Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLASH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A Field Campaign to Study Lightning that Ignites the Bush

The impact of recent wildland fires in the United States and Australia have received much attention in the past several years. As a result, NASA has developed a new Earth Science program to better understand, predict, and manage this phenomenon, as well as a future suborbital mission to studying pyro-cumulonimbus clouds and their effects on the Earth system. In Australia, government and philanthropic stakeholders are supporting a series of field campaigns over the next few years to inform science requirements and advance technology for a future satellite mission to monitor Bushfires. Lightning flashes are a major source of wildland fires, but uncertainties remain about the physical characteristics of lightning and their parent thunderstorms responsible for igniting wildfires. It was long believed that most lightning-ignited wildfires are largely caused by positive flashes to the ground (CGs) and multi-stroke CGs, but a recent study looking at 26-years of NLDN data indicate otherwise. Perhaps this finding is due to statistical chance—there are more negative CGs that occur globally—or perhaps there is some unknown electrical property of the thundercloud from which the igniting flashes emanate. Regardless, new observing strategies are needed. Additionally, long continuing current CGs, which are more likely to ignite a fire, can elude detection by operational ground-based lightning location systems, making it difficult to efficiently identify potential wildland fires and manage them before they have adverse impacts. To address these science and operational gaps, NASA’s Lightning Mapping Array along with electric and magnetic field change meters will be deployed for the Australian Bushfire campaign to document the electrical structure and properties of thunderstorms and lightning that occur in a wildland fire susceptible region. Another aspect of the campaign will be the use of NASA’s airborne lightning observatory, which includes a spectrometer and high-speed imager, to document the radiometric attributes of these flashes coincident with the ground-based RF observations. These observations will be used to better understand the properties of lightning that ignite wildland fires as well as inform design of a lightning detection system for the future Bushfire Monitoring satellite mission.

lightning↗

Use of the SPoRT Stoplight Product to Support NWS Decision Support Services

The National Weather Service Forecast Offices (NWSFOs) use many weather tools and observational datasets to provide support for critical decision-making by core partners such as public safety officials, emergency managers, and first responders. These core partners who need weather decision support services (DSS) for outdoor events require up-to-the-minute weather information to ensure the safety and protection of attendees and workers. Storms and lightning, potentially deadly, pose a significant threat during outdoor events and are among the weather phenomena frequently cited as a DSS requirement. According to the National Lightning Safety Council, from 2014 up to August 2024, lightning resulted in 222 fatalities in the U.S. For outdoor events with hundreds to thousands of attendees, having the right tools to detect and monitor lightning activity is of utmost importance to protect lives. Common guidelines for lightning safety include moving inside a substantial structure at the first sight of threatening skies or the first sound of thunder, and waiting 30 minutes after the last lightning flash or thunder before returning outside. Using this guidance as a framework, scientists at the NASA Short-term Prediction Research and Transition (SPoRT) center have developed the Geostationary Lightning Mapper (GLM) Stoplight tool. This experimental tool uses the GLM Flash Extent Density imagery to display the location and recency of lightning flashes. To simplify interpretation, these lightning pixels are color-coded in 10-minute bins, ranging from red (lightning detected 0 to 10 minutes ago) to yellow (10 to 20 minutes ago) to green (20 to 30 minutes ago). The Stoplight tool also allows users to place markers at the location of outdoor events with range rings around the location to help in assessing the location and relative age of lightning flashes near and upstream of the event. The goal is to help NWS forecasters provide core partners with the necessary information to make the best decisions possible. While the Stoplight tool is experimental, forecasters at NWSFO Raleigh, NC, have periodically used the Stoplight guidance to evaluate its utility within NWS DSS. This presentation will discuss how the Stoplight tool was successfully used for DSS for four outdoor events in central NC in 2023 and 2024. Future improvements to this tool, including the addition of AI applications and the merging of ground-based lightning data with GLM data, will be reviewed.

Gail Hartfield↗

Novel Bremsstrahlung Converter Designs for Ultra High Dose Rate Radiotherapy Systems

Ultra-high dose rates (UHDR) have been shown to improve the therapeutic index in the treatment of cancer using external beam radiotherapy in many preclinical settings by inducing the so-called “FLASH” effect [1]; however, the underlying biological and physical mechanism(s) are still unknown. Recent work has been to expand the energy range of photons used in UHDR studies from keV photons generated in synchrotron to photons less than 8 MeV produced by accelerated electrons undergoing the bremsstrahlung interaction [2]. This work is a part of the FLASH-Experimental X-ray small Animal Conformal Therapy (FLASH-EXACT) project is aimed at producing a preclinical system that induces the FLASH effect with photons >10 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automated Laboratory Kilogram-Scale Graphene Production from Coal

The flash Joule heating (FJH) method converts many carbon feedstocks into graphene in milliseconds to seconds using an electrical pulse. This opens an opportunity for processing low or negative value resources, such as coal and plastic waste, into high value graphene. Here, in this work, a lab-scale automation FJH system that allows the synthesis of 1.1 kg of turbostratic flash graphene from coal-based metallurgical coke (MC) in 1.5 h is demonstrated. The process is based on the automated conversion of 5.7 g of MC per batch using an electrical pulse width modulation system to conduct the bottom-up upcycle of MC into flash graphene. This study then compare this method to two other scalable graphene synthesis techniques by both a life cycle assessment and a technoeconomic assessment.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of methods and improvement of predictions for specification properties of petroleum-based and alternative aviation fuels

To support our research and process modeling for liquid fuels, including blends, from petroleum and synthetic sources such as from biomass intermediates, we evaluated composition-based prediction methods and improved predictions for five key specification properties of petroleum-based and alternative aviation fuels, namely distillation temperatures (10 % distilled, t 10 , and final boiling point, t FBP ), density, flash point, net heat of combustion, and freezing point. The types of fuels included were petroleum-based jet fuels, jet-fuel surrogate mixtures, synthetic blending components obtained from different sources, and blends of Jet A with many synthetic blending components. Expanded datasets to update associated parameters allowed significant improvements for one of the prediction methods used in earlier work, namely the Modified Weighted Average method published initially by Shi et al. By considering the importance of lighter compounds for flash points and heavier compounds for freezing points, the revised Modified Weighted Average method was further improved. For liquid density, the revised Modified Weighted Average method gave the best overall results. The revised Modified Weighted Average method, the American Society for Testing and Materials D7215 method, and the D7215 method modified by another group gave comparable results for flash point, while the revised Modified Weighted Average and D3338 methods gave the best results for net heat of combustion. Freezing point was well predicted using the revised Modified Weighted Average method and showed the most significant improvements over current predictions. Distillation temperature t 10 was not well predicted, while t FBP was predicted with a mean absolute error comparable to experimental reproducibility.

09 BIOMASS FUELS↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers'’ for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field's Metal eutectic alloy with a melting point of 62°C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions. It is recommended that glass vessels of various volumes ranging from 125 mL to 1 gallon with modified tops containing the specified Field's Metal eutectic alloy which are appropriately designed to avoid flashing spray material releases be added to the DSA container list. These vessels will be utilized in the Shielded Cells for the storage of radioactive liquid samples of sludge slurries. Use of these vessels will also be advantageous for other liquid samples containing accountable amounts of nuclear material throughout other SRNL laboratories. Similarly constructed paraffin vessel lids could also potentially be added to the approved list, though additional testing would be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Terrestrial Glint Seen from Deep Space: Oriented Ice Crystals Detected from the Lagrangian Point

The deep space climate observatory (DSCOVR) spacecraft resides at the first Lagrangian point about one million miles from Earth. A polychromatic imaging camera onboard delivers nearly hourly observations of the entire sun-lit face of the Earth. Many images contain unexpected bright flashes of light over both ocean and land. We construct a yearlong time series of flash latitudes, scattering angles and oxygen absorption to demonstrate conclusively that the flashes over land are specular reflections off tiny ice platelets floating in the air nearly horizontally. Such deep space detection of tropospheric ice can be used to constrain the likelihood of oriented crystals and their contribution to Earth albedo. These glint observations also support proposals for detecting starlight glints off faint companions in our search for habitable exoplanets.

deep space observations↗

Methods for Evaluating DC Arc Incident Energy in PV Systems: Preprint

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This paper focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of DC arc flash incident energy evaluation. Because of the fast proliferation of PV systems and the lack of formal equivalent calculation guidelines such as IEEE 1584 for AC systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This paper discusses the behavior of PV systems under arc conditions and presents the results of available methods to estimate the dc arc flash incident energy. This paper provides a comparative analysis of a proposed arc-flash incident energy calculation method against different laboratory tests including those performed by NREL. Detailed explanations are provided regarding the effect of PV module I-V and P-V curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anisotropic thermal diffusivity and conductivity in SiC/SiC tubes studied by infrared imaging and X-ray computed tomography

Traditional flash diffusivity evaluation of thermal diffusivity/conductivity of composite tubes require machining of specimens. For a thin-wall tube, this method can only be used to obtain through-thickness transport property. A novel method to evaluate anisotropic thermal diffusivity in a composite tube has been developed. Braided SiC/SiC composite tubes were subjected to a xenon flash heating pulse. A high-speed, high-sensitivity infrared camera was used to measure surface temperature changes as a function of time and nondestructively detect subsurface defects/damages, such as macroscopic pores. Standard reference material (Pyroceram 9606) and curved SiC/SiC composite tube specimens were used to validate thermal diffusivity obtained from infrared imaging. Unlike the traditional method, there is no need prepare special specimens, and thermal diffusivity values in three orientations are obtained after a single flash. A finite element analysis model based on x-ray computed tomography scans was developed to simulate the heat transfer. In conclusion, this technique is significant in assessing thermal conductivity and inspecting the health of ceramic tubes during and after service.

36 MATERIALS SCIENCE↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A thermally-limited bubble growth model for the relaxation time of superheated fuels

Here, we propose a novel approach to evaluate the relaxation time of vapor bubble growth in the context of the flash boiling of a superheated liquid. In alternative to the empirical correlation derived from superheated water experiments almost fifty years ago, the new model describes the thermally-dominated growth of vapor bubbles in terms that are dependent on the local Jakob number (the ratio of sensible heat to latent heat during phase change) and the number density of vapor bubbles. The model is tested by plugging the resulting relaxation time into the Homogenous Relaxation Model (HRM). Flash-boiling simulations carried out with HRM are compared with n-pentane (C 5 H 12 ) injection and boil-off experiments conducted with a real-size, axial-hole, transparent gasoline injector discharging into a constant-pressure vessel. The long-distance microscopy images from the experiments, processed to derive the projected liquid volume (PLV) of the spray, provide a unique set of time-resolved validation data for direct fuel injection simulations. At conditions ranging from flaring to mild and minimal flash boiling, we show that switching to the new relaxation time improves the agreement with the measured PLV profiles with respect to the standard empirical model. Particularly at flaring conditions, the predicted increase in gas cooling caused by rapid vapor production is shown to be more consistent with the observed boil-off.

42 ENGINEERING↗

On the Rate Constant for NH 2 +HO 2 and Third-Body Collision Efficiencies for NH 2 +H(+M) and NH 2 +NH 2 (+M)

In low-temperature flash photolysis of NH 3 /O 2 /N 2 mixtures, the NH 2 consumption rate and the product distribution is controlled by the reactions NH 2 + HO 2 → products (R1), NH 2 + H (+M) → NH 3 (+M) (R2), and NH 2 + NH 2 (+M) → N 2 H 4 (+M) (R3). In the present work, published flash photolysis experiments by, among others, Cheskis and co-workers, are re-interpreted using recent direct measurements of NH 2 + H (+N 2 ) and NH 2 + NH 2 (+N 2 ) from Altinay and Macdonald. To facilitate analysis of the FP data, relative third-body collision efficiencies compared to N 2 for R2 and R3 were calculated for O 2 and NH 3 as well as for other selected molecules. We report results were in good agreement with the limited experimental data. Based on reported NH 2 decay rates in flash photolysis of NH 3 /O 2 /N 2 , a rate constant for NH 2 + HO 2 → NH 3 + O 2 (R1a) of $k_{1\text{a}}$ = 1.5(±0.5) × 10 14 cm 3 mol –1 s –1 at 295 K was derived. This value is higher than earlier determinations based on the FP results but in good agreement with recent theoretical work. Kinetic modeling of reported N 2 O yields indicates that NH 2 + HO 2 → H 2 NO + O (R1c) is competing with R1a, but perturbation experiments with addition of CH4 indicate that it is not a dominating channel. Measured HNO profiles indicate that this component is formed directly by NH 2 + HO 2 → HNO + H 2 O (R1b), but theoretical work indicates that R1b is only a minor channel. Based on this analysis, we estimate $k_{1\text{c}}$ = 2.5 × 10 13 cm 3 mol –1 s –1 and $k_{1\text{b}}$ = 2.5 × 10 12 cm 3 mol –1 s –1 at 295 K, with significant uncertainty margins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗

On the study of hydrodynamic instabilities in the presence of background magnetic fields in high-energy-density plasmas

Blast-wave-driven hydrodynamic instabilities are studied in the presence of a background B-field through experiments and simulations in the high-energy-density (HED) physics regime. In experiments conducted at the Laboratoire pour l’utilisation des lasers intenses (LULI), a laser-driven shock-tube platform was used to generate a hydrodynamically unstable interface with a prescribed sinusoidal surface perturbation, and short-pulse x-ray radiography was used to characterize the instability growth with and without a 10-T B-field. The LULI experiments were modeled in FLASH using resistive and ideal magnetohydrodynamics (MHD), and comparing the experiments and simulations suggests that the Spitzer model implemented in FLASH is necessary and sufficient for modeling these planar systems. These results suggest insufficient amplification of the seed B-field, due to resistive diffusion, to alter the hydrodynamic behavior. Although the ideal-MHD simulations did not represent the experiments accurately, they suggest that similar HED systems with dynamic plasma-β (=2μ0ρv2/B2) values of less than ∼100 can reduce the growth of blast-wave-driven Rayleigh–Taylor instabilities. These findings validate the resistive-MHD FLASH modeling that is being used to design future experiments for studying B-field effects in HED plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Denial of Service Attack Detection via Differential Analysis of Generalized Entropy Progressions

Denial-of-Service (DoS) attacks are one the most common and consequential cyber attacks in computer networks. While existing research offers a plethora of detection methods, the issue of achieving scalability, a low false positive rate, and high detection accuracy remains open. In this work, we address this problem by developing a differential method based on generalized entropy progression. In this method, named as DoDGE, we continuously fit the line of best fit to the entropy progression of destination addresses and check if the derivative, that is, the slope of this line is less than the negative of the dynamically computed standard deviation of the derivatives. Furthermore, to distinguish from flash events, we leverage the symmetry that when a flash event occurs, the derivative of the entropy progression of source addresses is positive. With this design, we omit the usage of the thresholds and the results with five real-world network traffic datasets confirm that DoDGE outperforms threshold-based DoS attack detection by two orders of magnitude in terms of false positives on average. When compared to ten machine learning (ML) models, DoDGE achieves a balanced accuracy of 99%, while the average balanced accuracy for the ML models is 52%. Moreover, the results show that DoDGE successfully differentiates between a flash event and a DoS attack. Furthermore, since the main computation cost of DoDGE is the entropy computation, which is linear in the volume of the unit-time network flow, uses integer only operations, and works on a small fraction of the total flow, it is lightweight and scalable.

Cybersecurity, wireless communication↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

Towards Multilayered Coatings of 304L Stainless Steels Using Friction Surfacing

Abstract The objective of this work is to study friction surfacing process variability when depositing multilayered coatings. This is motivated by the need to maintain deposition quality when depositing multiple friction surfacing layers, whether for repair, remanufacturing, or new part creation using this solid-state metal additive manufacturing process. In this study, 10-mm-diameter 304L stainless steel rods were used to create up to five layers of 40-mm-long coatings on 304L substrates using a constant set of processing parameters. In-process measurement of forces (X, Y, Z), flash temperature, flash geometry, layer temperature, and post-process measurement of layer geometry, microhardness, and microstructure are used to characterize changes in the friction surfacing process as more layers are deposited. It was observed that with increasing layers: layer thickness and deposition efficiency decrease; offsetting of the deposition towards the retreating side, and temperature in the deposited layer increase; and flash temperature does not change. Metallurgical analyses of friction-surfaced cross-sections revealed fine grain refinement and transformation of base austenite to strain-induced martensite. It is concluded that the process parameters need to be adjusted even after the second or third layer is deposited, corrections to the tool path are required after a couple of layers, and the measured process forces, as well as deposited layer temperature, may be useful to monitor and control the process and its instabilities.

Engineering↗

effect of ambient pressure on the behavior of single-component fuels in a gasoline multi-hole injector

The injection characteristics of neat ethanol and pure isooctane are studied under different ambient pressure and temperature conditions. Injection underflash-boiling conditions can enhance liquid atomization and evaporation, providing the possibility of improvement in the fuel/air mixing. These superheated conditions often introduce phenomena that are not taken into account in the standard modeling of sprays for engine applications. The present work proposes a numerical investigation of the behavior of Engine Combustion Network's 8-hole spray-G injector, starting at the subcooled nominal condition and reducing the ambient pressure at constant low temperature to reach the flare flash-boiling condition. To initialize the properties of the injected fuel, the flow in the nozzle is simulated with a Eulerian approach, handling the two phases with a mixture model and the phase change, due to cavitation and flash boiling, with the Homogenous Relaxation Model. A map of the mixture's kinematic and thermal behavior is obtained at the interface between the injector and the chamber to initialize the Lagrangian simulations. A literature-based vaporization model is implemented to obtain the proper description of the characteristic features of a multi-hole spray under super-heated conditions, like plume-plume interaction. The numerical representation of the spray is validated in terms of penetration and radial spreading on DBI images, reproducing the light attenuation profiles caused by the presence of the liquid spray. Simulations show that coupled nozzle flow and spray calculations capture the spray morphology and shape better compared to calculations performed without considering the nozzle flow simulation details, especially under flare flash conditions.

Nocivelli, Lorenzo↗