Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Multiscale simulation of integrated energy system and electricity market interactions

Accelerating the deep decarbonization of the world's electric grids requires the coordination of complex energy systems and infrastructures across timescales from seconds to decades. Here, we present a new multiscale simulation framework that integrates process- and grid-centric modeling paradigms to better design, operate, and control integrated energy systems (IESs), which combine multiple technologies, in wholesale energy markets. Traditionally, IESs are analyzed with a process-centric paradigm such as levelized cost of electricity (LCOE) or annualized net revenue, ignoring important interactions with electricity markets. This framework explicitly models the complex interactions between an IES's bidding, scheduling, and control decisions and the energy market's clearing and settlement processes, while incorporating operational uncertainties. Through two case studies, we show the importance of understanding and quantifying complex resource-grid interactions. In case study 1, we demonstrate that optimized bidding from one resource shifts the profit distribution for all energy systems in the market. This result suggests new and more flexible IES technologies can disrupt the economics of all market participants, possibly leading to accelerated retirements of less flexible resources. Interestingly, the optimized bidding has little impact on grid-level aggregate statistics, such as total generation costs and renewable penetration rate. While aggregate modeling strategies may remain valid under some IES adoption scenarios for analysis focused on regional outcomes, direct comparisons of IES technologies at specific locations without considering these interactions may lead to misleading or incorrect conclusions. In case study 2, we consider the design and flexible operation of IESs that hybridize conventional generators with energy storage. Through a sensitivity analysis, we find that as the size of the storage system increases, the total number of start-ups for coal- and natural gas-based IESs reduced by 25% and 33.6%, and the total thermal generator ramping (i.e., mileage) reduced by 86.5% and 62.5%, respectively. This shows the primary benefit of storage may not be reduced operational costs (which do not change significantly) but fewer start-ups and less ramping, which may greatly simplify the design, operation, and control of carbon capture systems. The new modeling and optimization capabilities from this work enable the coupling of rigorous, dynamic process models with grid-level production cost models to quantitatively identify the nuanced interdependencies across these vast timescales that must be addressed to realize clean, safe, and secure energy production. Moreover, the proposed general multiscale simulation framework is applicable to all IES technologies and can be easily extended to consider other energy carriers (e.g., hydrogen, ammonia) and energy infrastructures (e.g., natural gas pipelines).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A techno-economic evaluation of solar-powered green hydrogen production for sustainable energy consumption in Belgium

Here this study focuses on the production and consumption of solar-powered green hydrogen in Belgium by comparing the costs of domestic production with those of imports from Morocco and Namibia. The levelized cost of hydrogen (LCOH) is determined via a techno-economic assessment considering various parameters including, power connectivity, electrolyzer types, location factors, and risk premium. The results show that the lowest LCOH can be achieved by on-grid Proton exchange membrane electrolyzers (PEMEL). LCOH of production in Belgium, Morocco, and Namibia with a PEMEL on-grid system are 5.64, 6.32 and 5.13 euro/kg H 2 , respectively. Thus, importing hydrogen from Namibia to Belgium is more competitive than domestic production. The sensitivity analysis suggests that a target LCOH of 3 euro/kg H 2 is achievable by importing from Namibia through various cost combinations. One of these combinations involves reducing the cost of PV panels to 222.3 euro/kW (70% reduction) and electrolyzers to 363.3 euro/kW (25% reduction).

08 HYDROGEN↗

Shared mooring system designs and cost estimates for wave energy arrays

For floating renewable energy devices to become more cost-efficient and commercially scalable, their mooring system designs must be low-cost and suited for large-scale installations. Large arrays of floating devices, such as wave energy converters (WECs), will likely be designed with an individual mooring system for each device in the array. However, new mooring technology advancements provide options to use shared mooring lines to connect adjacent devices to one another, reducing the total number of anchors in the array, thereby reducing material use and cost. Here, this paper explores the design, modeling, and cost analysis of shared mooring systems for various sizes of arrays consisting of heaving oscillating water column (OWC) WECs. Shared mooring systems for WEC arrays sized in 2 x N and N x N grid layouts are designed to meet the relevant design standards, checking their performance with a nonlinear time-domain dynamic simulation, and the costs of each are calculated and compared. Several assumptions are taken in the design process to produce efficient results, providing a preliminary optimization for guidance on design decisions rather than a full, detailed design analysis. Mooring system costs per WEC were found to decrease as the number of WECs in the array increase, up to certain array sizes. The 2 x 3 array had the lowest mooring system cost per WEC out of all arrays considered, with a 60% cost reduction relative to using individual mooring systems. The 3 x 3 and 4 x 4 arrays achieved a 50% cost per WEC reduction. In addition to these significant cost reductions, the shared mooring system designs can provide advantages through smaller mooring system footprints, lower installation times, and less seabed disturbance.

16 TIDAL AND WAVE POWER↗

The Dual Nature of Entrainment-Mixing Signatures Revealed through Large-Eddy Simulations of a Convection-Cloud Chamber

Abstract Entrainment of subsaturated air into a cloud can influence its optical and microphysical properties in various ways, depending on the droplet evaporation and turbulent mixing time scales. Previous experiments in the Pi convection-cloud chamber have revealed that, given a fixed entrained air property, the mixing of entrained subsaturated air results in complete evaporation of some cloud droplets, with the rest remaining unchanged. This is a signature of inhomogeneous mixing. While comparing the results of entrainment with varying air properties, the mixing signature appears as if the subsaturated air is well mixed with the cloud to evenly reduce the droplets’ size. In other words, taken together, the experiments appear to have the signature of homogeneous mixing. To explore these results in a greater depth, we conduct large-eddy simulations combined with a bin microphysics scheme. Our results reproduce the similar signatures of inhomogeneous and homogeneous mixing, implying that LES can resolve the inhomogeneous mixing when the grid spacing is smaller than the entrained air parcel. Additionally, we observe that increasing the aerosol injection rate enhances the signature of inhomogeneous mixing, while coarser grid spacing diminishes it. Finally, the change in wall fluxes in response to various entrained air properties confirms that the homogeneous signature seen in the analysis of an ensemble of simulations is the result of various equilibrium states. This further strengthens the suggestion that the homogeneous mixing signature found in aircraft observations near the cloud top may result from combining entrainment events of different intensities, possibly caused by various-sized eddies. Significance Statement Large-eddy simulation and size-resolved microphysics can resolve time scales for turbulent mixing and evaporation and, therefore, are well suited for reproducing, extending, and interpreting the entrainment experiment in the Pi convection-cloud chamber. Our simulation results confirm (i) the inhomogeneous mixing signature for an individual entrainment event and (ii) the appearance of homogeneous mixing in an ensemble of entrainment episodes. Furthermore, we demonstrate that the inhomogeneous mixing signature is more pronounced in a polluted cloud, but coarser grid spacing in simulations may compromise the accuracy of this signature. Last, the homogeneous mixing signature results from various equilibrium states established for different entrainment intensities and adjusted wall fluxes, which are challenging to measure experimentally but can be easily analyzed in the simulations.

54 ENVIRONMENTAL SCIENCES↗

How many offshore wind turbines does New England need?

The proliferation of countries and regions with 100% clean or renewable energy targets necessitates an analysis to determine the number of generating units and storage needed to meet real-time electricity demand on the electric grid. The coastal areas of New England have the capacity to produce a large percentage of the region's energy needs with offshore wind turbines. Here we model offshore wind turbine power production data using MERRA-2 reanalysis and lidar wind speed data sets. We compare this power production to the New England hourly grid demand over the course of one year. 2,000 10 MW offshore wind turbines could satisfy New England's grid demand for about 37% of the year. When combined with 55 GWh of storage, 2,000 turbines could satisfy grid demand for about 72% of the year.

17 WIND ENERGY↗

Evaluating alternative steam generation pathways in the food industry

Steam generation in the food sector requires substantial energy and cost expenditures, requiring nearly half of its energy intake. Here, we used life cycle assessment and life cycle cost assessment to investigate the cost and energy impacts of steam generating alternatives: NG, biomass and hydrogen boilers and grid-supplied and self-generated electric steam generation systems (electric boilers, renewable thermal energy storage and industrial heat pumps). The analysis starts with a set of average U.S. conditions, where biomass boilers are the most cost-competitive alternative to NG. In a series of scenarios beyond average conditions, the analysis shows energy procurement costs dominate the total life cycle cost for all technologies and, unfortunately, are highly variable geographically and temporally, significantly affecting the viability of the alternatives. Results show that site-energy consumption ranges from 0.3 MMBtu/klb for industrial heat pumps to 1.6 MMBtu/klb for biomass boilers, with heat pumps achieving up to 78% lower energy use compared to natural gas systems. For the steam costs, the results show a range between $\$$8 and $\$$50/klb for NG, with biomass following closely ($\$$11 – $\$$44/klb) and grey hydrogen and IHP next ($\$$13 – $\$$33/klb and $\$$6 - $\$$78/klb), with cost reductions if IHP's cooling is utilized. Factors like operating hours, the need for cooling, and the ability to negotiate utility rates complicate the decision, making site-specific analyses critical. Therefore, we present a decision-making matrix to help manufacturers identify which steam generating technology is the best business decision for their situation. Overall, these results highlight the importance of steam generation for the facility's organizational goals, as well as the criticality of conducting individual site analyses.

Biomass boilers↗

Evaluation of CMIP6 models in simulating the statistics of extreme precipitation over Eastern Africa

We report the Eastern Africa region experiences frequent extreme precipitation events that can cause destruction of property and environment, and loss of lives. Thus, there is a need to understand how these events may change in the future and how well the global climate models that are used to make projections can simulate precipitation extremes in this region before they can be used in downscaling or flood and drought impact assessment studies. In this work, we evaluated the ability of sixteen Coupled Model Intercomparison Project Phase 6 (CMIP6) models to simulate present-day precipitation extremes over the Eastern Africa region during the two rainy seasons (March–May and September–November). We used nine extreme precipitation indices (including seven (one) indices of wet (dry) extremes) defined by the Expert Team on Climate Change Detection and Indices. The CMIP6 models were evaluated against two gridded observation datasets: Global Precipitation Climatology Project One-Degree Daily Dataset and Tropical Rainfall Measuring Mission Multi-satellite Precipitation Analysis 3B42. Three model performance metrics (percentage bias, normalized root-mean-square error, and pattern correlation coefficient) were employed to further assess the strengths and weakness of the models. Our results show that the multi-model ensemble mean generally provides a better representation of observed precipitation and related extremes compared to individual models when considering all metrics and seasons. Several consistent biases are evident across CMIP6 models, which tend to overestimate the total-wet day precipitation and consecutive wet days, and underestimate very wet days and maximum 5-day precipitation in both seasons. Furthermore, no single model consistently performs best, model performance varies with the season and index under consideration and is generally independent of horizontal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Urban heat islands can influence the wind energy resource during heatwaves

Urban wind energy is critical for sustainable electricity generation in cities. However, little research has explored how the urban heat island (UHI) effect influences wind energy, particularly in heatwaves when energy demand surges. In this study, we examine wind energy distribution in the Boston–Providence metropolitan area during heatwaves, using Weather Research and Forecasting (WRF) model integrated with Building Energy Parameterization/Building Energy Model (BEP/BEM). Two scenarios, a realistic case and a hypothetical case without urban warmth, were compared to isolate UHI impacts. Results reveal that UHI induces a "wind energy loss zone" in this urban area, reducing wind power density (WPD) by 20–30 W/m 2 at 50–100 m, while suburban/rural areas exhibit a "wind energy gain zone," with WPD increases up to 40 W/m 2 at 150–200 m. These losses diminish with distance from urban centers and become negligible beyond main urban and suburban sprawl. Heatwave expands the urban "loss zone", while amplifying wind energy gains in suburban/rural areas, driven by stronger thermal gradients and weakened background winds that intensify air convergence in urban and urban-rural circulations, thereby exacerbating urban wind energy losses by 15–20 %. An analysis of 235 wind farms using turbine power curves reveals that built areas dependent on stand-alone or off-grid turbines face significant energy deficits during a heatwave. Wind energy drops by up to 25 %, while cooling-related building energy demand rises 30–40 % during a heatwave. These findings underscore the need for strategic urban wind energy planning to ensure reliable power during extreme heat.

Energy - Wind↗

Interactions of Wind Energy Project Siting, Wind Resource Potential, and the Evolution of the U.S. Power System

The interactions of wind energy project siting, resource potential, and power system evolution are critical to understand given interest in high renewable energy systems, particularly as wind costs have fallen and grid operators implement solutions to manage variable generation. This study applies an integrative approach that combines spatially-explicit resource potential analysis with high spatial resolution U.S. electricity system modeling. Multiple wind supply curves, representing variations in siting regimes that account for interactions with built infrastructure, regulatory, physical, and social land use factors, are evaluated to determine how siting could influence prospective wind development. Different siting regimes lead to variations in future wind capacity, with the greatest impacts observed under scenarios with high demand for clean energy. With the tightest emissions limit modeled, 2050 onshore wind capacity varied by +7% (49 GW) in the least-restrictive siting regime to a decrease of 37% (270 GW) under the most-constrained case. More-stringent siting restrictions lead to higher electricity prices and emissions that should be weighed with local impacts. Under restrictive siting regimes, wind deployment is also sensitive to transmission availability and wind plant design. Overall, the findings highlight the importance of local land use considerations in regional and national power system planning.

17 WIND ENERGY↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

gcm_eval (Global Climate Model Evaluation) [SWR-24-37]

The interplay between energy, climate, and weather is becoming more complex as our changing climate continues to affect the weather we experience which in turn drives changes in the ever increasing share of renewable energy generation and energy demand. Energy system analyses commonly rely on meteorological inputs to estimate renewable energy generation and energy demand; however, these inputs rarely represent the estimated impacts of future climate change. Climate models and publicly available climate change datasets can be used for this purpose, but the selection of inputs from the myriad of available models and datasets is a nuanced and often subjective process. There is no single perfect climate model or dataset for all applications. In this repository, we include software and the corresponding assessments of various global climate models (GCMs) from the Coupled Model Intercomparison Project (CMIP6), evaluating their skills with respect to the historical climate and comparing of their future projections of climate change. We focus on variables that directly affect the energy system including the representation of extreme values that can drive grid resilience events. The objective of this repository is not to recommend the best climate model and dataset for a given analysis, but instead to provide a reference to facilitate the selection of climate models and datasets in subsequent work.

Buster, Grant↗

Platform Of Optimal Experiment Management

The platform of optimal experiment management, POEM, powered with automated machine learning to accelerate the discovery of optimal solutions, and automatically guide the design of experiments to be evaluated. POEM currently supports 1) random model explorations for experiment design, 2) sparse grid model explorations with Gaussian Polynomial Chaos surrogate model to accelerate experiment design ,3) time-dependent model sensitivity and uncertainty analysis to identify the importance features for experiment design, 4) model calibrations via Bayesian inference to integrate experiments to improve model performance, and 5) Bayesian optimization for optimal experimental design. In addition, POEM aims to simplify the process of experimental design for users, enabling them to analyze the data with minimal human intervention, and improving the technological output from research activities.

Wang, Congjian [Idaho National Laboratory (INL), I↗

Hacking Kilometer-Scale Models: A Participative Model for Climate Information

In May 2025, nearly 700 participants from all around the world coalesced at 10 regional nodes and a few satellite nodes to take part in a global hackathon of kilometer-scale (horizontal grid spacing < 10 km) regional and global Earth system models. Exciting science is emerging from these efforts, ranging across novel model analysis, new ways of integrating with satellite data, and emulation with machine learning. New technologies were trialed that enable the community to work in new and complementary ways to democratize access to global information at a local scale from a set of the world’s highest-resolution climate models. The hackathon demonstrated how exascale data can be organized to be accessible to anyone. Fundamentally, the community could apply these techniques and technologies to move toward more participative models for coproduction and delivery of diverse sources of climate information for climate scientists and citizens alike.

Climate models↗

Scaling Up Energy Efficiency Investment in Emerging Markets - Private Sector Perspectives

Since 2000, electricity demand has flattened and decoupled from Gross Domestic Product (GDP) growth in the Organization for Economic Cooperation and Development (OECD) countries. This trend is anticipated to continue for the next several decades and is largely attributed to the implementation of energy efficiency measures. However, non-OECD countries (emerging markets) have experienced, and are projected to continue experiencing, increasing electricity demands. If the world is to meet the requirements of the Paris Agreement, annual investments in clean energy and energy efficiency need to increase by a factor of six by 2050, compared to 2015. Information presented in this paper is based on qualitative and quantitative data collection and analysis methods to provide an empirical understanding of barriers to private sector clean energy investment including microgrid development, energy efficiency, smart grid development, and utility-scale wind and solar in emerging markets. Through literature review, a survey, and a series of webinar dialogues, USAID and the U.S. Department of Energy National Renewable Energy Laboratory (NREL) solicited input from private sector actors, including developers, project financiers, manufacturers and technical assistance service providers, on the challenges they face to market entry in emerging markets, and their suggestions for improving market competitiveness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

OEDI—Solar Grid Integration Data and Analytics Library

As a part of the Open Energy Data Initiative, this effort aims to develop and demonstrate novel distribution state estimation, control optimization, and transient analysis as well as provide access to data, data integration, and mapping information. More specifically, the focus of the effort will be on physics-based distribution system state estimation, hybrid (physics-based and machine learning) distribution optimal power flow, and event detection/analysis for solar integration and analytics. This work will enable reproducible, robust, replicable, and generalizable R&D in simulation and emulation of solar system integration. These test models and datasets will provide an integrated library for developing and testing power system operation technologies. To make the library user-friendly, this project will provide data curation tools such as data translators, mapping scripts and APIs, database schemas and metadata, interfaces and user dashboard, source code for the reference algorithms, description of the use-cases/scenarios, and comprehensive information on all the assumptions.

14 SOLAR ENERGY↗

WBS 2.2.1.402 - Wave-SPARC: Systematic Process & Analysis for Reaching Commercialization

Wave-SPARC is empowering the marine energy community with the tools necessary to achieve a significant improvement in techno-economic performance of wave generated grid power. A detailed systems engineering approach simultaneously balances around 100 cost and performance drivers (functional requirements and capabilities) of wave energy converters (WECs). Publicly accessible technology innovation and assessment methods and tools (new to the wave energy sector) have been delivered. They guide technology development trajectories to successful outcomes in less time, at less overall cost, and with less encountered risk. Through the use of these methods and tools along with proven structured inventive techniques the project continues to deliver high potential novel wave energy technology concepts for validation and subsequent development by industry. The intended outcomes are: (1) Invention, assessment, identification, verification and validation of novel and high techno-economic-potential WEC technology concepts to deliver high-confidence "seeds" for subsequent industrial development to full commercial application and economic viability (2) Development and delivery of WEC technology innovation and assessment methodologies and tools and provision of these as services and for free use by industry and the entire sector (3) International collaboration for global best practice alignment of assessment and innovation methods.

innovation↗