene-metal and nanolayer composites.

36 MATERIALS SCIENCE↗

Release of Contaminants from Burning Liquids and Solids

This report details model development, theory, and a literature review focusing on the emission of contaminants on solid substrates in fires. This is the final report from a 2-year Nuclear Safety Research and Development (NSRD) project. The work represents progress towards a goal of having modeling and simulation capabilities that are sufficiently mature and accurate that they can be utilized in place of physical tests for determining safe handling practices. At present, the guidelines for safety are largely empirically based, derived from a survey of existing datasets. This particular report details the development, verification and calibration of a number of code improvements that have been implemented in the SIERRA suite of codes, and the application of those codes to three different experimental scenarios that have been subject of prior tests. The first scenario involves a contaminated PMMA slab, which is exposed to heat. The modeling involved a novel method for simulating the viscous diffusion of the particles in the slab. The second scenario involved a small pool fire of contaminated combustible liquid mimicking historical tests and finds that the release of contaminants has a high functionality with the height of the liquid in the container. The third scenario involves the burning of a contaminated tray of shredded cellulose. A novel release mechanism was formulated based on predicted progress of the decomposition of the cellulose, and while the model was found to result in release that can be tuned to match the experiments, some modifications to the model are desirable to achieve quantitative accuracy.

54 ENVIRONMENTAL SCIENCES↗

Documentation on How to Run the NEAMS Workbench GUI on Sawtooth

This document provides guidelines on how to run Moose-based applications from the NEAMS WorkbenchGUI on the HPC platform Sawtooth located at Idaho National Laboratory. The different steps are illustrated with a multi-app example modeling a sodium-cooled fast reactor (SFR) taken from the virtual test bed (VTB) website. The workflow consists of four steps to demonstrate the capabilities of the NEAMS Workbench GUI, that covers log into Sawtooth, editing and validating input files, submission of the job to the queue and visualization of the numerical solution and the geometry. Each step is illustrated with figures in the text, and a demonstration video is also available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Knowledge Transfer and Training in Safeguards for Decommissioned Nuclear Facilities (Project Final Report for FY2022)

The International Atomic Energy Agency (IAEA) applies safeguards to nuclear facilities that are not operating, including those undergoing decommissioning, and the IAEA’s effort in this area is both considerable and increasing. Specifically, the IAEA Department of Safeguards’ Division of Concepts and Planning (SGCP-003: Safeguards Approaches) identified an R&D need to “Develop safeguards implementation guidelines for facilities under decommissioning and safeguards concepts for post-accident facilities under decommissioning”. Nuclear facilities undergoing decommissioning are not exempt from safeguards agreements between the IAEA and Host State, and, accordingly, the requirement for verification of no diversion of nuclear material and detection of undeclared activities at decommissioned facilities remain even after facility shutdown. However, the effort required to meet safeguards objectives diminishes as nuclear material and essential equipment are removed during the decommissioning process which shifts the emphasis from verification of ever-diminishing fissile or source material inventories to verification of changes in facility design and equipment operability.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

AERMOD Screening Dispersion Factors for INL Facilities

This engineering calculations and analysis report (ECAR) documents the calculation of screening level air dispersion factors (DFs) for use in identifying Idaho National Laboratory (INL) air pollutant sources that would not be of concern relative to state of Idaho Department of Environmental Quality (DEQ) significant impact levels for toxic air pollutants (IDAPA 2020). A DF (in units of s/m 3 ) is the maximum time-averaged model-predicted air concentration (g/m 3 ) at an ambient-air receptor location divided by a unit source release or emission rate (1 g/s). DFs were calculated for a generic pollutant released from facilities at the INL Site and the Idaho Falls Research Education Campus (REC) using the Environmental Protection Agency (EPA)-recommended AERMOD air-dispersion model (EPA 2019a) and site-specific meteorological data. The use of AERMOD for air quality analyses is specified by EPA in Appendix W of 40 CFR Part 51, Guideline on Air Quality Models, and by DEQ in their air modeling guidance (DEQ 2013). DFs were calculated for 1-hour, 3 hour, 8-hour, 24-hour, monthly, and annual averaging times.

99 GENERAL AND MISCELLANEOUS↗

Quantifying Thermal Output of Energetic Materials (LDRD Final Report)

We present the results of an LDRD project, funded by the Nuclear Deterrence IA, to develop capabilities for quantitative assessment of pyrotechnic thermal output. The thermal battery igniter is used as an exemplar system. Experimental methodologies for thermal output evaluation are demonstrated here, which can help designers and engineers better specify pyrotechnic components , provide thermal output guidelines for new formulations, and generate new metrics for assessing component performance and margin given a known failure condition. A heat-transfer analysis confirms that the dominant mode of energy transfer from the pyrotechnic output plume to the heat pellet is conduction via deposition of hot titanium particles. A simple lumped-parameter model of titanium particle heat transfer and a detailed multi-phase model of deposition heat transfer are discussed. Pyrotechnic function, as defined by "go/no-go" standoff testing of a heat pellet, is correlated with experimentally measured igniter plume temperature, titanium metal particle temperature, and energy deposition. Three high-speed thermal diagnostics were developed for this task. A three-color imaging pyrometer, acquiring 100k images per second on three color channels, is deployed for measurement of titanium particle temperatures. Complimentary measurements of the overall igniter plume emission ("color") temperature were conducted using a transmission-grating spectrograph in line-imaging mode. Heat flux and energy deposition to a cold wall at the heat-pellet location were estimated using an eroding thermocouple probe, with a frequency response of ~5 kHz. Ultimate "go/no-go" function in the igniter/heat-pellet system was correlated with quantitative thermal metrics, in particular surface energy deposition and plume color temperature. Titanium metal-particle and plume color temperatures both experience an upper bound approximated by the 3245-K boiling point of TiO 2 . Average metal-particle temperatures remained nearly constant for all standoff distances at T = 2850 K, ± 300 K, while plume color temperature and heat flux decay with standoff—suggesting that heat-pellet failure results from a drop in metal-particle flux and not particle temperature. At 50% likelihood of heat-pellet failure, peak time-resolved plume color temperatures drop well below TiO 2 boiling to ~2000 - 2200 K, near the TiO 2 melting point. Estimates of peak heat flux decline from up to 1 GW/m 2 for near-field standoffs to below 320 MW/m 2 at 50% failure likelihood.

36 MATERIALS SCIENCE↗

Container Evaluation: Analysis of the Swagelok Knuckle with Viewport as an Approved Hermetically Sealed Inner Container

This report outlines the results from the water ingress test, helium leak test and additional atmosphere testing for the Swagelok knuckle with viewport container further referred to as the SKV. This container is constructed from a standard union vacuum fitting, 1.33” conflat to 0.5” male VCR, a 1.33” conflat fused silica lensed viewport fitting, and a 0.5 inch VCR cap. The primary intended use of this container is to store Pu metal samples in the vault for a time interval exceeding 40 years. The samples need to be contained in an air free environment to ensure that the material does not oxidize over time. The container viewport is a critical design feature that will help the operators visually inspect and evaluate the state of the metal samples prior to opening the container. These containers are advertised as leak tight, but experimental tests were performed to test the water resistant criteria and the gas leaking criteria set forth by the TA-55 Criticality Safety Program. The results of the water ingress test show that the container is water-tight, with no signs of water penetrating the container within the required guidelines outlined in TA55-AP-522. The preliminary He leak test performed demonstrate that the conflat window port and VCR cap are able to maintain a hermetic seal. Additionally, all containers will be He leak tested independently by the manufacturer prior to shipping to LANL. A third voluntary test was added to assess the container’s ability to hold atmosphere, with successful results indicating the container is able to hold inert atmosphere to prevent lanthanum metal oxidation. It is the conclusion of the authorsthat there is enough evidence through the test conducted and outlined within this document that the proposed container meets the definition of a water-tight container, and it is able to provide a hermetic seal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Entropy Ceramic Coatings: Transformative New Materials for Environmentally-Compatible Thin-Film Insulators against High-T Molten Salts

An emerging new class of promising materials, High-Entropy Ceramics (HECs) or Compositionally-Complex Ceramics (CCCs), have been successfully fabricated in the last three years. This project evaluates HECs/CCCs in the concentrated solar power (CSP) context. In this project, we have identified a couple of simple, and key descriptors governing thermal conductivity in HECs. Size disorder among the cations was found to have a strong influence on the thermal conductivity across multiple systems and throughout a vast compositional space. Since identifying this, we have optimized previous compositions to achieve low thermal conductivities of $k$~$1-1.4Wm{-1}K{-1}$. We have further reduced our selection of promising compositions based on project guidelines and applied a theory that can potentially predict reactivity with molten salts to identify a small set of HECs that are suitable for further molten salt heat transfer media (HTM) stability testing. Many compositions reveal poor resistance to molten chloride salt after being exposed for 24 h compared to the reference structural alloy, Haynes 230. However, after 100 h, a few HECs/CCCs show strong parabolic rate constant effects and provide greater resistance to chloride salt compared to Haynes 230 alloy, which shows more linear kinetics. Postmortem characterization of the microstructure reveals the parabolic rate constant originates from a dense reaction layer form at the interface. This feature is absent in Haynes 230, which only shows grain boundary infiltration. The HECs/CCCs were also put in contact with the metal alloy under Ar for 800 h at 800°C and show negligible interaction. Lastly, parabolic rate constant HECs/CCCs also have low thermal conductivity $(<2 Wm^{-1} K^{-1})$ at 800°C. These specimens satisfy all project requirements and demonstrate their promising application in next-generation CSP.

14 SOLAR ENERGY↗

Innovative Method for Welding in Generation 3 CSP to Enable Reliable Manufacturing of Solar Receivers to withstand Daily Cycling at Temperatures Above 700°C (Final Technical Report)

Inconel® Alloy 740H® (alloy 740H) was the first age-hardenable nickel-based alloy approved by the ASME Boiler & Pressure Vessel Code for use in pressure-boundary applications. Over the past ~20 years the alloy has been optimized for weldability and high-temperature stability, approved for use in different applications. Development of a supply chain combined with the advantageous properties of the alloy (high-temperature creep strength, oxidation and corrosion resistance, etc.) have resulted in the alloy being applied to new high-temperature power cycle demonstration projects, and of particular interest are applications to concentrating solar power (CSP) to enable higher-efficiency Generation 3 CSP systems and the corresponding supercritical CO 2 (sCO 2 ) power cycle components (heat exchangers, piping, etc.). The high allowable stresses of alloy 740H also make it a desirable material for current Generation 2 CSP solar power receivers to improve cyclic capability and/or reduce receiver height. Recent experiences in demonstration projects utilizing alloy 740H identified cracking issues during welding and fabrication. In this project, a detailed study was done to confirm and clarify the Stress Relaxation Cracking (SRxC) mechanism, also known as stress relief cracking or strain-age cracking (SAC), during post-weld heat-treatment (PWHT). This involved detailed microscopy and advanced characterization to understand the root cause(s) of three failures obtained from industry. Based in-part on these findings, a targeted laboratory based SRxC test method was utilized to evaluate variables such as heat-to-heat variations, strain level, PWHT temperature, and starting material condition on three heats of alloy 740H. Industrial shop welding of cold-worked plates was also conducted. The research showed the following: SRxC was confirmed as the cracking mechanism for all field failures; Stress state (from residual stresses, constraint, deformation, and local stress concentrations) was playing a significant role in field failures and laboratory testing confirmed increasing susceptibility for all heats with increasing strain levels. High levels of microstructural strain were identified at crack initiation locations, in some cases leading to local recrystallization; Precipitate free zones (PFZs) at grain boundaries were found at relaxation cracks and crack initiation locations uniquely associated with SRxC in alloy 740H. Laboratory testing reproduced this microstructural feature which had only previously been reported in long-term creep testing of weldments. Advanced nano-scale characterization confirmed the presence of a moving boundary leading to coarsening of precipitates and PFZs where damage accumulated; The research suggested heat-to-heat variations due to local chemistry and processing may influence SRxC susceptibility, but more work is needed to fully clarify these effects. To disseminate the key learnings from this research to the scientific and engineering communities and alloy 740H end users, multiple technical publications and presentations were made, an industrial alloy 740H users meeting was held, and a new industry guideline specification document which can be directly implemented by end-users of alloy 740H was produced.

14 SOLAR ENERGY↗

Hearing Loss and Dementia

This report is an OSH-DO Safety Action Bulletin that briefly discusses the link between dementia and hearing loss. The bulletin provides some basic statistics, hearing loss protection guidelines and resources for more information on the topic.

99 GENERAL AND MISCELLANEOUS↗

Simulation, Challenge Testing & Validation of Occupancy Recognition & CO 2 Technologies (Final Project Report)

This final report covers the results of the development of testing methods of occupancy sensor systems connected to HVAC controls. This project focused on the development of test methods to evaluate the performance of HVAC-connected occupancy sensor systems, including occupancy presence, occupancy counting, and CO 2 sensor systems in commercial and residential buildings. This included evaluation of the reliability, ease of commissioning, and energy savings potential of these sensor systems. The results of this work help to standardize the methods used to evaluate performance, to enable the ability to compare sensor system performance following the same methods, to understand which sensor systems perform better or worse compared to others. The U.S. building stock’s energy usage can benefit substantially from having building system operations informed by reliable occupancy recognition and CO 2 measurements, however to date, standard methods have not been in place to ensure that sensor systems’ reported performance is uniformly evaluated. The results of this work support the development of a standard or guideline that outlines the developed methods of testing. This project also included the testing of both off-the-shelf and novel SENSOR team-developed low-cost occupancy sensor systems, using the developed methods of testing. The results of this testing helped to inform further development and improvement of new low-cost sensor systems that will benefit from being used in residential and commercial buildings throughout the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗