Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Commissioning & Characterization of Magnetized Gridded Thermionic Electron Source

Collaborative efforts to design and fabricate a magnetized gridded thermionic electron source have been conducted between Xelera and Jefferson Lab. Commissioning and characterization of an electron gun fabricated by Xelera was performed to benchmark the viability of future electron source designs and capabilities. The work involved simulation, installation, trouble-shooting, modifications of the design, commissioning, characterization, and magnetization of the electron beam produced. A specially designed cavity as well as novel diagnostic tools and methods were developed, implemented, and experimentally tested. Finally, the gun was used to demonstrate a previously unachieved current of magnetized electron beam from a gridded thermionic source of this uniquely compact size. This thesis addresses the following scientific and technological challenges: building a compact gridded thermionic electron source, producing high current magnetized electron beam, and demonstrating novel characterization measurements for magnetized beam.

Stefani, Mark↗

Storage Requirements for Grid Integration of Marine Renewable Energy - a Parametric Study

Marine resources such as waves and tides house immense potential to serve as energy-rich sources of renewable power generation. They are known to be highly available,persistent and predictable in nature. Therefore, these can serve as one of the critical components for a primarily renewable energy-driven, resilient and robust future power grid. Although some inherent temporal characteristics of these resources lend themselves favorably to potential grid applications, the inclusion of storage allows the benefits and value streams to become realized more fully. In this paper, we present a framework for assessing impact of marine energy resources inclusion on the overall load generation balance and its impact on the relevant storage requirements to obtain the desired level of renewable energy penetration. From this study, we can critically infer two main points - (a) the relative storage requirements for grid operations with and without marine energy, and (b) the avoided cost of storage by including marine energy into the generation mix. We demonstrate our framework for two different locations across the United States.

Hanif, Sarmad↗

Semantic Interoperability to Enable Smart, Grid-Interactive Efficient Buildings

Achieving a widespread transition to grid-interactive, efficient buildings (GEBs) depends critically on there being sufficient interoperability among connected building systems. While many critical elements already exist at the technical interoperability level (TCP/IP, BACnet, etc.), a lack of interoperability in the semantic level hinders streamlined integration of interdependent applications. Semantics refers to expressing information about “things” in a way that can be consistently understood by applications. Key components of formalized semantics include identifying what a “thing” is (its “type”), defining general information about that “thing” (its characteristics or properties), and defining the appropriate relationships of that “thing” to other “things” (its function or role in a larger system). Although this might seem initially trivial, the success of smart building applications is highly dependent on maintaining consistent self-descriptive notions of the “things”. Without semantic interoperability, it is technically difficult, labor-intensive, and cost-prohibitive to enable three key objectives of GEBs: optimizing performance, automatically identifying and diagnosing faults, and delivering grid services. Industry, academia, and standards bodies have invested effort in developing information models to facilitate semantic interoperability, however, they have not been widely adopted across the U.S. commercial building portfolio. This paper will present a pathway to drive semantic interoperability through a three-pronged approach to be led by the DOE Building Technologies Office in partnership with NIST and multiple national laboratories comprising: 1) industry engagement and coordination across existing efforts; 2) a semantic interoperability standard that empowers building owners to identify and require interoperable attributes when procuring equipment and applications; 3) tools to assist in implementation and a test framework to verify compliance of products with semantic interoperability specifications. This approach is designed to accelerate the timeline for adoption of semantic interoperability specifications. The intent is to reduce soft costs associated with implementing advanced controls, fault detection and diagnostics, and other smart building technologies and use cases as a necessary step in achieving an energy efficient smart grid future.

30 DIRECT ENERGY CONVERSION↗

Probabilistic Day-Ahead Forecasting Using an Analog Ensemble Approach for Wind Farm Grid Services

Wind resource assessment and wind power forecasting are used in research and industry to anticipate future power output at scales ranging from individual wind turbines to entire wind farms. Probabilistic day-ahead wind forecasting is useful for anticipating how a wind farm could potentially participate in the day-ahead market by providing upper and lower bounds for expected power generation, thus informing grid operators of its uncertainty. Understanding this uncertainty is part of a larger project focused on building a platform that combines efforts in weather forecasting, aerodynamic and economic modeling to create maximum value of a wind plant to better provide services to the grid. This effort is also known as the Atmosphere to Electrons to Grid (A2E2G) project. One method for producing a probabilistic forecast is through the analog ensemble approach (Delle Monache et al., 2011). This method leverages historical forecasts and their corresponding observations as a training data set from which future forecasts can be made. For some future forecast, the most similar historical forecasts (analogs) are identified on a regular time basis such as once per a 3-hour window. The most similar analogs, based on a metric such as root mean square error (RMSE), are recorded and their corresponding verifying observations are used as an ensemble member for this future forecast. Prior work in this area demonstrates improvements over raw Numerical Weather Prediction (NWP) forecasts and shows skill similar to techniques such as logistic regression and machine learning (Delle Monache et al., 2013; Alessandrini et al., 2015). Here, we take the High-Resolution Rapid Refresh model (HRRR) day-ahead forecast (0-36 hours) to create a probabilistic day-ahead forecast using an analog ensemble approach. The HRRR has an hourly temporal resolution, with a spatial resolution of 3 km. The 12 UTC HRRR model run is downloaded every day for one year from August 2019 - July 2020, with the first 11 months serving as a bank of analogs from which the forecasting algorithm can create a probabilistic forecast. Once downloaded, the original HRRR forecast is temporally interpolated to 5-minutes, aligning with both the temporal resolution of the observations as well as the timescale relevant for day-ahead power forecasts. The forecast is validated at the M2 tower at the Flatirons Campus of the National Renewable Energy Laboratory (NREL) at a typical wind turbine height of 80 m. Variables such as wind speed, wind direction, and turbulence intensity are incorporated into the probabilistic forecast model and weighted according to their relative importance to the forecast. Based on metrics such as mean bias error (MBE), mean absolute error (MAE), and root mean square error, the analog ensemble forecast outperforms the raw HRRR forecast during the testing period of July 2020. Figure 1 illustrates an example day-ahead forecast compared against the verifying observations. The general variability and ramps are captured throughout the day, with potential to further improve the analog ensemble model through machine learning techniques.

numerical weather prediction↗

A Privacy-Preserving Strategy for the Trust Layer of the Energy Grid of Things Distributed Energy Resource Management System

Emergent from the shadows of the traditional grid flaws, the Smart Grid (SG) idea was born and led by government mandates toward cleaner energy production. The SG represents the next generation of electricity distribution systems that subsume recent technological innovations. It uses digital communication between its components and entities to attain more automation, self-sufficiency, and reliability. Unfortunately, this relatively new concept is not flawless; the intrinsic reliance on increased digital communication spreads open attack paths for adversaries. Therefore, finding solutions that address information exchange vulnerabilities has become imperative. The Energy Grid of Things (EGoT) is Portland State University’s (PSU’s) implementation of a Distributed Energy Resource Management System (DERMS). The EGoT DERMS requires access to customers’ information to achieve operational objectives. The system’s access to customers’ information needs to be restricted such that it does not violate customers’ privacy. Applying privacy protection models such as K-anonymity to EGoT DERMS sub-components safeguards that privacy. This thesis work proposes a strategy to ensure communication in the EGoT DERMS is privacy-preserving and secure. Specifically, it provides an approach to applying the Mondrian Algorithm to ensure data within the system excludes Personally Identifiable Information (PII) and provides means for securing the communication according to industry standards (IEEE 2030.5). Results suggest that the generalization hierarchy derived for the EGoT DERMS exhibits an Identical Generalization Hierarchy structure. Guarantees of sameness manifested in the test feeder topology would not hold in real-world scenarios. This thesis work proposes a strategy to ensure communication in the EGoT DERMS is privacy-preserving and secure. Specifically, it provides an approach to applying the Mondrian Algorithm to ensure data within the system excludes Personally Identifiable Information (PII) and provides means for securing the communication according to industry standards (IEEE 2030.5). Results suggest that the generalization hierarchy derived for the EGoT DERMS exhibits an Identical Generalization Hierarchy structure. Guarantees of sameness manifested in the test feeder topology would not hold in real-world scenarios.

Alsiad, Mohammed↗

Charting Hydropower's Role in the Next-Generation Grid

To build a 100% clean energy power sector, the United States is adding more energy storage and variable renewable energy sources, like solar power and wind energy, to the grid. Hydropower and pumped storage hydropower (PSH) can help with both. These technologies already play a key role in providing flexible, low-carbon electricity to the U.S. power grid, and this role will become even more valuable as that grid evolves. That's why researchers at the National Renewable Energy Laboratory (NREL) are analyzing how the U.S. electricity sector could invest in hydropower and PSH using new data and modeling capabilities.

HYDRO ENERGY↗

Methods and systems for evaluating and improving distribution-grid observability

This document describes systems and techniques for evaluating and improving distribution-grid observability. These systems and techniques allow engineers to quantify the observability of a distribution grid, which represents an ability to combine actual measurements and various types of computations (e.g., analytics, estimators, forecasters), from a system model. Distribution engineers can also identify islands of observability where operating parameters, including voltages, currents, and power flows, can be determined from available sensor readings. By exclusion, distribution engineers can similarly identify areas of the distribution grid with observability deficiencies that may require additional instrumentation to maintain proper operation. Distribution engineers, using an iterative or automated process, can determine the observability of the system model with new or relocated sensors to generate a sensor allocation plan. The sensor allocation plan can indicate the number and location of sensors to either maximize observability for a fixed sensor cost or minimize sensor cost for predetermined observability.

Reiman, Anthony P.↗

System and method for liquid crystal display system incorporating wire grid polarizers for large scale and large volume stereolithography

The present disclosure relates to a liquid crystal display (LCD) system. The system in one example has a light source for generating unpolarized light, and an LCD screen arranged in a path of transmittance of the unpolarized light. First and second wire grid polarizers are arranged adjacent to the LCD screen and each have a plurality of nano-scale wires, with the first and second wire grid polarizers have differing polarizations. A pitch of each of the nano-scale wires is no larger than one-third a wavelength of the unpolarized light from the light source. The wire grid polarizers create, in connection with operation of the LCD screen, a 2D light mask suitable for initiating the polymerization of an optically curable material.

Duoss, Eric B.↗

Reconfiguration of power grids during abnormal conditions using reclosers and distributed energy resources

Apparatus and methods are disclosed for restoring operation of a power grid comprising a plurality of reclosers and distributed energy resources (DERs) responsive to abnormal conditions by determining and implementing a reconfiguration for the power grid. The reconfiguration can specify respective new statuses for one or more of the reclosers and/or respective quantities of reactive power to be supplied by one or more of the DERs. The reconfiguration can be determined based on a plurality of constraints using an objective function, the constraints being determined based at least in part on recloser status data and/or DER power generation capability data. Respective cleared quantities of reactive power for the DERs to supply to the reconfigured power grid can be determined via a transactive control scheme, and the reconfiguration can be updated prior to implementation based on the results of the transactive control scheme.

Radhakrishnan, Nikitha↗

System, method, and computer-accessible medium for remote sensing of the electrical distribution grid with hypertemporal imaging

An exemplary system, method, and computer-accessible medium for determining a property(ies) regarding an electrical grid(s) can be provided, which can include, for example, receiving a video(s) of the electrical grid(s), determining a flicker(s) in the electrical grid(s) based on the video(s), and determining the property(ies) based on the flicker(s). The flicker(s) can be a 120 Hertz flicker. The flicker(s) can be a flicker in a light(s) recorded in the video(s). A frequency and a phase of the flicker(s) can be determined.

Bianco, Federica B.↗

Grid Strength Analysis for Integrating 30 GW of Offshore Wind Generation by 2030 in the U.S. Eastern Interconnection: Preprint

Offshore wind is a key player in the transition to a decarbonized electric gird, and the United States has set ambitious goals of integrating 30 GW of offshore wind capacity by 2030 and 110 GW by 2050. To facilitate this integration, the National Renewable Energy Laboratory and the Pacific Northwest National Laboratory are conducting the Atlantic Offshore Wind Transmission Study to assess transmission solutions. To achieve the 110-GW target by 2050, meticulous planning for network expansion and resource allocation is essential; however, meeting the 2030 goals requires integrating offshore wind power with minimal system upgrades, thus necessitating a careful study of grid strength and stability. The study team developed the Grid Strength Analysis Tool (GSAT) to assess system strength under various operating conditions and contingencies, focusing on the proposed integration of 30 GW of offshore wind power by 2030. In this paper, we provide a summary of key features of the GSAT software and results of the grid strength analysis for integrating 30 GW of offshore wind generation by 2030 in the U.S. Eastern Interconnection.

Automated System-wide Strength Evaluation Tool (AS↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Grid-connected heat pump water heater benefits for low-income households in the Southeastern United States

Energy efficient heat pump water heaters (HPWHs) reduce customer energy costs; grid-connected controls further increase HPWH value by enabling energy storage and shifting demand to cheaper, off-peak periods. However, a HPWH’s first cost premium can put it out of reach for low-income customers. This paper will present results of an ongoing study exploring the benefits of load shifting HPWHs for 24 low-income households, aiming to support increased product deployment in this demographic. The study uses EcoPort modules to shift HPWH load for a study sample consisting primarily of low-income adults and seniors in North Carolina. Building upon prior studies, the study’s HPWH operating schedules are designed to maximize shifted energy and minimize participant electricity costs based on local time-of-use rates. The study documents load profiles of grid-connected HPWHs in a less-studied demographic group and explores how certain groups may have particularly flexible loads due to their unique usage profiles. The results are relevant for HPWH product performance in the Southeast. The study will quantify HPWH load shifting performance during North Carolina’s hot summer, temperate shoulder, and occasionally sub-freezing winter seasons, and the study includes installations in conditioned, semi-conditioned, and unconditioned spaces. Finally, study results will also explore how controlled HPWHs can provide value to the regional grid by reducing seasonal peaks via demand response. Lessons learned include HPWH acceptance for low-income and senior users, best practices for maintaining HPWH connectivity among users without prior product experience, and strategies to leverage remote monitoring to ensure optimal operation and enhance HPWH reliability.

Urigwe, Daniela↗

Cybersecurity Considerations and Research Pathways for Grid-Interactive Efficient Buildings

Federal facilities serve critical missions and functions that require safe, reliable, and efficient operations. Digitization of several facility operations has increased the cost-effectiveness of energy usage and optimization of energy system performance. As the building controls landscape shifts to become more connected and smarter, building operators now face unique opportunities and challenges to adopt smart enabled devices that can lower energy usage while also optimizing building system performance. The grid-interactive efficient buildings (GEB) initiative aims to make buildings cleaner and more flexible through these smart devices. Smart enabled devices allow greater connectivity and control through remote operations and provide crucial data for analytics and increased efficiency. GEBs enable demand flexibility that has the potential to reduce electrical costs and transform the grid edge where buildings connect to power grids. This operation of interconnected systems, if not designed with cybersecurity practices, causes security gaps and introduces potential attack paths by adversarial and non-adversarial entities leading to disruption of operations.

building controls↗

Best Practices for Resilience in Smart Grid-Interactive Efficient Buildings

The Federal Energy Management Program (FEMP) supports federal agencies' energy decisions with information and guidance on design, funding, and operations to ensure federal buildings are efficient and resilient. The modernization of building infrastructure and the evolution of buildings to support decarbonization involves complex implementation of multiple components across several systems. This includes energy-efficient equipment, on-site energy generation and storage systems, and control systems. These systems have operational modes that can operate more efficiently if they are able to behave responsively to the conditions of the electrical grid. These grid-interactive efficient buildings (GEB) allow facilities to manage power demand according to operational constraints and market signals issued by grid operators. With proper design and planning, these same capabilities have the potential to enable building and facility resilience - coordinating with microgrids, maintaining power on critical circuits to sustain essential operations, and monitoring building health and safety status during an outage. By managing the load of buildings, GEBs can also reduce the cost of backup generation and make better use of renewable power sources on site. This document outlines some of the processes and considerations to guide the design and operation of GEBs in ways that promote facility resilience.

building decarbonization↗

Leveraging PHIL for Inverter Functionality Requirement Evaluation to Ensure a Reliable Grid

This presentation showcases NREL's ongoing research on advanced Multi-point Power Hardware-in-the-Loop (PHIL) systems, enabling comprehensive evaluation of interoperability, stability, and wide-area stability in complex power grids. Key features include high-power PHIL capabilities, seamless PHIL Interfaces for effortless Grid-Following (GFL) and Grid-Forming (GFM) mode switching, and advanced multi-domain PHIL/Controller Hardware-in-the-Loop (CHIL) capabilities for evaluating diverse technology mixes, facilitating rigorous testing and validation of emerging power systems for reliable integration, enhanced resilience, and optimal performance.

lab capabilities↗

Distribution Grid Incentive Design with Unknown Agent Behavior

Motivation: During extreme events, traditional grid regulation methods (e.g., energy prices, net power injection limits) may be insufficient. While system operators typically lack control over end-user grid interactions, (e.g., energy demand), incentives can influence behavior - for example, a user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. Problem: Optimize for the best incentive subject to system stability constraints. However, user behavior is unknown to the SO - i.e., for a given incentive, the amount of curtailed load or control variables exposed is unknown.

feedback based control↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗