Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Using IR spectroscopy to determine biodiesel conversion

This project’s aim was to develop a way to use Infrared (IR) Spectroscopy to determine the extent of the conversion of oil to biodiesel produced during a typical transesterification process. The most reliable method of biodiesel analysis is gas chromatography with flame ionization detector (GC-FID) analysis. This analysis is not ideal for the educational or field applications since it is time intensive and requires expensive, specialized equipment. The use of the FT-IR is faster and more affordable. A calibration curve was created by comparing data on the purity of biodiesel samples obtained from the GC-FID analysis to the ratio of the absorbances at 1197 cm -1 to 1166 cm -1 from the FT-IR spectrum. For field application, a similar method was developed using a portable IR spectrometer, the InfraSpecTM VFA-IR spectrometer. As a result, the data collected gave a good linear fit for % purity of the samples and can be used as a method for monitoring the conversion of different types of oils to biodiesel and determining the purity of biodiesel produced from oil.

09 BIOMASS FUELS↗

Advanced Analytical Methodologies Enable Feedstock Screening and Correlation to Pyrolysis Yields and Catalytic Upgrading

Pyrolysis of lignocellulosic biomass can serve as a powerful pathway for the generation of renewable fuels and industrial products. However, procurement of some biomass may be costly, especially when there is competition for alternative uses. Forestry and agricultural byproducts may serve as valuable pyrolysis feedstocks due to their high availability and low cost. Although waste products may fill demand for affordable pyrolysis feedstocks, they are often high in ash and extractives which contribute to unfavorable changes in pyrolysis vapor composition, as well as end products. The work presented here investigates the correlations between various pine anatomical fractions to understand their effect on pyrolysis oil composition for forest residues. Analytical pyrolysis coupled to direct analysis by molecular beam mass spectrometry (MBMS) provides real-time monitoring of pyrolysis vapor composition, even for compounds that are not amenable to gas chromatography. Statistical analysis of MBMS data from the fast pyrolysis (FP) of clean pine, cambium, twigs and branches, needles, bark, and a forest residue samples revealed that bark and needles made the greatest differences in the vapor composition of forest residues during pyrolysis and were enriched in resin acids, furfural derivatives, and ions that have been previously observed from catalysis corresponding to ash content. These results were also compared to catalytic fast pyrolysis (CFP) using a platinum on titania catalyst, and correlations between FP and CFP products were observed for the anatomical fractions. The forest residues and corresponding anatomical fractions from a stand of 23-year-old pine will be converted by fast pyrolysis in a bench-scale 2-inch fluidized-bed reactor, and statistical correlations between the bench-scale products and analytical-scale pyrolysis vapors will be shown. This work highlights the power of advanced analytical methodologies in determining the contributions of vapor components to catalytic pyrolysis outcomes for mixed feedstocks and demonstrates the use of analytical methodologies to better screen feedstocks prior to pyrolysis.

analytical↗

Electrochemical Ammonia Compression

An electrochemical (EC) compressor is a solid-state compression device. For decades, researchers have been studying EC compressors for applications for a variety of energy systems. As the world transitions away from fossil fuel energy sources, EC compression emerges as a promising technique for energy storage, specifically energy stored in the form of pressurized ammonia. Ammonia is also a commonly used refrigerant. The present studies examine the viability of EC compression for ammonia storage and refrigeration. EC ammonia compression increases the concentration of an ammonia-hydrogen mixture via the input of electrical energy and a series of chemical reactions. A polymer electrolyte membrane separates the low-concentration side from the high-concentration side of the device. On the low-pressure (anode) side hydrogen atoms oxidize and react with ammonia molecules, forming positively charge ammonium ions. The ions traverse the membrane electrolytically. The ammonium ions are reduced and revert back to hydrogen and ammonia upon reaching the high-pressure (cathode). An external circuit provides the current needed to sustain the reactions. In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm2 of active area. We demonstrated the operation of larger cells with 100 cm2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state. We analyzed the effects of pressure and current on the EC compressor performance. We measured the flow rates of gas leaving the compressors and analyzed the composition using gas chromatography. We tested methods of separating ammonia from the effluent vapor, which contained hydrogen and water vapor. We found that back diffusion adversely affected the performance, especially when we maintained high pressure lifts.

25 ENERGY STORAGE↗

Health monitoring device

Example aspects of a volatile organic compound detection device, a wearable health monitoring device, and a method of monitoring a user's health are disclosed. The volatile organic compound detection device can comprise a collector comprising a collector material configured to collect volatile organic compounds given off from a user's skin; a separator comprising a gas chromatography column configured to separate mixtures of the volatile organic compounds into their constituent chemicals; and an identifier comprising a detector and a processor, the detector configured to transduce the constituent chemicals into a signal, the processor configured to process the signal to identify specific volatile organic compounds indicative of a health condition.

42 ENGINEERING↗

Seizure detection device

A method of detecting a seizure includes collecting volatile organic compounds with a collector material of a collector; separating a mixture of the volatile organic compounds into its constituent chemicals with a gas chromatography column; ionizing the constituent chemicals to create ionized chemicals and detecting the ionized chemicals; and analyzing the ionized chemicals to identify seizure-indicative volatile organic compounds.

Arnold, Gary Stephen↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Methods for improved preconcentrators

The present invention relates generally to chemical analysis (e.g. by gas chromatography), and in particular to a compact chemical preconcentrator formed on a substrate with a heatable sorptive membrane that can be used to accumulate and concentrate one or more chemical species of interest over time and then rapidly release the concentrated chemical species upon demand for chemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MS Based Metabonomics

Metabonomics is the latest and least mature of the systems biology triad, which also includes genomics and proteomics, and has its origins in the early orthomolecular medicine work pioneered by Linus Pauling and Arthur Robinson. It was defined by Nicholson and colleagues in 1999 as the quantitative measurement of perturbations in the metabolite complement of an integrated biological system in response to internal or external stimuli, and is often used today to describe many non-global types of metabolite analyses. Applications of metabonomics are extensive and include toxicology, nutrition, pharmaceutical research and development, physiological monitoring and disease diagnosis. For example, blood samples from millions of neonates are tested routinely by mass spectrometry (MS) as a diagnostic tool for inborn errors of metabolism. The metabonome encompasses a wide range of structurally diverse metabolites; therefore, no single analytical platform will be sufficient. Specialized sample preparation and detection techniques are required, and advances in NMR and MS technologies have led to enhanced metabonome coverage, which in turn demands improved data analysis approaches. The role of MS in metabonomics is still evolving as instrumentation and software becomes more sophisticated and as researchers realize the strengths and limitations of current technology. MS offers a wide dynamic range, high sensitivity, and reproducible, quantitative analysis. These attributes are essential for addressing the challenges of metabonomics, as the range of metabolite concentrations easily exceeds nine orders of magnitude in biofluids, and the diversity of molecular species ranges from simple amino and organic acids to lipids and complex carbohydrates. Additional challenges arise in generating a comprehensive metabolite profile, downstream data processing and analysis, and structural characterization of important metabolites. A typical workflow of MS-based metabonomics is shown in Figure 1. Gas chromatography-(GC)-MS was the most commonly used MS-based method for small molecule analysis in the 1970s and 1980s. It is still used today for the detection of many metabolic disorders and plays a strong role in plant metabonomics. Liquid chromatography (LC)-MS approaches have grown in popularity for metabolite studies, due to simpler sample preparation, reduced analysis times through the introduction of ultra-high performance liquid chromatography (UPLC)-MS and the ability to observe a wider range of metabolites. This chapter will discuss the role of MS in metabonomics, the techniques involved in this exciting area, and the current and future applications of the field. The various bioinformatics tools and multivariate analysis techniques used to maximize information recovery and to aid in the interpretation of the very large data sets typically obtained in metabonomics studies will also be discussed. While there are many different MS-based approaches utilized in metabonomics studies, emphasis will be placed on more established methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of higher diamondoids by pulsed laser ablation plasmas in supercritical CO{sub 2}

Pulsed laser ablation (wavelength 532 nm; fluence 18 J/cm{sup 2}; pulse width 7 ns; repetition rate 10 Hz) of highly oriented pyrolytic graphite was conducted in adamantane-dissolved supercritical CO{sub 2} with and without cyclohexane as a cosolvent. Micro-Raman spectroscopy of the products revealed the presence of hydrocarbons possessing sp{sup 3}-hybridized carbons similar to diamond structures. The synthesis of diamantane and other possible diamondoids consisting of up to 12 cages was confirmed by gas chromatography-mass spectrometry. Furthermore, gas chromatography-mass spectrometry measurements of samples before and after pyrolysis treatment indicate the synthesis of the most compact decamantane, namely, superadamantane. It is thought that oxidant species originating from CO{sub 2} during pulsed laser ablation might lead to the selective dissociation of C-H bonds, enabling the synthesis of low H/C ratio molecules. Therefore, laser ablation in supercritical CO{sub 2} is proposed as a practical method for synthesizing diamondoids.

36 MATERIALS SCIENCE↗

Aliphatic Amines from Waste Polyolefins by Tandem Pyrolysis, Hydroformylation, and Reductive Amination

Pyrolysis of waste plastics can produce a product mixture with a high concentration of olefins (>50 wt%). The olefins, as building blocks in the petroleum industry, are potential precursors for valuable commodity chemicals with higher values (>$2000 per ton). In this work, we produce aldehydes by hydroformylation of the olefins present in pyrolysis oil from colored post-consumer recycled high-density polyethylene (PCR-HDPE). The obtained aldehydes in the oil are then converted into aliphatic amines via reductive amination with a Ru/C catalyst. The aminated oil was characterized by multiple analytical chemistry techniques including elemental analysis, nuclear magnetic resonance spectroscopy, high-resolution liquid chromatography-mass spectrometry, and gas chromatography-mass spectrometry with a Polyarc flame ionization detector. The concentration of metals in the PCR-HDPE and oil changes during the tandem processes, showing limited effects of these elements (e.g., Al, Ca, Fe, Mg, Ti, Zn) on hydroformylation and reductive amination. Additionally, we demonstrated that reductive amination of aldehydes with varied carbon numbers and branching properties can be achieved in the presence of a complex mixture, including paraffins and aromatics. The results indicate that waste plastics have the potential to serve as a renewable source for mono and di aliphatic amines, thereby diminishing reliance on fossil feedstocks as the current primary amine source.

aliphatic amines↗

Chemical Characterization and Thermal Stressing Studies of Perfluorohexane Fluids for Space-Based Applications

Perfluorohexane (PFH), C6F14, is a perfluorocarbon fluid. Several PFH fluids with different isomer concentrations were evaluated for use in an upcoming NASA space experiment. Samples tested included two commercially obtained high-purity n-perfluorohexane (n-PFH) fluids and a technical grade mixture of C6F14 branched and linear isomers (FC-72(TradeMark)). These fluids were evaluated for exact chemical composition, impurity purity and high temperature degradation behavior (pyrolysis). Our investigation involved simulated thermal stressing studies of PFH fluids under conditions likely to occur in the event of an atmospheric breach within the International Space Station (ISS) and subsequent exposure of the vapors to the high temperature and catalyst present in its Trace Contaminant Control Subsystem (TCCS). Exposure to temperatures in the temperature range of 200-450 C in an inert or oxidizing atmosphere, with and without the presence of catalyst was investigated. The most aggressive conditions studied were exposure of PFH vapors to 450 C in air and in the presence of TCCS (palladium) catalyst. Gas chromatography-mass spectrometry (GC-MS) and gas chromatography (GC) analyses were conducted on the perfluorohexane samples before and after pyrolysis. The FC-72 and n-PFH samples showed no significant degradation following pyrolysis even under the most aggressive study conditions. Some trace level impurities associated with the PFH samples such as linear perfluorocarbon monohydrides or monoiodides were destroyed by pyrolysis at the upper limit. Other trace level impurities such as olefinic or cycloolefinic perfluorocarbons were converted into oxidation products by pyrolysis. The purity of PFH following pyrolysis actually increased slightly as a consequence since these trace contaminants were effectively scrubbed from the samples. However, since the initial concentrations of the thermally-impacted impurities were so low, the net effect was trivial. A potential byproduct of exposure of perfluorohexane fluids to high temperatures is the production of perfluoroisobutene (PFiB), which is extremely toxic. An ultra-high sensitivity PFiB-specific analysis based on GC-MS with negative ion chemical ionization (NICI) detection was used to evaluate the samples following thermal stressing. The perfluorohexanes examined here under conditions reflective of the ISS TCCS environment showed no signs of PFiB production with an analytical detection limit of 10 part per billion (ppb v/v).

Arnold, William A.↗

Application of evolved gas analysis to cold-cap reactions of melter feeds for nuclear waste vitrification

The melter feed (a mixture of nuclear waste and glass forming and modifying additives) experiences multiple gas-evolving reactions in an electrical glass-melting furnace during the vitrification of nuclear wastes. Foams from the residual gases can significantly alter the melting rate through mass and heat transfers. Here, we employed the thermogravimetry-gas chromatography-mass spectrometry (TGA-GC-MS) combination to perform quantitative evolved gas analysis (EGA) and developed a simple calibration model which correlates the overall mass loss rate with the evolution rates for individual gases. The model parameters are obtained from the least squares analysis, assuming that the gas-evolving reactions are independent. Finally, the EGA adds the ‘chemical identity’ to the reactions indicated by the ‘phenomenological’ kinetic model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-phase characterization of pitch-carbon coated nano-silicon anodes for lithium-ion batteries

Silicon (Si) is a leading next-generation Li-ion battery anode candidate that meets rigorous performance demands for portable power including enhanced power and energy density with robust cycling performance. However, a series of complex and interrelated reactions lead to reduced calendar life in Si-containing systems and therefore challenge practical adoption. In the present work, we probe the mechanisms underlying observed performance improvements by adding a pitch-carbon coating onto nano-Si material. We pair solid-phase (X-ray photoemission spectroscopy, Fourier-transform infrared), semi-volatile phase (solid-phase microextraction-gas chromatography-mass spectrometry), and gas-phase (gas chromatography-flame-ionization detector) characterization signals to comprehensively evaluate the impact of pitch-carbon coating on the evolution of the Si solid-electrolyte interphase (SEI) and the associated impacts on electrode/electrolyte reactivity. The pitch-carbon is found to serve as a physicochemical barrier, reducing the electro-active surface area for Si/electrolyte reactivity and preventing Si oxidation. Further, the pitch-carbon coating promotes the evolution of a more-favorable SEI by subsuming substantial functionality typically associated with the fluoroethylene carbonate (FEC) electrolyte additive - such as alkoxide scavenging and suppression of transesterification pathways - and by shifting the competitive electrolyte degradation pathways' favorability. The multi-phase characterization approach enables holistic end-products evaluation from complex (electro)chemical interfacial reactions, which informs a robust interpretation of the carbon coating's role in electrochemical performance improvements. The present mechanistic evaluation aids the rational design for improved nano-Si materials.

25 ENERGY STORAGE↗

Metabolomics analysis reveals elevation of 3-indoxyl sulfate in plasma and brain during chemically-induced acute kidney injury in mice: Investigation of nicotinic acid receptor agonists

An investigative renal toxicity study using metabolomics was conducted with a potent nicotinic acid receptor (NAR) agonist, SCH 900424. Liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) techniques were used to identify small molecule biomarkers of acute kidney injury (AKI) that could aid in a better mechanistic understanding of SCH 900424-induced AKI in mice. The metabolomics study revealed 3-indoxyl sulfate (3IS) as a more sensitive marker of SCH 900424-induced renal toxicity than creatinine or urea. An LC-MS assay for quantitative determination of 3IS in mouse matrices was also developed. Following treatment with SCH 900424, 3IS levels were markedly increased in murine plasma and brain, thereby potentially contributing to renal- and central nervous system (CNS)-related rapid onset of toxicities. Furthermore, significant decrease in urinary excretion of 3IS in those animals due to compromised renal function may be associated with the elevation of 3IS in plasma and brain. These data suggest that 3IS has a potential to be a marker of renal and CNS toxicities during chemically-induced AKI in mice. In addition, based on the metabolomic analysis other statistically significant plasma markers including p-cresol-sulfate and tryptophan catabolites (kynurenate, kynurenine, 3-indole-lactate) might be of toxicological importance but have not been studied in detail. This comprehensive approach that includes untargeted metabolomic and targeted bioanalytical sample analyses could be used to investigate toxicity of other compounds that pose preclinical or clinical development challenges in a pharmaceutical discovery and development. - Research Highlights: > Nicotinic acid receptor agonist, SCH 900424, caused acute kidney injury in mice. > MS-based metabolomics was conducted to identify potential small molecule markers of renal toxicity. > 3-indoxyl-sulfate was found to be as a more sensitive marker of renal toxicity than creatinine or urea. > 3-IS levels were increased not only in murine plasma but also in the brain. > 3-IS potentially contributes to renal-and CNS-related rapid onset of toxicities.

60 APPLIED LIFE SCIENCES↗

Amino acids of the Murchison meteorite. I - Six carbon acyclic primary alpha-amino alkanoic acids

Six of the seven chain isomers of six-carbon acyclic primary alpha-amino alkanoic acids (leucine isomers) have been either identified or confirmed in hot-water extracts of the Murchison meteorite using combined gas chromatography-mass spectrometry (GC-MS) and ion exchange chromatography. 2-Amino-2-ethylbutyric acid, 2-amino-2,3-dimethylbutyric acid, pseudoleucine, and 2-methylnorvaline were positively identified by GC-MS. These amino acids have not been previously reported to occur in natural materials and may be uniquely meteoritic in origin. The presence of leucine and isoleucine (including the diastereoisomer, alloisoleucine) was confirmed. Peaks corresponding to norleucine were seen by ion-exchange and gas chromatography but characteristic mass spectra were not obtained. The alpha-branched chain isomers in this series are quantitatively the most significant. These results are compared with literature data on amino acid synthesis by electrical discharge and Fischer-Tropsch-type catalysis. Neither model system produces an amino acid suite that is completely comparable to that found in the Murchison meteorite.

Cronin, J. R.↗