Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Trace Metal Inventories and Lead Isotopic Composition Chronicle a Forest Fire’s Remobilization of Industrial Contaminants Deposited in the Angeles National Forest

The amounts of labile trace metals: [Co] (3 to 11 mg g -1 ), [Cu] (15 to 69 mg g -1 ), [Ni] (6 to 15 mg g -1 ), [Pb] (7 to 42 mg g -1 ), and [Zn] (65 to 500 mg g -1 ) in ash collected from the 2012 Williams Fire in Los Angeles, California attest to the role of fires in remobilizing industrial metals deposited in forests. These remobilized trace metals may be dispersed by winds, increasing human exposures, and they may be deposited in water bodies, increasing exposures in aquatic ecosystems. Correlations between the concentrations of these trace metals, normalized to Fe, in ash from the fire suggest that Co, Cu, and Ni in most of those samples were predominantly from natural sources, whereas Pb and Zn were enriched in some ash samples. The predominantly anthropogenic source of excess Pb in the ash was further demonstrated by its isotopic ratios ( 208 Pb/ 207 Pb: 206 Pb/ 207 Pb) that fell between those of natural Pb and leaded gasoline sold in California during the previous century. These analyses substantiate current human and environmental health concerns with the pyrogenic remobilization of toxic metals, which are compounded by projections of increases in the intensity and frequency of wildfires associated with climate change.

59 BASIC BIOLOGICAL SCIENCES↗

Model Data Archive Associated with Manuscript "Fire-altered Carbon Pools Create Disturbance Memory in Stream Dissolved Organic Carbon"

This data package supports the publication “Fire-altered Carbon Pools Create Disturbance Memory in Stream Dissolved Organic Carbon” by Li et al. (2026). The package contains processed model inputs, configuration files, restart files, simulation outputs, scripts, and visualization products used to evaluate post-fire dissolved organic carbon (DOC) dynamics in the Naches River Watershed, Washington, USA, following the 2021 Schneider Springs Fire. The modeling workflow couples ELM-BGC, the biogeochemistry-enabled Energy Exascale Earth System Model Land Model; ATS, the Advanced Terrestrial Simulator for integrated surface-subsurface hydrology; and PFLOTRAN, a reactive transport model for multicomponent aqueous geochemistry. Together, these models simulate how wildfire-induced changes in vegetation, litter, coarse woody debris, and soil organic matter influence DOC production, transport, and reaction from burned hillslopes to stream networks. The archive includes preprocessed meteorological, geospatial, hydrologic, and biogeochemical forcing data; ELM-BGC-derived DOC source terms; ATS mesh files; PFLOTRAN reactive-transport inputs; model configuration files; spin-up and transient restart files; watershed-scale diagnostic outputs; stream concentration time series; and figures or visualization files used to inspect and reproduce key results. File types include Hierarchical Data Format 5 (HDF5) files for gridded forcing and model-coupling data, model input and configuration files for ELM-BGC, ATS, and PFLOTRAN, restart and simulation-output files generated by the modeling workflow, tabular or time-series diagnostic outputs, scripts for post-processing and figure generation, and image or visualization products associated with the manuscript. Use of the package depends on the intended task. Re-running the simulations requires the relevant modeling software, including ELM-BGC, ATS, and PFLOTRAN as ATS's geochemical engine. Inspecting outputs and reproducing figures requires Python with scientific plotting libraries such as Matplotlib, and three-dimensional model outputs may be viewed with ParaView. Geographic information system files or maps may be inspected with ArcGIS Pro or comparable GIS software. The data package is intended to enable traceability, reuse, and partial reproduction of the coupled land-to-watershed hydro-biogeochemical modeling workflow used to test how wildfire disturbance affects terrestrial carbon pools and downstream DOC dynamics.

ATS↗

AmeriFlux FLUXNET-1F US-Rwf RCEW Upper Sheep Prescibed Fire

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Rwf RCEW Upper Sheep Prescibed Fire. This is the FLUXNET version of the carbon flux data for the site US-Rwf RCEW Upper Sheep Prescibed Fire produced by applying the standard ONEFlux (1F) software. Site Description - The site is located on the USDA-ARS's Reynolds Creek Experimental Watershed. It is a recovering mountain big sagebrush site after a 2007 prescrobed fire

Flerchinger, Gerald↗

AmeriFlux FLUXNET-1F US-Fcr Cascaden Ridge Fire Scar

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Fcr Cascaden Ridge Fire Scar. This is the FLUXNET version of the carbon flux data for the site US-Fcr Cascaden Ridge Fire Scar produced by applying the standard ONEFlux (1F) software. Site Description - Burned black spruce forest by a moderate fire at 2010

Ueyama, Masahito↗

Discrimination of Small Earthquakes and Buried Single-Fired Chemical Explosions at Local Distances (<150 km) in the Western United States from Comparison of Local Magnitude ( M L ) and Coda Duration Magnitude ( M C )

Seismologists distinguish underground nuclear explosions from more commonly occurring earthquakes using moment tensor inversion, high-frequency P/S amplitude ratios, m b :M s comparisons, and P–pP differential travel times. These methods are generally successful for large seismic events (M >3-4) well recorded at regional-to-teleseismic distances (>150 km); however, it is unclear whether they can be modified to work for small events (M <3) well recorded only at local distances (<150 km). Here, we evaluate a recently proposed, local-distance seismic source discriminant—the difference between local magnitude (M L ) and coda duration magnitude (M C )—using seismograms of earthquakes and buried, single-fired chemical explosions recorded in three regions of the western United States. The quantity M L –M C was previously found to be sensitive to source depth, effectively discriminating mine blasts, induced earthquakes, and very shallow tectonic earthquakes from deeper crustal earthquakes. In this study, we report the first evaluation of M L –M C as a depth discriminant using data from buried, single-fired explosions that, unlike the seismic sources studied earlier, are good analogs for underground nuclear explosions. We find that even when using generic, uncalibrated methods of assigning magnitudes, M L –M C separates single-fired explosions and earthquakes. The area under the receiver operating characteristic curve is 0.92 for 19 explosions and 14 earthquakes in Washington, 0.90 for 22 explosions and 90 earthquakes in Wyoming, and 0.99 for three explosions and 149 earthquakes in Nevada. Finally, M L :M C comparisons have the potential to enhance discrimination based on high-frequency P/S amplitudes ratios—which perform less well at local than regional distances—because the two metrics have complementary sensitivities.

58 GEOSCIENCES↗

Floodplain Assessment for the Proposed Outdoor Fire Range Upgrades at TA-72 in Lower Sandia Canyon, Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) is preparing to implement actions in Sandia Canyon at Technical Area (TA) 72. Los Alamos National Security (LANS) biologists conducted a floodplain determination and this project is partially located within a 100-year floodplain. The proposed project is to upgrade the existing outdoor shooting range facilities at TA-72. These upgrades will result in increased safety and efficiencies in the training for Protective Force personnel. In order to remain current on training requirements, the firing ranges at TA-72 will be upgraded which will result in increased safety and efficiencies in the training for Protective Force personnel (Figure 1). These upgrades will allow for an increase in class size and more people to be qualified at the ranges. Some of these upgrades will be built within the 100-year floodplain. The upgrades include: concrete pads for turning target systems and shooting positions, new lighting to illuminate the firing range for night fire, a new speaker system for range operations, canopies at two locations, an impact berm at the far end of the 300-yard mark, and a block wall for road protection.

Basic Biological Sciences(59)↗

Development and Validation of a Gas-Fired Residential Heat Pump Water Heater (Final Report)

For gas-fired residential water heating, the U.S. and Canada is predominantly supplied by minimum efficiency storage water heaters with Energy Factors (EF) in the range of 0.59 to 0.62. Higher efficiency and higher cost ($\$$700 - $\$$2,000) options serve about 15% of the market, but still have EFs below 1.0, ranging from 0.65 to 0.95. To develop a new class of water heating products that exceeds the traditional limit of thermal efficiency, the project team designed and demonstrated a packaged water heater driven by a gas-fired ammonia-water absorption heat pump. This gas-fired heat pump water heater can achieve EFs of 1.3 or higher, at a consumer cost of $\$$2,000 or less. Led by Stone Mountain Technologies Inc. (SMTI), with support from A.O. Smith, the Gas Technology Institute (GTI), and Georgia Tech, the cross-functional team completed research and development tasks including cycle modeling, breadboard evaluation of two cycles and two heat exchanger classes, heat pump/storage tank integration, compact solution pump development, combustion system specification, and evaluation of packaged prototype GHPWHs. The heat pump system extracts low grade heat from the ambient air and produces high grade heat suitable for heating water in a storage tank for domestic use. Product features that include conventional installation practices, standard footprint and reasonable economic payback, position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions from domestic hot water production.

03 NATURAL GAS↗

Thermal Integration of CO 2 Compression Processes with Coal-Fired Power Plants Equipped with Carbon Capture

Coal-fired power plants, equipped either with oxycombustion or post-combustion CO 2 capture, will require a CO 2 compression system to increase the pressure of the CO 2 to the level needed for sequestration. Most analyses show that CO 2 compression will have a significant effect on parasitic load, will be a major capital cost, and will contribute significantly to reduced unit efficiency. This project used first principle engineering analyses and computer simulations to determine the effects of utilizing compressor waste heat to improve power plant efficiency and increase net power output of coal-fired power plants with carbon capture. This was done for units with post combustion solvent-based CO 2 capture systems and for oxyfired power plants, firing bituminous, PRB and lignite coals. The thermal integration opportunities analyzed for oxycombustion capture are use of compressor waste heat to reheat recirculated flue gas, preheat boiler feedwater and predry high-moisture coals prior to pulverizing the coal. Among the thermal integration opportunities analyzed for post combustion capture systems are use of compressor waste heat and heat recovered from the stripper condenser to regenerate post-combustion CO 2 capture solvent, preheat boiler feedwater and predry high-moisture coals. The overall conclusion from the oxyfuel simulations is that thermal integration of compressor heat has the potential to improve net unit heat rate by up to 8.4 percent, but the actual magnitude of the improvement will depend on the type of heat sink used and to a lesser extent, compressor design and coal rank. The simulations of a unit with a MEA post combustion capture system showed that thermal integration of either compressor heat or stripper condenser heat to preheat boiler feedwater would result in heat rate improvements from 1.20 percent to 4.19 percent. The MEA capture simulations further showed that partial drying of low rank coals, done in combination with feedwater heating, would result in heat rate reductions of 7.43 percent for PRB coal and 10.45 percent for lignite.

01 COAL, LIGNITE, AND PEAT↗

Seismic Fire Evaluation

This report describes an approach for modeling the number of ignitions (fires) following an earthquake. It is an update from a previous calculation (March 2012), “Modeling the Number of Ignitions Following an Earthquake: Developing Prediction Limits for Overdispersed Count Data,” performed by Elizabeth Kelly and Raymond Tell. This update incorporates comments from two reviews conducted by Douglas Honneger (March 2011) and Shane Reese (February 2013). Also, a comparison is made here with the Nuclear Regulatory Commission methodology developed by John Lambright for prediction of the likelihood of a seismically-induced fire for the resolution of Generic Issue 57, “Evaluation of Generic Issue 57: Effects of Fire Protection System Actuation on Safety-Related Equipment,” NUREG-5580.

42 ENGINEERING↗

Material Analysis for a Fire Assessment.

This report consolidates technical information on several materials and material classes for a fire assessment. The materials include three polymeric materials, wood, and hydraulic oil. The polymers are polystyrene, polyurethane, and melamine- formaldehyde foams. Samples of two of the specific materials were tested for their behavior in a fire - like environment. Test data and the methods used to test the materials are presented. Much of the remaining data are taken from a literature survey. This report serves as a reference source of properties necessary to predict the behavior of these materials in a fire.

Brown, Alexander↗

Neutron Generator Production Facility (NGPF), Building 870: Structural Fire Protection Analysis and Basis of Design Report

This report was prepared to provide an explanation of the prescriptive-based code approach for the Neutron Generator Production Facility’s (NGPF) structural fire protection and construction classification determinations based upon the original code-of-record (1991-UBC) and current International Building Code (2012-IBC) requirements. The code approach presented in this report included a determination of the required construction type in accordance with the 2012-IBC. Through the evaluation of the record design drawings and subsequent site surveys, a determination was made of the existing types of materials used to construct the columns, beams, floor assemblies, roof assembly, and exterior and interior walls and partitions. A summary is provided for the fire resistance requirements of the different elements of the building. In addition, a determination was made in regards to the fire resistance hourly ratings of the columns, beams, floor assemblies, roof assembly, exterior walls, interiors walls and partitions, door openings, joints and penetrations. Through design evaluation, site survey, code verification, and review of record documents, the actual construction classification (Type II-B) was confirmed to be compliant with the 2012-IBC.

42 ENGINEERING↗

Logistics, Costs, and GHG Impacts of Utility-Scale Co-Firing with 20% Biomass

This study analyzes the possibility that biopower in the U.S. is a cost-competitive option to significantly reduce greenhouse gas emissions. In 2009, net greenhouse gas (GHG) emitted in the United States was equivalent to 5,618 million metric tons CO 2 , up 5.6% from 1990 (EPA 2011). Coal-fired power generation accounted for 1,748 million metric tons of this total. Intuitively, life-cycle CO 2 emissions in the power sector could be reduced by substituting renewable biomass for coal. If just 20% of the coal combusted in 2009 had been replaced with biomass, CO 2 emissions would have been reduced by 350 million metric tons, or about 6% of net annual GHG emission. This would have required approximately 225 million tons of dry biomass. Such an ambitious fuel substitution would require development of a biomass feedstock production and supply system tantamount to coal. This material would need to meet stringent specifications to ensure reliable conveyance to boiler burners, efficient combustion, and no adverse impact on heat transfer surfaces and flue gas cleanup operations. Therefore, this report addresses the potential cost/benefit tradeoffs of co-firing 20% specification-qualified biomass (on an energy content basis) in large U.S. coal-fired power plants. The dependence and sensitivity of feedstock cost on source of material, location, supply distance, and demand pressure was established. Subsequently, the dependence of levelized cost of electricity (LCOE) on feedstock costs, power plant feed system retrofit, and impact on boiler performance was determined. Overall life-cycle assessment (LCA) of greenhouse gas emissions saving were next evaluated and compared to wind and solar energy to benchmark the leading alternatives for meeting renewable portfolio standards (or RPS).

09 BIOMASS FUELS↗

Improving representation of drought stress and fire emissions in climate carbon models: measurements and modeling with a focus on the western USA

The objective of the proposed research was to collect data and develop models to improve our understanding of the role of drought and fire impacts on the terrestrial carbon cycle in the western US, including impacts associated with urban systems as they impacted regional carbon cycles. Using data we collected and a synthesis of other measurements, we developed new ways (a) to evaluate the representation of drought stress and fire emissions in the Community Land Model, (b) to model net ecosystem exchange combining ground level atmospheric observations with boundary layer theory, (c) to model upstream impacts of fire and fossil fuel emissions on atmospheric carbon dioxide observations, and (d) to model carbon dioxide observations within urban systems and at the urban-wildland interfaces of forest ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Pipe Overpack Container Fire Testing: Phase I & II

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a new series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016, and described herein, were done in two phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. This report will describe the various tests conducted in phase I and II, present preliminary results from these tests, and discuss implications for the POCs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wildland Fire Management Plan

The Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) is written to comply with Department of Energy (DOE) Integrated Safety Management Policy; Federal Wildland Fire Management Policy and Program Review; and Wildland and Prescribed Fire Management Policy and Implementation Procedures Reference Guide. This current plan incorporates changes resulting from new policies on the national level as well as significant changes to available resources and other emerging issues, and replaces BNL's Wildland FMP dated 2014.

54 ENVIRONMENTAL SCIENCES↗

Ensuring Reliable Natural Gas-Fired Generation with Fuel Contracts and Storage - DOE/NETL-2017/1816

This report finds that natural gas-fired power plants purchase fuel both on the spot market and through firm supply contracts; there do not appear to be clear drivers propelling power plants toward one or the other type. Most natural gas-fired power generators are located near major natural gas transmission pipelines, and most natural gas contracts are currently procured on the spot market. Although there is some regional variation in the type of contract used, a strong regional pattern does not emerge. Whether gas prices are higher with spot or firm contracts varies by both region and year. Natural gas prices that push the generators higher in the supply curve would make them less likely to dispatch. Most of the natural gas generators discussed in this report would be unlikely to enter firm contracts if the agreed price would decrease their dispatch frequency. The price points at which these generators would be unlikely to enter a firm contract depends upon the region that the generator is in, and how dependent that region is on natural gas. The Electric Reliability Council of Texas (ERCOT) is more dependent on natural gas than either Eastern Interconnection or Western Interconnection. This report shows that above-ground storage is prohibitively expensive with respect to providing storage for an extended operational fuel reserve comparable to the amount of on-site fuel storage used for coal-fired plants. Further, both pressurized and atmospheric tanks require a significant amount of land for storage, even to support one day’s operation at full output. Underground storage offers the only viable option for 30-day operational storage of natural gas, and that is limited by the location of suitable geologic formations and depleted fields.

01 COAL, LIGNITE, AND PEAT↗

Pipe Overpack Container Fire Testing: Phase I II & III.

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016 were done in three phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. The goal of the third phase was to see if surrogate aerosol gets released from the PC when the drum lid is off. This report will describe the various tests conducted in phase I, II, and III, present preliminary results from these tests, and discuss implications for the POCs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Techno-Economic Analysis of Integration of Low-Temperature Geothermal Resources for Coal-Fired Power Plants

Presented here are the results of a techno-economic (TEA) study of the potential for coupling low-grade geothermal resources to boost the electrical output from coal-fired power plants. This study includes identification of candidate 500 MW subcritical coal-fired power plants in the continental United States, followed by down-selection and characterization of the North Valmy generating station, a Nevada coal-fired plant. Based on site and plant characteristics, ASPEN Plus models were designed to evaluate options to integrate geothermal resources directly into existing processes at North Valmy. Energy outputs and capital costing are presented for numerous hybrid strategies, including integration with Organic Rankine Cycles (ORCs), which currently represent the primary technology for baseload geothermal power generation.

20 FOSSIL-FUELED POWER PLANTS↗