Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Correlating the influence of porosity, tortuosity, and mass loading on the energy density of LiNi 0.6 Mn 0.2 Co 0.2 O 2 cathodes under extreme fast charging (XFC) conditions

Extreme fast charging capabilities along with high energy density of Li-ion batteries are the key factors to increase the adoption of electric vehicles while eliminating the problem of range anxiety. The U.S Department of Energy has a goal of <12 min charging time with energy density of > 200 Wh kg -1 . A combined improvement in the electrode architecture, electrolyte properties, and separator membrane is necessary to achieve this goal. Cells with thin electrodes are capable of extreme fast charging at the expense of low energy density and high cost. Electrode engineering can maximize energy density. In this work, the influence of porosity, mass loading and charging protocols on capacity and energy density and electrode kinetics are investigated under extreme fast charging conditions. Increasing the mass loading from 11.5 mg cm -2 to 25 mg cm -2 compromises the rate performance due to the mass transport limitation and underutilization of thick electrodes. Furthermore, reducing the electrode porosity from 50% to 35% improves the rate performance ascribed to shorter Li ion diffusion length. Symmetric cells are cycled to verify the performance of the half cells, suggesting that Li metal plating is the rate limiting step under high current density.

25 ENERGY STORAGE↗

Extreme fast charge aging: Correlation between electrode scale and heterogeneous degradation in Ni-rich layered cathodes

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. There are no systematic studies in the open literature regarding aging modes in Ni-rich Li y Ni 0.a Mn 0.b Co 0.c O 2 (NMCabc) cathodes caused by fast charging. Herein, we report the effects of cathode composition and electrode loading in pouch cells containing NMC532, 622 and 811 paired with graphite and cycled under XFC conditions. The relative anisotropic volume change in the unit cell increases with Ni content in low-loading cells, while it levels up for all three NMC cathodes in high-loading cells because of substantial Li plating. The amounts of lithium plating and heterogeneity on the anode, determined by crystallographic phase quantification, were found to be correlated with electrode loading and cathode heterogeneity. The concentrations of the transition metals deposited on the anodes depend on NMCabc composition in a complex way. More particle cracking and surface degradation was found in NMC811. Here, the findings in this work provide a new understanding of the failure mechanisms and their practical implications for compositional tuning of future high-Ni NMCabc cathode materials during fast charging.

25 ENERGY STORAGE↗

Operando FTIR investigation of salt dynamics in Li-ion batteries during fast charging

Li-ion batteries, when charged at fast-charging rates ($>$2C), suffer from reduced lifetimes and can undergo catastrophic failure. During high-rate charging, Li-ions are unable to rapidly transport through high-loading electrodes ($>$4 mAh cm −2 ). This results in unequal charge distributions, potentials, and utilization of the active material, which can lead to Li plating. Li-ion concentration polarization, in which Li-ions deplete in the anode and accumulate in the cathode during charging, precedes Li plating. An operando FTIR-ATR graphite/NMC cell developed in this research captured Li-ion concentration polarization in real-time. During fast charging, decreases in Li-ion concentration ($>$95%) were measured at the back of the anode. This is the first verification of complete Li-ion depletion within the anode at high C-rates. The measurements also showed graphite stage transition. A P2D model was developed for comparison to the operando measurements. The measurements agreed with the model in some cases, but disparities existed at high C-rates and loadings. In the experiment, the Li-ion concentration often failed to recover to 1.2 M until several hours after charging, whereas the model Li-ion concentration rapidly recovered. The contrast between the model and experiment results indicates that further investigation is required to improve understanding of Li-ion concentration dynamics during fast charging.

25 - ENERGY STORAGE↗

Fast Charge Induced Phase Evolution and Element Contribution of Nickel-Rich Layered Cathode for Lithium-Ion Batteries

In nickel-rich layered cathode materials, three transition metals (TM = Ni, Co and Mn) play critical roles in Li storage performance. However, rate-dependent phase evolution and elemental contribution of nickel-rich cathode materials are not well understood, but very important for further design and development of these cathodes in high-power applications. Here, the rate-dependent phase evolution and elemental contribution of LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC532) cathode are investigated thoroughly by using time-resolved synchrotron-based in situ X-ray diffraction and absorption techniques. The increase of Ni content in NMC532 has been found to be the main cause of the complex structural changes, resulting in distortion of TM-O 6 octahedron and strong static vibration between TM and O coordination. It is revealed that the fast charge (10C and 30C) of NMC532 leads to intermediate Li-poor phases, shrinking of H2 phase region, and prolonged O1 phase. During high-rate charging, Co is oxidized easily in low voltage region, while Ni mainly dominates charge compensation in high voltage region. It is found that delithiation-induced local structure distortion transfers from Ni to Co sites in fast kinetic process. In conclusion, these findings provide in-depth understanding for the fast charge behavior of Ni-rich layered cathode materials and help to guide further development of advanced high-power lithium-ion batteries.

25 ENERGY STORAGE↗

Bright and ultra-fast scintillation from a semiconductor?

Semiconductor scintillators are worth studying because they include both the highest luminosities and shortest decay times of all known scintillators. Moreover, many semiconductors have the heaviest stable elements (Tl, Hg, Pb, and Bi) as a major constituent and a high ion pair yield that is proportional to the energy deposited. Here, we review the scintillation properties of semiconductors activated by native defects, isoelectronic impurities, donors and acceptors with special emphasis on those that have exceptionally high luminosities (e.g. ZnO:Zn; ZnS:Ag, Cl; CdS:Ag, Cl) and those that have ultra-fast decay times (e.g. ZnO:Ga; CdS:In). We discuss underlying mechanisms that are consistent with these properties and the possibilities for achieving (1) 200,000 photons/MeV and 1% fwhm energy resolution for 662 keV gamma rays, (2) ultra-fast (ns) decay times and coincident resolving times of 30 ps fwhm for time-of-flight positron emission tomography, and (3) both a high luminosity and an ultra-fast decay time from the same scintillator at cryogenic temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Graphite Lithiation under Fast Charging Conditions: Atomistic Modeling Insights

The charging of lithium ion batteries in a fast and safe manner is critical for promoting the mass adoption of electric vehicles. Li intercalation in graphite electrodes is known to be one of the bottlenecks during the fast charging process. The mechanism of Li diffusion in highly polarized graphite anode at high current rates remains, however, not well understood. In this work, Density Functional Theory (DFT) calculations are used to gain insights into the Li diffusion process in graphite when it is far from equilibrium under fast charging conditions. The effect of uncompensated charges on Li mobility is determined in the highly polarized regions of the anode close to the interfaces. The extra charge was found to increase the interlayer spacing in the diffusion layer and adjacent channels, increasing the diffusivity and promoting the formation of Li clusters. A concerted diffusion mechanism at the edge of high-concentration Li domains is proposed to enhance the diffusion of Li.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic Analysis of Microstructural Attributes to Lithium Plating in Fast Charging

Metallic lithium deposition on graphite anodes is a critical degradation mode in lithium-ion batteries, which limits safety and fast charge capability. A conclusive strategy to mitigate lithium deposition under fast charging yet remains elusive. Herein, we examine the role of electrode microstructure in mitigating lithium plating behavior under various operating conditions, including fast charging. The multilength scale characteristics of the electrode microstructure lead to a complex interaction of transport and kinetic limitations that significantly governs the cell performance and the occurrence of Li plating. We demonstrate, based on a comprehensive mesoscale analysis, that the performance and degradation can be significantly modulated via systematic design improvements at the hierarchy of length scales. It is found that the improvement in kinetic and transport characteristics achievable at disparate scales can dramatically affect Li plating propensity.

25 ENERGY STORAGE↗

A Unified Analytical Method to Quantify Three Types of Fast Frequency Response from Inverter-Based Resources

With more inverter-based resources (IBRs), our power systems have lower frequency nadirs following N-1 contingencies, and undesired under-frequency load shedding (UFLS) can occur. To address this challenge, IBRs can be programmed to provide at least three types of fast frequency response (FFR), e.g., step response, proportional response (P/f droop response), and derivative response (synthetic inertia). However, these heterogeneous FFR challenge the study of power system frequency dynamics. Thus, this paper develops an analytical frequency nadir prediction method that allows for the consideration of all three potential forms of FFR provided by IBRs. The proposed method provides fast and accurate frequency nadir estimation after N-1 generation tripping contingencies. Our method is grounded on the closed-form solution for the frequency nadir, which is solved from the second-order system frequency response model considering the governor dynamics and three types of FFR. The simulation results in the IEEE 39-bus system with different types of FFR demonstrate that the proposed method provides an accurate and fast prediction of the frequency nadir under various disturbances.

fast frequency response↗

Thermal and fast neutron detection in chemical vapor deposition single-crystal diamond detectors

Recently, a compact solid-state neutron detector capable of simultaneously detecting thermal and fast neutrons was proposed [M. Marinelli et al., Appl. Phys. Lett. 89, 143509 (2006)]. Its design is based on a p-type/intrinsic/metal layered structure obtained by Microwave Plasma Chemical Vapor Deposition (CVD) of homoepitaxial diamond followed by thermal evaporation of an Al contact and a {sup 6}LiF converting layer. Fast neutrons are directly detected in the CVD diamond bulk, since they have enough energy to produce the {sup 12}C(n,{alpha}){sup 9}Be reaction in diamond. Thermal neutrons are instead converted into charged particles in the {sup 6}LiF layer through the {sup 6}Li(n,{alpha})T nuclear reaction. These charged particles are then detected in the diamond layer. The thickness of the {sup 6}LiF converting layer and the CVD diamond sensing layer affect the counting efficiency and energy resolution of the detector both for low- (thermal) and high-energy neutrons. An analysis is carried out on the dynamics of the {sup 6}Li(n,{alpha})T and the {sup 12}C(n,{alpha}){sup 9}Be reactions products, and the distribution of the energy released inside the sensitive layer is calculated. The detector counting efficiency and energy resolution were accordingly derived as a function of the thickness of the {sup 6}LiF and CVD diamond layers, both for thermal and fast neutrons, thus allowing us to choose the optimum detector design for any particular application. Comparison with experimental results is also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast Neutron Dose Evaluation Using CR39 by Coincidence Counting Process

The solid state nuclear tracks detection (SSNTD) technique is widely used in the area of radiation dosimetry. Different materials can be used applying this technique as glass and the most used in the dosimetry field that are the polycarbonates, CR39 and Makrofol-DE. Both are very rich in hydrogenous, that enables the SSNTD to detect fast neutrons through recoils of protons in the own detector material, without need of converters. The low reproducibility of its backgroundhas often been the major drawback in the assessment of low fluences of fast neutrons with SSNTDs. This problem can be effectively solved by counting coincidence of tracks in two detectors foils irradiated in close contact. After processing and counting only tracks produced by the same recoil nuclei on the surfaces of both detectors are considered as a track. This procedure enables the reduction of the background counts in the response of the detectors. In this work a preliminary study on the application of the coincidence technique for neutron dosimetry is presented. The CR39 material was investigated aiming to achieve the personal dose equivalent for fast neutrons. Using this method of analysis a significant reduction on the lower detectable dose was observed resulting even one order of magnitude smaller value. Reading, however, needs to be automated due to the large areas necessary to achieve a satisfactory number of tracks for statistical significance of results.

61 RADIATION PROTECTION AND DOSIMETRY↗

A time-gating scintillation detector for the measurement of laser-induced fast neutrons

A time-gating scintillation detector, in which a fast high voltage switch is used for gating a channel photomultiplier, was developed for a measurement of laser-induced fast neutrons. The x rays generated from the intense femtosecond laser and the solid target interactions were suppressed selectively and a time-of-flight signal of a laser-generated fast neutron was measured effectively. The detector was used successfully to measure the neutron yield of a femtosecond, deuterated, polystyrene plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamond detector for high rate monitors of fast neutrons beams

A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t{sub 0}. Fast acquisition is needed since the peak count rate is very high ({approx}800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range E{sub dep}= 1.5-7 MeV ascribed to neutron elastic scattering on {sup 12}C; iii) large pulse amplitude neutron events with E{sub n} < 7 MeV ascribed to {sup 12}C(n,{alpha}){sup 9}Be and 12C(n,n')3{alpha}.

43 PARTICLE ACCELERATORS↗

Performance study of polycrystalline CVD diamond detectors for fast neutron monitoring

Diamond detectors using polycrystalline CVD diamond substrates of thickness 300μm and 100μm were fabricated for fast neutron monitoring application.. The characterization of detectors was carried out using various tests such as leakage current, capacitance and alpha particle response. The performance of detectors was evaluated for fast neutrons at different neutron yields. The results presented in this work demonstrate that the diamond detectors will be suitable for monitoring fast neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oh, My Darling Clementine: A Detailed History and Data Repository of the Los Alamos Plutonium Fast Reactor

The Los Alamos Plutonium Fast Reactor, Clementine, provided the first fast neutron spectrum using a metallic plutonium fuel system and liquid mercury coolant. Clementine is often mentioned in the history of fast, metal-fueled, or metal-cooled designs, with little public information regarding the specifications or timeline. This paper contains a synopsis of each report regarding the development, operation, experimental results, failures, and subsequent disassembly of Clementine to explore this unique reactor within the context of modern advanced reactor development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New Integrated Analysis Suite for Fast-Ion Study in KSTAR

Here, an integrated workflow for fast-ion analysis was developed by adapting the One Modeling Framework for Integrated Task (OMFIT) workflow manager to support a standard and unified analysis platform for KSTAR users. The newly established analysis suite offers a graphical user interface–based workflow to enable users to readily access and handle experimental data archived in various data formats and servers. Further, users can analyze the data by importing modules designed for conducting certain tasks, such as profile fitting, equilibrium reconstruction, and postprocessing of tokamak data. The procedures for preparing the inputs for fast-ion simulations are streamlined by a common workflow manager, which enables the parallel processing of various tasks to efficiently analyze large fast-ion datasets. The OMFIT platform comprises a flexible Python-based application that enables users to freely manipulate the Python scripts for applications that are unavailable in the standard workflow. The framework also offers mapping tools to translate the output data into the Integrated Modeling and Analysis Suite format to maintain application compatibility for future ITER burning plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BENCHMARKING FAST-TO-ALFVEN MODE CONVERSION IN A COLD MAGNETOHYDRODYNAMIC PLASMA

Alfven waves may be generated via mode conversion from fast magnetoacoustic waves near their reflection level in the solar atmosphere, with implications both for coronal oscillations and for active region helioseismology. In active regions this reflection typically occurs high enough that the Alfven speed a greatly exceeds the sound speed c, well above the a = c level where the fast and slow modes interact. In order to focus on the fundamental characteristics of fast/Alfven conversion, stripped of unnecessary detail, it is therefore useful to freeze out the slow mode by adopting the gravitationally stratified cold magnetohydrodynamic model c {yields} 0. This provides a benchmark for fast-to-Alfven mode conversion in more complex atmospheres. Assuming a uniform inclined magnetic field and an exponential Alfven speed profile with density scale height h, the Alfven conversion coefficient depends on three variables only: the dimensionless transverse-to-the-stratification wavenumber {kappa} = kh, the magnetic field inclination from the stratification direction {theta}, and the polarization angle {phi} of the wavevector relative to the plane containing the stratification and magnetic field directions. We present an extensive exploration of mode conversion in this parameter space and conclude that near-total conversion to outward-propagating Alfven waves typically occurs for small {theta} and large {phi} (80{sup 0}-90{sup 0}), though it is absent entirely when {theta} is exactly zero (vertical field). For wavenumbers of helioseismic interest, the conversion region is broad enough to encompass the whole chromosphere.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MARS-F/K modeling of plasma response and fast ion losses due to RMP in KSTAR

Abstract The toroidal single-fluid magnetohydrodynamic (MHD) code MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) and the MHD-kinetic hybrid code MARS-K (Liu et al 2008 Phys. Plasmas 15 112503) are utilized to study the plasma response to the n = 1 ( n is the toroidal mode number) resonant magnetic perturbation (RMP), applied to suppress the type-I edge localized mode (ELM) in a KSTAR discharge. Both the resistive-rotating and ideal-static plasma models identify strong screening of the resonant radial field harmonics of the applied RMP due to the plasma response, and predict a strong edge-peeling response of the plasma which is consistent with the optimal ELM control coil current configuration adopted in experiment. The RMP-induced radial displacement of the plasma, computed by the resistive-rotating plasma model, agrees reasonably well with that reconstructed from the measured data in the plasma core. Taking into account the drift kinetic response of fast ions, MARS-K hybrid modeling also finds quantitative agreement of the plasma core fluid pressure perturbation with experiment. Based on the MARS-F computed plasma response, a guiding-center orbit-tracing simulation finds about 0.3% of fast ion losses due the n = 1 RMP in the KSTAR ELM control experiment considered. Most losses are associated with counter-current fast ions located near the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗